Regulated
Converter
Description
RAC
RAC05-K/277
5 Watt
Single
Output
YEA R
3
arrant
w
The RAC05-K/277 series are multipurpose 5 watt AC/DC power supplies for enhanced mains
input conditions rated to overvoltage category OVC III from 90VAC up to 305VAC with an extra wide
operating temperature range from -40°C to +90°C. These modules are designed to supply worldwide
applications in automation, Industry 4.0, IoT, household and smart buildings. For worldwide use they
come with international safety certifications for industrial, domestic and ITE as well as household
standards. With both PCB-mount and wired packages, fully protected outputs, and EMC class B
emissions compliance without any external components, these are the easiest to use modular power
solutions in the industry.
AC/DC Converter
y
• Wide input range 85-305VAC
• Standby mode optimized (eco design Lot 6)
• Overvoltage category OVC III (2000m)
• Operating temperature range: -40°C to +90°C
• Overvoltage and overcurrent protected
• EMC compliant without external components
• Encapsulated module with pins or wired
Features
Selection Guide
Part
Input
Output
Output
Efficiency
Max. Capacitive
Number
Voltage Range
Voltage
Current
typ (1) Load (2)
[VAC] [VDC] [mA] [%]
[µF]
RAC05-3.3SK/277 85-305 3.3
1510
77
10000
RAC05-05SK/277 85-305 5
1000 80
8000
RAC05-12SK/277 85-305 12
416
83
1500
RAC05-15SK/277 85-305 15
330
83
1000
RAC05-24SK/277 85-305 24
210
84
330
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Max Cap Load is tested at nominal input and full resistive load
Model Numbering
RE
TS
compliant
M
C
TS
S
C
R
RE
T
ERP
compliant
LOT6
PL
U
D
IA N
T PRO
SEHO
LD
H
CONVER
Single Output
Single Output
Single Output
Single Output
THT version
THT version
Wired version
Wired version
REV.: 5/2022
es
EN-60335-1
pp
a
www.recom-power.com
5 Watt 5Vout
5 Watt 24Vout
5 Watt 5Vout
5 Watt 12Vout
OU
M
E
PL
U
D
IA N
T PRO
O
REACH
CO
10 from 10
C
CERTIFIED
Notes:
Note3: add suffix „W“ for wired version
without suffix, standard THT version
Ordering Examples:
RAC05-05SK/277
RAC05-24SK/277
RAC05-05SK/277/W
RAC05-12SK/277/W
T
S
Single
CONVER
RoHS 2 +
compliant
M
Output Voltage
M
R
Wired
O
CO
nom. Output Power
C
E
RAC05-__ SK/277/W
lianc
E224736
UL62368-1 certified
EN62368-1 certified
IEC/EN60335-1 certified
EN62233 certified
IEC/EN61558-1 certified
IEC/EN61558-2-16 certified
EN55032 compliant
EN55014-1(-2) compliant
CB Report
PA-1
RAC05-K/277
Series
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Max.
nom. Vin = 277VAC
85VAC
120VDC
277VAC
305VAC
430VDC
150mA
100mA
75mA
15A
30A
35A
Internal Input Filter
Pi type
Input Voltage Range (4,5)
115VAC
230VAC
277VAC
Input Current
Inrush Current
115VAC
230VAC
277VAC
cold start at +25°C
No Load Power Consumption
100mW
Input Frequency Range
47Hz
ErP Lot 6 Standby Mode Conformity
(Output Load Capability)
Input Power=
0.5W
1.0W
0.34W
0.70W
Minimum Load
0%
0.60
0.45
0.40
115VAC
230VAC
277VAC
Power Factor
63Hz
Start-up Time
20ms
Rise Time
10ms
Hold-up Time
Internal Operating Frequency
Output Ripple and Noise
20ms
60ms
80ms
115VAC
230VAC
277VAC
100% load at nominal Vin
20MHz BW
(6)
130kHz
3.3, 5Vout
others
60mVp-p
1% of Vout
Notes:
Note4: The products were submitted for safety files at AC-Input operation
Note5: Refer to „Line Derating“
Note6: Measurements are made with a 0.1µF MLCC & 10µF E-cap in parallel across output. (low ESR)
Efficiency vs. Load
RAC05-12SK/277
100
100
90
90
80
80
70
70
Efficiency [%]
Efficiency [%]
RAC05-05SK/277
60
50
40
115VAC
230VAC
277VAC
30
60
50
40
30
20
20
10
10
0
0
10
20
30
40
50
60
70
80
90
0
100
Output Load [%]
www.recom-power.com
115VAC
230VAC
277VAC
0
10
20
30
40
50
60
70
80
90
100
Output Load [%]
REV.: 5/2022
PA-2
RAC05-K/277
Series
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
REGULATIONS
Parameter
Condition
Value
Output Accuracy
±1.0% typ.
Line Regulation
Load Regulation (7)
Transient Response
low line to high line, full load
±0.5% typ.
10% to 100% load
1.0% typ.
25% load step change
4.0% max.
recovery time
500µs typ.
Notes:
Note7: Operation below 10% load will not harm the converter, but specifications may not be met
Deviation vs. Load
RAC05-05SK/277
RAC05-12SK/277
1
1
0.5
0.5
Deviation [%]
Deviation [%]
(at 115VAC, 230VAC, 277VAC)
0
-0.5
-1
0
-0.5
0
10
20
30
40
50
60
70
80
90
-1
100
0
10
20
30
Output Load [%]
40
50
60
70
80
90
100
Output Load [%]
PROTECTIONS
Parameter
Input Fuse
Type
Value
internal
(8)
Short Circuit Protection (SCP)
T1A, slow blow
below 100mW
hiccup, automatic restart
Over Voltage Protection (OVP)
125% - 195%, latch of mode
according to 62368-1; -2-16
according to 61558-1; 2-16 (3rd Edition)
Over Voltage Category
Over Current Protection (OCP)
125% - 195%, hiccup mode
Class II
Class of Equipment
Isolation Voltage (safety certified)
Isolation Resistance
OVCII (5000m)
OVCIII (2000m)
1 minute
4.2kVAC
Isolation Voltage 500VDC
1GΩ min.
(9)
I/P to O/P
Isolation Capacitance
100pF max.
Insulation Grade
reinforced
Leakage Current
0.25mA max.
Notes:
Note8: Refer to local safety regulations if input over-current protection is also required
Note9: For repeat Hi-Pot testing, reduce the time and/or the test voltage
continued on next page
www.recom-power.com
REV.: 5/2022
PA-3
RAC05-K/277
Series
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Peak Load Capability
Pnom
PP
P r
t1
t 2
Pout [%]
Pnom = please refer to derating graph
PP = 1.2 x Pnom
t1 ≤ 30s
t2 ≥ 2 x t1
= nom. output power [W]
= peak output power [W]
= recovery power
[W]
= peak time
[s]
= recovery time [s]
Pp
Pnom
Pr
Pnom x (t1 + t2) - PP x t1
t2
Pr =
Practical Example:
Pr =
5W (30s + 60s) - (6W x 30s)
60s
= 4.5W
t1
t2
Time [s]
ENVIRONMENTAL
Parameter
Condition
Value
full load
Operating Temperature Range
@ natural convection 0.1m/s
refer to „Derating Graph“
3.3Vout
-40°C to +70°C
5, 12Vout
-40°C to +75°C
15, 24Vout
-40°C to +80°C
3.3Vout
-40°C to +85°C
all others
-40°C to +90°C
Maximum Case Temperature
+95°C
Temperature Coefficient
0.05%/K
5000m (OVCII)
2000m (OVCIII)
Operating Altitude (10)
Operating Humidity
non-condensing
5% - 95% RH max.
Pollution Degree
PD2
Vibration
according to MIL-STD-202G
MTBF
10-500Hz, 2G 10min./1cycle, period 60min. each along x,y,z axis
according to MIL-HDBK-217F, G.B.
+25°C
+40°C
>2252 x 103 hours
>1806 x 103 hours
230VAC
+25°C
+70°C
125 x 103 hours
23 x 103 hours
277VAC
+25°C
+70°C
105 x 103 hours
18 x 103 hours
Design Lifetime
Notes:
Note10: Recognized by UL for safe operation up to 5000m. High altitude operation may impact the performance and lifetime.
Contact RECOM tech support for advice
Derating Graph
Line Derating
100
100
90
90
80
80
70
70
Output Load [%]
Output Load [%]
(@ Chamber and natural convection 0.1m/s)
60
50
40
3.3VDC
5, 12VDC
15, 24VDC
30
20
50
40
30
20
10
0
-40
60
10
-15
10
35
60
75 85
70 80 90
0
110
Ambient Temperature [°C]
www.recom-power.com
85
90
305
Input Voltage [VAC]
REV.: 5/2022
PA-4
RAC05-K/277
Series
AC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report / File Number
Audio/Video, information and communication technology equipment - Part 1: Safety
requirements
Audio/Video, information and communication technology equipment Part 1: Safety requirements (CB Scheme)
Audio/Video, information and communication technology equipment Part 1: Safety requirements (LVD)
Household and similar electrical appliances - Safety Part 1: General requirements
Measurement methods for electromagnetic fields of household appliances and similar
apparatus with regard to human exposure
Safety of power transformers, power supplies, reactors and similar products for supply
voltages up to 1100 V (CB Scheme)
Safety of power transformers, power supplies, reactors and similar products for supply
voltages up to 1100 V
Safety of power transformers, power supplies, reactors and similar products for supply
voltages up to 1100 V (CB Scheme)
Safety of power transformers, power supplies, reactors and similar products for supply
voltages up to 1100 V Part 2: Particular requirements (CB Scheme)
Safety of power transformers, power supplies, reactors and similar products for supply
voltages up to 1100 V
Safety of power transformers, power supplies, reactors and similar products for supply
voltages up to 1100 V Part 2: Particular requirements
EAC
E491408-A6004-UL
Standard
UL62368-1, 2nd Edition, 2014-12-01
CAN/CSA-C22.2 No. 62368-1-14, 2nd Edt., 2014-12
IEC62368-1:2014 2nd Edition
E491408-A6007-CB-1
EN62368-1:2014 + A11:2017
LCS190308001CS
IEC60335-1:2010 + A2:2016 + C1:2016, 5th Edt.
EN60335-1:2012 + A13:2017
EN62233:2008
IEC61558-1:2005 2nd Edition + A1:2009
50230493 001
EN61558-1:2005 + A1:2009
IEC61558-1:2017 3rd Edition
CN21A36O-001
IEC61558-2-16:2009+A1:2013 1st Edition
EN IEC 61558-1:2019
CN222ZY2-001
EN61558-2-16:2009+A1:2013
RU-AT.03.67361
RoHS2
TP TC 004/2011
RoHS-2011/65/EU + AM-2015/863
EMC Compliance
Conditions
Standard / Criterion
Low-voltage power supplies DC output - Part 3: Electromagnetic compatibility
EN61204-3: 2018, Class B
Electromagnetic compatibility of multimedia equipment - Emission requirements (11)
EN55032:2015, Class B
Electromagnetic compatibility - Requirements for household appliances, electric tools
and similar apparatus - Part 1: Emission
EN55014-1:2006 + A2:2011
Information technology equipment - Immunity characteristics - Limits and methods of measurement
EN55024:2010 + A1:2015
Electromagnetic compatibility - Requirements for household appliances, electric tools
and similar apparatus - Part 2: Immunity
EN55014-2:2015
Air: ±2, 4, 8kV
Contact: ±2, 4kV
10V/m, 80MHz-1GHz
3V/m, 1.4GHz-2GHz
1V/m, 2GHz-2.7GHz
AC and DC Port: ±2kV
AC In Port (L-N): ±1kV
DC Output Port: ±0.5kV
AC and DC Port: 10V
ESD Electrostatic discharge immunity test
Radiated, radio-frequency, electromagnetic field immunity test
Fast Transient and Burst Immunity
Surge Immunity
Immunity to conducted disturbances, induced by radio-frequency fields
Power Magnetic Field Immunity
50Hz, 30A/m
Voltage Dips: 30%
Voltage Dips: 60%
Voltage Dips: 100%
Interruptions: >95%
Voltage Dips and Interruptions