RAC05E-24SK

RAC05E-24SK

  • 厂商:

    RECOM

  • 封装:

    DIP5模块

  • 描述:

    AC/DC CONVERTER 24V 5W

  • 数据手册
  • 价格&库存
RAC05E-24SK 数据手册
Features • • • • • • Regulated Converter 100-240VAC Input Primary side regulated Standard industry pinout Full load operation: -25 to 55°C No load power consumption 40 x 103 hours Derating Graph (@ Chamber and natural convection 0.1m/s) 100 90 Output Load [%] 80 70 60 50 40 30 20 10 0 -25 -20 -10 0 10 20 30 40 50 Ambient Temperature [°C] www.recom-power.com REV.: 0/2021 55 60 70 75 80 PA-4 RAC05E-K AC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin= 230VAC, full load and after warm-up unless otherwise stated) SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report Number Audio/Video, information and communication technology equipment - Part 1: Safety requirements Audio/Video, information and communication technology equipment - Safety requirements (CB Scheme) Audio/Video, information and communication technology equipment - Safety requirements (LVD) E491408-A6016-UL IEC62368-1:2014 2nd Edition E491408-A6015-IT-1 EN62368-1:2014 + A11:2017 IEC60335-1:2010 5th Edition + C1:2016 LCS200820072AS Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure Safety of power transformers, power supplies, reactors and similar products for supply voltages up to 1100 V (CB Scheme) Safety of power transformers, power supplies, reactors & similar products for supply voltages up to 1100 V Part 2: Particular requirements (CB Scheme) Safety of power transformers, power supplies, reactors and similar products for supply voltages up to 1100 V Safety of power transformers, power supplies, reactors & similar products for supply voltages up to 1100 V Part 2: Particular requirements UL62368-1:2014 CAN/CSA-C22.2 No. 62368-1:2014 E491408-A6017-CB-1 Household and similar electrical appliances – Safety – Part 1: General requirements (CB Scheme) Household and similar electrical appliances – Safety – Part 1: General requirements (LVD) Standard EN60335-1:2012 + A11:2014+A13:2017+A1 :2019+A2:2019+A14:2019 EN62233:2008 IEC61558-1:2005 2nd Edition + A1:2009 NN20TGSJ-001 IEC61558-2-16:2009 1st Edition + A1:2013 EN61558-1:2005 + A1:2009 NN20UK56-001 EN61558-2-16:2009 + A1:2013 RoHS2 RoHS 2011/65/EU + AM2015/863 EMC Compliance (Industrial) Condition Electromagnetic compatibility of multimedia equipment - Emission requirements Electromagnetic compatibility of multimedia equipment – Immunity requirements EN55035:2017 Air: ± 2, 4, 8kV Contact: ±2, 4kV 3V/m: 80-1000MHz 1800MHz, 2600MHz 3500MHz, 5000MHz ESD Electrostatic Discharge Immunity Test Radiated, Radio-Frequency, Electromagnetic Field Immunity Test Fast Transient and Burst Immunity Standard / Criterion EN55032:2015, Class A/B AC Port: ±1kV IEC61000-4-2:2008, Criteria B EN61000-4-2:2009, Criteria B IEC/EN61000-4-3:2006+A2:2010, Criteria A IEC/EN61000-4-4:2012, Criteria B Surge Immunity AC Power Port: ±1kV IEC61000-4-5:2014, Criteria B EN61000-4-5:2014+A1:2017, Criteria B Immunity to Conducted Disturbances, Induced by Radio-Frequency Fields 3Vrms: 0.15-10MHz 3-1Vrms: 10-30MHz 1Vrms: 30-80MHz IEC61000-4-6:2013, Criteria A EN61000-4-6:2014+AC:2015, Criteria A Power Magnetic Field Immunity IEC61000-4-8:2009, Criteria A EN61000-4-8:2010, Criteria A 1A/m 100% IEC61000-4-11:2004, Criteria B EN61000-4-11:2004+A1:2017, Criteria B 30% IEC61000-4-11:2004, Criteria C EN61000-4-11:2004+A1:2017, Criteria C 100% IEC61000-4-11:2004, Criteria C EN61000-4-11:2004+A1:2017, Criteria C Voltage Dips: Voltage Dips and Interruption Interruptions: EMC Compliance (Low Voltage PSU) Condition Low voltage power supplies, d.c. output Part 3: Electromagnetic compatibility (EMC) Air: ± 2, 4, 8kV Contact: ±2, 4kV ESD Electrostatic Discharge Immunity Test Standard / Criterion EN IEC 61204-3:2018, Class A/B IEC61000-4-2:2008, Criteria B EN61000-4-2:2009, Criteria B continued on next page www.recom-power.com REV.: 0/2021 PA-5 RAC05E-K AC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin= 230VAC, full load and after warm-up unless otherwise stated) EMC Compliance (Low Voltage PSU) Condition 10V/m: 80-1000MHz 3V/m: 1400-2000MHz 1V/m: 2000-2700MHz Radiated, Radio-Frequency, Electromagnetic Field Immunity Test Fast Transient and Burst Immunity AC Port: ±2kV Standard / Criterion IEC/EN61000-4-3:2006+A2:2010, Criteria A IEC/EN61000-4-4:2012, Criteria B Surge Immunity AC Power Port: ±1kV IEC61000-4-5:2014, Criteria B EN61000-4-5:2014+A1:2017, Criteria B Immunity to Conducted Disturbances, Induced by Radio-Frequency Fields 10Vrms: 0.15-80MHz IEC61000-4-6:2013, Criteria A EN61000-4-6:2014+AC:2015, Criteria A Power Magnetic Field Immunity IEC61000-4-8:2009, Criteria A EN61000-4-8:2010, Criteria A 30A/m Voltage Dips: Voltage Dips and Interruption Interruptions: Limits of Voltage Fluctuations & Flicker 100% (0.5P; 1.0P) IEC61000-4-11:2004, Criteria B EN61000-4-11:2004+A1:2017, Criteria B 20%, 30%, 60% IEC61000-4-11:2004, Criteria C EN61000-4-11:2004+A1:2017, Criteria C 100% IEC61000-4-11:2004, Criteria C EN61000-4-11:2004+A1:2017, Criteria C EN61000-3-3:2013+A1:2019 Limitations on the amount of electromagnetic interference allowed from digital and electronic devices FCC 47 CFR Part 15 Subpart B, Class B Limitations on the amount of electromagnetic interference allowed from digital and electronic devices, industrial, scientific, and medical equipment FCC 47 CFR Part 18 DIMENSION AND PHYSICAL CHARACTERISTICS Parameter Material Type case/baseplate potting PCB Dimension (LxWxH) Value black plastic, (UL94 V-0) PU, (UL94 V-0) FR4, (UL94 V-0) 37.0 x 24.0 x 18.0mm Weight 26.4g typ. continued on next page www.recom-power.com REV.: 0/2021 PA-6 RAC05E-K AC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin= 230VAC, full load and after warm-up unless otherwise stated) Dimension Drawing (mm) 37.0 General tolerances according to ISO 2768-m (table for reference only) 24.0 embossed logo Dimension range 0.5 - 6 mm 6 - 30 mm 30 - 120 mm 120 - 400 mm 23.3 36.3 18.0 Pinning Information Pin # Single 1 VAC in (L) 2 VAC in (N) 3 NC 4 -Vout 5 +Vout NC= no connection Recommended Footprint Details 3 Bottom View 5 4 7 x 2.54 = 17.78 2 5 4 Top View 1 2 3 2.54 2.54 3.11 10 x 2.54 = 25.40 5.08 1 4.0±1.0 0.60±0.05 3.26 Tolerances ±0.1 mm ±0.2 mm ±0.3 mm ±0.5 mm restricted area for PCB layout 10.16mm 5.08 PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) tube 490.0 x 26.6 x 25.3mm Packaging Quantity 12pcs The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV.: 0/2021 PA-7
RAC05E-24SK 价格&库存

很抱歉,暂时无法提供与“RAC05E-24SK”相匹配的价格&库存,您可以联系我们找货

免费人工找货
RAC05E-24SK
    •  国内价格
    • 12+69.75193

    库存:0

    RAC05E-24SK
    •  国内价格 香港价格
    • 12+60.9946812+7.36290
    • 24+59.5723124+7.19120
    • 36+58.1499336+7.01950
    • 60+56.2255560+6.78720
    • 84+54.3848384+6.56500

    库存:0

    RAC05E-24SK
      •  国内价格 香港价格
      • 12+52.5616412+6.37633
      • 24+52.3160224+6.34653
      • 48+52.3148648+6.34639
      • 60+52.3137160+6.34625
      • 180+52.31255180+6.34611

      库存:0