RAC20-15SK

RAC20-15SK

  • 厂商:

    RECOM

  • 封装:

    插件,52.5x27.4mm

  • 描述:

    RAC20-K系列是高效的PCB安装电源转换模块,具有超低功耗模式操作,适用于物联网和智能应用。该电源供应单元覆盖全球主电源输入范围85VAC至305VAC,并符合工业、音频视频和信息技术设备以及家用...

  • 数据手册
  • 价格&库存
RAC20-15SK 数据手册
• Wide input range 85-264VAC / 85-305VAC • Standby mode optimized PSU (ENER Lot 6) • Operating Altitude up to 5000m • Operating temperature range: -40°C to +85°C • Class II installations (without FG) • EMC compliant without external components • No load power consumption 40mW typ. Features Regulated Converter Description The RAC20-K series are highly efficient PCB-mount power conversion modules with ultra-low energy losses especially in light load conditions, making them a benchmark for always-on and standby mode operations, which are typically coming along with IoT and smart applications. The power supply units cover worldwide mains input range of 85VAC up to 305VAC and come with international safety certifications for industrial, AV and ITE as well as household standards. These AC/DC modules operate in a temperature range of -40°C to +85°C with up to 5000m operating altitude and offer fully protected single or dual outputs as well as EMC class B compliance without the need of any external components in floating connections. Modified versions for OVC III requirements are available on request. AC/DC Converter RAC RAC20-K 20 Watt 2“ x 1“ Single and Dual Output 3 Selection Guide Part Input Output Output Efficiency Max. Capacitive Number Voltage Range Voltage Current typ (1) Load (2) [VAC] [VDC] [mA] [%] [µF] RAC20-05SK (3,4) 85-264 / 85-305 5 4000 84 10000 RAC20-12SK (3,4) 85-264 / 85-305 12 1670 86 8000 RAC20-15SK (3,4) 85-264 / 85-305 15 1333 86 1500 RAC20-24SK (3,4) 85-264 / 85-305 24 830 85 1000 RAC20-48SK (3) 85-264 48 410 85 330 RAC20-12DK (3) 85-264 / 85-305 ±12 ±833 84 ±1200 RAC20-15DK (3) 85-264 / 85-305 ±15 ±670 84 ±1000 Notes: Note1: Efficiency is tested at 230VAC input and constant resistive load at +25°C ambient Note2: Max Cap Load is tested at nominal input and full resistive load Model Numbering K/277/W on request 24 x x on request 48 N/A x on request 12D x N/A N/A 15D x N/A N/A x = standard portfolio / on request = MOQ may apply on project base / N/A= not available www.recom-power.com REV.: 8/2022 RE H compliant M TS TS C REACH P ERP compliant LOT6 C RE x T S x CO NVE R R on request 15 OU U M E on request x D IA N T PRO O CO x x PL C U LIA D N T PRO S E HO LD x M CERTIFIED EN-60335-1 pp a 5 12 10 from 10 CO Notes: Note3: Add suffix “/277” for wider input voltage range (85-305VAC) For detail information refer to “Nominal Input Voltage (5, 6)” without suffix= standard input range 85-264VAC Note4: Add suffix „W“ for wired version (single output only, “277/W” combination on request) without suffix= standard THT version refer to “Model Matrix” Model Matrix Model /277 /W /277/W T RoHS 2 + compliant (3) Single or Dual C O N V ER M S Input Voltage option O R Output Voltage C E Wired option (4) nom. Output Power es RAC20- lianc E224736 IEC/EN62368-1 certified UL62368-1 certified CAN/CSA-C22.2 No. 62368-1-14 certified IEC/EN60335 certified IEC/EN61558-1 certified IEC/EN61558-2-16 certified IEC/EN61204-3 compliant EN55032/14 compliant EN55024 compliant CB Report PA-1 RAC20-K AC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Internal Input Filter Pi type 50/60Hz Nominal Input Voltage (5, 6) standard version “/277” version 100VAC 47-63Hz DC 47-63Hz DC 85VAC 120VDC 85VAC 120VDC standard Operating Range /277 Versions 240VAC 277VAC 264VAC 370VDC 305VAC 430VDC 115VAC 230VAC 277VAC Input Current Inrush Current cold start at +25°C No Load Power Consumption 450mA 400mA 300mA 115VAC 230VAC 277VAC 20A 40A 50A 230VAC 40mW 0.5W Input Power = 1.0W 2.0W ErP Lot 6 Standby Mode Conformity (Output Load Capability) Input Frequency Range Minimum Load (9) 0.3W 0.7W 1.6W AC Input 47Hz single dual (required for regulation on both outputs) 0% 115VAC 230VAC 277VAC 0.6 0.5 0.45 Power Factor 63Hz 10% Start-up Time 150ms Rise Time 40ms 115VAC 230VAC 277VAC Hold-up Time 12ms 60ms 90ms Internal Operating Frequency 100kHz Output Ripple and Noise (7) 5Vout others 20MHz BW 100mVp-p 1% of Vout Notes: Note5: The products were submitted for safety files at AC-Input operation Note6: Refer to “Derating Graph” Note7: Measurements are made with a 1.0µF MLCC across output (low ESR) RAC20-05SK(W) RAC20-12SK(W) 100 100 90 90 80 80 70 70 Efficiency [%] Efficiency [%] Efficiency vs. Load 60 50 40 30 115VAC 230VAC 277VAC 20 10 0 60 50 40 30 115VAC 230VAC 277VAC 20 10 0 10 20 30 40 50 60 Output Load [%] www.recom-power.com 70 80 90 0 100 continued on next page REV.: 8/2022 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] PA-2 RAC20-K AC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) RAC20-15DK RAC20-24SK(W) 100 100 90 90 80 80 70 70 Efficiency [%] Efficiency [%] Efficiency vs. Load 60 50 40 30 50 40 30 115VAC 230VAC 277VAC 20 10 0 60 0 10 20 30 40 50 60 70 80 90 115VAC 230VAC 277VAC 20 10 0 100 0 10 20 30 Output Load [%] 40 50 60 70 80 90 100 Output Load [%] REGULATIONS Parameter Condition Value Output Accuracy ±2.0% typ. Line Regulation low line to high line ±0.5% typ. Load Regulation (8) 10% to 100% load 2.0% typ. Cross Regulation dual output only ±10.0% typ. 25% load step change recovery time Transient Response 4.0% max. 500µs typ. Notes: Note8: Operation below 10% load will not harm the converter, but specifications may not be met Deviation vs. Load RAC20-05SK(W) 2 1.5 0.5 0 -0.5 0.5 0 -0.5 -1 -1 -1.5 -1.5 0 10 20 30 40 50 60 70 80 90 115VAC 230VAC 277VAC 1 Deviation [%] Deviation [%] 1.5 115VAC 230VAC 277VAC 1 -2 RAC20-12SK(W) 2 -2 100 0 10 20 30 Output Load [%] RAC20-15SK(W) 2 0 -0.5 -1 50 60 70 80 90 -2 100 Output Load [%] www.recom-power.com 100 115VAC 230VAC 277VAC -0.5 -1.5 40 90 0 -1 30 80 0.5 -1.5 20 70 1 Deviation [%] Deviation [%] 0.5 10 60 1.5 115VAC 230VAC 277VAC 1 0 50 RAC20-24SK(W) 2 1.5 -2 40 Output Load [%] 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] REV.: 8/2022 PA-3 RAC20-K AC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) PROTECTIONS Parameter Type Input Fuse (9) Value standard version internal T3.15A, slow blow type non, refer to “Protection Circuit” /277 versions Short Circuit Protection (SCP) below 100mW hiccup, auto recovery Over Voltage Protection (OVP) 150% - 195%, latch off mode Over Current Protection (OCP) 110% - 130%, hiccup mode Over Voltage Category OVCII (10) Class of Equipment Class II Isolation Voltage (11) Isolation Resistance tested for 1 minute I/P to O/P 3kVAC Viso = 500VDC 1GΩ min. Isolation Capacitance 100pF max. Insulation Grade reinforced Leakage Current 0.25mA max. Notes: Note9: Refer to local safety regulations if input over-current protection is also required /277 Versions have no fuse integrated, it is recommended to use an external fuse recognized by UL or evaluated by TUV, refer to below schematic Note10: For OVC III requirements please contact RECOM tech support for advice Note11: For repeat Hi-Pot testing, reduce the time and/or the test voltage Protection Circuit for /277 Versions L N F VACin (L) +Vout VACin(N) -Vout +Vout -Vout ENVIRONMENTAL Parameter Operating Temperature Range Condition @ natural convection 0.1m/s Value full load -40°C to +55°C refer to “Derating Graph” -40°C to +85°C Maximum Case Temperature +95°C Temperature Coefficient 0.05%/K 5000m Operating Altitude (12) Operating Humidity non-condensing 20% - 90% RH max. IP Rating IP20 Pollution Degree PD2 Vibration according to MIL-STD-202G Design Lifetime MTBF 10-500Hz, 2G 10min./1cycle, period 60min. along x,y,z axes +25°C 130 x 10³ hours +55°C 16 x 10³ hours according to MIL-HDBK-217F, G.B. +25°C +40°C >1196 x 103 hours >955 x 103 hours Notes: Note12: Recognized by safety agency for safe operation up to 5000m. High altitude operation may impact the performance and lifetime. Please contact RECOM tech support for advice continued on next page www.recom-power.com REV.: 8/2022 PA-4 RAC20-K AC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) Derating Graph 100 (@ Chamber and natural convection 0.1m/s) 90 Output Load [%] 80 70 60 50 40 30 20 10 0 -40 -20 0 20 40 60 55 80 Ambient Temperature [°C] 85 100 Notes: Note13: Output power derating for Line-input of less than 90VAC (de-rate linearly from 100% at 90VAC to 90% at 85VAC) SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Audio/Video, information and communication technology equipment Safety requirements E224736 Audio/Video, information and communication technology equipment Safety requirements (CB Scheme) Standard UL62368-1, 2nd Edition, 2014 CAN/CSA C22.2 Nr. 62368-1-14, 2nd Ed. 2014 IEC62368-1:2014 2nd Edition E491408-A6008-CB-1 Audio/Video, information and communication technology equipment Safety requirements (LVD) EN62368-1:2014 + A11:2017 Household and similar electrical appliances – Safety – Part 1: General requirements Safety of power transformers, power supplies, reactors and similar products for supply voltages up to 1100 V (CB Scheme) Safety of power transformers, power supplies, reactors and similar products for supply voltages up to 1100 V Safety of power transformers, power supplies, reactors and similar products for supply voltages up to 1100 V Part 2: Particular requirements (CB Scheme) Safety of power transformers, power supplies, reactors and similar products for supply voltages up to 1100 V Part 2: Particular requirements Safety requirements for power electronic converter systems and equipment - Part 1: General (CB Scheme) Safety requirements for power electronic converter systems and equipment - Part 1: General (LVD) EAC LCS180508046AS IEC60335-1:2010 + AMD2:2016 + COR1:2016 EN60335-1:2012 + A11:2014 + A13:2017 IEC61558-1:2005 2nd Edition + A1:2009 50198090 001 EN61558-1:2005 + A1:2009 IEC61558-2-16:2009 1st Edition + A1:2013 50198090 001 EN61558-2-16:2009 + A1:2013 IEC62477-1:2012 + A1:2016, 1st Edition CN21R4QC001 EN62477-1:2012 + A11:2014 + A1:2017 RU-AT.03.67361 RoHS2 TP TC 004/2011 RoHS-2011/65/EU + AM-2015/863 EMC Compliance Condition Low voltage power supplies, d.c. output Part 3: Electromagnetic compatibility (EMC) Electromagnetic compatibility of multimedia equipment - Emission requirements Standard / Criterion IEC/EN61204-3:2018, Class B without external filter Electromagnetic compatibility of household appliances, electric tools and similar apparatus - Emission Requirements Information technology equipment - Immunity characters - Limits and methods of measurement EN55032:2015, Class B EN55014-1:2006 + A2:2011 EN55024:2010 + A1:2015 continued on next page www.recom-power.com REV.: 8/2022 PA-5 RAC20-K AC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) EMC Compliance Condition Standard / Criterion Electromagnetic compatibility of household appliances, electric tools and similar apparatus - Immunity Requirements EN55014-2:2015 ESD Electrostatic discharge immunity test Air ±8kV, Contact ±4kV EN61000-4-2:2009, Criteria B Radiated, radio-frequency, electromagnetic field immunity test 80MHz - 6GHz: 10V/m 1.4GHz - 2GHz: 3V/m 2.0GHz - 2.7GHz: 1V/m EN61000-4-3:2006 + A1:2008, Criteria A AC Port: ±2.0kV DC Port: ±2.0kV Fast Transient and Burst Immunity AC Port: L-N ±1.0kV DC Port: ±0.5kV Surge Immunity EN61000-4-4:2012, Criteria B EN61000-4-5:2014 + A1:2017, Criteria B Immunity to conducted disturbances, induced by radio-frequency fields AC Port: 10V DC Port: 10V EN61000-4-6:2014, Criteria A Power Magnetic Field Immunity 50Hz, 30A/m EN61000-4-8:2010, Criteria A Voltage Dips and Interruptions Voltage Dips 20% Voltage Dips 30% Voltage Dips 60% Voltage Dips 100% Voltage Interruptions > 95% EN61000-4-11:2004 + A1:2017, Criteria C EN61000-4-11:2004 + A1:2017, Criteria C EN61000-4-11:2004 + A1:2017, Criteria C EN61000-4-11:2004 + A1:2017, Criteria B EN61000-4-11:2004 + A1:2017, Criteria C Limits of Voltage Fluctuations & Flicker EN61000-3-3:2013 Limitations on the amount of electromagnetic interference allowed from digital and electronic devices FCC 47 CFR Part 15 Subpart B, Class B American National Standard for Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz ANSI C63.4-2014, Class B Notes: Note14: If output is connected to GND, please contact RECOM tech support for advice DIMENSION AND PHYSICAL CHARACTERISTICS Parameter Material Type case potting PCB baseplate Dimension (LxWxH) Weight Value black plastic, (UL94V-0) silicone, (UL94V-0) FR4, (UL94V-0) black plastic, (UL94V-0) 52.5 x 27.4 x 23.0mm THT wired 60g typ. 65g typ. continued on next page www.recom-power.com REV.: 8/2022 PA-6 RAC20-K AC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) Dimension Drawing (mm) 52.5 27.4 embossed logo Pinning information 51.0 Pin # 1 2 3 4 5 23.0 26.3 Single VAC in (N) VAC in (L) no pin -Vout +Vout Dual VAC in (N) VAC in (L) -Vout Com +Vout Tolerance:  xx.x= ±0.5mm  xx.xx= ±0.25mm 20.32 6.0 ±1.0 Ø1.0 ±0.1 Recommended Footprint Details 1 3 5 10.16 2 5 10.16 3.50 1 2 18x2.54= 45.72 3.39 4 Top View 2. 54 4 Bottom View 3 2.54 Dimension Drawing Single Wired (mm) embossed logo 27.4 52.5 51.0 100.0±10 23.0 26.3 Wired information 5 ±2 # 1 2 4 5 Ø2.9 2 Function VAC in (N) VAC in (L) -Vout +Vout Wire color blue brown black red Type UL-1015 UL-1015 UL-1015 UL-1015 AWG 18 18 18 18 Tolerance: xx.x= ±0.5mm  xx.xx= ±0.25mm Bottom View 1 www.recom-power.com 4 5 REV.: 8/2022 PA-7 RAC20-K AC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) PACKAGING INFORMATION Parameter Packaging Dimension (LxWxH) Packaging Quantity Type pin wired tube tray tube tray Storage Temperature Range Storage Humidity Value 490.0 x 56.0 x 40.0mm 488.0 x 202.0 x 47.0mm 15pcs 20pcs -40°C to +85°C non-condensing 20% to 90% RH max. The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV.: 8/2022 PA-8
RAC20-15SK 价格&库存

很抱歉,暂时无法提供与“RAC20-15SK”相匹配的价格&库存,您可以联系我们找货

免费人工找货
RAC20-15SK
  •  国内价格
  • 4+103.87803
  • 8+101.79526

库存:17

RAC20-15SK
  •  国内价格
  • 1+106.00245
  • 4+103.87803
  • 8+101.79526

库存:17

RAC20-15SK
  •  国内价格
  • 1+124.57770
  • 5+110.51260
  • 10+105.41190
  • 25+100.76140

库存:17

RAC20-15SK
  •  国内价格
  • 1+1590.90106
  • 3+1559.08679
  • 6+1512.30783

库存:17