RAC35-24SG/OF

RAC35-24SG/OF

  • 厂商:

    RECOM

  • 封装:

    -

  • 描述:

    RAC35-xxG/OF系列是低成本的4英寸x2英寸AC/DC电源,具有通用输入电压范围90-264VAC。输出可调以补偿电缆损耗,并具有短路和过载保护。工作温度范围为-25°C至+65°C(降额)。...

  • 数据手册
  • 价格&库存
RAC35-24SG/OF 数据手册
!NOT RECOMMENDED FOR NEW DESIGNS! • Universal input 90-264VAC Features (LAST TIME BUY: 30TH NOV 2020) Regulated Converter Description RAC RAC35-G/OF 35 Watt 4“ x 2“ Open Frame YEA R 3 arrant w The RAC35-xxG/OF series are low cost, 4”x2” AC/DC power supplies with universal input (90-264VAC) and fully protected and isolated DC outputs in the range of 5V up to 48V. The converters are offered in open frame (/OF) version. The outputs are trimmable to compensate for cable losses and are short circuit and overload protected. The converters work over a wide temperature range of -25°C to +65°C (with derating), are UL60950, EN60950 and CE certified and comply with Class B EMC limits. The RAC35-G series come with a three year warranty. AC/DC Converter y • Efficiency up to 86% • Short circuit and over voltage/current protected • UL/EN60950 certified, CE marked • Conformal coated product D IA N T PRO CO NVE R T REACH compliant M TS TS U M P C PL C M O S 10 from 10 C R RE T RoHS 2 + compliant E nom. Output Voltage Single C O N V ER CO RAC35-__ SG/OF M S Model Numbering O R Notes: Note1: Efficiency is tested at nominal input and full load at +25°C ambient C E Input Output max. Output Efficiency Voltage Range Voltage Current typ. (1) [VAC] [VDC] [mA] [%] 90-264 5 6000 78 90-264 12 3000 81 90-264 24 1500 83 90-264 48 750 86 CO Part Number RAC35-05SG/OF RAC35-12SG/OF RAC35-24SG/OF RAC35-48SG/OF RE Selection Guide U LIA D N T PRO E196683 UL60950 certified CAN/CSA C22.2 N.60950-1-07 certified EN60950-1 certified EN55032 compliant EN55024 compliant PREFERRED ALTERNATIVES Case Style Please consider these alternatives: RACM60-K Series Ordering Examples: RAC35-24SG/OF RAC35-12SG/OF www.recom-power.com 24Vout 12Vout Single Single open frame version open frame version REV.: 4/2020 PA-1 ! NOT RECOMMENDED FOR NEW DESIGNS ! (LAST TIME BUY: 30TH NOV 2020) RAC35-G/OF AC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin and full load unless otherwise stated) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. 90VAC 230VAC 264VAC Output Power 36W Input Voltage Range 1A 0.6A 115VAC 230VAC Input Current Inrush Current 115VAC 230VAC cold start at 25°C No load Power Consumption 23A 45A 230VAC 0.5W Input Frequency Range 5Vout 12Vout 24Vout 48Vout Output Voltage Trimming Minimum Load 47Hz 63Hz 4.75VDC 11.4VDC 22.8VDC 45.6VDC 5.5VDC 13.2VDC 26.4VDC 52.8VDC 0% Power Factor 115VAC 230VAC 0.6 0.5 Start-up Time 115VAC 230VAC Rise Time 115VAC 230VAC 10ms 8ms Hold-up Time 115VAC 230VAC 10ms 20ms 2s 1s Internal Operating Frequency Output Ripple and Noise 65kHz 100kHz 20MHz BW (2) 200mVp-p Notes: Note2: Measurements are made with a 1.0µF & 10µF parallel capacitor Efficiency vs. Load RAC35-24SG/OF 100 90 90 80 80 70 70 Efficiency [%] Efficiency [%] RAC35-12SG/OF 100 60 50 90VAC 115VAC 230VAC 264VAC 40 30 20 50 90VAC 115VAC 230VAC 264VAC 40 30 20 10 0 60 10 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] 0 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] REGULATIONS Parameter Condition Value Output Accuracy ±1.0% typ. Line Regulation ±0.5% typ. Load Regulation www.recom-power.com 10%-100% load REV.: 4/2020 1.0% typ. PA-2 ! NOT RECOMMENDED FOR NEW DESIGNS ! (LAST TIME BUY: 30TH NOV 2020) RAC35-G/OF AC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin and full load unless otherwise stated) PROTECTIONS Parameter Type Input fuse Value internal T3.15A / 250V slow blow Short Circuit Protection (SCP) continuous, auto recovery Over Voltage Protection (OVP) 115-135% of Vout nominal Over Current Protection (OCP) 5VDC 12VDC 24VDC 48VDC Latch OFF 6.3 - 10.8A 3.15 - 5.4A 1.58 - 2.7A 0.78 - 1.35A Hiccup Mode, auto recovery Class of Equipment Isolation Voltage Isolation Resistance Class I 3kVAC 1.5kVAC 0.5kVDC 100MΩ min. I/P to O/P I/P to PE O/P to PE tested for 1 minute I/P to O/P Isolation Capacitance 2200pF max. Insulation Grade Leakage Current reinforced I/P to O/P O/P to FG 0.25mA max. 3.5mA max. Notes: Note3: Refer to local safety regulations if input over-current protection is also required ENVIRONMENTAL Parameter Condition Operating Temperature Range @ natural convection 0.1m/s Value full load -25°C to +50°C refer to derating graph -25°C to +65°C Temperature Coefficient ±0.03%/K typ. 5000m Operating Altitude (4) Operating Humidity non-condensing 20% - 90% RH max. Pollution Degree PD2 Conformal Coating provided Shock 20G, 11ms, 3 times for X,Y and Z axis MTBF according to MIL-HDBK-217F, G.B. +25°C 200 x 103 hours Notes: Note4: Recognized by UL for safe operation up to 5000m. High altitude operation may impact the performance and lifetime Contact RECOM techsupport for advice continued on next page www.recom-power.com REV.: 4/2020 PA-3 ! NOT RECOMMENDED FOR NEW DESIGNS ! (LAST TIME BUY: 30TH NOV 2020) RAC35-G/OF AC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin and full load unless otherwise stated) Operating Altitude (@ Chamber and natural convection 0.1m/s) (limitation E-Cap heitsink) 100 100 90 90 80 80 70 70 Output Load [%] Output Load [%] Derating Graph 60 50 40 60 50 40 30 30 20 20 10 10 0 -25 0 10 20 30 40 50 60 Ambient Temperature [°C] 65 70 80 0 +25°C Tamb +50°C Tamb 0 1000 2000 3000 4000 5000 6000 Operating Altitude [m] SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Information Technology Equipment, General Requirements for Safety E196683 Information Technology Equipment, General Requirements for Safety (LVD) SA1406027L01001 EAC Safety of Low Voltage Equipment RU-AT.49.09571 RoHS2+ Standard UL60950-1, 2nd Edition, 2014 CSA C22.2 No. 60950-1-07, 2nd Ed. 2014 EN60950-1, 2nd Edition, 2013 TP TC 004/2011 RoHS 2011/65/EU + AM2015/863 EMC Compliance Electromagnetic compatibility of multimedia equipment – Emission Requirements Conditions Standard / Criterion without external filter EN55032:2015, Class B Information technology equipment - Immunity characteristics - Limits and methods of measurement ESD Electrostatic discharge immunity test Radiated, radio-frequency, electromagnetic field immunity test Fast Transient and Burst Immunity Surge Immunity Immunity to conducted disturbances, induced by radio-frequency fields EN55024:2010 + A1:2015 ±8kV Air; ±4kV Contact EN61000-4-2, Criteria A 3V/m EN61000-4-3, Criteria A AC Power Port: ±1.0kV L-L ±1.0kV AC Power L-PE ±2.0kV Port: N-PE ±2.0kV EN61000-4-4, Criteria A EN61000-4-5, Criteria B AC Power Port: 3V EN61000-4-6, Criteria A Power Magnetic Field Immunity 50Hz, 1A/m Voltage Dips and Interruptions Dips: >95% reduction Interruption: >95% EN61000-4-8, Criteria A EN61000-4-11, Criteria A EN61000-4-11, Criteria C Limits of Harmonic Current Emissions Limits of Voltage Fluctuations & Flicker www.recom-power.com EN61000-3-2, Criteria A EN61000-3-3 REV.: 4/2020 PA-4 ! NOT RECOMMENDED FOR NEW DESIGNS ! (LAST TIME BUY: 30TH NOV 2020) RAC35-G/OF AC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin and full load unless otherwise stated) DIMENSION AND PHYSICAL CHARACTERISTICS Parameter Type Material PCB Value FR4 (UL94-V0) Dimension (LxWxH) 101.6 x 51.0 x 28.0mm Weight 126g typ. Dimension Drawing Open Frame (mm) 101.6 21.0 M3 T3.15 1 1 CN2 51.0 CN1 3 2 3 4 Trim Connections LED AC Input (CN1) Top View Pin # Terminal 1 AC/L 3 AC/N 3 Pins (Pin2 removed) with 3.96mm pitch 4.0 DC Output (CN2) Side View Pin # Terminal 1,2 V+ 3,4 V- 4 Pins with 3.96mm pitch FC = fixing centers Crimp Terminal AWG Range: 18-22AWG Tolerance: xx.x= ±1.0mm xx.xx= ±0.5mm 2.5 28.0 Customer Application Compatible Connectors Housing 3.5 4.0 PCB thickness=1.6mm Customer Application Landwin 3960S Series JST VHR Molex 51144 Series FC 44.3 Crimp Terminal Bottom View Landwin 3963T011R JST SVH-21T-P1.1 Molex 50539 3.15 FC 95.3 continued on next page www.recom-power.com REV.: 4/2020 PA-5 ! NOT RECOMMENDED FOR NEW DESIGNS ! (LAST TIME BUY: 30TH NOV 2020) RAC35-G/OF vertical DC AC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin and full load unless otherwise stated) APPLICATION and INSTALLATION Mounting horizontal (standard) AC AC horizontal (standard) DC DC AC If module is mounted vertical or upside-down with natural convection cooling, the power must be derated ≥ 10%. vertical vertical DC DC upside-down AC DC AC AC Block diagram L N T3.15A Input upside-down Filter PE DC DC OCP Limit +V Output Filter upside-down Power Stage -V AC AC LED Protection OVP ShutDown Outoput Voltage Regulation Vadj. PACKAGING INFORMATION Parameter Packaging Dimension (LxWxH) Type cardboard box Packaging Quantity 174.0 x 125.0 x 266.0mm 10pcs Storage Temperature Range Storage Humidity Value -40°C to +85°C non-condensing 10% - 95% RH max. The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV.: 4/2020 PA-6
RAC35-24SG/OF 价格&库存

很抱歉,暂时无法提供与“RAC35-24SG/OF”相匹配的价格&库存,您可以联系我们找货

免费人工找货
RAC35-24SG/OF
  •  国内价格 香港价格
  • 1+152.141421+19.68182

库存:0