!NOT RECOMMENDED FOR NEW DESIGNS!
• Universal input 90-264VAC
Features
(LAST TIME BUY: 30TH NOV 2020)
Regulated
Converter
Description
RAC
RAC35-G/OF
35 Watt
4“ x 2“
Open Frame
YEA R
3
arrant
w
The RAC35-xxG/OF series are low cost, 4”x2” AC/DC power supplies with universal input
(90-264VAC) and fully protected and isolated DC outputs in the range of 5V up to 48V. The converters
are offered in open frame (/OF) version. The outputs are trimmable to compensate for cable losses and
are short circuit and overload protected. The converters work over a wide temperature range of -25°C
to +65°C (with derating), are UL60950, EN60950 and CE certified and comply with Class B EMC limits.
The RAC35-G series come with a three year warranty.
AC/DC Converter
y
• Efficiency up to 86%
• Short circuit and over voltage/current protected
• UL/EN60950 certified, CE marked
• Conformal coated product
D
IA N
T PRO
CO NVE R
T
REACH
compliant
M
TS
TS
U
M
P
C
PL
C
M
O
S
10 from 10
C
R
RE
T
RoHS 2 +
compliant
E
nom. Output Voltage
Single
C O N V ER
CO
RAC35-__ SG/OF
M
S
Model Numbering
O
R
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
C
E
Input
Output
max. Output
Efficiency
Voltage Range
Voltage
Current
typ. (1)
[VAC] [VDC] [mA] [%]
90-264 5 6000 78
90-264 12 3000 81
90-264 24 1500 83
90-264 48 750 86
CO
Part
Number
RAC35-05SG/OF
RAC35-12SG/OF
RAC35-24SG/OF
RAC35-48SG/OF
RE
Selection Guide
U
LIA
D
N T PRO
E196683
UL60950 certified
CAN/CSA C22.2 N.60950-1-07 certified
EN60950-1 certified
EN55032 compliant
EN55024 compliant
PREFERRED ALTERNATIVES
Case Style
Please consider these alternatives:
RACM60-K Series
Ordering Examples:
RAC35-24SG/OF
RAC35-12SG/OF
www.recom-power.com
24Vout
12Vout
Single
Single
open frame version
open frame version
REV.: 4/2020
PA-1
! NOT RECOMMENDED FOR NEW DESIGNS !
(LAST TIME BUY: 30TH NOV 2020)
RAC35-G/OF
AC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin and full load unless otherwise stated)
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Max.
90VAC
230VAC
264VAC
Output Power
36W
Input Voltage Range
1A
0.6A
115VAC
230VAC
Input Current
Inrush Current
115VAC
230VAC
cold start at 25°C
No load Power Consumption
23A
45A
230VAC
0.5W
Input Frequency Range
5Vout
12Vout
24Vout
48Vout
Output Voltage Trimming
Minimum Load
47Hz
63Hz
4.75VDC
11.4VDC
22.8VDC
45.6VDC
5.5VDC
13.2VDC
26.4VDC
52.8VDC
0%
Power Factor
115VAC
230VAC
0.6
0.5
Start-up Time
115VAC
230VAC
Rise Time
115VAC
230VAC
10ms
8ms
Hold-up Time
115VAC
230VAC
10ms
20ms
2s
1s
Internal Operating Frequency
Output Ripple and Noise
65kHz
100kHz
20MHz BW
(2)
200mVp-p
Notes:
Note2: Measurements are made with a 1.0µF & 10µF parallel capacitor
Efficiency vs. Load
RAC35-24SG/OF
100
90
90
80
80
70
70
Efficiency [%]
Efficiency [%]
RAC35-12SG/OF
100
60
50
90VAC
115VAC
230VAC
264VAC
40
30
20
50
90VAC
115VAC
230VAC
264VAC
40
30
20
10
0
60
10
0
10
20
30
40
50
60
70
80
90
100
Output Load [%]
0
0
10
20
30
40
50
60
70
80
90
100
Output Load [%]
REGULATIONS
Parameter
Condition
Value
Output Accuracy
±1.0% typ.
Line Regulation
±0.5% typ.
Load Regulation
www.recom-power.com
10%-100% load
REV.: 4/2020
1.0% typ.
PA-2
! NOT RECOMMENDED FOR NEW DESIGNS !
(LAST TIME BUY: 30TH NOV 2020)
RAC35-G/OF
AC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin and full load unless otherwise stated)
PROTECTIONS
Parameter
Type
Input fuse
Value
internal
T3.15A / 250V slow blow
Short Circuit Protection (SCP)
continuous, auto recovery
Over Voltage Protection (OVP)
115-135% of Vout nominal
Over Current Protection (OCP)
5VDC
12VDC
24VDC
48VDC
Latch OFF
6.3 - 10.8A
3.15 - 5.4A
1.58 - 2.7A
0.78 - 1.35A
Hiccup Mode,
auto recovery
Class of Equipment
Isolation Voltage
Isolation Resistance
Class I
3kVAC
1.5kVAC
0.5kVDC
100MΩ min.
I/P to O/P
I/P to PE
O/P to PE
tested for 1 minute
I/P to O/P
Isolation Capacitance
2200pF max.
Insulation Grade
Leakage Current
reinforced
I/P to O/P
O/P to FG
0.25mA max.
3.5mA max.
Notes:
Note3: Refer to local safety regulations if input over-current protection is also required
ENVIRONMENTAL
Parameter
Condition
Operating Temperature Range
@ natural convection 0.1m/s
Value
full load
-25°C to +50°C
refer to derating graph
-25°C to +65°C
Temperature Coefficient
±0.03%/K typ.
5000m
Operating Altitude (4)
Operating Humidity
non-condensing
20% - 90% RH max.
Pollution Degree
PD2
Conformal Coating
provided
Shock
20G, 11ms, 3 times for X,Y and Z axis
MTBF
according to MIL-HDBK-217F, G.B.
+25°C
200 x 103 hours
Notes:
Note4: Recognized by UL for safe operation up to 5000m. High altitude operation may impact the performance and lifetime
Contact RECOM techsupport for advice
continued on next page
www.recom-power.com
REV.: 4/2020
PA-3
! NOT RECOMMENDED FOR NEW DESIGNS !
(LAST TIME BUY: 30TH NOV 2020)
RAC35-G/OF
AC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin and full load unless otherwise stated)
Operating Altitude
(@ Chamber and natural convection 0.1m/s)
(limitation E-Cap heitsink)
100
100
90
90
80
80
70
70
Output Load [%]
Output Load [%]
Derating Graph
60
50
40
60
50
40
30
30
20
20
10
10
0
-25
0
10
20
30
40
50
60
Ambient Temperature [°C]
65
70
80
0
+25°C Tamb
+50°C Tamb
0
1000
2000
3000
4000
5000
6000
Operating Altitude [m]
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report / File Number
Information Technology Equipment, General Requirements for Safety
E196683
Information Technology Equipment, General Requirements for Safety (LVD)
SA1406027L01001
EAC Safety of Low Voltage Equipment
RU-AT.49.09571
RoHS2+
Standard
UL60950-1, 2nd Edition, 2014
CSA C22.2 No. 60950-1-07, 2nd Ed. 2014
EN60950-1, 2nd Edition, 2013
TP TC 004/2011
RoHS 2011/65/EU + AM2015/863
EMC Compliance
Electromagnetic compatibility of multimedia equipment – Emission Requirements
Conditions
Standard / Criterion
without external filter
EN55032:2015, Class B
Information technology equipment - Immunity characteristics - Limits and methods of
measurement
ESD Electrostatic discharge immunity test
Radiated, radio-frequency, electromagnetic field immunity test
Fast Transient and Burst Immunity
Surge Immunity
Immunity to conducted disturbances, induced by radio-frequency fields
EN55024:2010 + A1:2015
±8kV Air; ±4kV Contact
EN61000-4-2, Criteria A
3V/m
EN61000-4-3, Criteria A
AC Power Port: ±1.0kV
L-L ±1.0kV
AC Power
L-PE ±2.0kV
Port:
N-PE ±2.0kV
EN61000-4-4, Criteria A
EN61000-4-5, Criteria B
AC Power Port: 3V
EN61000-4-6, Criteria A
Power Magnetic Field Immunity
50Hz, 1A/m
Voltage Dips and Interruptions
Dips: >95% reduction
Interruption: >95%
EN61000-4-8, Criteria A
EN61000-4-11, Criteria A
EN61000-4-11, Criteria C
Limits of Harmonic Current Emissions
Limits of Voltage Fluctuations & Flicker
www.recom-power.com
EN61000-3-2, Criteria A
EN61000-3-3
REV.: 4/2020
PA-4
! NOT RECOMMENDED FOR NEW DESIGNS !
(LAST TIME BUY: 30TH NOV 2020)
RAC35-G/OF
AC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin and full load unless otherwise stated)
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter
Type
Material
PCB
Value
FR4 (UL94-V0)
Dimension (LxWxH)
101.6 x 51.0 x 28.0mm
Weight
126g typ.
Dimension Drawing Open Frame (mm)
101.6
21.0
M3
T3.15
1
1
CN2
51.0
CN1
3
2
3
4
Trim
Connections
LED
AC Input (CN1)
Top View
Pin #
Terminal
1 AC/L
3 AC/N
3 Pins (Pin2 removed) with
3.96mm pitch
4.0
DC Output (CN2)
Side View
Pin #
Terminal
1,2 V+
3,4 V-
4 Pins with
3.96mm pitch
FC = fixing centers
Crimp Terminal AWG Range: 18-22AWG
Tolerance: xx.x= ±1.0mm
xx.xx= ±0.5mm
2.5
28.0
Customer Application
Compatible Connectors
Housing
3.5
4.0
PCB thickness=1.6mm
Customer Application
Landwin 3960S Series
JST VHR
Molex 51144 Series
FC 44.3
Crimp Terminal
Bottom View
Landwin 3963T011R
JST SVH-21T-P1.1
Molex 50539
3.15
FC 95.3
continued on next page
www.recom-power.com
REV.: 4/2020
PA-5
! NOT RECOMMENDED FOR NEW DESIGNS !
(LAST TIME BUY: 30TH NOV 2020)
RAC35-G/OF
vertical
DC
AC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin and full load unless otherwise stated)
APPLICATION and INSTALLATION
Mounting
horizontal (standard)
AC
AC
horizontal (standard)
DC
DC
AC
If module is mounted vertical or upside-down with natural convection cooling, the power must be derated ≥ 10%.
vertical
vertical
DC
DC
upside-down
AC
DC
AC
AC
Block diagram
L
N
T3.15A
Input
upside-down Filter
PE
DC
DC
OCP
Limit
+V
Output
Filter
upside-down
Power Stage
-V
AC
AC
LED
Protection
OVP
ShutDown
Outoput
Voltage
Regulation
Vadj.
PACKAGING INFORMATION
Parameter
Packaging Dimension (LxWxH)
Type
cardboard box
Packaging Quantity
174.0 x 125.0 x 266.0mm
10pcs
Storage Temperature Range
Storage Humidity
Value
-40°C to +85°C
non-condensing
10% - 95% RH max.
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 4/2020
PA-6
很抱歉,暂时无法提供与“RAC35-24SG/OF”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 1+152.141421+19.68182