!NOT RECOMMENDED FOR NEW DESIGNS!
LAST TIME BUY: 30TH OCT 2020, 0512DB, 0512TB, 0515TB, 05DB, 12DB, 12SB, 24SB
LAST TIME BUY: 30TH OCT 2020, “-ST” VERSION
Features
• Universal input voltage range
• 3kVAC / 1 minute isolation
• Low output ripple and noise
• Short circuit protected
• Triple output with independent outputs
• Suitable for industrial applications
• CE marked
Regulated
Converter
Description
AC/DC Converter
RAC
RAC40-B
40 Watt
3
Single,
Dual, Double,
Triple Output
YEA R
Switching AC/DC power module for PCB or DIN-rail mounting.
y
w
arrant
Selection Guide
Part
Input
Output
Output
Efficiency
Max. Capacitive
Number
Voltage Range
Voltage
Current
typ (1) Load
[VAC] [VDC] [mA] [%]
[µF]
RAC40-15SB 90-264 15 2666 83
6600
RAC40-15DB
90-264
±15
±1333
83
±1000
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
T
TS
C
D
IA N
T PRO
U
RE
CONVER
T
S
PL
M
R
M
REACH
compliant
CO
10 from 10
CO
Part
Input
Output
Output
Efficiency
Max. Capacitive
Number
Voltage Range
Voltage
Current
typ (1) Load
[VAC] [VDC] [mA] [%]
[µF]
RAC40-05SB (2) 90-264 5 8000 81 40000
RAC40-12SB (2) 90-264 12 3333 84
8600
RAC40-24SB (2) 90-264 24 1667 83
1400
RAC40-05DB (2) 90-264 ±5 ±4000 81 ±12000
RAC40-12DB (2) 90-264 ±12 ±1666 83
±4400
RAC40-0512DB (2) 90-264 5/12 5000/1250 82 10000/470
RAC40-0512TB (2) 90-264 5/±12 5000/±600 82 10000/±780
RAC40-0515TB (2) 90-264 5/±15 5000/±500 81 10000/±900
O
E
S
RoHS 2 +
compliant
C
M
TS
C O N V ER
C
M
R
RE
O
E
NRND (Last time buy: 30 Oct 2020)
th
C
PL
U
D
IA N
T PRO
PREFERRED ALTERNATIVES
Please consider this alternatives:
RACM40-K Series
EN60950-1 certified
EN55032 compliant
EN55024 compliant
Model Numbering
RAC40-__ _BConnection (2)
nom. Output Power
Single, Dual or Triple
Output Voltage
Notes:
Note2: no suffix for standard package (THT)
add suffix “ST” for screw terminal module
Ordering Examples:
RAC40-05SB
RAC40-24SB-ST
www.recom-power.com
40 Watt
40 Watt
5Vout
24Vout
Single Output
Single Output
THT
Screw Terminal
REV.: 4/2020
PA-1
! NOT RECOMMENDED FOR NEW DESIGNS !
LAST TIME BUY: 30TH Oct 2020, 0512DB, 0512TB, 0515TB, 05DB, 12DB, 12SB, 24SB
LAST TIME BUY: 30TH OCT 2020, “-ST” VERSION
RAC40-B
AC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
BASIC CHARACTERISTICS
Parameter
Input Voltage Range (3)
Condition
Min.
Typ.
Max.
nom. Vin = 230VAC
90VAC
100VDC
230VAC
264VAC
375VDC
115VAC
230VAC
Input Current
Inrush Current
860mA
460mA
115VAC
230VAC
2ms max., cold start
No load Power Consumption
30A
50A
115VAC/230VAC
Input Frequency Range
720mW
AC Input
47Hz
Hold-up Time
440Hz
10ms
1%
10%
25%
Single
Dual
Double, Triple
Minimum Load
Internal Operating Frequency
Output Ripple and Noise
132kHz
1.0% of Vout
20MHz BW
(4)
Notes:
Note3: The products were submitted for safety files at AC-Input operation
Note4: Measurements are made with a 0.1µF and 47µF MLCC in parallel across output (low ESR)
REGULATIONS
Parameter
Output Accuracy (5)
Value
±2.0% typ.
Double, Triple
Line Regulation
Load Regulation
Condition
Single, Dual
low line to high line
(6)
±0.5% typ.
Double, Triple
±0.5% typ. (+5Vout) / ±5.0% typ. (±Vout)
1% to 100% load
Single
1.0% typ.
10% to 100% load
Dual
1.0% typ.
25% to 100% load
15% to 100% load
Cross Regulation
±3.0% typ. (+5Vout) / ±5.0% typ. (±Vout)
Single, Dual
Double
2.0% typ. (+5Vout) / 6.0% typ. (±Vout)
Triple
3.0% typ. (+5Vout) / 7.0% typ. (±Vout)
Dual
Double
25% to 100% load
±5.0% typ.
±1.0% typ. (+5Vout) / ±7.0% typ. (±Vout)
Triple
±3.0% typ. (+5Vout) / ±7.0% typ. (±Vout)
Notes:
Note5: Triple output version has +/- Vout common that isn’t connected to +5V return pin internally
Note6: Operation below Minimum Load will not harm the converter, but specifications may not be met
PROTECTIONS
Parameter
Type
Value
Short Circuit Protection (SCP)
Hiccup mode, auto recovery
Over Voltage Protection (OVP)
zener diode clamp
Over Current Protection (OCP)
105% typ.
Over Temperature Protection (OTP)
Isolation Voltage
@tc =100°C
I/P to O/P
tested for 1 minute
thermal shutdown, auto restart after cool down
3kVAC
Isolation Resistance
100MΩ max.
Leakage Current
0.75mA max.
continued on next page
www.recom-power.com
REV.: 4/2020
PA-2
! NOT RECOMMENDED FOR NEW DESIGNS !
LAST TIME BUY: 30TH Oct 2020, 0512DB, 0512TB, 0515TB, 05DB, 12DB, 12SB, 24SB
LAST TIME BUY: 30TH OCT 2020, “-ST” VERSION
RAC40-B
AC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Notes:
Note7: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type
Note8: An external MOV is recommended. The varistor should comply with IEC-61051-2. e.g. 14S471K series
Protection Circuit
L
N
F
VACin (L)
+Vout
VACin(N)
-Vout
+Vout
U
-Vout
ENVIRONMENTAL
Parameter
Condition
Operating Temperature Range
@ natural convection 0.1m/s
Value
full load
-40°C to +50°C
refer to derating graph
-40°C to +70°C
Temperature Coefficient
±0.01%/K typ.
Operating Humidity
95% RH max.
MTBF
according to MIL-HDBK-217F, G.B.
200 - 400 x 103 hours
+25°C
Derating Graph
(@ Chamber and natural convection 0.1m/s)
100
90
Output Load [%]
80
70
60
50
40
30
20
10
0
-40 -30 -20 -10
0
10
20
30
40 50
60
70
80
Ambient Temperature [°C]
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report / File Number
Information Technology Equipment, General Requirements for Safety
EAC Safety of Low Voltage Equipment
Standard
EN60950-1:2006 + A2:2013
RU-AT.49.09571
RoHS2+
TP TC 004/2011
RoHS-2011/65/EU + AM-2015/863
EMC Compliance
Condition
Electromagnetic compatibility of multimedia equipment – Emission Requirements
Standard / Criterion
EN55032:2015, Class B
Information technology equipment - Immunity characteristics Limits and methods of measurement
EN55024:2010 + A1:2015
Limits for harmonic current emissions
EN61000-3-2, 2014
Limitation of voltage fluctuations/flicker in low-voltage systems
EN61000-3-3, 2013
www.recom-power.com
REV.: 4/2020
PA-3
! NOT RECOMMENDED FOR NEW DESIGNS !
LAST TIME BUY: 30TH Oct 2020, 0512DB, 0512TB, 0515TB, 05DB, 12DB, 12SB, 24SB
LAST TIME BUY: 30TH OCT 2020, “-ST” VERSION
RAC40-B
AC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter
Material
Type
Value
case
epoxy with fivbreglas (UL94V-0)
Dimension (LxWxH)
standard
with suffix “-ST”
89.0 x 64.1 x 25.0mm
111.9 x 64.6 x 30.6mm
Weight
standard
with suffix “-ST”
242g typ.
317g typ.
Dimension Drawing (mm)
89.0
Pin Connections
Single
Dual
Double
Triple
1
VAC in (L)
VAC in (L)
VAC in (L)
VAC in (L)
64.1
Pin #
2
VAC in (N)
VAC in (N)
VAC in (N)
VAC in (N)
3
+Vout
+Vout
+12Vout
+Vout
4
no Pin
no Pin
+5Vout
+5Vout
5
-Vout
Com
+12V Rth
Vout Com
6
no Pin
no Pin
+5V Rth
+5V Rth
7
NC
-Vout
no Pin
-Vout
25.0
tc = case temperature measuring point
Tolerance:
xx.x= ±0.5mm
xx.xx= ±0.25mm
6.00
Ø1.20±0.10
2.54
2
2.54
81.30
Bottom View
12.70
4
5
4
6
15.24
32.05
12.70
Top View
3
2
7
4.11
55.88
5
tc
3.85
3
6
44.50
1
1
15.24
7
Recommended Footprint Details
continued on next page
www.recom-power.com
REV.: 4/2020
PA-4
! NOT RECOMMENDED FOR NEW DESIGNS !
LAST TIME BUY: 30TH Oct 2020, 0512DB, 0512TB, 0515TB, 05DB, 12DB, 12SB, 24SB
LAST TIME BUY: 30TH OCT 2020, “-ST” VERSION
RAC40-B
AC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Screw Terminal Module “ST” version
4 x Ø4.3
5
2
6
3
7
Fuse
64.6
1
FC 50.0
4
8
7.30
FC 100.0
5.95
30.6
111.9
7
6
5
4
5.5
8
removable DIN RAIL Mounting Bracket
Screw terminal information
#
Single
Dual
Double
Triple
1
NC
NC
NC
NC
2
VAC in (L)
VAC in (L)
VAC in (L)
VAC in (L)
3
VAC in (N)
VAC in (N)
VAC in (N)
VAC in (N)
4
+Vout
+Vout
+12Vout
+Vout
5
NC
NC
+5Vout
+5Vout
6
-Vout
Com
+12V Rth
Com
7
NC
NC
+5V Rth
+5V Rth
8
NC
-Vout
NC
-Vout
7.5mm Pitch
suitable wire: 24-12AWG (0.5-2.5mm²)
wire stripping length: 7mm typ.
recommended tightening torque: 0.5Nm
NC = No Connection
FC = Fixing Centers
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.25mm
PACKAGING INFORMATION
Parameter
Packaging Dimension (LxWxH)
Packaging Quantity
Type
cardboard box
Value
standard
with suffix “-ST”
standard
with suffix “-ST”
Storage Temperature Range
Storage Humidity
260.0 x 70.0 x 42.0mm
119.0 x 64.0 x 54.0mm
2pcs
1pcs
-40°C to +85°C
non-condensing
95% RH
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 4/2020
PA-5