• 7W Class II AC-DC LED power supply
• Suitable for high brightness LED
• 250mA, 350mA, 500mA and 680mA constant
current operation
• 3.75kVAC isolation
• Fused input and SCP, OCP, OVP, OLP
• IP67 rated
Features
Constant
Current
LED Driver
Description
The RACD07 is a constant current 7W AC/DC source for LED lighting with a wide input voltage range.
The LED drivers are available with constant current outputs of 250mA, 350mA, 500mA or 680mA.
The series is IP67 rated and suitable for use in dry, damp or wet areas. RACD07 drivers have a
3 year warranty.
Selection Guide
Part
Number
Input Constant Current (1)
Voltage Range
Mode
[VAC]
[VDC] [mA]
RACD07-250
90-295
RACD07-350
RACD07-500
RACD07-700
Efficiency
min.
[%]
AC/DC Converter
RACD07
7 Watt
Constant
Current Single
Output
Rated Power
max.
[W]
14-28 250
75
7
90-295
10-20 350
70
7.3
90-295
5-14.5 500
70
7.2
90-295
3-10.5 680
70
7.1
All LED Drivers may not be used without a load. They must be switched on the primary side only.
Noncompliance may damage the LED or reduce its lifetime.
Notes:
Note1:
Constant current operation region is within 75%-100% rated output voltage. This is the suitable
operation region for LED related applications, but please reconfirm special electrical requirements
for some specific system design.
Model Numbering
E340696
RACD07-___
nom. Output Power
nom. Output Current
Specifications (measured @ ta= 25°C and 115/230VAC)
BASIC CHARACTERISTICS
Parameter
Condition
Input Voltage Range
Min.
Typ.
90VAC
230VAC
120VDC
Max.
295VAC
415VDC
Input Current
full load, 100VAC
200mA
Inrush Current
230VAC
10A
No Load Power Consumption
230VAC
0.5W
Input Frequency Range
47Hz
Power Factor
0.50
63Hz
Start-up Time
1s
Hold-up Time
Set-up Time
18ms
full load, 230VAC
Internal Operating Frequency
Output Ripple Current (2)
UL8750 certified
UL1310 certified
CSA-C22.2 No. 223-M91 certified
CSA-C22.2 No. 250.13-12 certified
IEC/EN61347 certified
IEC/EN61347-2-13 certified
EN55015 compliant
EN61547 compliant
EAC
0.5s
45kHz
20MHz BW
30mAp-p
Notes:
Note2: Measured with a 12“ twisted pair-wire terminated with 0.1µF & 47µF parallel capacitor
continued on next page
www.recom-power.com
REV.: 4/2019
L-1
RACD07
AC/DC Converter
Series
Specifications (measured @ ta= 25°C and 115/230VAC)
Input Voltage vs. Load
100
90
Output Load [%]
80
70
60
50
40
30
20
10
0
80 90 100
120
140
160
180
200
220
240
295
Input Voltage [VAC]
REGULATIONS
Parameter
Condition
Output Voltage Accuracy
Value
includes: line, load and tolerance
±5%
Output Current Accuracy
±3% typ. / ±7% max.
PROTECTION
Parameter
Condition
Value
Internal Input Fuse
T1A, slow blow
Hiccup Mode, auto recovery after fault condition is removed
Short Circuit Protection (SCP)
Overload Protection (OLP)
105% - 120% typ.
Over Current Protection (OCP)
Constant current mode protection
Isolation Voltage
I/P to O/P
3.75kVAC / 1 minute
Isolation Resistance
500VDC
100MW min.
Notes:
Note3: Refer to local wiring regulations if input over-current protection is also required
Maximum loading of automatic circuit breakers*
* @ 115VAC, 1Ohm, 90° phase angle
and max. load
Circuit Breaker
Circuit Breaker Current
* @ 230VAC, 1Ohm, 90° phase angle
and max. load
Circuit Breaker
Circuit Breaker Current
* @ 277VAC, 1Ohm, 90° phase angle
and max. load
Circuit Breaker
Circuit Breaker Current
Typ
10A
16A
20A
25A
Typ
10A
16A
20A
25A
Typ
10A
16A
20A
25A
C
101
128
171
228
B
61
100
121
150
B
70
115
139
172
C
121
164
221
291
C
139
188
254
334
ENVIRONMENTAL
Parameter
Operating Temperature Range
Condition
-20°C to +50°C
non condensing
20% - 90% RH
Max. Case Temperature
Operating Humidity
+85°C
IP Rating
Vibration
Design Lifetime
MTBF
Value
@ natural convection 0.1m/s, full load
IP67
10-500Hz, 2G; 10 minute/cycle
1 cycle period for 60 min each along X, Y and Z axes
+25°C ambient
70 x 103 hours
according to MIL-HDBK-217F, G.B. +25°C
200 x 10³ hours
continued on next page
www.recom-power.com
REV.: 4/2019
L-2
RACD07
AC/DC Converter
Series
Specifications (measured @ ta= 25°C and 115/230VAC)
Derating Graph
(@ natural air convection 0.1m/s)
100
90
Output Load [%]
80
70
60
50
40
30
20
10
0
-20
-10
0
10
20
30
40
50
60
Ambient Temperature [°C]
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report Number
Standard for LED Equipment for use in Lighting Products
UL8750, 1st Edition, 2009
Standard for Class 2 Power Units
UL1310, 6th Edition, 2011
E340696-1-7
LED Equipment for Lighting Applications
Canadian Standard for Powr Supplies with Extra-Low-Voltage Class 2 Outputs
CSA C22.2 No. 223-M91
Safety of control gear for LED modules
PSE102-0283
Safety requirements for lamp controlgear
RoHS2
RU Д- AT.AB49.B.09571
EAC
EMC Compliance
Condition
Limits and methods of measurement of radio disturbance characteristics of
electrical lighting and similar equipment
TP TC 004/2011
Standard / Criterion
EN61547:2009
Information technology equipment - Radio disturbance characteristics - Limits
and methods of measurement
CISPR22, 3rd Edition, 1997, Class B
Radio Frequency Devices, Subpart B - Unintentional Radiators
47 CFR, FCC Part 15 Subpart B, Class B
Methods of Measurement of Radio-Noise Emissions from Low-Voltage
Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz
ANSI C63.4:2009
Alternating Current High Voltage Power Systems
Radiated, radio-frequency, electromagnetic field immunity test
IEC/EN61347-2-13, 2nd Edition 2014
IEC61347-1, 3rd Edition, 2015
EN61347-1:2015
RoHS-2011/65/EU + AM-2015/863
EN55015:2013 + A1:2015, Class B
Equipment for general lighting purposes – EMC immunity requirements
ESD Electrostatic discharge immunity test
CSA-C22.2 No. 250.13-12
Canadian ICES-003 issue 4, 2004
±8, 4, 2kV Air Discharge,
±4, 2 kV Contact Discharge
3V/m
IEC61000-4-2:2008 Criteria A
IEC61000-4-3:2006 + A2:2010 Criteria A
Fast Transient and Burst Immunity
±0.5, ±1kV AC Input
±0.5kV DC Output
IEC61000-4-4:2012, Criteria A
Surge Immunity
±0.5, ±1kV AC Input
IEC61000-4-5:2014, Criteria A
Immunity to conducted disturbances, induced by radio-frequency fields
AC and DC Port: 3V
IEC61000-4-6:2013, Criteria A
3A/m at 50/60Hz
IEC61000-4-8:2009, Criteria A
Power Frequency Magnetic Field Immunity
Voltage Dips and Interruptions
Dips: >95%
IEC61000-4-11:2004 Criteria B
Dips: 30%
IEC61000-4-11:2004 Criteria B
Limits for harmonic current emissions
IEC61000-3-2, 2014
Limitation of voltage fluctuations/flicker in low-voltage systems
IEC61000-3-3, 2013
www.recom-power.com
REV.: 4/2019
L-3
RACD07
AC/DC Converter
Series
Specifications (measured @ ta= 25°C and 115/230VAC)
DIMENSION and PHYSICAL CHARACTERISTICS
Parameter
Type
Value
Material
case
potting
plastic (UL94V-2)
silicone (UL94V-0)
Dimension (LxWxH)
57.0 x 40.8 x 24.0mm
Weight
75g
Dimensions Drawing (mm)
57.0
Wired Connection
# Function Wire Color
1 VAC in (L)
brown
2 VAC in (N)
blue
3
LED+
red
4
LED-
black
3
4
4.0
15.3
tc
Type
UL-1007, AWG18
UL-1007, AWG18
UL-1007, AWG18
UL-1007, AWG18
tc= case temperature measuring point
FC = fixing centers
Tolerance: x x.x= ±0.5mm
1
2
PRI
39.2
11.0
150±10
SEC
17.0
49.0
FC 4.5
2.0
24.0
22.2
40.8
INSTALLATION and APPLICATION
Connection
L N
LED+
LED-
PACKAGING INFORMATION
Parameter
Packaging Dimension (LxWxH)
Type
cardboard box
25pcs
Packaging Quantity
Storage Temperature Range
Storage Humidity
Value
286.0 x 201.0 x 88.0mm
-40°C to +85°C
non condensing
10% - 90% RH
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 4/2019
L-4