Features
• Low profile case (13mm height max.)
• 350mA to 700mA constant current outputs
• Terminal block input/output with cable clamps
LED
Driver
AC/DC Converter
• Fully protected (OLP, SCP, OCP, OTP)
• Low standby power, ErP conform
RACD12-LP
• Low cost
Description
These low profile constant current LED drivers have been designed for cost-sensitive applications.
The SELV outputs are suitable for both independently supplied or built-in power-supply LED luminaires.
Their low profile design allows them to be invisibly built into furniture, discreetly mounted under shelves
or integrated in space-restricted applications such as coving lighting, strip lighting or troffer lighting systems. The power supplies are short circuit and overload protected and come with a full 3-year warranty.
12 Watt
Constant
Current Single
Output
Selection Guide
Part
Number
Input
Input
Output
Output Efficiency Output
Voltage Range
Current Voltage Range Current
typ. Power max.
[VAC] [mA] [VDC] [mA]
[%]
[W]
RACD12-350-LP
198-264 130 2-37 350
86
13W
RACD12-500-LP
198-264 130 2-24 500
81
12W
RACD12-700-LP
198-264 130 2-19 700
85
13W
All LED Drivers may not be used without a load. They must be switched on the primary side only.
Noncompliance may damage the LED or reduce its lifetime.
ERP
compliant
Specifications (measured @ Ta= 25°C, 240VAC and rated load)
BASIC CHARACTERISTICS
Parameter
Condition
Input Voltage Range
Min.
Typ.
Max.
198VAC
230VAC
264VAC
Inrush Current
8.0A
Start-up Time
500ms
Input Frequency Range
47Hz
63Hz
No Load Power Consumption
Power Factor
0.5W
full load, 230VAC
Internal Operating Frequency
Output Ripple Current
full load
0.55
60kHz
140kHz
IEC/EN61347-1 certified
IEC/EN61347-2-13 certified
ENEC certified
CB report
EN55015 compliant
50mAp-p
(1)
Notes:
Note1: Measured at 20MHz Bandwidth using 0.1µF & 47µF parallel capacitor
REGULATIONS
Parameter
Condition
Value
Output Accuracy
±5% max.
Line Regulation
5% max.
Load Regulation
5% max.
www.recom-power.com
REV.: 2/2019
L-1
RACD12-LP
AC/DC Converter
Series
Specifications (measured @ Ta= 25°C, 240VAC and rated load)
PROTECTION
Parameter
Condition
Input Fuse
Value
external fuse is recommended
T1A
Open Circuit Protection (OCP)
auto recovery after fault condition is removed
Over Load Protection (OLP)
auto recovery after fault condition is removed
Over Voltage Protection (OVP)
auto recovery after fault condition is removed
Over Temperature Protection (OTP)
110°C Tcase
Isolation Voltage
auto recovery after fault condition is removed
I/P to O/P
3.75kVAC / 1 minute
Maximum loading of automatic circuit breakers
* @ 230VAC, 1Ohm, 90° phase angle and max. load
Circuit Breaker
Typ
Circuit Breaker Current
10A
16A
20A
25A
B
17
28
35
44
C
37
59
74
92
ENVIRONMENTAL
Parameter
Condition
Value
Operating Temperature Range
-20°C to +50°C
Maximum Case Temperature
+80°C
Operating Altitude
2000m
Operating Humidity
non-condensing
5% to 85% RH
IP Rating
IP20
Pollution Degree
PD2
Design Lifetime
30 x 10³ hours
Derating Graph
100
90
Output Load [%]
80
70
60
50
40
30
20
10
0
-20
-10
0
10
20
30
40
50
60
Ambient Temperature [°C]
www.recom-power.com
REV.: 2/2019
L-2
RACD12-LP
AC/DC Converter
Series
Specifications (measured @ Ta= 25°C, 240VAC and rated load)
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report Number
Lamp controlgear Part 1: General and safety requirements (CB Scheme)
Standard
IEC61347-1:2015+A1:2017, 3rd Edition
374931
Lamp controlgear Part 2-13: Particular requirements for d.c. or a.c. supplied electronic
controlgear for LED modules (CB Scheme)
Lamp controlgear Part 1: General and safety requirements (LVD)
IEC61347-2-13:2014+A1:2016, 2nd Edition
EN61347-1:2015
Lamp controlgear Part 2-13: Particular requirements for d.c. or a.c. supplied electronic
controlgear for LED modules (LVD)
EN61347-2-13:2014 + A1:2017
Lamp controlgear Part 1: General and safety requirements
EN61347-1:2015
374931
Lamp controlgear Part 2-13: Particular requirements for d.c. or a.c. supplied electronic
controlgear for LED modules
DC or AC supplied electronic control gear for LED modules Performance requirements
374931
DC or AC supplied electronic control gear for LED modules Performance requirements
EAC
RU-AT.49.09571
RoHS 2
EN61347-2-13:2014+A1:2017
IEC62384:2006 1st Edition + A1:2009
EN62384:2006 + A1:2009
TP TC 004/2011
RoHS 2011/65/EU + AM2015/863
EMC Compliance
Condition
Limits and methods of measurement of radio disturbance characteristics of electrical
lighting and similar equipment
EN55015:2013 + A1:2015
374931
Equipment for general lighting purposes – EMC immunity requirements
Assessment of lighting equipment related to human exposure to electromagnetic fields
Radiated, radio-frequency, electromagnetic field immunity test
3V/m
±0.5kV (DC Output)
±1kV (AC Input)
Fast Transient and Burst Immunity
Surge Immunity
±0.5kV (AC Input)
Immunity to conducted disturbances, induced by radio-frequency fields
AC Power Port 3V
Voltage Dips and Interruptions
Voltage Dips and Interruptions
EN61547:2009
EN62493:2015
±8kV Air Discharge,
±4kV Contact Discharge
ESD Electrostatic discharge immunity test
Standard / Criterion
EN61000-4-2:2009, Criteria A
EN61000-4-3:2006 + A2:2010, Criteria A
EN61000-4-4:2012, Criteria A
EN61000-4-5:2014 + A1:2017, Criteria A
EN61000-4-6:2014, Criteria A
Voltage Dips >95%
EN61000-4-11:2004 + A1:2017, Criteria B
Voltage Dips 30%
EN61000-4-11:2004 + A1:2017, Criteria B
Limits of Harmonic Current Emissions
EN61000-3-2:2014, Class C
Limits of Voltage Fluctuations & Flicker
EN61000-3-3:2013, Clause 5
DIMENSION and PHYSICAL CHARACTERISTICS
Parameter
Type
Value
Material
case
plastic (UL94V-2)
Dimension (LxWxH)
128.0 x 50.0 x 13.0mm
Weight
70g
continued on next page
www.recom-power.com
REV.: 2/2019
L-3
RACD12-LP
AC/DC Converter
Series
Specifications (measured @ Ta= 25°C, 240VAC and rated load)
52.0
PRI
SEC
3
2
4
50.0
tc
1
FC 44.0
18.0
Dimension Drawing (mm)
M3 Screws
wire preparation
6-7mm
FC 115.0
50.0
13.0
2.0
128.0
Connection via Screw Terminal
# Function Solid Wire
Stranded Wire (2) AWG
1 VAC in (N) 0.75-1.5mm²
0.75-1.5mm²
20-16
2 VAC in (L) 0.75-1.5mm²
0.75-1.5mm²
20-16
3 LED+ 0.5-1.5mm²
0.5-1.5mm² 21-16
4 LED- 0.5-1.5mm²
0.5-1.5mm²
21-16
Notes:
Note2: The use of sleeve or ferrule terminations is recommended
wire stripping length: 6-7mm
recommended tightening torque: 0.25Nm
tc= case temperature measuring point
FC = fixing centers
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.35mm
2 mounting screws are included
INSTALLATION and APPLICATION
Connection
L N
LED+
LED-
PACKAGING INFORMATION
Parameter
Packaging Dimension (LxWxH)
Packaging Quantity
Type
cardboard box
Storage Temperature Range
Storage Humidity
Value
265.0 x 139.0 x 62.0mm
10pcs
-20°C to +70°C
non-condensing
5% - 85% RH
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 2/2019
L-4
很抱歉,暂时无法提供与“RACD12-700-LP”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 1+135.148231+17.46549
- 5+123.486795+15.95846
- 10+118.7811510+15.35034
- 25+112.8340725+14.58179
- 50+108.5286250+14.02538
- 100+104.38509100+13.48991
- 250+99.14296250+12.81246
- 500+95.34991500+12.32227
- 国内价格 香港价格
- 1+119.267591+15.41320
- 30+106.5014130+13.76340
- 60+105.0149360+13.57130
- 120+101.95455120+13.17580