RACM100-48S

RACM100-48S

  • 厂商:

    RECOM

  • 封装:

    -

  • 描述:

    AC/DCCONVERTER48V100W

  • 数据手册
  • 价格&库存
RACM100-48S 数据手册
!NOT RECOMMENDED FOR NEW DESIGNS! Features • Long 5 year warranty • 2MOPP/250VAC AC/DC Converter • Suitable for built in Class II applications • Wide input voltage range (85-264VAC) Regulated Converter • Low leakage current (8.0mm >8.0mm Notes: Note5: For repeat Hi-Pot testing, reduce the time and/or the test voltage ENVIRONMENTAL Parameter Condition Value refer to ”Derating Graph” Operating Temperature Range full load, 230VAC enclosed open frame Temperature Coefficient 5000m max. non-condensing Pollution Degree 5% to 95% RH PD2 High Temperature Operating Life (HTLO) JEDEC JESD22-A108 Shock IEC60068-2-27 Vibration MTBF -25°C to +60°C -25°C to +55°C ±0.02%/K Operating Altitude Operating Humidity -25°C to +85°C IEC60068-2-6 according to MIL-HDBK-217F, full load, +25°C 790.3 x 103 hours continued on next page www.recom-power.com REV.: 12/2022 MED-3 ! NOT RECOMMENDED FOR NEW DESIGNS ! RACM100 AC/DC Converter Series Specifications (measured @ Ta= 25°C, 250VAC, full load and after warm-up) Derating Graph (@ Chamber and natural convection 0.1m/s) /OF version 100 90 90 80 80 70 70 Output Load [%] Output Load [%] Enclosed 100 60 50 40 30 50 40 30 20 10 60 20 115VAC 230VAC 0 -25 -20 -10 0 115VAC 230VAC 10 0 -25 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 55 85 Ambient Temperature [°C] 10 20 30 40 50 60 70 80 90 100 110 85 55 Ambient Temperature [°C] SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Medical Electric Equipment, General Requirements for Safety and Essential Performance E314885 Medical Electric Equipment, General Requirements for Safety and Essential Performance (CB) 181200102 Medical Electric Equipment, General Requirements for Safety and Essential Performance Information Technology Equipment - General Requirements for Safety (LVD) TW1708008-001 Information Technology Equipment - General Requirements for Safety EAC RU-AT.49.09571 RoHS2 Standard CAN/CSA-C22.2 No. 60601-1:14 ANSI/AAMI ES60601-1:2005 + A2:2010 IEC60601-1:2005 + A1:2012, 3rd Edition EN60601-1:2006 +12:2014 EN60950-1:2006 + A2:2013 IEC60950-1:2005, 2nd Edition + A2:2013 TP TC 004/2011 TP TC 004/2011 RoHS-2011/65/EU + AM-2015/863 EMC Compliance (Medical) Conditions Standard / Criterion Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic compatibility - Requirements and tests EN60601-1-2:2015 Industrial, scientific and medical equipment – Radio frequency disturbance characteristics – Limits and methods of measurement EN55011:2009 + A1:2010 Class B Conducted, Class A Radiated Industrial, scientific and medical equipment - Radio frequency disturbance characteritics Limits and methods of measurement CISPR11:2009 + A1:2010 Class B Conducted, Class A Radiated ESD Electrostatic discharge immunity test Radiated, radio-frequency, electromagnetic field immunity test Air ±15kV; Contact ±8kV IEC61000-4-2:2008 10V/m (80-2700MHz) 27V/m (385MHz) 28V/m (450MHz) IEC61000-4-3:2006 + A2:2010 Fast Transient and Burst Immunity AC Power Port: ±2kV IEC61000-4-4:2012 Surge Immunity AC Port: IEC61000-4-5:2005 Immunity to conducted disturbances, induced by radio-frequency fields Power Frequency Magnetic Field Voltage Dips and Interruptions Limits of Harmonic Current Emissions L-N= ±1kV L-GND= ±2kV 6Vr.m.s IEC61000-4-6:2013 50Hz, 30A/m IEC61000-4-8:2009 Dips: >95%; 30%; Interruptions >95% IEC61000-4-11:2004 EN61000-3-2:2005 + A2:2009, Class D Limits of Voltage Fluctuations and Flicker EN61000-3-3:2013 continued on next page www.recom-power.com REV.: 12/2022 MED-4 ! NOT RECOMMENDED FOR NEW DESIGNS ! RACM100 AC/DC Converter Series Specifications (measured @ Ta= 25°C, 250VAC, full load and after warm-up) EMC Compliance (Industrial) Conditions Standard / Criterion 47CFR FCC Part 15 Subpart B, Class B Limitations on the amount of electromagnetic intererence allowed from digital & electronic devices Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and Electronic Equipment in the Range of 9 kHz to 40 GHz ANSI C63.4:2014 Electromagnetic compatibility of multimedia equipment – Emission Requirements EN55032:2015+AC:2013, Class B Information technology equipment - Immunity characteristics - Limits and methods of measurement EN55024:2010+A1:2015 ESD Electrostatic discharge immunity test Air ±8kV; Contact ±6kV IEC61000-4-2:2008, Criteria A Radiated, radio-frequency, electromagnetic field immunity test 3V/m (80-1000MHz) 20V/m (80-1000MHz) 3V/m (1-2.5GHz) 10V/m (1-2.5GHz IEC61000-4-3:2006 + A2:2010, Criteria A Fast Transient and Burst Immunity DC Port: ±2kV IEC61000-4-4:2012, Criteria A Surge Immunity DC Port: ±1kV IEC61000-4-5:2014, Criteria A DC Power Port 3V + 20V IEC61000-4-6:2013, Criteria A 50Hz/60Hz 1A/m 50Hz/60Hz 10A/m IEC61000-4-8:2009, Criteria A Dips: >95%; 60%; 30% Interruptions >95% IEC61000-4-11:2004, Criteria A IEC61000-4-11:2004, Criteria B Immunity to conducted disturbances, induced by radio-frequency fields Power Frequency Magnetic Field Voltage Dips and Interruptions Limits of Harmonic Current Emissions EN61000-3-2:2014, Class D Limits of Voltage Fluctuations and Flicker EN61000-3-3:2013 DIMENSION and PHYSICAL CHARACTERISTICS Parameter Material Type enclosed Value aluminum Dimension (LxWxH) enclsoded open frame 91.4 x 62.0 x 39.2mm 76.2 x 50.8 x 32.0mm Weight enclosed open frame 210g 150g continued on next page www.recom-power.com REV.: 12/2022 MED-5 ! NOT RECOMMENDED FOR NEW DESIGNS ! RACM100 AC/DC Converter Series Specifications (measured @ Ta= 25°C, 250VAC, full load and after warm-up) Dimension Drawing Enclosed (mm) 24.5 Trim Adj. 62.0 FC 41.3 CON2 CON1 Top View 22.1 76.2 Connection via Connector AC Input (CON1) FC 84.2 91.4 Side View Pin # Pin Header 1 AC/L 3 AC/N SVH-21T-P1.1 1.20 39.2 DC Output Connector (CON2) Pin # Pin Header 1,2 -Vout 3,4 +Vout SVH-21T-P1.1 FC = fixing centers Crimp Terminal AWG Range: 18-22AWG Tolerance: ±0.5mm 3.5 10.4 10.0 14.0 Bottom View Ø4.0 34.0 36.5 continued on next page www.recom-power.com REV.: 12/2022 MED-6 ! NOT RECOMMENDED FOR NEW DESIGNS ! RACM100 AC/DC Converter Series Specifications (measured @ Ta= 25°C, 250VAC, full load and after warm-up) Dimension Drawing Open Frame (mm) Top View Connection via Connector AC Input (CON1) CON1 Trim Adj. 18.5 CON2 FC 44.4 50.8 76.2 Ø3.2 FC 69.8 29.5 Pin # Pin Header 1 AC/L 3 AC/N SVH-21T-P1.1 DC Output Connector (CON2) Pin # Pin Header 1,2 -Vout 3,4 +Vout SVH-21T-P1.1 FC = fixing centers Crimp Terminal AWG Range: 18-22AWG Tolerance: ±0.5mm 2.5 1.6 29.5 Side View PACKAGING INFORMATION Parameter Packaging Dimension (LxWxH) Packaging Quantity Type cardboard box Value enclosed case 418.0 x 258.0 x 105.0mm open frame 494.0 x 250.0 x 95.0mm enclosed case open frame Storage Temperature Range Storage Humidity 10pcs 25pcs -40°C to +85°C non-condensing 5% to 95% RH The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV.: 12/2022 MED-7
RACM100-48S 价格&库存

很抱歉,暂时无法提供与“RACM100-48S”相匹配的价格&库存,您可以联系我们找货

免费人工找货
RACM100-48S
    •  国内价格
    • 1+1471.16192

    库存:1