!NOT RECOMMENDED FOR NEW DESIGNS!
Features
LAST TIME BUY: 1ST AUG 2022
•
•
•
•
•
•
•
Regulated
Converter
Long 5 year warranty
2MOPP/250VAC
Suitable for built in Class II applications
Wide input voltage range (85-264VAC)
Low leakage current (8.0mm
>8.0mm
Notes:
Note5: For repeat Hi-Pot testing, reduce the time and/or the test voltage
www.recom-power.com
REV.: 12/2021
MED-3
! NOT RECOMMENDED FOR NEW DESIGNS !
LAST TIME BUY: 1ST AUG 2022
RACM150
AC/DC Converter
Series
Specifications (measured @ Ta= 25°C, 230VAC, full load and after warm-up)
ENVIRONMENTAL
Parameter
Condition
Value
without fan
with fan
refer to derating graph
-25°C to +80°C
-25°C to +80°C
Temperature Coefficient
±0.02%/K
Operating Altitude
5000m max.
Operating Humidity
non-condensing
5% to 95% RH
Pollution Degree
PD2
MTBF
786.1 x 10 hours
according to MIL-HDBK-217F, full load, +25°C
3
Derating Graph
(@ Chamber and natural convection 0.1m/s)
115Vin
160
150
140
120
Output Power [W]
Output Power [W]
120
100
80
60
40
20
230Vin
160
150
140
80
60
40
RACM150-xxS/F
RACM150-xxS (xx=15, 24)
RACM150-xxS (xx=12,48)
0
-25 -20 -10 0
100
20
10 20 30 40 50 60 70 80 90 100 110
RACM150-xxS/F
RACM150-xxS (xx=15, 24)
RACM150-xxS (xx=12,48)
0
-25 -20 -10 0
10 20 30 40 50 60 70 80 90 100 110
Ambient Temperature [°C]
Ambient Temperature [°C]
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report / File Number
Medical Electric Equipment, General Requirements for Safety and Essential Performance
Medical Electric Equipment, General Requirements for Safety and Essential Performance (CB)
Medical Electric Equipment, General Requirements for Safety and Essential Performance
Information Technology Equipment - General Requirements for Safety (LVD)
E314885
181200102
TW1708008-001
Information Technology Equipment - General Requirements for Safety
EAC
RU-AT.49.09571
RoHS2
Standard
CAN/CSA-C22.2 No. 60601-1:14
ANSI/AAMI ES60601-1:2005 + A2:2010
IEC60601-1:2005 + A1:2012, 3rd Edition
EN60601-1:2006 +12:2014
EN60950-1:2006 + A2:2013
IEC60950-1:2005, 2nd Edition + A2:2013
TP TC 004/2011 TP TC 004/2011
RoHS-2011/65/EU + AM-2015/863
EMC Compliance (Medical)
Conditions
Standard / Criterion
Medical electrical equipment - Part 1-2: General requirements for basic safety and essential
performance - Collateral standard: Electromagnetic compatibility - Requirements and tests
EN60601-1-2:2015
Industrial, scientific and medical equipment – Radio frequency disturbance characteristics Limits and methods of measurement
EN55011:2009 + A1:2010
Class B Conducted, Class A Radiated
Industrial, scientific and medical equipment - Radio frequency disturbance characteristics Limits and methods of measurement
CISPR11:2009 + A1:2010
Class B Conducted, Class A Radiated
continued on next page
www.recom-power.com
REV.: 12/2021
MED-4
! NOT RECOMMENDED FOR NEW DESIGNS !
LAST TIME BUY: 1ST AUG 2022
RACM150
AC/DC Converter
Series
Specifications (measured @ Ta= 25°C, 230VAC, full load and after warm-up)
EMC Compliance (Medical)
Conditions
ESD Electrostatic discharge immunity test
Radiated, radio-frequency, electromagnetic field immunity test
Air ±15kV; Contact ±8kV
IEC61000-4-2:2008
10V/m (80-2700MHz)
27V/m (385MHz)
28V/m (450MHz)
IEC61000-4-3:2006 + A2:2010
AC Power Port: ±2kV
IEC61000-4-4:2012
Fast Transient and Burst Immunity
Surge Immunity
Standard / Criterion
AC Port:
Immunity to conducted disturbances, induced by radio-frequency fields
Power Frequency Magnetic Field
Voltage Dips and Interruptions
L-N= ±1kV
L-GND= ±2kV
IEC61000-4-5:2005
6Vr.m.s
IEC61000-4-6:2013
50Hz, 30A/m
IEC61000-4-8:2009
Dips: >95%; 30%;
Interruptions >95%
IEC61000-4-11:2004
Limits of Harmonic Current Emissions
EN61000-3-2:2005 + A2:2009, Class D
Limits of Voltage Fluctuations and Flicker
EN61000-3-3:2013
Limitations on the amount of electromagnetic interference allowed from digital & electronic
devices
Methods of Measurement of Radio-Noise Emissions from Low-Voltage Electrical and
Electronic Equipment in the Range of 9kHz to 40GHz
47CFR FCC Part 15 Subpart B, Class B
ANSI C63.4:2014
EMC Compliance (Industrial)
Conditions
Electromagnetic compatibility of multimedia equipment – Emission Requirements
Standard / Criterion
EN55032:2015+AC:2013, Class B
Information technology equipment - Immunity characteristics - Limits and methods of
measurement
EN55024:2010+A1:2015
ESD Electrostatic discharge immunity test
Air ±8kV; Contact ±6kV
IEC61000-4-2:2008, Criteria A
Radiated, radio-frequency, electromagnetic field immunity test
3V/m (80-1000MHz)
20V/m (80-1000MHz)
3V/m (1-2.5GHz)
10V/m (1-2.5GHz)
IEC61000-4-3:2006 + A2:2010, Criteria A
Fast Transient and Burst Immunity
DC Port: ±2kV
IEC61000-4-4:2012, Criteria A
Surge Immunity
DC Port: ±1kV
IEC61000-4-5:2014, Criteria A
DC Power Port 3V + 20V
IEC61000-4-6:2013, Criteria A
50Hz/60Hz 1A/m
50Hz/60Hz 10A/m
IEC61000-4-8:2009, Criteria A
Dips: >95%; 60%; 30%
Interruptions >95%
IEC61000-4-11:2004, Criteria A
IEC61000-4-11:2004, Criteria B
Immunity to conducted disturbances, induced by radio-frequency fields
Power Frequency Magnetic Field
Voltage Dips and Interruptions
Limits of Harmonic Current Emissions
EN61000-3-2:2014, Class D
Limits of Voltage Fluctuations and Flicker
EN61000-3-3:2013
DIMENSION and PHYSICAL CHARACTERISTICS
Parameter
Material
Type
enclosed
Value
aluminum
Dimension (LxWxH)
with Fan
without Fan
116.8 x 62.0 x 49.2mm
116.8 x 62.0 x 39.2mm
Weight
with Fan
without Fan
270g
255g
continued on next page
www.recom-power.com
REV.: 12/2021
MED-5
! NOT RECOMMENDED FOR NEW DESIGNS !
LAST TIME BUY: 1ST AUG 2022
RACM150
AC/DC Converter
Series
Specifications (measured @ Ta= 25°C, 230VAC, full load and after warm-up)
Dimension Drawing without FAN (mm)
116.8
33.0
Top View
62.0
CON2
FC 41.3
CON1
CON3
AC Input Connector CON1
Pin1 Line
Pin3 Neutral
23.1
Mates with
JST housing: VHR-3N
JST crimp terminals: SVH-21T-P1.1
101.6
DC Output Connector CON2
FC 109.6
Pin1,2,3 -Vout
Pin4,5,6 +Vout
Mates with
JST housing: VHR-6N
JST crimp terminals: SVH-21T-P1.1
39.2
Side View
33.0
Pin1 -Fan
33.0
Pin2 +Fan
FC 41.3
CON2
CON1
Tolerance: ±
0.5mm
FC: fixing center
Recommended tightening torque for
mounting holes= 0.49Nm
44.5
23.1
34.0
48.5
62.0
14.0
62.0
FC 41.3
CON2
Bottom View
Mates with
Molex housing: 22-01-1022
CON3
Molex crimp terminals: 2759
95.2
CON3
FAN Output Connector
CON3
CON2
CON3
116.8
1.2
116.8
Ø 4.3
101.6
101.6
FC 109.6
FC 109.6
www.recom-power.com
1.2
CON3
REV.: 12/2021
95.2
4.0
4.0
95.2
CON2
1.2
CON1
39.2
DC/FAN Output Side
39.2
AC Input Side
MED-6
! NOT RECOMMENDED FOR NEW DESIGNS !
AC/DC Converter
LAST TIME BUY: 1ST AUG 2022
RACM150
Series
116.8
Specifications (measured @ Ta= 25°C, 230VAC, full load and after warm-up)
CON3
Dimension Drawing with FAN (mm)
1
CON2
101.5
AC Input Side
62.0
6
2
1
FC 41.3
CON3
CON1
1
3
CON2
Top View
62.0
6
CON1
1
3
2
1
FC 41.3
116.8
1
FC 109.6
CON1
10.0mm minimum
40.0
DC/FAN Output Side
11.5
101.5
10.0mm minimum
11.5
CON3
39.2
40.0
44.5
14.0
34.0
48.5
95.2
CON3
Pin1 Line
CON2
Pin3 Neutral
Mates with
JST housing: VHR-3N
JST crimp terminals: SVH-21T-P1.1
DC Output Connector CON2
Ø 4.3
44.5
34.0
48.5
Pin1,2,3 -Vout
Pin4,5,6 +Vout
Mates with
JST housing: VHR-6N
JST crimp terminals: SVH-21T-P1.1
FAN Output Connector CON3
Ø 4.3
FAN
Rated Voltage:
12V (7-13.8)
Input Power:
0.96W typ. 1.8W max.
Speed: 6000RPM
Air Flow:
7CFM/Min.; 30dBA max.
exp. Lifetime (40°C): >70khours continuous
Cable length:
55mm including connector
www.recom-power.com
AC Input Connector CON1
1.2
14.0
39.2
95.2
50.7
1.2
CON2
Side View
Bottom View
50.7
FC 109.6
REV.: 12/2021
Pin1 -Fan
Pin2 +Fan
Mates with
Molex housing: 22-01-1022
Molex crimp terminals: 2759
Tolerance: ±
0.5mm
FC: fixing center
Recommended tightening torque for
mounting holes= 0.49Nm
MED-7
! NOT RECOMMENDED FOR NEW DESIGNS !
LAST TIME BUY: 1ST AUG 2022
RACM150
AC/DC Converter
Series
Specifications (measured @ Ta= 25°C, 230VAC, full load and after warm-up)
PACKAGING INFORMATION
Parameter
Packaging Dimension (LxWxH)
Type
cardboard Box
Packaging Quantity
418.0 x 308.0 x 105.0mm
10pcs
Storage Temperature Range
Storage Humidity
Value
-40°C to +80°C
non-condensing
5% to 95% RH
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 12/2021
MED-8