RACM40-05SK-T

RACM40-05SK-T

  • 厂商:

    RECOM

  • 封装:

    DIP6 模块

  • 描述:

    封闭式 AC DC 转换器 1 输出 5V 6A 80 ~ 264 VAC,120 ~ 370 VDC 输入

  • 数据手册
  • 价格&库存
RACM40-05SK-T 数据手册
RACM40-18SK-T RACM40-36SK-T Output Current [mA] 2222 1111 Efficiency typ. (1) [%] 90 90 Max. Output Power [W] 40 40 RE T compliant U TS M P ERP compliant LOT6 C RE Output Voltage [VDC] 18 36 D IA N T PRO CO NVE R S Input Voltage Range [VAC] 80-264 80-264 PL M R Selection Guide (on request MOQ ≥1008pcs) Part Number 10 from 10 O REACH U LIA D N T PRO H E224736 OU S E HO CERTIFIED EN-60335-1 pp a Notes: Note1: Efficiency is tested at +25°C with constant resistant mode at full load and 230VAC M C E Max. Output Power [W] 30 40 40 40 40 T RoHS 2 + compliant LD Efficiency typ. (1) [%] 87 90 90 90 90 C O N V ER CO Output Current [mA] 6000 3334 2667 1667 833 M S RACM40-05SK-T RACM40-12SK-T RACM40-15SK-T RACM40-24SK-T RACM40-48SK-T Output Voltage [VDC] 5 12 15 24 48 O R Input Voltage Range [VAC] 80-264 80-264 80-264 80-264 80-264 C CO Part Number 40 Watt 3 1.8” x 3.2” Single Output E Selection Guide RACM40-K es Description The ultra-compact encapsulated industrial + household + medical grade AC/DC converter series RACM40-K delivers 40 watts of output power from -40°C to +65°C with natural air convection only, and up to +85°C with derating or forced air cooling. With a clear focus on extended thermal performance for systems where space is limited, these 1.8“ x 3.2“ compact modules are designed to gain highest overall efficiency levels over the full output load range from universal AC inputs. The RACM40-K has ANSI/AAMI/ IEC 60601-1 medical safety and EN 60601-1-2 medical EMC certifications, 2MOPP, to meet B and BF requirements, 4kVac/1min isolation and offers OVCIII certified to IEC61558. It is additionally certified (CB Report) to IEC/EN 62368-1; IEC61010 and IEC61558-1/-2-16 for industrial applications and IEC/EN 60335-1 for household appliances. The robust built-in class B EMC filter has sufficient margin to allow either Class II or Class I PELV with grounded output installations. The mechanically rugged construction with fully potted encapsulation, 1,6mm pins and additional threaded inserts gives the series enhanced stability against shock and vibrations. AC/DC Converter TS Regulated Converter 1.8“x3.2“x1.2”, encapsulated module 40W power from -40°C up to +65°C ambient Operating temp. up to +85°C with derating OVC III, 4 kVac/1min reinforced isolation 2MOPP medical certified, B and BF compliant 5000m (medical/ITE) operating altitude Class B EMC filter built-in C • • • • • • • Features lianc IEC/EN62368-1 certified ANSI/AAMI ES60601-1 certified CSA/CAN-C22.2 No. 60601-1:14 certified IEC/EN60601-1 certified EN60335-1 certified IEC/EN61010-1 pending EN62233 certified IEC/EN61558-1 certified IEC/EN61558-2-16 certified EN55032/35 compliant IEC/EN60601-1-2 compliant CB Report Model Numbering RACM40- __ SK-T nom. Output Power Output Voltage www.recom-power.com Tray Packaging Single REV.: 1/2021 PA-1 RACM40-K AC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) BASIC CHARACTERISTICS Parameter Condition Min. 60Hz 50Hz 100VAC 47-63Hz DC 80VAC 120VDC Nominal Input Voltage Operating Range (2) Typ. Max. 240VAC 264VAC 370VDC 115VAC 230VAC Input Current Inrush Current 115VAC 230VAC cold start No load Power Consumption 1000mA 500mA 15A 30A 230VAC ErP Standby Mode Conformity (Maximum output power available for stated maximum input power) 115VAC 230VAC 100mW RACM40 input power max. 0.5W 0.3W RACM40 input power max. 1.0W 0.7W RACM40 input power max. 0.5W 0.27W RACM40 input power max. 1.0W 0.65W Input Frequency Range 47Hz Minimum Load 63Hz 0% 115VAC 230VAC Power Factor 0.6 0.5 Start-up Time 160ms Rise Time 70ms 115VAC 230VAC Hold-up Time Internal Operating Frequency Output Ripple and Noise 16ms 60ms 100% load at nominal Vin 5Vout others 20MHz BW (3) 100kHz 80mVp-p 1% of Vout Notes: Note2: The products were submitted for safety files at AC-Input operation Note3: Measurements are made with a 0.1µF MLCC & 10µF E-cap in parallel across output. (low ESR) Efficiency vs. Load others 100 100 90 90 80 80 70 70 Efficiency [%] Efficiency [%] RACM40-05SK 60 50 40 50 40 30 30 115VAC 230VAC 20 10 0 60 10 0 0 10 20 30 40 50 60 70 80 90 100 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] Output Load [%] www.recom-power.com 115VAC 230VAC 20 REV.: 1/2021 PA-2 RACM40-K AC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) REGULATIONS Parameter Condition Value Output Accuracy ±1.0% typ. / ±2.0% max. Line Regulation low line to high line Load Regulation (4) 10% to 100% load Transient Response 5Vout others ±0.1% typ. ±0.05% typ. 5, 12, 15Vout 0.7% typ. 24, 48Vout 0.5% typ. 25% load step change 3.0% max. recovery time 500µs max. Notes: Note4: Operation below 10% load will not harm the converter, but specifications may not be met Deviation vs. Load RACM40-05SK 0.75 0.75 0.50 0.50 0.25 0 -0.25 0.25 0 -0.25 -0.50 -0.50 -0.75 -0.75 -1.0 RACM40-12SK 1.0 Deviation [%] Deviation [%] 1.0 0 10 20 30 40 50 60 70 80 90 -1.0 100 0 10 20 30 Output Load [%] 0.75 0.50 0.50 Deviation [%] Deviation [%] 60 70 80 90 100 70 80 90 100 RACM40-24SK, 48SK 1.0 0.75 0.25 0 -0.25 0.25 0 -0.25 -0.50 -0.50 -0.75 -0.75 -1.0 50 Output Load [%] RACM40-15SK 1.0 40 0 10 20 30 40 50 60 70 80 90 -1.0 100 0 Output Load [%] 10 20 30 40 50 60 Output Load [%] PROTECTIONS Parameter Type Internal Input Fuse Short Circuit Protection (SCP) below 100mW Over Voltage Protection (OVP) Output reverse Voltage Protection Value T3.15A, slow blow type hiccup, auto recovery 105% - 120% of nom. Vout, hiccup mode overrun rate of nominal output 107% - 145% of nom. Vout, hiccup mode continued on next page www.recom-power.com REV.: 1/2021 PA-3 RACM40-K AC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) Parameter Type/Condition Value Over Current Protection (OCP) 130% - 180% of nom. Iout, hiccup mode measured on TC point refer to “Dimension Drawing (mm)” Thermal Shutdown Over Voltage Category (OVC) +130°C typ. OVCII OVCIII up to 2000m according to IEC61558-1 Class of Equipment Class II Isolation Voltage (safety certified) Isolation Resistance (5) Isolation Capacitance Leakage Current Insulation Grade I/P to O/P I/P to O/P 1 minute I/P to O/P, Viso= 500VDC 4kVAC 1GΩ min. I/P to O/P I/P to O/P, 100KHz/0.1V 100pF max. 1.5mA max. reinforced Notes: Note5: For repeat Hi-Pot testing, reduce the time and/or the test voltage ENVIRONMENTAL Parameter Condition Value @ natural convection 0.1m/s (refer to “Derating Graph”) Operating Temperature Range without derating with derating -40°C to +60/65°C -40°C to +85°C Max. Case Temperature 100°C Temperature Coefficient ±0.02%/K Thermal Impedance 6.3K/W Operating Altitude (6) according to 62368-1/61010 and 60601-1 Operating Humidity non-condensing 5000m 20% - 95% RH max. Pollution Degree PD2 Vibration according to MIL-STD-202G MTBF according to MIL-HDBK-217F, G.B. Design Lifetime 10-500Hz, 2G 10min./1cycle, period 60min. along x,y,z axes >1006 x 103 hours >790 x 103 hours +25°C +40°C 230VAC/60Hz and full load +40°C >98 x 103 hours Notes: Note6: Recognized by safety agency for safe operation up to 5000m (OVCII) / 2000m (OVCIII). High altitude operation may impact the performance and lifetime. Please contact RECOM tech support for advice Derating Graph (@ Chamber and natural convection 0.1m/s) others 40 35 35 30 30 Output Power [W] Output Power [W] RACM40-05SK 40 25 20 15 10 25 20 15 10 115-240VAC nom. 100VAC nom. 5 0 -40 -30 -20 -10 0 5 10 20 30 40 50 60 70 80 90 65 85 115-240VAC nom. 100VAC nom. 0 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 65 85 Ambient Temperature [°C] Ambient Temperature [°C] Notes: Note7: Output power derating for Line-input of less than 90VAC (de-rate linearly from 100% at 90VAC to 80% at 80VAC) www.recom-power.com REV.: 1/2021 PA-4 RACM40-K AC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Medical electrical equipment Part 1: General requirements for basic safety and essential performance E511305-D1001-1/A0/C0-UL Medical electrical equipment Part 1: General requirements for basic safety and essential performance Audio/Video, information and communication technology equipment - Safety requirements (CB Scheme) Standard ANSI/AAMI ES60601-1:2005 + A2:2010/2012 CAN/CSA-C22.2 No. 60601-1:14, 3rd Edition IEC60601-1:2005, 3rd Edition + AM1:2012 EN60601-1:2006 + A1:2013 IEC62368-1:2014 2nd Edition 60377568 001 Audio/Video, information and communication technology equipment - Safety requirements (LVD) EN62368-1:2014 + A11:2017 Household and similar electrical appliances – Safety – Part 1: General requirements (LVD) LCS200616140AS001 Electrical Equipment For Measurement, Control, and Laboratory Use; Part 1: General Requirements (CB Scheme) EN60335-1:2012 + A14:2019 IEC61010-1:2010+A1:2016, 3rd Edition pending Electrical Equipment For Measurement, Control, and Laboratory Use; Part 1: General Requirements EN61010-1:2010+A1:2019 Measurement methods for electromagnetic fields of household appliances and similar apparatus with regard to human exposure LCS200616140AS001 Safety of power transformers, power supplies, reactors & similar products for supply voltages up to 1100V (CB Scheme) EN62233:2008 IEC61558-1:2005 2nd Edition + A1:2009 60377570 001 Safety of power transformers, power supplies, reactors & similar products for supply voltages up to 1100 V Part 2: Particular requirements (CB Scheme) IEC61558-2-16:2009 1st Edition + A1:2013 Safety of power transformers, power supplies, reactors & similar products for supply voltages up to 1100V EN61558-1:2005 + A1:2009 60377571 001 Safety of power transformers, power supplies, reactors & similar products for supply voltages up to 1100 V Part 2: Particular requirements EN61558-2-16:2009 + A1:2013 RoHS2 RoHS 2011/65/EU + AM2015/863 EMC Compliance (Medical) Condition Standard / Criterion Medical electrical equipment - Part 1-2: General requirements for basic safety and essential performance - Collateral standard: Electromagnetic compatibility - Requirements and tests 4th Ed. 4789293779 EN60601-1-2:2015 Air ±2, 4, 8, 15kV; Contact ±8kV ESD Electrostatic discharge immunity test Radiated, radio-frequency, electromagnetic field immunity test Fast Transient and Burst Immunity IEC61000-4-2:2008 , Criteria A EN61000-4-2:2009, Criteria A 9V/m (710, 745, 780, 5240, 5500, 5785MHz) 10V/m (80-2700MHz) IEC/EN61000-4-3:2006 + A2:2010, Criteria A 27V/m (385MHz) 28V/m (450, 810, 870, 930, 1720, 1845, 1970, 2450MHz) AC Por:t L, N, L-N ±2kV IEC/EN61000-4-4:2012, Criteria A AC Port L-N: ±0.5, 1, 2kV L-PE, N-PE: ±0.5, 1, 2, 4kV IEC/EN61000-4-5:2014, Criteria B AC Port: 3Vrms (0.15-80MHz) 6Vrms (IMS Band) IEC61000-4-6:2013, Criteria A EN61000-4-6:2014, Criteria A Power Magnetic Field Immunity 30A/m IEC61000-4-8:2009, Criteria A EN61000-4-8:2010, Criteria A Voltage Dips and Interruptions Voltage Dips 30% Voltage Dips 100% (0.5P) Voltage Dips 100% (1.0P) Voltage Interruptions 100% Surge Immunity Immunity to conducted disturbances, induced by radio-frequency fields IEC/EN61004-11:2004, Criteria A IEC/EN61004-11:2004, Criteria A IEC/EN61004-11:2004, Criteria A IEC/EN61004-11:2004, Criteria B continued on next page www.recom-power.com REV.: 1/2021 PA-5 RACM40-K AC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) EMC Compliance (Industrial) Condition Electromagnetic compatibility of multimedia equipment – Emission Requirements LCS200616044BE Electromagnetic compatibility of multimedia equipment – Immunity requirements Air ±2, 4, 8kV; Contact ±2, 8kV ESD Electrostatic discharge immunity test 3V/m (4800-1000MHz, 1800, 2600, 3500, 5000MHz) Radiated, radio-frequency, electromagnetic field immunity test Fast Transient and Burst Immunity IEC/EN61000-4-3:2006 + A2:2010, Criteria A IEC/EN61000-4-5:2014, Criteria B 1A/m Voltage Dips and Interruptions Voltage Dips 30% Voltage Dips 100% Voltage Interruptions 100% EMC Compliance (Low voltage power supply) Condition Low voltage power supplies, d.c. output Part 3: Electromagnetic compatibility (EMC) LCS200616049BE Air ±2, 4, 8kV; Contact ±2, 8kV 10V/m (80-1000MHz) 3V/m (1400-2000MHz) 1V/m (2000-2700MHz) Fast Transient and Burst Immunity IEC61000-4-2:2008 , Criteria A EN61000-4-2:2009, Criteria A IEC/EN61000-4-4:2012, Criteria B Power Magnetic Field Immunity Radiated, radio-frequency, electromagnetic field immunity test EN55035:2017 AC Port: L-N: ±1kV AC Port: 3Vrms (0.15-80MHz) 3Vrms (10-30MHz) 1Vrms (30-80MHz) ESD Electrostatic discharge immunity test EN55032:2015 AC Port: L, N, L-N ±1kV Surge Immunity Immunity to conducted disturbances, induced by radio-frequency fields Standard / Criterion IEC61000-4-6:2013, Criteria A EN61000-4-6:2014, Criteria A IEC61000-4-8:2009, Criteria A EN61000-4-8:2010, Criteria A IEC/EN61004-11:2004, Criteria C IEC/EN61004-11:2004, Criteria B IEC/EN61004-11:2004, Criteria C Standard / Criterion IEC/EN61204-3:2018 IEC61000-4-2:2008 , Criteria A EN61000-4-2:2009, Criteria A IEC/EN61000-4-3:2006 + A2:2010, Criteria A AC Port: L, N, L-N ±2kV IEC/EN61000-4-4:2012, Criteria B AC Port: L-N: ±1kV IEC/EN61000-4-5:2014, Criteria B Surge Immunity AC Port: 10Vrms (0.15-80MHz) IEC61000-4-6:2013, Criteria A EN61000-4-6:2014, Criteria A Power Magnetic Field Immunity 30A/m IEC61000-4-8:2009, Criteria A EN61000-4-8:2010, Criteria A Voltage Dips and Interruptions Voltage Dips 20, 30,60% Voltage Dips 100% (0.5P) Voltage Dips 100% (1.0P) Voltage Interruptions 100% Immunity to conducted disturbances, induced by radio-frequency fields Limits of Voltage Fluctuations & Flicker IEC/EN61004-11:2004, Criteria C IEC/EN61004-11:2004, Criteria B IEC/EN61004-11:2004, Criteria B IEC/EN61004-11:2004, Criteria C EN61000-3-3:2013 Limitations on the amount of electromagnetic interference allowed from digital and electronic devices FCC 47 CFR Part 15 Subpart B, Class B Limitations on the amount of electromagnetic interference allowed from digital and electronic devices, industrial, scientific, and medical equipment FCC 47 CFR Part 18 DIMENSION AND PHYSICAL CHARACTERISTICS Parameter Material Type PCB potting baseplate Dimension (LxWxH) Value FR4, (UL94 V-0) PU, (UL94 V-0) plastic, (UL94V-0) 83.23 x 46.43 x 30.40mm Weight 185g typ. continued on next page www.recom-power.com REV.: 1/2021 PA-6 RACM40-K AC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) Dimension Drawing (mm) 83.23 General tolerances according to ISO 2768-m (table for reference only) 46.43 Dimension range 0.5 - 6 mm 6 - 30 mm 30 - 120 mm 120 - 400 mm Tolerances ±0.1 mm ±0.2 mm ±0.3 mm ±0.5 mm 4.00 Ø1.60 6 5 4 3 1 2 5.63 2x M3 8.58 68.89 2 1 Top View 3x 3.96 FC 35.10 21.04 7.92 Pinning information Pin # Function 1 VAC in (N) 2 VAC in (L) 3 -Vout 4 -Vout 5 +Vout 6 +Vout Recommend Footprint Details FC 72.7 17.78 5.23
RACM40-05SK-T 价格&库存

很抱歉,暂时无法提供与“RACM40-05SK-T”相匹配的价格&库存,您可以联系我们找货

免费人工找货