RACT12-350

RACT12-350

  • 厂商:

    RECOM

  • 封装:

    -

  • 描述:

    RACT12-350

  • 数据手册
  • 价格&库存
RACT12-350 数据手册
Features TRIAC Dimmable LED Driver • Triac –dimmable with leading or trailing edge dimmers • Class II with SELV output (no earth required) • Extra-large screw terminals and integrated cable clamps for easy installation • Power factor corrected >0.95 • Dimming range 1..100% • Compatible with a wide range of dimmers Description AC/DC Converter RACT12 12 Watt 3 TRIAC Dimmable Single Output YEA R y arrant w The RACT12-xxx series are low cost, triac-dimmable, constant current 12W LED drivers available with either 300mA, 350mA, 500mA or 700mA full-range outputs. The drivers are Class II (double insulated) meaning no earth connection is required. The phase angle dimming works with leading or trailing edge dimmers. The RACT12 is suitable for indoor locations up to 50°C ambient temperature and is certified for building into furniture for applications such as dimmable shelf lighting, cove lighting or accent lighting. It is CE marked (LVD + EMC + RoHS), EAC and has IEC61347-1/IEC61347-2-13 CB report certification. Selection Guide Input Output Output Efficiency Output Voltage Range Voltage Range Current min. @rated load Power [VAC] [VDC] [mA] [%] [W] T RE M CONVER T C M TS TS compliant PL U D IA N T PRO CO 10 from 10 O REACH compliant M C C CONVER RoHS 2 + CO All LED Drivers may not be used without a load. They must be switched on the primary side only. Noncompliance may damage the LED or reduce its lifetime. M S 198-264 9-18 700 81 12 O R RACT12-700 C E 198-264 12-24 500 81 12 S RACT12-500 R 198-264 20-40 300 82 12 198-264 18-35 350 81 12 E RACT12-300 RACT12-350 RE Part Number PL U D IA N T PRO M M Model Numbering RACT12-___ Output Power Output Current IEC/EN61347 certified IEC/EN61347-2-13 certified EN61547 certified EN62493 certifed EN55015 compliant CB report Specifications (measured @ Ta= 25°C, 240VAC, rated load unless otherwise specified) BASIC CHARACTERISTICS Parameter Condition Input Voltage Range Min. Typ. Max. 198VAC 230VAC 264VAC Input Current Inrush Current 80mA full load 5A No Load Power Consumption 1W Input Frequency Range Power Factor 50Hz full load 60Hz 0.95 continued on next page www.recom-power.com REV.: 4/2020 L-1 RACT12 AC/DC Converter Series Specifications (measured @ Ta= 25°C, 240VAC, rated load unless otherwise specified) Parameter Condition THD Min. Typ. full load Max. 25% Start-up Time 500ms Internal Operating Frequency 60kHz 200mA Output Ripple Current (1) Notes: Note1: Measured at 20MHz BW by using a 12” twisted pair-wie terminated with a 0.1µF and 47µF capacitor parallel across output REGULATIONS Parameter Condition Value Output Accuracy ±5% typ. Load Regulation 5% max. Line Regulation 5% max. PROTECTION Parameter Condition Value Input Fuse fusible resistor Short Circuit Protection (SCP) Latch OFF, auto recovery after fault condition is removed 50VDC max. 42VDC max. 30VDC max. 26VDC max. RACT12-300 RACT12-350 RACT12-500 RACT12-700 Over Voltage Protection (OVP) Over Load Protection (OLP) Latch OFF, auto recovery after fault condition is removed Over Temperature Protection (OTP) Isolation Voltage Latch OFF, auto recovery after fault condition is removed 110°C I/P to O/P Latch OFF, auto recovery after fault condition is removed tested for 1 minute 3.75kVAC Leakage Current 5mA max. Maximum loading of automatic circuit breakers* * @ 230VAC, 1Ohm, 90° phase angle and max. load Circuit Breaker Typ Circuit Breaker Current 10A 16A 20A 25A B 36 57 69 85 C 57 87 109 134 ENVIRONMENTAL Parameter Operating Temperature Range Condition without derating @ natural convection 0.1m/s (see graph) Max. Case Temperature Operating Humidity Value at tc point +80°C max. non-condensing 5-85% RH IP Rating IP20 Pollution Degree Design Lifetime -20°C to +50°C PD2 RACT12-300 all others +25°C ambient >40 x 103 hours >30 x 10³ hours continued on next page www.recom-power.com REV.: 4/2020 L-2 RACT12 AC/DC Converter Series Specifications (measured @ Ta= 25°C, 240VAC, rated load unless otherwise specified) Derating Graph (@ Chamber and natural convection 0.1m/s) 100 90 Output Load [%] 80 70 60 50 40 30 20 10 0 -20 -10 0 10 20 30 40 50 60 Ambient Temperature [°C] SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report Number Standard Lamp controlgear Part 1: General and safety requirements (CB Scheme) 325797 IEC61347-1:2007 2nd Edition + A2:2012 Lamp controlgear Part 2-13: Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules (CB Scheme) 325797 IEC61347-2-13:2014 2nd Edition Lamp controlgear Part 1: General and safety requirements (LVD) EN61347-1:2015 Lamp controlgear Part 2-13: Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules (LVD) EN61347-2-13:2014 + A1:2017 Lamp controlgear Part 1: General and safety requirements 325797 EN61347-1:2008 + A2:2013 Lamp controlgear Part 2-13: Particular requirements for d.c. or a.c. supplied electronic controlgear for LED modules 325797 EN61347-2-13:2014 EAC RU-AT.49.09571 RoHS 2+ TP TC 004/2011 RoHS 2011/65/EU + AM2015/863 EMC Compliance Condition Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment Equipment for general lighting purposes – EMC immunity requirements Assessment of lighting equipment related to human exposure to electromagnetic fields ESD Electrostatic discharge immunity test EN55015:2013 + A1:2015 305985 EN61547:2009 EN62493:2015 Air ±8kV, Contact ±4kV Radiated, radio-frequency, electromagnetic field immunity test Standard / Criterion 3V/m EN61000-4-2:2009, Criteria A EN61000-4-3:2006 + A2:2010, Criteria A Fast Transient and Burst Immunity AC Power Port: ±1kV DC Power Port: ±0.5kV EN61000-4-4:2012, Criteria A Surge Immunity AC Power Port: ±0.5kV EN61000-4-5:2014, Criteria A Immunity to conducted disturbances, induced by radio-frequency fields Voltage Dips and Interruptions Voltage Dips and Interruptions 3V/m EN61000-4-6:2014, Criteria A Voltage Dips >95% EN61000-4-11:2004, Criteria B Voltage Dips 30% EN61000-4-11:2004, Criteria B Limits of Harmonic Current Emissions EN61000-3-2:2014, Class C Limits of Voltage Fluctuations & Flicker EN61000-3-3:2013, Clause 5 www.recom-power.com REV.: 4/2020 L-3 RACT12 AC/DC Converter Series Specifications (measured @ Ta= 25°C, 240VAC, rated load unless otherwise specified) DIMENSION and PHYSICAL CHARACTERISTICS Parameter Type Value Material case PCB plastic (UL94V-0) FR4 (UL94V-0) Package Dimension (LxWxH) 109.0 x 40.0 x 22.0mm Package Weight 70g typ. Dimensions Drawing (mm) 109.0 SEC wire stripping length: 6-7mm recommended tightening torque: 0.25Nm tc= case temperature measuring point FC = fixing centers Tolerance: xx.x= ±1.0mm xx.xx= ±0.5mm 20.0 22.0 - PRI L 40.0 + N Bottom View tc 39.0 Connection via Screw Terminal Function VAC in (N) VAC in (L) LED+ LED- FC 13.3 without cable cover`s PRI L Top View Notes: Note2: The use of sleeve or ferrule terminations is recommended + SEC N 15.4 10.0 15.0 R1.7 66.1 - 27.5 Solid Wire Stranded Wire (2) AWG 0.75-2.5mm² 0.75-2.5mm² 20-14 0.75-2.5mm² 0.75-2.5mm² 20-14 0.5-2.5mm² 0.5-2.5mm² 21-14 0.5-2.5mm² 0.5-2.5mm² 21-14 6.4 www.recom-power.com REV.: 4/2020 L-4 RACT12 AC/DC Converter Series Specifications (measured @ Ta= 25°C, 240VAC, rated load unless otherwise specified) INSTALLATION and APPLICATION Dimming Type Value AC phase-cut Connection work with leading/trailing edge dimmers LN LED+ LED- PACKAGING INFORMATION Parameter Packaging Dimension (LxWxH) Type cardboard box Packaging Quantity 10pcs Storage Temperature Range Storage Humidity Value 270.0 x 127.0 x 48.0mm -20°C to +70°C non-condensing 5-85% RH The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV.: 4/2020 L-5
RACT12-350 价格&库存

很抱歉,暂时无法提供与“RACT12-350”相匹配的价格&库存,您可以联系我们找货

免费人工找货
RACT12-350
  •  国内价格 香港价格
  • 1+116.942821+15.10810
  • 30+99.3620430+12.83680
  • 60+95.6884460+12.36220
  • 120+92.10231120+11.89890

库存:4

RACT12-350
  •  国内价格 香港价格
  • 1+133.737651+17.27786
  • 5+122.235765+15.79191
  • 10+117.5757710+15.18988
  • 25+111.6918725+14.42972
  • 50+107.4294850+13.87906
  • 100+103.32722100+13.34908
  • 250+98.13861250+12.67875
  • 500+94.38375500+12.19365

库存:3

RACT12-350
    •  国内价格
    • 1+105.41928
    • 10+103.30527
    • 20+100.21236
    • 50+97.20276
    • 100+95.24496

    库存:16