Features
• High efficiency uo to 84% full load
• Low deviation (10% - 100% load)
• 1kVDC and 2kVDC isolation option
• UL60950-1 and EN/IEC60950-1 certified
• -40°C to +100°C operating temperature range
• 1W SIP7 package
Unregulated
Converters
Description
The RB/E series is an unregulated DC/DC converter in standard SIP7 package style. This series has been
designed to offer exceptionally high efficiency at low loads, an extended operating temperature range
and low deviation (10% to 100%). Uses include applications with restricted energy budget and industrial
applications where a high efficiency level is required.
DC/DC Converter
RB/E
1 Watt
SIP7
Single Output
Selection Guide
Part
Number
nom. Input
Output
Output
Efficiency max. Capacitive
Voltage Voltage Current typ. (1) Load (2)
[VDC] [VDC] [mA] [%]
[µF]
RB-3.305S/E (3,4)
3.3 5 200 83 2200
(3,4)
5
5 200 84 2200
RB-1205S/E (3,4)
12
5 200 84 2200
24
5 200 81 2200
RB-0505S/E
RB-2405S/E
(3,4)
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Max Cap Load is tested at nominal input and full resistive load and is defined as the
capacitive load that will allow start up in under 1s without damage to the converter
E358085
Model Numbering
UL60950-1 certified
CAN/CSA-C22.2 No 60950-1 certified
EN60950-1 certified
IEC60950-1 certified
RB- __ 05S/E
nom. Input Voltage
Output Voltage
Protection (3)
Isolation Option (4)
Single
Notes:
Note3: standard part is without continuous short circuit protection
add suffix „/P“ for continuous short circuit protection
Note4: add suffix „/H“ for 2kVDC isolation
or add suffix „/HP“ for 2kVDC isolation and continuous short circuit protection
Ordering Examples:
RB-1205S/E: 12VDC Input Voltage, 5VDC Output Voltage, Single Output
RB-3.305S/EP: 3.3VDC Input Voltage, 5VDC Output Voltage, Single Output with continuous short circuit protection
RB-0505S/EH: 5VDC Input Voltage, 5VDC Output Voltage, Single Output with 2kVDC isolation
RB-0505S/EHP: 5VDC Input Voltage, 5VDC Output Voltage, Single Output with 2kVDC isolation and continuous short circuit protection
www.recom-power.com
REV.: 1/2018
ECO-1
RB/E
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up otherwise stated)
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Max.
Internal Input Filter
type
Input Voltage Range
±10%
Start-uo time
250ms
0%
Minimum Load
Internal Operating Frequency
(5)
20kHz
Output Ripple and Noise
90kHz
20MHz BW
50mVp-p
100mVp-p
Notes:
Note5: Operation below 10% load will not harm the converter, but specifications may not be met
Efficiency vs. Load
RB-xx05S/E
100
90
Efficiency [%]
80
70
60
50
40
30
3.305
0505
1205
2405
20
10
0
0
10
20
30
40
50
60
70
80
90
100
Output Load [%]
REGULATIONS
Parameter
Condition
Value
Output Accuracy
±5.0% max.
Line Regulation
low line to high line
±1.2% max.
Load Regulation
10% to 100% load
12.0% typ.
Tolerance Envelope
Output Voltage [%]
+10%
+5%
Typical L
o
+5%
ad Line
Vnom
-2%
-5%
10
50
100
Output Load [%]
continued on next page
www.recom-power.com
REV.: 1/2018
ECO-2
RB/E
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up otherwise stated)
Deviation vs. Load
RB-xx05S/E
25
3.305
0505
1205
2405
20
Deviation [%]
15
10
5
0
-50
-10
0
10
20
30
40
50
60
70
80
90
100
Output Load [%]
PROTECTIONS
Parameter
Type
Value
without suffix
With suffix “/P”
Short Circuit Protection (SCP)
1 second
continuous
without suffix
tested for 1 second
rated for 1 minute
1kVDC
500VAC
with suffix
“/H”
tested for 1 second
rated for 1 minute
Isolation Resistance
2kVDC
1kVDC
10GΩ min.
Isolation Capacitance
75pF max.
Isolation Voltage (6)
I/P to O/P
Insulation Grade
basic
Notes:
Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note7: Refer to local wiring regulations if input over-current protection is also required. Recommended fuse: T1A slow blow type
ENVIRONMENTAL
Parameter
Operating Temperature Range
Condition
Value
full load @ free air convection (see graph)
Operating Altitude
Operating Humidity
-40°C to + 100°C
2000m
non-condensing
95% RH max.
Pollution Degree
MTBF
PD2
according to MIL-HDBK-217F, G.B.
+25°C
+100°C
3459 x 10 hours
756 x 103 hours
3
continued on next page
www.recom-power.com
REV.: 1/2018
ECO-3
RB/E
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up otherwise stated)
Derating Graph
(@ free air convection)
100
90
Output Load [%]
80
70
60
50
40
30
20
10
0
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110
Ambient Temperature [°C]
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report / File Number
Information Technology Equipment, General Requirements for Safety
1602031
Information Technology Equipment, General Requirements for Safety
E358085-A4-UL
EAC
RU-AT.49.09571
RoHs 2+
Standard
IEC60950-1:2005, 2nd Edition + A2:2013
EN60950-1:2006 + A2:2013
UL60950-1, 2nd Edition:2007
CAN/CSA C22.2 No. 60950-1-03, 2nd Edition:2007
TP TC 004/2011
RoHS-2011/65/EU + AM-2015/863
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter
Type
Value
Material
case
potting
PCB
non-conductive black plastic (UL94 V-0)
epoxy, (UL94 V-0)
FR4, (UL94 V-0)
Dimension (LxWxH)
19.6 x 6.0 x 10.2mm
Weight
2.2g typ.
continued on next page
www.recom-power.com
REV.: 1/2018
ECO-4
RB/E
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up otherwise stated)
Dimension Drawing (mm)
embossed logo
19.6
10.2
6.0
Pinning information
Pin #
1
2
4
5
6
0.50
Marking
2.00
4 5 6
5x2.54= 12.70
4.10
Recommended Footprint Details
1.00 Ø +0.15/-0
2.54
Bottom View
1 2
0.25±0.05
1.27
0.51+0.10/-0.05
1 2
Single
+Vin
-Vin
NC
-Vout
+Vout
NC = no internal connection
Tolerance:
xx.x= ±0.5mm
xx.xx= ±0.25mm
4 5 6
Top View
2.54
PACKAGING INFORMATION
Parameter
Type
Value
Packaging Dimension (LxWxH)
tube
520.0 x 16.0 x 9.0mm
Packaging Quantity
tube
Storage Temperature Range
25pcs
-55°C to +125°C
Storage Humidity
95% RH max.
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 1/2018
ECO-5
很抱歉,暂时无法提供与“RB-0505S/E”相匹配的价格&库存,您可以联系我们找货
免费人工找货- 国内价格 香港价格
- 1+69.898401+9.04762