Features
Regulated
Converters
●
●
●
●
●
●
●
●
Description
10W in 2” x 1” Package
2kVDC and 3kVDC Isolation Options
2:1 or 4:1 Input Voltage Range
Continuous Short Circuit Protection
(power limiting)
Synchronous Rectification on all Del outputs
Full SMD internal design
Remote Control Pin
Efficiency to 87%
The REC10-xxxxS_D/M -series offer single and dual regulated outputs in a 2”x1” package with
2kVDC or 3kVDC isolation options and are suitable for higher power industrial applications. Remote on/off control is standard. The converters can deliver 150% rated power for short periods
of time to cope with applications with large capacitive loads or high start up currents.
Selection Guide
Part
Number
Input
Voltage
(VDC)
Output
Voltage
(VDC)
Output
Current
(mA)
REC10-xx3.3S/H*/M
9-18, 18-36, 36-75
3.3
2000
83-84
2200µF
REC10-xx05S/H*/M
9-18, 18-36, 36-75
5
2000
86-87
2200µF
REC10-xx12S/H*/M
9-18, 18-36, 36-75
12
833
85-86
2200µF
REC10-xx15S/H*/M
9-18, 18-36, 36-75
15
667
85-86
2200µF
REC10-xx05D/H*/M
9-18, 18-36, 36-75
±5
±1000
82-83
±1000µF
REC10-xx12D/H*/M
9-18, 18-36, 36-75
±12
±416
85-86
±1000µF
REC10-xx15D/H*/M
9-18, 18-36, 36-75
±15
±333
85-86
±1000µF
REC10-xx3.3SZ/H*/M
9-36, 18-75
3.3
2000
82
2200µF
REC10-xx05SZ/H*/M
9-36, 18-75
5
2000
86
2200µF
REC10-xx12SZ/H*/M
9-36, 18-75
12
833
85
2200µF
REC10-xx15SZ/H*/M
9-36, 18-75
15
667
86
2200µF
REC10-xx05DZ/H*/M
9-36, 18-75
±5
±1000
82
±1000µF
REC10-xx12DZ/H*/M
9-36, 18-75
±12
±416
85
±1000µF
REC10-xx15DZ/H*/M
9-36, 18-75
±15
±333
86
±1000µF
* Standard is /H2 for 2kVDC isolation,
use /H3 for 3kVDC Isolation
2:1
xx = 9-18Vin = 12,
xx = 18-36Vin = 24,
xx = 36-75Vin = 48
Efficiency Max. Cap.
(typ.)
Load
(%)
ECONOLINE
DC/DC-Converter
with 3 year Warranty
10 Watt
2” x 1”
Single & Dual
Output
RoHS
2011/65/EU
6/6
E-224736
EN-60950-1 Certified
EN-60601-1 Certified
UL-60950-1 Certified
REC10/M
4:1
xx = 9-36Vin = 24,
xx = 18-75Vin = 48
Specifications (measured at TA = 25°C, nominal input voltage, full load and after warm-up)
Input Voltage Range
2:1 or 4:1
Input Filter
PI Network
Output Voltage Accuracy (the Output 3.3V is ±1.2% max.)
±1.0% max.
Line Voltage Regulation
±0.3% max.
Load Voltage Regulation
Single
±0.5% max.
(25% to 100% full load )
Dual
±1.2% max.
Cross Regulation (100%: 25% to 100% full load )
Output Ripple and Noise (with 100n output capacitor and 20MHz BW)
±5% max.
100mVp-p max.
Start-up time (Nom. Vin at 100% Load)
25ms typ.
Operating Frequency (Full Load)
300kHz typ.
Efficiency (Nom. Vin at 100% Load)
see Selection Guide
Minimum Load
Input Surge Voltage (100ms max.)
0%
12V Input
36VDC
24V Input
50VDC
48V Input
100VDC
continued on next page
E-166
**Any data referred to in this datasheet are of indicative nature
and based on our practical experience only. For further details,
please refer to our Application Notes.
REV: 0/2015
Refer to Application Notes
www.recom-power.com
REC10-S_D/H*/M
Series
ECONOLINE
DC/DC-Converter
Specifications cont. (measured at TA = 25°C, nominal input voltage, full load and after warm-up)
Derating-Graph
H2-Suffix
(tested for 1 second)
2000VDC
(rated for 1 minute)
1000VAC / 60Hz
H3-Suffix
(tested for 1 second)
3000VDC
(rated for 1 minute)
1500VAC / 60Hz
Under Voltage Lockout (2:1)
12V Input
DC-DC on 8.3VDC, DC-DC off 7.9VDC
24V Input
DC-DC on 17.4VDC, DC-DC off 16.7VDC
48V Input
DC-DC on 35.7VDC, DC-DC off 34.3VDC
Under Voltage Lockout (4:1)
24V Input
DC-DC on 8.3VDC, DC-DC off 7.9VDC
48V Input
DC-DC on 17.4VDC, DC-DC off 16.7VDC
Isolation Capacitance
1200pF typ.
Isolation Resistance
1 GΩ min.
Overload Protection
150% typ.
Short Circuit Protection
Continuous, Auto Restart
Operating Temperature Range
4:1
-40°C to +71°C (see Graph)
(free air convection)
2:1
-40°C to +81°C (see Graph)
Storage Temperature Range
-55°C to +105°C
Remote On/Off
DC/DC ON
Open or 3.5V
很抱歉,暂时无法提供与“REC10-1205D/H3/M”相匹配的价格&库存,您可以联系我们找货
免费人工找货