Features
•
•
•
•
•
Regulated
Converters
4:1 wide input voltage range
Compact size 1“x1“ package
Efficiency up to 90%
Wide operating temperature from
-40°C to +75°C without derating
Continuous short circuit protection
Description
DC/DC Converter
REC15E-Z
15 Watt
3
1“ x 1“
Single and Dual
Output
YEA R
The REC15E-Z series are 4:1 wide input voltage range 15W power DC/DC converters in a 1”x1” case.
Despite their low cost, the converters are fully specified devices with output currents up to 4 Amps,
no minimum load, 1.6kVDC isolation, high efficiency and low ripple/noise figures. The inputs are
protected against transients of up to 100V and feature UVLO to allow the primary supply to start up
safely. The single or dual outputs are continuously protected against short circuits and overload and
can drive high capacitive loads. The REC15E-Z series will find many uses in cost sensitive applications
where board space is at a premium.
wa
rranty
Selection Guide
Part
Number
nom. Input
Output
Output
Efficiency max. Capacitive
Voltage Range
Voltage
Current
typ. (1) Load (2)
[VDC] [VDC] [mA] [%]
[µF]
REC15E-243.3SZ (3)
9 - 36
3.3
4000
85
12000
REC15E-2405SZ
REC15E-2412SZ (3)
9 - 36
5
9 - 36
12
3000
88
6400
1250
88.5
1200
REC15E-2415SZ
9 - 36
15
REC15E-2424SZ (3)
9 - 36
24
1000
89
900
625
89.5
240
REC15E-2412DZ
9 - 36
±12
±625
87
±520
REC15E-2415DZ
(3)
9 - 36
±15
±500
89
±330
REC15E-483.3SZ
18 - 75
3.3
4000
85
12000
REC15E-4805SZ (3)
18 - 75
5
3000
88
6400
REC15E-4812SZ (3)
18 - 75
12
1250
89
1200
REC15E-4815SZ (3)
18 - 75
15
1000
89.5
900
(3)
(3)
(3)
(3)
REC15E-4824SZ
18 - 75
24
625
90
240
REC15E-4812DZ (3)
18 - 75
±12
±625
89.5
±520
REC15E-4815DZ (3)
18 - 75
±15
±500
89.5
±330
(3)
E224736
UL62368-1 certified
CAN/CSA-C22.2 No. 62368-1-14 certified
UL60950-1 certified
CAN/CSA-C22.2 No. 60950-1-0 certified
IEC/EN62368-1 certified
EN55032 compliant
EN55024 compliant
CB report
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Max Cap Load is tested at nominal input and full resistive load
Model Numbering
REC15E-__ __ _ Z/X2
nom. Input Voltage
Pinning (3)
Output Voltage
4:1 Input
Single or Dual
Notes:
Note3: “/X2” is without ON/OFF CTRL and without Output Voltage Trimming
If the CTRL option is not chosen, pin3 (+ pin5 for single output) will be absent
Refer to „Dimension Drawing (mm)“
Ordering Examples:
REC15E-2405SZ
REC15E-4812DZ
REC15E-2412SZ/X2
9-36Vin, 5Vout , Single output, 4:1 input
18-75Vin, ±12Vout, Dual output, 4:1 input
9-36Vin, 12Vout , Single output , 4:1 input, without ON/OFF CTRL and without Output Voltage Trimming
www.recom-power.com
REV.: 2/2019
ECO-1
REC15E-Z
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Max.
Internal Input Filter
Pi type
nom. Vin= 24VDC
nom. Vin= 48VDC
nom. Vin= 24VDC
100ms max.
nom. Vin= 48VDC
Input Voltage Range
Input Surge Voltage
9VDC
18VDC
24VDC
48VDC
50VDC
100VDC
nom. Vin= 24VDC
DC-DC ON
DC-DC OFF
7.5VDC
nom. Vin= 48VDC
DC-DC ON
DC-DC OFF
16VDC
Under Voltage Lockout (UVLO)
Input Current
nom. Vin= 24VDC
nom. Vin= 48VDC
Quiescent Current
nom. Vin= 24VDC
nom. Vin= 48VDC
36VDC
75VDC
9VDC
18VDC
700mA
350mA
7mA
5mA
refer to „OUTPUT TRIM“
Output Voltage Trimming
±10%
Minimum Load
0%
Start-up Time
20ms
ON/OFF CTRL
DC-DC ON
DC-DC OFF
Standby Current
DC-DC OFF
25ms
Open or 3.5VCTRL - 15VDC
Short or 0VCTRL - 1.2VDC
2mA
Internal Operating Frequency
350kHz
nom. Vin= 24VDC
nom. Vin= 48VDC
20MHz BW
Output Ripple and Noise (4)
60mVp-p
100mVp-p
Notes:
Note4: Measurements are made with a 1µF MLCC across output. (low ESR)
Efficiency vs. Load
REC15E-2412SZ
100
100
90
90
80
80
70
70
Efficiency [%]
Efficiency [%]
REC15E-2405SZ
60
50
40
30
10
0
0
10
20
30
40
50
60
70
80
90
50
40
30
9Vin
12Vin
24Vin
36Vin
20
60
9Vin
12Vin
24Vin
36Vin
20
10
100
Output Load [%]
0
0
10
20
30
40
50
60
70
80
90
100
Output Load [%]
continued on next page
www.recom-power.com
REV.: 2/2019
ECO-2
REC15E-Z
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
REC15E-4824SZ
REC15E-4805SZ
100
100
90
90
80
80
70
70
60
50
40
18Vin
24Vin
36Vin
48Vin
54Vin
75Vin
30
20
10
0
0
10
20
30
40
50
60
70
80
90
60
50
40
20
10
0
100
80
80
70
70
60
50
40
30
40
50
60
10
40
50
60
70
80
90
70
80
100
50
40
18Vin
24Vin
36Vin
48Vin
54Vin
75Vin
20
10
0
100
90
60
30
9Vin
12Vin
24Vin
36Vin
20
30
30
REC15E-4812DZ
90
20
20
REC15E-2415DZ
90
10
10
Output Load [%]
100
0
0
Output Load [%]
100
0
18Vin
24Vin
36Vin
48Vin
54Vin
75Vin
30
Efficiency [%]
Efficiency [%]
Efficiency [%]
Efficiency [%]
Efficiency vs. Load
0
10
20
30
Output Load [%]
40
50
60
70
80
90
100
Output Load [%]
OUTPUT TRIM
Output Voltage Trimming
It allows the user to increase or decrease the output voltage of the module. This is accomplished by connecting an external resistor between the Trim pin and either
the +Vout or -Vout pins. With an external resistor between the -Vout and Trim pin, the output voltage increases. With an external resistor between the Trim and
+Vout pin, the output voltage decreases. The values for trim resistors shown in trim tables below are according to standard E96 values; therefore, the specified
voltage may slightly vary.
Trim up
Trim down
-Vout
Trim
Rup
Trim
Rdown
+Vout
continued on next page
www.recom-power.com
REV.: 2/2019
ECO-3
REC15E-Z
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Voutnom = nominal output voltage [VDC]
Voutset = trimmed output voltage [VDC]
Vref
= reference voltage
[VDC]
Rup
= trim up resistor
[W]
Rdown
= trim down resistor
[W]
R1, R2, R3 = internal resistors
[W]
ku
= trim up factor
[ ]
kd
= trim down factor
[ ]
Calculation:
ku=
kd=
Vref
Voutset - Vref
Voutset - Vref
Vref
Voutnom
R1
3.3VDC
16k6Ω
R2
R3
Vref
52k3Ω
1.24VDC
5VDC
10kΩ
12VDC
38k1Ω
15VDC
50k1Ω
51kΩ
24VDC
86k32Ω
73k2Ω
x R1
Rup =
x R2
Rdown =
35k7Ω
10kΩ
ku x R2
R2 - ku
kd x R1
R1 - kd
48k7Ω
2.5VDC
- R3
- R3
Practical Example REC15-0505SZ trim up 10%
ku =
2.5
5.5 - 2.5
Rup =
x 10k = 8k33
8k33 x 10k
10k - 8k33
- 35K7 = 14k2W
Rup according to E96 ≈ 14k3W
Practical Example REC15-0505SZ trim down 10%
kd =
4.5 - 2.5
2.5
Rdown =
x 10k = 8k
8k x 10k
10k - 8k
- 35k7 = 4k3W
Rdown according to E96 ≈ 4k32W
REGULATIONS
Parameter
Condition
Value
Output Accuracy
Line Regulation
Load Regulation (5)
Cross Regulation
±1.0% max.
low line to high line, full load
Single
Dual
±0.2% max.
±0.5% max.
10% to 100% load
Single
Dual
0.5% max.
1.0% max.
dual output only
±5.0% max.
Notes:
Note5: Operation below 10% load will not harm the converter, but specifications may not be met
continued on next page
www.recom-power.com
REV.: 2/2019
ECO-4
REC15E-Z
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Deviation vs. Load
REC15E-Z
1.0
0.75
Deviation [%]
0.5
0.25
0
-0.25
-0.5
-0.75
-1.0
0
10
20
30
40
50
60
70
80
90
100
Output Load [%]
PROTECTIONS
Parameter
Type
Value
Short Circuit Protection (SCP)
continuous, automatic recovery
nom. Vin= 24VDC
nom. Vin= 48VDC
Over Current Protection (OCP)
170%, hiccup mode
190%, hiccup mode
Isolation Capacitance
1200pF typ.
Isolation Resistance
2kVDC
1.6kVDC
1GΩ min.
Isolation Grade
functional
Isolation Voltage (6)
tested for 1 second
tested for 1 minute
I/P to O/P
Notes:
Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note7: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type
ENVIRONMENTAL
Parameter
Operating Temperature Range (8)
Condition
Value
full load @ free air convection
refer to „Derating Graph“
-40°C to +75°C
-40°C to +105°C
Maximum Case Temperature
+110°C
Temperature Coefficient
Thermal Impedance (8)
± 0.02%/K
0.1m/s, horizontal
15.9K/W
Operating Altitude
Operating Humidity
5000m
non-condensing
5% - 95% RH max.
Pollution Degree
PD2
Vibration
MTBF
according to MIL-STD-202G standard
according to MIL-HDBK-217F, G.B.
+25°C
+75°C
1400 x 103 hours
354 x 103 hours
Notes:
Note8: Test PCB:160x100mm105µm (Eurocard), double layer
continued on next page
www.recom-power.com
REV.: 2/2019
ECO-5
REC15E-Z
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Derating Graph
(@ free air convection)
100
90
Output Load [%]
80
70
60
50
40
30
20
10
0
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110
75 85
105
Ambient Temperature [°C]
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report / File Number
Audio/video, information and communication technology equipment - Safety
requirements
E224736
Information Technology Equipment, General Requirements for Safety
Audio/video, information and communication technology equipment - Safety
requirements (CB Scheme)
Audio/video, information and communication technology equipment - Safety
requirements
Standard
UL62368-1, 2nd Edition, 2014
CAN/CSA -C22.2 No. 62368-1-14, 2nd Edition
UL60950-1, 2nd Edition, 2014
CAN/CSA C-22.2 No. 60950-1-07, 2nd Edition
IEC62368-1:2014, 2nd Edition
WD-ITAC-180737-A0
EN62368-1:2014 + A11:2017
RoHS2
RoHS 2011/65/EU + AM2015/863
EMC Compliance (pending)
Electromagnetic compatibility of multimedia equipment Emission requirements
Condition
Standard / Criterion
without external filter
refer to „EMC Filtering“
EN55032:2015, Class B
ESD Electrostatic discharge immunity test
Radiated, radio-frequency, electromagnetic field immunity test (9)
Contact: ±2, 4kV
3V/m
Fast Transient and Burst Immunity (9)
Surge Immunity
IEC61000-4-2:2009, Criteria A
IEC61000-4-3:2006 + A2:2010, Criteria A
DC Power Port ±0.5, 1kV
(9)
IEC61000-4-4:2012, Criteria A
DC Power Port ±0.5kV
IEC61000-4-5:2014 + A1:2017, Criteria A
DC Pwoer Port 3V
DC Output Port 3V
IEC61000-4-6:2013 + C1:2015, Criteria A
Immunity to conducted disturbances, induced by radio-frequency fields (9)
Power Magnetic Field Immunity (9)
1A/m (50Hz)
IEC61000-4-8:2010, Criteria A
Notes:
Note9: Measurements are made with E-Cap 220uF/100V at input terminal
continued on next page
www.recom-power.com
REV.: 2/2019
ECO-6
REC15E-Z
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
EMC Filtering Suggestions according to EN55032 Class B
Single Output
Dual Output
C3
C3
L1
L1
+VIN
+Vin
C1
+VIN
+VOUT
+Vout
+Vin
C1
C2
-Vin
-VIN
-Vout
C2
Com
-Vout
-Vin
-VIN
-VOUT
+Vout
+VOUT
Com
-VOUT
C4
C4
Component List Class B
MODEL
C1
REC15E-24xxS(D)Z
C2
C3
2.2µF/100V 2.2µF/100V 1500pF/2kV
REC15E-48xxS(D)Z
C4
L1
1500pF/2kV
4.7µH
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter
Type
Value
Material
case
potting
PCB
nickel plated metal
silicone, (UL94V-0
FR4, (UL94V-0
Dimension (LxWxH)
25.4 x 25.4 x 10.0mm
Weight
17g typ.
Dimension Drawing (mm)
Pinning information
25.4
5.6
10.0
25.4
2.54
8 x 2.54= 20.32
Ø 1.0±0.1
Recommended Footprint Details
2
Bottom View
3
www.recom-power.com
5
4
3
2
1
4
2.54
2.54
1
12.70
7.62
6
10.2
5.08
2.54
Top View
Pin #
1
2
3
4
5
6
Single
+Vin
-Vin
CTRL
-Vout
Trim
+Vout
Dual Single/X2 Dual/X2
+Vin
+Vin
+Vin
-Vin
-Vin
-Vin
CTRL
no pin
no pin
-Vout
-Vout
-Vout
Com
no pin
Com
+Vout
+Vout
+Vout
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.25mm
5
6
REV.: 2/2019
ECO-7
REC15E-Z
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
PACKAGING INFORMATION
Parameter
Type
Value
Packaging Dimension (LxWxH)
tube
260.0 x 28.5 x 20.8mm
Packaging Quantity
8pcs
Storage Temperature Range
-55°C to +125°C
Storage Humidity
95% RH max.
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 2/2019
ECO-8