RFM-0505S

RFM-0505S

  • 厂商:

    RECOM

  • 封装:

    SIP,11.5x6mm

  • 描述:

    RFM-0505S

  • 数据手册
  • 价格&库存
RFM-0505S 数据手册
• Low cost 1W converter • Industry standard pinout • SIP4 package • bullet points (Productmanager) • 1kVDC isolation • Efficiency up to 79% • Wide operating temperature range -40°C to +85°C • UL60950-1, CAN/CSA C22.2 No. 60950-1 certified Features Unregulated Converters Description The RFM DC/DC converter is typically used in cost sensitive general purpose power isolation and voltage matching applications. Despite its low cost, it is a fully specified converter with 1kVDC isolation, industrial operating temperature range of -40°C to +85°C without derating and UL/ EN certifications. DC/DC Converter RFM 1 Watt SIP4 Single Output Selection Guide Part Number Input Output Output Efficiency (1) Max. Capacitive Voltage Voltage Current typ. Load (2) [VDC] [VDC] [mA] [%] [µF] RFM-0505S 5 5 200 79 470 Notes: Note1: Efficiency is tested at nominal input and full load at +25°C ambient Note2: Max. Cap Load is tested at nominal input and full resistive load E358085 Model Numbering UL60950-1 certified CAN/CSA-C22.2 No 60950-1 certified EN55032 compliant RFM-05 05 S Input Voltage Single Output Voltage Specifications (measured @ Ta= 25°C, nominal input voltage, full load and after warm-up) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Internal Input Filter Input Voltage Range Input Current Quiescient Current Minimum Load (3) Max. capacitor ±10% max. load 250mA nom. Vin = 5VDC 25mA 30mA 80kHz 100kHz 0% Internal Operating Frequency Output Ripple and Noise (4) 50kHz 20MHz BW Reflected Back Ripple Current 20MHz BW, no external choke 50mVp-p 100mVp-p 20mAp-p Notes: Note3: Operation below 10% load won‘t harm the converter, but specifications may not be met Note4: Measurements are made with a 100nF MLCC across output (low ESR) continued on next page www.recom-power.com REV.: 0/2018 ECO-1 RFM DC/DC Converter Series Specifications (measured @ Ta= 25°C, nominal input voltage, full load and after warm-up) Efficiency vs. Load 100 (nominal Vin= 5VDC) 90 Efficiency [%] 80 70 60 50 40 30 20 10 0 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] REGULATIONS Parameter Condition Values Output Accuracy ±5.0% max. Line Regulation low line to high line, full load ±1.2% typ. / ±1% max. Load Regulation 10% to 100% ±10% typ. / ±15% max. Tolerance Envelope Output Voltage [%] +15% +5% Typical Load Line Vnom +5% -1% -5% 10 50 100 Output Load [%] PROTECTIONS Parameter Isolation Voltage Condition (5) I/P to O/P tested for 1 second Isolation Resistance 1kVDC 1GΩ min. Isolation Capacitance Leakage Current Value 75pF max. 500VAC, 50Hz Insulation Grade 1µA max. Functional Notes: Note5: For repeat Hi-Pot testing, reduce the time and/or the test voltage www.recom-power.com REV.: 0/2018 ECO-2 RFM DC/DC Converter Series Specifications (measured @ Ta= 25°C, nominal input voltage, full load and after warm-up) ENVIRONMENTAL Parameter Condition Operating Temperature Range Value (@ natural convection 0.1m/s) (see graph) without derating -40°C to +85°C Maximum Case Temperature +105°C Temperature Coefficient ±0.05%/°C Thermal Impedance 0.1m/s, horizontal direction 60°C/W Operating Altitude 2000m Operating Humidity non-condensing 95% RH max. Pollution Degree PD2 Vibration MIL-STD-202G MTBF 20100 x 103 hours 8700 x 103 hours +25°C +85°C according to MIL-HDBK-217F, G.B. Derating Graph (@ Chamber and natural convection 0.1m/s) 100 90 Output Load [%] 80 70 60 50 40 30 20 10 0 -40 -20 0 20 40 60 80 100 120 85 Ambient Temperature [°C] SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report/File Number Information Technology Equipment, General Requirements for Safety Standard UL60950-1, 2nd Edition, 2007 E358085-A4 CSA C22.2 No. 60950-1-07, 2nd Edition, 2007 RoHs 2+ RoHS 10/10, 2015 EMC Compliance Condition Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement Standard / Criterion with external filter (see below filter suggestion) EN55032, Class A, B EMC Filtering - Suggestions for Class A and B L1 Component List Class A C3 +Vin C1 L1 C2 C3 +Vout 6.8µF - - - -Vout C1 L1 C2 and C3 10µF 22µH 330pF/1kV C1 Component List Class B -Vin C2 www.recom-power.com REV.: 0/2018 ECO-3 RFM DC/DC Converter Series Specifications (measured @ Ta= 25°C, nominal input voltage, full load and after warm-up) DIMENSION AND PHYSICAL CHARACTERISTICS Parameter Type Value Material case potting non-conductive black plastic (UL94 V-0) epoxy (UL94 V-2) Package Dimension (LxWxH) 11.5 x 6.0 x 10.0mm Package Weight 1.4g Dimension Drawing (mm) embossed logo 6.0 0.51 Recommended Footprint Details 1.00 Ø +0.15/-0 2.54 1 2 3 4 Pin Connections Pin # Function 1 -Vin 2 +Vin 3 -Vout 4 +Vout 0.25 7.62 1.25 1.9 Marking 4.10 0.51 10.0 11.5 Top View Bottom View Tolerance: x x.x= ±0.5mm xx.xx= ±0.25mm Pin tolerance: Thickness: ±0.05mm Lenght: +0.25/-0.50mm 2.54 PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) tube 520.0 x 16.0 x 9.0mm Packaging Quantity 42pcs Storage Temperature Range -55°C to +125°C Storage Humidity 5% - 95%, RH The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV.: 0/2018 ECO-4
RFM-0505S 价格&库存

很抱歉,暂时无法提供与“RFM-0505S”相匹配的价格&库存,您可以联系我们找货

免费人工找货