• Low cost 1W converter
• Industry standard pinout
• SIP4 package
• bullet points (Productmanager)
• 1kVDC isolation
• Efficiency up to 79%
• Wide operating temperature range -40°C to +85°C
• UL60950-1, CAN/CSA C22.2 No. 60950-1 certified
Features
Unregulated
Converters
Description
The RFM DC/DC converter is typically used in cost sensitive general purpose power isolation and
voltage matching applications. Despite its low cost, it is a fully specified converter with
1kVDC isolation, industrial operating temperature range of -40°C to +85°C without derating and UL/
EN certifications.
DC/DC Converter
RFM
1 Watt
SIP4
Single Output
Selection Guide
Part
Number
Input
Output
Output Efficiency (1)
Max. Capacitive
Voltage Voltage Current typ. Load (2)
[VDC] [VDC] [mA] [%] [µF]
RFM-0505S
5
5
200 79
470
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Max. Cap Load is tested at nominal input and full resistive load
E358085
Model Numbering
UL60950-1 certified
CAN/CSA-C22.2 No 60950-1 certified
EN55032 compliant
RFM-05 05 S
Input Voltage
Single
Output Voltage
Specifications (measured @ Ta= 25°C, nominal input voltage, full load and after warm-up)
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Internal Input Filter
Input Voltage Range
Input Current
Quiescient Current
Minimum Load (3)
Max.
capacitor
±10%
max. load
250mA
nom. Vin = 5VDC
25mA
30mA
80kHz
100kHz
0%
Internal Operating Frequency
Output Ripple and Noise (4)
50kHz
20MHz BW
Reflected Back Ripple Current
20MHz BW, no external choke
50mVp-p 100mVp-p
20mAp-p
Notes:
Note3: Operation below 10% load won‘t harm the converter, but specifications may not be met
Note4: Measurements are made with a 100nF MLCC across output (low ESR)
continued on next page
www.recom-power.com
REV.: 0/2018
ECO-1
RFM
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nominal input voltage, full load and after warm-up)
Efficiency vs. Load
100
(nominal Vin= 5VDC)
90
Efficiency [%]
80
70
60
50
40
30
20
10
0
0
10
20
30
40
50
60
70
80
90 100
Output Load [%]
REGULATIONS
Parameter
Condition
Values
Output Accuracy
±5.0% max.
Line Regulation
low line to high line, full load
±1.2% typ. / ±1% max.
Load Regulation
10% to 100%
±10% typ. / ±15% max.
Tolerance Envelope
Output Voltage [%]
+15%
+5%
Typical Load
Line
Vnom
+5%
-1%
-5%
10
50
100
Output Load [%]
PROTECTIONS
Parameter
Isolation Voltage
Condition
(5)
I/P to O/P
tested for 1 second
Isolation Resistance
1kVDC
1GΩ min.
Isolation Capacitance
Leakage Current
Value
75pF max.
500VAC, 50Hz
Insulation Grade
1µA max.
Functional
Notes:
Note5: For repeat Hi-Pot testing, reduce the time and/or the test voltage
www.recom-power.com
REV.: 0/2018
ECO-2
RFM
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nominal input voltage, full load and after warm-up)
ENVIRONMENTAL
Parameter
Condition
Operating Temperature Range
Value
(@ natural convection 0.1m/s) (see graph)
without derating
-40°C to +85°C
Maximum Case Temperature
+105°C
Temperature Coefficient
±0.05%/°C
Thermal Impedance
0.1m/s, horizontal direction
60°C/W
Operating Altitude
2000m
Operating Humidity
non-condensing
95% RH max.
Pollution Degree
PD2
Vibration
MIL-STD-202G
MTBF
20100 x 103 hours
8700 x 103 hours
+25°C
+85°C
according to MIL-HDBK-217F, G.B.
Derating Graph
(@ Chamber and natural convection 0.1m/s)
100
90
Output Load [%]
80
70
60
50
40
30
20
10
0
-40 -20
0
20
40
60
80 100 120
85
Ambient Temperature [°C]
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report/File Number
Information Technology Equipment, General Requirements for Safety
Standard
UL60950-1, 2nd Edition, 2007
E358085-A4
CSA C22.2 No. 60950-1-07, 2nd Edition, 2007
RoHs 2+
RoHS 10/10, 2015
EMC Compliance
Condition
Information technology equipment - Radio disturbance
characteristics - Limits and methods of measurement
Standard / Criterion
with external filter
(see below filter suggestion)
EN55032, Class A, B
EMC Filtering - Suggestions for Class A and B
L1
Component List Class A
C3
+Vin
C1
L1
C2
C3
+Vout
6.8µF
-
-
-
-Vout
C1
L1
C2 and C3
10µF
22µH
330pF/1kV
C1
Component List Class B
-Vin
C2
www.recom-power.com
REV.: 0/2018
ECO-3
RFM
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nominal input voltage, full load and after warm-up)
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter
Type
Value
Material
case
potting
non-conductive black plastic (UL94 V-0)
epoxy (UL94 V-2)
Package Dimension (LxWxH)
11.5 x 6.0 x 10.0mm
Package Weight
1.4g
Dimension Drawing (mm)
embossed logo
6.0
0.51
Recommended Footprint Details
1.00 Ø +0.15/-0
2.54
1 2 3 4
Pin Connections
Pin #
Function
1
-Vin
2
+Vin
3
-Vout
4
+Vout
0.25
7.62
1.25
1.9
Marking
4.10
0.51
10.0
11.5
Top View
Bottom View
Tolerance: x x.x= ±0.5mm
xx.xx= ±0.25mm
Pin tolerance:
Thickness: ±0.05mm
Lenght: +0.25/-0.50mm
2.54
PACKAGING INFORMATION
Parameter
Type
Value
Packaging Dimension (LxWxH)
tube
520.0 x 16.0 x 9.0mm
Packaging Quantity
42pcs
Storage Temperature Range
-55°C to +125°C
Storage Humidity
5% - 95%, RH
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 0/2018
ECO-4