Features
• 3kVDC/1s or 4kVDC/1s isolation
• Optional continuous short circuit protection
DC/DC Converter
• UL94V-0 package material
Unregulated
Converters
• Efficiency up to 84%
RK & RH
• Suitable for IGBT applications
1 Watt
SIP7
Single and Dual
Output
Description
The RK and RH Series DC/DC-Converter complements RECOM’s industrial range of converters with
very high isolations of 3kVDC/1s and 4kVDC/1s. The extended operating temperature range covering
–40°C to +90°C is a standard feature. The converters are IEC/EN/UL60950-1 certified, and are suitable
for IGBT driver applications.
Selection Guide
Part
Number
nom. Input
Output
Output
Efficiency
Max. Capacitive
Voltage Voltage Current typ. (1) Load (2)
[VDC] [VDC] [mA] [%] [µF]
RK-xx05S (3,4)
5, 12, 15, 24
5
200
70-78
1000
RK-xx09S (3,4)
5, 12, 15, 24
9
111
70-80
1000
5,12, 15, 24
12
84
78-82
470
RK-xx15S (3,4)
5, 12, 15, 24
15
66
80-82
470
RK-xx12S
(3,4)
5, 12, 15, 24
±5
±100
74-78
±470
RH-xx09D (3,4)
5, 12, 15, 24
±9
±56
76-79
±470
5, 12, 15, 24
±12
±42
78-84
±220
RH-xx15D (3,4)
5, 12, 15, 24
±15
±33
80-84
±220
5, 12, 24
+15/-9
+33/-56
70-81
+220/-470µF
RH-xx05D
RH-xx12D
(3,4)
(3,4)
RH-xx1509D
(3,4)
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Max Cap Load is tested at nominal input and full resistive load and is defined as the
capacitive load that will allow start up in under 1s without damage to the converter
Model Numbering
RK- __ __ S/
Protection (3)
Input Voltage
Isolation Option (4)
Output Voltage
E358085
UL60950-1 certified
CSA/CAN C22.2 No. 60950-1-07 certified
IEC/EN60950-1 certified
IEC/EN60601-1 certified*
EN55032 compliant
*+15/-9 version excluded
Single
RH- __ __ D/_
Input Voltage
Output Voltage
Protection (3)
Isolation Option (4)
Dual
Notes:
Note3: standard part is without Continuous Short Circuit Protection
add suffix „/P“ for Continuous Short Circuit Protection
Note4: add suffix „/H“ for 4kVDC/1s Isolation
or add suffix „/HP“ for Continuous Short Circuit Protection and 4kVDC/1s Isolation
Ordering Examples:
RH-123.3D/P: 12V Input Voltage, ±3.3V Output Voltage, Dual Output with continuous short circuit protection
RK-0509S/HP: 5V Input Voltage, 9V Output Voltage, Single Output with 4kVDC/1s Isolation and continuous short circuit protection
www.recom-power.com
REV.: 5/2019
ECO-1
RK & RH
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Max.
Internal Input Fuse
capacitors
Input Voltage Range
±10%
Minimum Load
0%
Start-up Time
250ms
Internal Operating Frequency
50kHz
Output Ripple and Noise
100kHz
105kHz
20MHz BW
100mVp-p
Efficiency vs. Load
RK-xx09S
100
100
90
90
80
80
70
70
Efficiency [%]
Efficiency [%]
RK-xx05S
60
50
40
30
40
20
3.305
0505
1205
10
0
10
20
30
40
50
60
70
80
90
0
100
0
10
20
30
40
50
60
Output Load [%]
Output Load [%]
RK-xx12S
RK-xx15S
100
100
90
90
80
80
70
70
60
50
40
30
70
80
90
100
60
50
40
30
20
20
3.312
0512
1212
10
0
3.309
0509
1209
10
Efficiency [%]
Efficiency [%]
50
30
20
0
60
0
10
20
30
40
50
60
70
80
90
10
100
Output Load [%]
www.recom-power.com
3.315
0515
1215
0
0
10
20
30
40
50
60
70
80
90
100
Output Load [%]
REV.: 5/2019
ECO-2
RK & RH
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Efficiency vs. Load
RH-xx09D
100
100
90
90
80
80
70
70
Efficiency [%]
Efficiency [%]
RH-xx05D
60
50
40
30
40
20
3.305
0505
1205
10
0
10
20
30
40
50
60
70
80
90
0
100
0
10
20
30
40
50
60
Output Load [%]
Output Load [%]
RH-xx12D
RH-xx15D
100
100
90
90
80
80
70
70
60
50
40
30
70
80
90
100
60
50
40
30
20
20
3.312
0512
1212
10
0
3.309
0509
1209
10
Efficiency [%]
Efficiency [%]
50
30
20
0
60
0
10
20
30
40
50
60
70
80
90
3.315
0515
1215
10
0
100
0
10
20
Output Load [%]
30
40
50
60
70
80
90
100
Output Load [%]
REGULATIONS
Parameter
Condition
Output Accuracy
Line Regulation
Load Regulation (5)
Values
±5.0% max.
low line to high line
5Vout
10% to 100% load
9, 12, 15Vout and RH-xx1509D
±1.2% of 1.0% Vin typ.
15.0% max.
10.0% max.
Notes:
Note5: Operation below 10% load will not harm the converter, but specifications may not be met
continued on next page
www.recom-power.com
REV.: 5/2019
ECO-3
RK & RH
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Deviation vs. Load
RK-xx05S
25
3.305
0505
1205
20
15
10
5
10
5
0
0
-5
-5
0
10
20
30
40
50
60
70
80
90
3.309
0509
1209
20
Deviation [%]
Deviation [%]
15
-10
RK-xx09S
25
-10
100
0
10
20
30
Output Load [%]
3.312
0512
1212
5
-5
-5
40
50
60
70
80
90
3.315
0515
1215
-10
100
0
10
20
30
Output Load [%]
3.305
0505
1205
5
-5
-5
40
50
60
90
100
70
80
90
3.309
0509
1209
5
0
30
80
10
0
20
70
15
10
10
60
20
Deviation [%]
Deviation [%]
15
0
50
RH-xx09D
25
20
-10
40
Output Load [%]
RH-xx05D
25
100
5
0
30
90
10
0
20
80
15
10
10
70
20
Deviation [%]
Deviation [%]
15
0
60
RK-xx15S
25
20
-10
50
Output Load [%]
RK-xx12S
25
40
100
-10
Output Load [%]
0
10
20
30
40
50
60
70
80
90
100
Output Load [%]
continued on next page
www.recom-power.com
REV.: 5/2019
ECO-4
RK & RH
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Deviation vs. Load
RH-xx12D
25
3.312
0512
1212
20
15
10
5
10
5
0
0
-5
-5
0
10
20
30
40
50
60
70
80
90
3.315
0515
1215
20
Deviation [%]
Deviation [%]
15
-10
RH-xx15D
25
-10
100
0
10
20
30
Output Load [%]
40
50
60
70
80
90
100
Output Load [%]
PROTECTIONS
Parameter
Condition
without suffix
with suffix “/P”
Short Circuit Protection (SCP)
Isolation Voltage (6)
1 second
continuous
without suffix
tested for 1 second
rated for 1 minute
3kVDC
1.5kVAC
with suffix “/H”
tested for 1 second
rated for 1 minute
4kVDC
2kVAC
I/P to O/P
Isolation Capacitance
Value
RK types
RH types
20pF min. / 75pF max.
20pF min. / 65pF max.
Isolation Resistance
15GΩ min.
basic (IEC/EN60950-1)
functional (IEC/EN60601-1)
Insulation Grade
Notes:
Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note7: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type
ENVIRONMENTAL
Parameter
Operating Temperature Range
Condition
Value
full load @ free air convection (see graph)
-40°C to +90°C
Operating Altitude
Operating Humidity
3000m
non-condensing
5% - 95% RH max.%
Pollution Degree
MTBF
PD2
RK type
+25°C
+85°C
992 x 10³ hours
145 x 10³ hours
RH type
+25°C
+85°C
1012 x 10³ hours
151 x 10³ hours
according to MIL-HDBK-217F; G.B.
continued on next page
www.recom-power.com
REV.: 5/2019
ECO-5
RK & RH
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Derating Graph
100
(@ free air convection)
90
Output Load [%]
80
70
60
50
40
30
20
10
0
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110
95
Ambient Temperature [°C]
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report / File Number
Standard
Information Technology Equipment, General Requirements for Safety
E358085-A4-UL
UL60950-1, 2nd Edition:2007
CAN/CSA C22.2 No. 60950-1-03, 2nd Edition:2007
Information Technology Equipment, General Requirements for Safety
SPCLVD1602031
IEC60950-1:2005, 2nd Edition + A2:2013
EN60950-1:2006 + A2:2013
Medical electrical equipment Part 1: General requirements for basic
safety and essential performance
WD-SE-R-180676-A0 (8)
IEC60601-1:2005 + A1:2012, 3rd Edition
EN60601-1:2006 + A1:2013 + A12:2014
EAC
RU-AT.49.09571
TP TC 004/2011
RoHS 2
RoHS-2011/65/EU + AM-2015/863
EMC Compliance
Condition
Electromagnetic compatibility of multimedia equipment Emission requirements
EMC Filter Suggestion according to EN55032
Single Output
Standard / Criterion
with external filter
(see filter suggestion below)
EN55032, Class B
EN55032, Class A
Notes:
Note8: excluded +15/-9 version
C3
L1
+Vin
C1
+Vin
+Vout
-Vin
-Vout
C2
-Vin
Component List Class A
MODEL
RK-0505S
RK-0515S
RK-2405S
C1
+Vout
-Vout
Component List Class B
L1
N/A
10µF
22µH choke RLS-226
100V MLCC
12µH choke RLS-126
C2
C3
MODEL
RK-0505S
N/A
N/A
RK-0515S
RK-2405S
C1
L1
10µF
12µH choke
100V MLCC RLS-126
C2
4.7µF
50V MLCC
C3
N/A
2.2nF
N/A
Notes:
Note9: Filter suggestions are valid for indicated part numbers only. For other part numbers, please contact RECOM tech support for advice
www.recom-power.com
REV.: 5/2019
ECO-6
RK & RH
DC/DC Converter
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
DIMENSION and PHYSICAL CHARACTERISTICS
Parameter
Type
Value
Material
case
potting
non-conductive black plastic, (UL94 V-0)
epoxy, (UL94 V-0)
Dimension (LxWxH)
standard
with suffix “/H”
19.65 x 6.0 x 10.2mm
19.65 x 7.05 x 10.2mm
Weight
standard
with suffix “/H”
2.6g typ.
2.8g typ.
Dimension Drawing (mm)
Standard Version
embossed logo
19.65
Pinning Information
10.2
6.0
Pin #
1
2
5
6
7
4.10
0.5
Marking
0.5+0.10/-0.05
0.25±0.05
2.00
5 6 7
1.27
Bottom View
1 2
Single
+Vin
-Vin
-Vout
no pin
+Vout
Dual
+Vin
-Vin
-Vout
Com
+Vout
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.25mm
2.54
Recommended Footprint
1 2
6x2.54= 15.24
5 6 7
Top View
2.54
„H“ - Version
embossed Logo
19.65
7.05
Pinning Information
4.10
0.5
10.2
Marking
0.5+0.10/-0.05
0.25±0.05
Pin #
1
2
5
6
7
Single
+Vin
-Vin
-Vout
no pin
+Vout
Dual
+Vin
-Vin
-Vout
Com
+Vout
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.25mm
2.54
Recommended Footprint
Bottom View
7
1 2
5 6 7
4 x 2.54 = 10.16
2.00
1 2
1.27
ew
5
Series
5 6 7
Top View
2.54
6 x 2.54 =15.24
www.recom-power.com
REV.: 5/2019
ECO-7
RK & RH
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
INSTALLATION AND APPLICATION
IGBT Application Circuit
+
Q1
C
Signal+
IC1
IN
Signal-
DC
-Vin
G
E
C2
DC
C1
-Vin
+Vin
R1
+Vout
IC2
+Vin
OUT
IGBT Driver
-Vout
C3
PACKAGING INFORMATION
Parameter
Type
Value
Packaging Dimension (LxWxH)
tube
520.0 x 16.0 x 9.0mm
Packaging Quantity
tube
25pcs
Storage Temperature Range
Storage Humidity
-55°C to +125°C
non-condensing
95% RH max.
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 5/2019
ECO-8