Features
Unregulated
Converters
• High 6.4kVDC/1s isolation
• Wide operating temperature range from
-40°C to +90°C without derating
• High capacitive load capability
• Continuous short circuit protection
• Efficiency up to 80%
DC/DC Converter
RK/H6 & RH/H6
Description
The RK/H6 and RH/H6 series 1W DC/DC converters feature high 6.4kVDC isolation and an extended
operating temperature range up to +90°C without derating, yet are lower cost than standard high
isolation converters. They are suitable for demanding industrial and high isolation test and measurement
applications.
Selection Guide
Part
Number
1 Watt
SIP7
Single and Dual
Output
nom. Input
Output
Output
Efficiency
Max. Capacitive
Voltage Range
Voltage
Current
typ.
Load (1)
[VDC] [VDC] [mA] [%] [µF]
RK-xx3.3S/H6
5, 12, 15, 24
3.3
303
71-74
1000
RK-xx05S/H6
5, 12, 15, 24
5
200
74-77
1000
RK-xx12S/H6
5, 12, 15, 24
12
84
77-79
220
RK-xx15S/H6
5, 12, 15, 24
15
66
77-80
220
RH-xx3.3D/H6
5, 12, 15, 24
±3.3
±152
73-74
±330
RH-xx05D/H6
5, 12, 15, 24
±5
±100
74-77
±330
RH-xx12D/H6
5, 12, 15, 24
±12
±42
77-80
±100
RH-xx15D/H6
5, 12, 15, 24
±15
±33
78-80
±100
Notes:
Note1: Max. capacitive load is tested at nominal input voltage and full load
Model Numbering
E224736
RK- __ __ S/H6
Input Voltage
6.4kVDC isolation
Single
Output Voltage
RH- __ __ D/H6
Input Voltage
Output Voltage
UL60950-1 certified
CAN/CSA C22.2 No. 60950-1-07 certified
UL62368-1 certified
CAN/CSA C22.2 No. 62368-1-14 certified
IEC/EN60950-1 certified
IEC/EN62368-1 certified
CB report
6.4kVDC isolation
Dual
Notes:
Note2: add suffix „K“ for Single output or suffix „H“ for Dual output
Ordering Examples:
RK-123.3S/H6 = 12VDC Input Voltage, 3.3VDC Output Voltage, Single Output, 6.4kVDC/1s isolation
RH-0505D/H6 = 5VDC Input Voltage, 5VDC Output Voltage, Dual Output, 6.4kVDC/1s isolation
www.recom-power.com
REV.: 5/2019
ECO-1
RK/H6 & RH/H6
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Max.
Internal Input Filter
capacitor
Input Voltage Range
±10%
Start-up Time
20ms
Internal Operating Frequency
80kHz
Minimum Load
Output Ripple and Noise
0%
20MHz BW
60mVp-p
120mVp-p
Efficiency vs. Load
Dual Output
100
100
90
90
80
80
70
70
Efficiency [%]
Efficiency [%]
Single Output
60
50
40
30
10
0
0
10
20
30
40
50
40
30
RK-123.3S/H6
RK-0505S/H6
RK-0512S/H6
RK-2415S/H6
20
60
RH-123.3D/H6
RH-0505D/H6
RH-1212D/H6
RH-0515D/H6
20
10
50
60
70
80
90
0
100
0
10
20
30
Output Load [%]
40
50
60
70
80
90
100
Output Load [%]
REGULATIONS
Parameter
Condition
Values
Output Accuracy
±5.0% max.
Line Regulation
Load Regulation
low line to high line, max. load
±1.2% of 1.0% Vin typ.
10% to 100% load
(3)
10% max.
Notes:
Note3: Operation below 10% load will not harm the converter, but specifications may not be met
Single Output
Dual Output
20
20
15
15
10
10
Deviation [%]
Deviation [%]
Deviation vs. Load
5
0
-5
RK-123.3S/H6
RK-0505S/H6
RK-0512S/H6
RK-2415S/H6
-10
-15
-20
0
10
20
30
40
50
60
70
80
90
0
-5
RH-123.3D/H6
RH-0505D/H6
RH-1212D/H6
RH-0515D/H6
-10
-15
100
Output Load [%]
www.recom-power.com
5
-20
0
10
20
30
40
50
60
70
80
90
100
Output Load [%]
REV.: 5/2019
ECO-2
RK/H6 & RH/H6
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
PROTECTIONS
Parameter
Condition
Value
Short Circuit Protection (SCP)
continuous
I/P to O/P
Isolation Voltage (4)
tested for 1 second
rated for 1 minute
6.4kVDC
5.2kVDC
Isolation Resistance
10GΩ min.
Isolation Capacitance
Insulation Grade
75pF max.
functional
Notes:
Note4: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note5: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type
ENVIRONMENTAL
Parameter
Condition
Operating Temperature Range
Value
without derating @ free air convection (see graph)
-40°C to +90°C
Operating Altitude
5000m
Operating Humidity
non-condensing
MTBF
according to MIL-HDBK-217F; G.B.
Derating Graph
5% - 95% RH max.
+25°C
+85°C
14919 x 10³ hours
9468 x 10³ hours
100
90
Output Load [%]
80
70
60
50
40
30
20
10
0
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110
95
Ambient Temperature [°C]
SAFETY AND CERTIFICATIONS
Certificate Type
Report / File Number
Information Technology Equipment - General Requirements for Safety
Audio/Video, information and communication technology equipment Part1: Safety requirements
Information Technology Equipment, General Requirements for Safety (CB)
Information Technology Equipment, General Requirements for Safety
Audio/video, information and communication technology equipment Part
1: safety requirements (CB)
Audio/video, information and communication technology equipment Part
1: safety requirements
E224736-A25-UL
E224736-A26-CB-1
Standard
UL60950-1, 2nd Edition, 2014
CAN/CSA-C22.2 No. 60950-1-07, 2nd Edtition, 2014
UL62368-1, 2nd Edition, 2014
CAN/CSA-C22.2 No. 62368-1-14, 2nd Edtition, 2014
IEC60950-1:2005, 2nd Edition + A2:2013
EN60950-1:2006 + A2:2013
IEC62368-1:2014, 2nd Edition
OFF-4787079973-A-2
EN62368-1:2014
continued on next page
www.recom-power.com
REV.: 5/2019
ECO-3
RK/H6 & RH/H6
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Certificate Type
Report / File Number
EAC
Standard
RU-AT.49.09571
TP TC 004/2011
RoHS 2
RoHS-2011/65/EU + AM-2015/863
EMI Compliance
Condition
Electromagnetic compatibility of multimedia equipment Emission requirements
Standard / Criterion
with external filter
(see filter suggestion below)
EN55032, Class B
EN55032, Class A
EMC Filter Suggestion according to EN55032
Single Output
C3
L1
+Vin
C1
+Vin
+Vout
-Vin
-Vout
C2
-Vin
Component List Class A
MODEL
RK-0505S/H6
RK-0515S/H6
RK-2405S/H6
C1
+Vout
-Vout
Component List Class B
L1
C2
10µF
12µH choke
100V MLCC RLS-126
Dual Output
C3
MODEL
C1
RK-0505S/H6
N/A
N/A
10µF
12µH choke
100V MLCC RLS-126
RK-0515S/H6
RK-2405S/H6
+Vin
-Vin
N/A
2.2nF
Com
-Vin
-Vout
Component List Class A
C1
-Vout
Component List Class B
L1
MODEL
RH-0505D/H6
RH-1212D/H6
4.7µF
50V MLCC
C3
+Vout
+Vout
C1
RH-1205D/H6
C2
L1
+Vin
MODEL
L1
C1
L1
4.7µF
50V MLCC
68µH choke
RLS-686
RH-0505D/H6
RH-1205D/H6
68µH choke
1µF
100V MLCC RLS-686
RH-1212D/H6
RH-2405D/H6
RH-2405D/H6
Notes:
Note6: Filter suggestions are valid for indicated part numbers only. For other part numbers, please contact RECOM tech support for advice
DIMENSION and PHYSICAL CHARACTERISTICS
Parameter
Type
Value
Material
case
potting
non-conductive black plastic, (UL94 V-0)
epoxy, (UL94 V-0)
Dimension (LxWxH)
19.65 x 7.05 x 10.2mm
Weight
2.7g typ.
continued on next page
www.recom-power.com
REV.: 5/2019
ECO-4
RK/H6 & RH/H6
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Dimension Drawing (mm)
embossed Logo
19.65
Pinning information
7.05
Pin #
1
2
5
6
7
4.10
0.5
10.2
Marking
0.5
0.25
+0.10/-0.05
±0.05
Single
+Vin
-Vin
-Vout
no pin
+Vout
Dual
+Vin
-Vin
-Vout
Com
+Vout
Tolerance:
xx.x= ±0.5mm
xx.xx= ±0.25mm
2.54
Recommended Footprint Details
Bottom View
7
1 2
5 6 7
4 x 2.54 = 10.16
2.00
1 2
1.27
ew
5 6 7
Top View
2.54
6 x 2.54 =15.24
PACKAGING INFORMATION
Parameter
Type
Value
Packaging Dimension (LxWxH)
tube
520.0 x 16.5 x 9.0mm
Packaging Quantity
tube
Storage Temperature Range
Storage Humidity
25pcs
-55°C to +125°C
non-condensing
95% RH max.
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 5/2019
ECO-5