Features
• High isolation 2W converter
• 3kVDC/1s and 4kVDC/1s basic isolation
• UL94V-0 package material
• Optional continuous short circuit protected
• Efficiency up to 84%
• Suitable for IGBT applications
Unregulated
Converters
DC/DC Converter
RKZ
Description
The RKZ Series of 2W DC/DC Converters are certified to EN60950-1. This makes them suitable for high
end industrial applications such as IGBT driver circuitry. The RKZ converters are pin-compatible with the
RK and RH converter series, offering a simple way to upgrade a 1W high isolation supply to 2W.
2 Watt
SIP7
Single and
Dual Output
Selection Guide
Part
Number
nom. Input
Output
Output
Efficiency max. Capacitive
Voltage Voltage Current typ. (1) Load (2)
[VDC] [VDC] [mA] [%]
[µF]
RKZ-xx05S (3,4)
5, 12, 24
5
400
82-84
1500
RKZ-xx12S (3,4)
5, 12, 24
12
168
82-87
330
5, 12, 24
15
132
82-84
330
RKZ-xx05D (3,4)
5, 12, 24
±5
±200
70-83
±680
RKZ-xx12D (3,4)
5, 12, 24
±12
±84
82-84
±220
RKZ-xx15D (3,4)
5, 12, 24
±15
±66
82-88
±220
RKZ-xx1509D
5, 12, 24
+15/-9
+67/-111
70-81
±330
RKZ-xx15S
(3,4)
(3,4)
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Max Cap Load is tested at nominal input and full resistive load and is defined as the
capacitive load that will allow start up in under 1s without damage to the converter
IEC/EN60950-1 certified
IEC/EN60601-1 certified
EN55032 compliant
Model Numbering
RKZ- __
nom. Input Voltage
Output Voltage
/
Protection (3)
Isolation Option (4)
Single or Dual
Notes:
Note3: standard part is without Continuous Short Circuit Protection
add suffix „/P“ for Continuous Short Circuit Protection
Note4: add suffix „/H“ for 4kVDC/1s Isolation
or add suffix „/HP“ for 4kVDC/1s Isolation and Continuous Short Circuit Protection
Ordering Examples:
RKZ-0515S/P: 5VDC Input Voltage, 15VDC Output Voltage, Single Output with continuous short circuit protection
RKZ-0515D/HP: 5VDC Input Voltage, ±15VDC Output Voltage, Dual Output with continuous short circuit protection and 4kVDC/1s isolation
www.recom-power.com/eval-ref-boards
www.recom-power.com
REV.: 5/2019
ECO-1
RKZ
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Max.
Internal Input Filter
capacitor
Input Voltage Range
±10%
Minimum Load
0%
all others
RKZ-xx1509D
Internal Operating Frequency
Output Ripple and Noise
20kHz
20kHz
50kHz
51kHz
85kHz
20MHz BW
150mVp-p
Efficiency vs. Load
RKZ-xx12S
100
100
90
90
80
80
70
70
Efficiency [%]
Efficiency [%]
RKZ-xx05S
60
50
40
30
50
40
30
0505
1205
2405
20
10
0
60
0
10
20
30
40
50
60
70
80
90
0512
1212
2412
20
10
0
100
0
10
20
30
Output Load [%]
60
70
80
90
100
RKZ-xx05D
100
100
90
90
80
80
70
70
Efficiency [%]
Efficiency [%]
50
Output Load [%]
RKZ-xx15S
60
50
40
30
60
50
40
30
0515
1215
2415
20
10
0
40
0
10
20
30
40
50
60
70
80
90
0505
1205
2405
20
10
100
0
Output Load [%]
0
10
20
30
40
50
60
70
80
90
100
Output Load [%]
continued on next page
www.recom-power.com
REV.: 5/2019
ECO-2
RKZ
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
RKZ-xx12D
RKZ-xx15D
100
100
90
90
80
80
70
70
Efficiency [%]
Efficiency [%]
Efficiency vs. Load
60
50
40
60
50
40
30
30
0512
1212
2412
20
10
0
0
10
20
30
40
50
60
70
80
90
0515
1215
2415
20
10
0
100
0
10
20
30
40
50
60
70
80
90
100
Output Load [%]
Output Load [%]
REGULATIONS
Parameter
Condition
Value
Output Accuracy
±5.0% max.
Line Regulation
low line to high line
10% to 100% load
Load Regulation (5)
±1.2% of 1.0% Vin typ.
5Vout
12, 15, 24Vout and RKZ-xx1509D
15.0% max.
10.0% max.
Notes:
Note5: Operation below 10% load will not harm the converter, but specifications may not be met
Deviation vs. Load
RKZ-xx05S
25
0505
1205
2405
20
15
Deviation [%]
Deviation [%]
0512
1212
2412
20
15
10
5
10
5
0
0
-5
-5
-10
RKZ-xx12S
25
0
10
20
30
40
50
60
70
80
90
100
-10
Output Load [%]
0
10
20
30
40
50
60
70
80
90
100
Output Load [%]
continued on next page
www.recom-power.com
REV.: 5/2019
ECO-3
RKZ
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Deviation vs. Load
RKZ-xx15S
RKZ-xx05D
25
25
0515
1215
2415
20
15
Deviation [%]
Deviation [%]
15
10
5
10
5
0
0
-5
-5
-10
0505
1205
2405
20
0
10
20
30
40
50
60
70
80
90
-10
100
0
10
20
30
Output Load [%]
0512
1212
2412
70
80
90
100
0515
1215
2415
20
15
Deviation [%]
15
Deviation [%]
60
RKZ-xx15D
25
20
10
5
10
5
0
0
-5
-5
-10
50
Output Load [%]
RKZ-xx12D
25
40
0
10
20
30
40
50
60
70
80
90
-10
100
0
10
20
Output Load [%]
30
40
50
60
70
80
90
100
Output Load [%]
PROTECTIONS
Parameter
Type
Short Circuit Protection (SCP)
Isolation Voltage (6)
Value
without suffix
with suffix “/P”
1 second
continuous
without suffix
tested for 1 second
rated for 1 minute
3kVDC
1.5kVAC / 60Hz
with suffix “/H”
tested for 1 second
rated for 1 minute
4kVDC
2kVAC / 60Hz
10GΩ min.
I/P to O/P
Isolation Resistance
Isolation Capacitance
120pF max.
basic (IEC/EN60950-1)
functional (IEC/EN60601-1)
Insulation Grade
Notes:
Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note7: Refer to local safety regulations if input over-current protection is required. Recommended fuse: slow blow type
www.recom-power.com
REV.: 5/2019
ECO-4
RKZ
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
ENVIRONMENTAL
Parameter
Condition
Operating Temperature Range
Value
full load @ free air convection (see graph)
Maximum Case Temperature
-40°C to +85°C
+110°C
Temperature Coefficient
±0.03%/K typ.
Thermal Impedance
40K/W typ.
Operating Altitude
3000m
Operating Humidity
non-condensing
95% RH max.
Pollution Degree
PD2
MTBF
according to MIL-HDBK-217F, G.B.
+25°C
+85°C
18300 x 10 hours
8070 x 103 hours
3
Derating Graph
(@ free air convection)
100
90
Output Load [%]
80
70
60
50
40
30
20
10
0
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110
85
Ambient Temperature [°C]
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report / File Number
Standard
Information Technology Equipment, General Requirements for Safety
SPCLVD1602031
IEC60950-1:2005, 2nd Edition + A2:2013
EN60950-1:2006 + A2:2013
Medical electrical equipment Part 1: General requirements for basic
safety and essential performance
WD-SE-R-180676-A0 (8)
IEC60601-1:2005 + A1:2012, 3rd Edition
EN60601-1:2006 + A1:2013 + A12:2014
EAC
RU-AT.49.09571
RoHS 2+
EMC Compliance
Electromagnetic compatibility of multimedia equipment Emission requirements
TP TC 004/2011
RoHS-2011/65/EU + AM-2015/863
Condition
with external filter
(see filter suggestion below)
Standard / Criterion
EN55032, Class B
EN55032, Class A
Notes:
Note8: excluded +15/-9 version
continued on next page
www.recom-power.com
REV.: 5/2019
ECO-5
RKZ
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
EMC Filter Suggestion according to EN55032
C2
L1
+Vin
+Vin
+Vout
-Vin
-Vout
+Vout
C1
-Vin
-Vout
C3
Component List Class A
MODEL
Component List Class B
C1
RKZ-0505S
L1
10µF
100V MLCC
RKZ-1205S
RKZ-2405S
N/A
C2 (safety) C3 (safety)
N/A
MODEL
C1
RKZ-0505S
N/A
RKZ-1205S
L1
12µH choke
RLS-126
10µF
100V MLCC 22µH choke
RLS-226
C2 (safety) C3 (safety)
470pF
1nF
RKZ-2405S
Notes:
Note9: Filter suggestions are valid for indicated part numbers only. For other part numbers, please contact RECOM tech support for advice
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter
Type
Value
Material
case
potting
PCB
non-conductive black plastic (UL94 V-0)
epoxy, (UL94 V-0)
FR4, (UL94 V-0)
Dimension (LxWxH)
19.65 x 7.05 x 10.2mm
Weight
2.8g typ.
Dimension Drawing (mm)
embossed Logo
19.65
Pinning information
7.05
Pin #
1
2
5
6
7
4.10
0.5
10.2
Marking
Single
+Vin
-Vin
-Vout
no pin
+Vout
Dual
+Vin
-Vin
-Vout
Com
+Vout
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.25mm
0.5+0.10/-0.05
0.25±0.05
2.54
Recommended Footprint Details
Bottom View
7
1 2
5 6 7
4 x 2.54 = 10.16
2.00
1 2
1.27
ew
5 6 7
Top View
2.54
6 x 2.54 =15.24
www.recom-power.com
REV.: 5/2019
ECO-6
RKZ
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
INSTALLATION AND APPLICATION
IGBT Application Circuit
+
Q1
C
Signal+
IC1
IN
Signal-
DC
-Vin
G
E
C2
DC
C1
-Vin
+Vin
R1
+Vout
IC2
+Vin
OUT
IGBT Driver
-Vout
C3
PACKAGING INFORMATION
Parameter
Type
Value
Packaging Dimension (LxWxH)
tube
520.0 x 16.0 x 9.0mm
Packaging Quantity
tube
Storage Temperature Range
Storage Humidity
25pcs
-55°C to +125°C
non-condensing
95% RH max.
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 5/2019
ECO-7