Features
Unregulated
Converters
• 1kVDC/1s or 2KVDC/1s basic isolation
• Optional continuous short circuit protected
• UL94V-0 package material
• No heatsink required
• Efficiency to 85%
DC/DC Converter
RN
Description
The RN series of compact 1.25W single output converters are especially useful when more than 1W of
power is required, but there are space restrictions than make a 2W converter unsuitable. The converter
series feature an industrial ambient temperature operating range of -40°C to +85°C without derating
and up to 100°C ambient temperature with derating. Options include 1kVDC or 2kVDC isolation and
continuous short circuit protection (/P).
1.25 Watt
DIP8
Single Output
Selection Guide
Part
Number
RN-xx3.3S
nom. Input
Voltage
[VDC]
3.3, 5, 9, 12, 15, 24
Output
Output
Efficiency max. Capacitive
Voltage Current typ. (1) Load (2)
[VDC] [mA] [%]
[µF]
3.3
378
70
2200
RN-xx05S
3.3, 5, 9, 12, 15, 24
5
250
70-72
1000
RN-xx07S
3.3, 5, 9, 12, 15, 24
7
180
72-75
1000
RN-xx09S
3.3, 5, 9, 12, 15, 24
9
140
75-80
1000
RN-xx12S
3.3, 5, 9, 12, 15, 24
12
104
79-82
470
RN-xx15S
3.3, 5, 9, 12, 15, 24
15
84
80-84
470
RN-xx24S
3.3, 5, 9, 12, 15, 24
24
52
80-85
220
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Max Cap Load is tested at nominal input and full resistive load and is defined as the
capacitive load that will allow start up in under 1s without damage to the converter
IEC/EN60950-1 certified
Model Numbering
RN- __
Input Voltage
Output Voltage
S/_
Protection (3)
Isolation Option (4)
Single
Notes:
Note3: standard part is without continuous short circuit protection
add suffix „/P“ for continuous short circuit protection
Note4: add suffix „/H“ for 2kVDC/1s isolation
or add suffix „/HP“ for continuous short circuit protection and 2kVDC/1s Isolation
Ordering Examples:
RN-0505S/P: 5V Input Voltage, 5V Output Voltage, Single Output with continuous short circuit protection
RN-0505S/HP: 5V Input Voltage, 5V Output Voltage, Single Output with 2kVDC/1s Isolation and continuous short circuit protection
www.recom-power.com
REV.: 1/2019
ECO-1
RN
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Input Voltage Range
Max.
±10%
Minimum Load
Internal Operating Frequency
0%
50kHz
Output Ripple and Noise
100kHz
105kHz
20MHz BW
75mVp-p
Efficiency vs. Load
RN-xx12S
100
100
90
90
80
80
70
70
Efficiency [%]
Efficiency [%]
RN-xx05S
60
50
40
60
50
40
30
30
20
20
0505
1205
10
0
0
10
20
30
40
50
60
70
80
90
0512
1212
10
0
100
0
10
20
Output Load [%]
30
40
50
60
70
80
90
100
Output Load [%]
RN-xx15S
100
90
Efficiency [%]
80
70
60
50
40
30
20
0515
1215
10
0
0
10
20
30
40
50
60
70
80
90
100
Output Load [%]
REGULATIONS
Parameter
Condition
Output Accuracy
Line Regulation
Load Regulation (5)
Value
±5.0% max.
low line to high line
10% to 100% load
3.3Vout
5Vout
9, 12, 15, 24Vout
±1.2% typ. / ±1.4% max.
20.0% max.
15.0% max.
10.0% max.
Notes:
Note5: Operation below 10% load will not harm the converter, but specifications may not be met
continued on next page
www.recom-power.com
REV.: 1/2019
ECO-2
RN
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Deviation vs. Load
RN-xx05S
25
0505
1205
20
15
Deviation [%]
Deviation [%]
0512
1212
20
15
10
5
10
5
0
0
-5
-5
-10
RN-xx12S
25
0
10
20
30
40
50
60
70
80
90
-10
100
0
10
20
30
Output Load [%]
40
50
60
70
80
90
100
Output Load [%]
RN-xx15S
25
0515
1215
20
Deviation [%]
15
10
5
0
-5
-10
0
10
20
30
40
50
60
70
80
90
100
Output Load [%]
PROTECTIONS
Parameter
Type
Short Circuit Protection (SCP)
Isolation Voltage (6)
Value
without suffix
with suffix “/P”
I/P to O/P
1 second
continuous
without suffix
tested for 1 second
rated for 1 minute
1kVDC
500VAC/60Hz
with suffix
“/H”
tested for 1 second
rated for 1 minute
2kVDC
1kVAC/60Hz
10GΩ min.
Isolation Resistance
Isolation Capacitance
30pF min. / 95pF max.
Insulation Grade
basic
Notes:
Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note7: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type
www.recom-power.com
REV.: 1/2019
ECO-3
RN
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
ENVIRONMENTAL
Parameter
Condition
Operating Temperature Range
Value
full load @ free air convection (see graph)
Operating Altitude
-40°C to +85°C
2000m
Operating Humidity
non-condensing
95% RH max.
Pollution Degree
PD2
MTBF
according to MIL-HDBK-217F, G.B.
+25°C
+85°C
955 x 103 hours
132 x 103 hours
Derating Graph
(@ free air convection)
100
90
Output Load [%]
80
70
60
50
40
30
20
10
0
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110
85
Ambient Temperature [°C]
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report / File Number
Information Technology Equipment, General Requirements for Safety
EAC
1602031
RU-AT.49.09571
RoHS 2+
Standard
IEC60950-1:2005, 2nd Edition + A2:2013
EN60950-1:2006 + A2:2013
TP TC 004/2011
RoHS-2011/65/EU + AM-2015/863
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter
Type
Value
Material
case
potting
PCB
non-conductive black plastic, (UL94 V-0)
epoxy, (UL94 V-0)
FR4, (UL94 V-0)
Dimension (LxWxH)
12.6 x 10.1 x 7.62mm
Weight
1.9g typ.
continued on next page
www.recom-power.com
REV.: 1/2019
ECO-4
RN
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Dimension Drawing (mm)
embossed logo
Pin #
1
4
5
7
Single
-Vin
+Vin
+Vout
-Vout
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.25mm
7.62
3.25
Ø0.5+0.10/0.05
Pinning Information
10.10
7.62
12.60
Recommended Footprint Details
1.00 Ø +0.15/-0
2.54
7.62
1
4
7
Bottom View
7
5.08
1
5
2.54
5
Top View
4
2.54
PACKAGING INFORMATION
Parameter
Type
Value
Packaging Dimension (LxWxH)
tube
520.0 x 15.0 x 16.0mm
Packaging Quantity
39pcs
Storage Temperature Range
Storage Humidity
-55°C to +125°C
non-condensing
95% RH max.
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 1/2019
ECO-5