RP-1505S/P/X2

RP-1505S/P/X2

  • 厂商:

    RECOM

  • 封装:

    SIP-7

  • 描述:

    CONV DC/DC 1W 15VIN 05VOUT

  • 数据手册
  • 价格&库存
RP-1505S/P/X2 数据手册
Features Unregulated Converters • Pot-core transformer - separated windings • high 5.2kVDC/1s basic isolation in compact size • Optional continuous short circuit protection • Efficiency up to 82% • Pin compatible with RH and RK series • Suitable for IGBT applications • IEC/EN/UL/CSA 60950-1 certified DC/DC Converter RP 1 Watt SIP7 Single and Dual Output Description The RP series has very high isolation of 5.2kVDC in a compact size. The converters are suitable for IGBT driver applications. The /X2 version has rearranged pins to permit an input output separation of more than 9mm. Selection Guide Part Number nom. Input Voltage [VDC] Output Output Efficiency max. Capacitive Voltage Current typ.(1) Load (2) [VDC] [mA] [%] [µF] RP-xx3.3S (3,4) 5, 9, 12, 15, 24 3.3 303 70 2200 5, 9, 12, 15, 24 5 200 70-72 1000 RP-xx09S (3,4) 5, 9, 12, 15, 24 9 111 75 1000 RP-xx05S (3,4) 5, 9, 12, 15, 24 12 84 75-78 470 RP-xx15S (3,4) 5, 9, 12, 15, 24 15 66 80 470 (3,4) 5, 9, 12, 15, 24 24 42 80 220 RP-xx3.3D (3) 5, 9, 12, 15, 24 ±3.3 ±152 70 ±1000 RP-xx05D (3) 5, 9, 12, 15, 24 ±5 ±100 74-76 ±470 RP-xx09D (3) 5, 9, 12, 15, 24 ±9 ±56 75 ±470 RP-xx12S RP-xx24S (3,4) RP-xx12D 5, 9, 12, 15, 24 ±12 ±42 79-82 ±220 RP-xx15D (3) 5, 9, 12, 15, 24 ±15 ±33 80-82 ±220 RP-xx24D 5, 9, 12, 15, 24 ±24 ±21 80 ±100 (3) (3) E358085 RP-xx1509D 5,12,24 +15/-9 ±42 70-85 ±220 Notes: Note1: Efficiency is tested at nominal input and full load at +25°C ambient Note2: Max Cap Load is tested at nominal input and full resistive load UL60950-1 certified* CSA/CAN C22.2 No. 60950-1-07 certified* IEC/EN60950-1 certified IEC/EN60601-1 certified* EN55032 compliant Model Numbering RP- __ __ /_ nom. Input Voltage Output Voltage Protection (3) alternative Pinning Option (4) *+15/-9 version excluded Single or Dual Notes: Note3: standard part is without continuous short circuit protection add suffix „/P“ for continuous short circuit protection Note4: add suffix „/X2“ for alternative pinning (only available for single outputs) or add suffix „/P/X2“ for continuous short circuit protection and alternative pinning Ordering Examples: RP-123.3S/P: 12V Input Voltage, 3.3V Output Voltage, Single Output with continuous short circuit protection RP-0509S/X2: 5V Input Voltage, ±9V Output Voltage, Single Output with alternative pinning RP-0505S/P/X2: 5V Input Voltage, 5V Output Voltage, Single Output with continuous short circuit protection and alternative pinning www.recom-power.com REV.: 6/2019 ECO-1 RP DC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin and full load unless otherwise stated) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Max. Internal Input Filter capacitor Input Voltage Range ±10% Minimum Load 0% 250ms Start-up time Internal Operating Frequency 50kHz Output Ripple and Noise 100kHz 120kHz 20MHz BW 100mVp-p Efficiency vs. Load RP-xx12S 100 100 90 90 80 80 70 70 Efficiency [%] Efficiency [%] RP-xx05S 60 50 40 30 40 20 0505 1205 10 0 10 20 30 40 50 60 70 80 90 0 100 0 10 20 30 40 50 60 Output Load [%] Output Load [%] RP-xx15S RP-xx05D 100 100 90 90 80 80 70 70 60 50 40 30 70 80 90 100 60 50 40 30 20 20 0515 1215 10 0 0512 1212 10 Efficiency [%] Efficiency [%] 50 30 20 0 60 0 10 20 30 40 50 60 70 80 90 0505 1205 10 100 0 Output Load [%] 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] continued on next page www.recom-power.com REV.: 6/2019 ECO-2 RP DC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin and full load unless otherwise stated) Efficiency vs. Load RP-xx15D 100 100 90 90 80 80 70 70 Efficiency [%] Efficiency [%] RP-xx12D 60 50 40 30 50 40 30 20 20 0512 1212 10 0 60 0 10 20 30 40 50 60 70 80 0515 1215 10 90 0 100 0 10 20 30 Output Load [%] 40 50 60 70 80 90 100 Output Load [%] REGULATIONS Parameter Condition Value Output Accuracy ±5.0% max. Line Regulation low line to high line 10% to 100% load Load Regulation (5) ±1.2% of 1.0% Vin typ. 20.0% max. 15.0% max. 10.0% max. 3.3Vout 5Vout 9, 12, 15, 24Vout and RP-xx1509D Notes: Note5: Operation below 10% load will not harm the converter, but specifications may not be met Deviation vs. Load RP-xx05S 25 0505 1205 20 15 Deviation [%] Deviation [%] 0512 1212 20 15 10 5 10 5 0 0 -5 -5 -10 RP-xx12S 25 0 10 20 30 40 50 60 70 80 90 100 -10 Output Load [%] 0 10 20 30 40 50 60 70 80 90 100 Output Load [%] continued on next page www.recom-power.com REV.: 6/2019 ECO-3 RP DC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin and full load unless otherwise stated) Deviation vs. Load RP-xx15S 25 0515 1215 20 15 Deviation [%] Deviation [%] 0505 1205 20 15 10 5 10 5 0 0 -5 -5 -10 RP-xx05D 25 0 10 20 30 40 50 60 70 80 90 -10 100 0 10 20 30 Output Load [%] 0512 1212 70 80 90 100 0515 1215 20 15 Deviation [%] 15 Deviation [%] 60 RP-xx15D 25 20 10 5 10 5 0 0 -5 -5 -10 50 Output Load [%] RP-xx12D 25 40 0 10 20 30 40 50 60 70 80 90 -10 100 0 10 20 Output Load [%] 30 40 50 60 70 80 90 100 Output Load [%] PROTECTIONS Parameter Type Short Circuit Protection (SCP) Isolation Voltage (6) Value without suffix with suffix “/P” I/P to O/P 1 second continuous tested for 1 second rated for 1 minute 5.2kVDC 2kVAC/60Hz 20GΩ min. Isolation Resistance Isolation Capacitance 4pF min. / 10pF max. basic (IEC/EN60950-1) functional (IEC/EN60601-1) Insulation Grade Notes: Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage Note7: Refer to local wiring regulations if input over-current protection is also required. Recommended fuse: T1A slow blow type www.recom-power.com REV.: 6/2019 ECO-4 RP DC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin and full load unless otherwise stated) ENVIRONMENTAL Parameter Condition Operating Temperature Range Value full load (see graph) -40°C to +85°C Maximum Case Temperature +105°C Operating Altitude 3000m Operating Humidity non-condensing 95% RH max. Pollution Degree PD2 MTBF according to MIL-HDBK-217F, G.B. 18400 x 10 hours 6900 x 103 hours +25°C +85°C 3 Derating Graph 100 90 Output Load [%] 80 70 60 50 40 30 20 10 0 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 85 Ambient Temperature [°C] SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Standard Information Technology Equipment, General Requirements for Safety E358085-A6-UL (8, 9) UL60950-1, 2nd Edition:2007 CAN/CSA C22.2 No. 60950-1-03, 2nd Edition:2007 Information Technology Equipment, General Requirements for Safety SPCLVD1602031 (9) IEC60950-1:2005, 2nd Edition + A2:2013 EN60950-1:2006 + A2:2013 Medical electrical equipment Part 1: General requirements for basic safety and essential performance WD-SE-R-180676-A0 (8) IEC60601-1:2005 + A1:2012, 3rd Edition EN60601-1:2006 + A1:2013 + A12:2014 EAC RU-AT.49.09571 RoHS 2+ EMC Compliance Electromagnetic compatibility of multimedia equipment Emission requirements TP TC 004/2011 RoHS-2011/65/EU + AM-2015/863 Condition with external filter (see filter suggestion below) Standard / Criterion EN55032, Class B EN55032, Class A Notes: Note8: excluded +15/-9 version Note9: excluded suffix „/X2“ continued on next page www.recom-power.com REV.: 6/2019 ECO-5 RP DC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin and full load unless otherwise stated) EMC Filter Suggestion according to EN55032 L1 +Vin C1 +Vin +Vout -Vin -Vout +Vout C2 C3 -Vin -Vout C4 Component List Class A MODEL Component List Class B C2 C3 MODEL RP-0505S C1 L1 C4 (safety) RP-0505S RP-0515S 10µF 100V MLCC RP-2405S RP-0515S 4.7µF 50V MLCC RP-2405S RP-2424S 10µF 22µH choke 100V MLCC RLS-226 2.2nF RP-2424S Notes: Note10: Filter suggestions are valid for indicated part numbers only. For other part numbers, please contact RECOM tech support for advice DIMENSION AND PHYSICAL CHARACTERISTICS Parameter Type Value Material case potting PCB non-conductive black plastic (UL94 V-0) epoxy, (UL94 V-0) FR4, (UL94 V-0) Dimension (LxWxH) 19.65 x 7.05 x 10.2mm Weight 2.4g typ. Dimension Drawing (mm) embossed Logo 19.65 Pinning information 7.05 Pin # 1 2 5 6 7 4.10 0.5 10.2 Marking Single +Vin -Vin -Vout no pin +Vout Dual +Vin -Vin -Vout Com +Vout /X2 +Vin -Vin no PIn -Vout +Vout Tolerance: xx.x= ±0.5mm xx.xx= ±0.25mm 0.5+0.10/-0.05 0.25±0.05 2.54 Recommended Footprint Details Bottom View 7 1 2 5 6 7 4 x 2.54 = 10.16 2.00 1 2 1.27 ew 5 6 7 Top View 2.54 6 x 2.54 =15.24 www.recom-power.com REV.: 6/2019 ECO-6 RP DC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin and full load unless otherwise stated) INSTALLATION AND APPLICATION IGBT Application Circuit + Q1 C Signal+ IC1 IN Signal- DC -Vin G E C2 DC C1 -Vin +Vin R1 +Vout IC2 +Vin OUT IGBT Driver -Vout C3 PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) tube 520.0 x 16.0 x 9.0mm Packaging Quantity tube Storage Temperature Range Storage Humidity 25pcs -55°C to + 125°C non-condensing 95% RH max. The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV.: 6/2019 ECO-7
RP-1505S/P/X2 价格&库存

很抱歉,暂时无法提供与“RP-1505S/P/X2”相匹配的价格&库存,您可以联系我们找货

免费人工找货