Features
•
•
•
•
•
•
Regulated
Converter
2:1 input voltage range
1.6kVDC isolation
UL60950-1 certified
Efficiency up to 87%
Fixed operation frequency
Six-sided continuous shield
DC/DC Converter
RP10-E
Description
10 Watt
3
2“ x 1“
Single and Dual
Output
YEA R
T
CONVER
y
T
REACH
M
TS
TS
compliant
CO
C
M
S
S
10 from 10
PL
U
D
IA N
T PRO
O
R
R
M
C
C
CONVER
RE
M
E
O
E
C
RoHS 2 +
compliant
CO
Part Number
Input
Output
Output
Input (1) Efficiency (1) Max. Capacitive
Voltage Range Voltage
Current
Current
typ.
Load (2)
[VDC] [VDC] [mA] [mA] [%]
[µF]
RP10-123.3SE (3,4) 9-18 3.3 2000 688 80
6800
RP10-1205SE (3,4)
9-18
5
2000
1029
81
4700
RP10-1212SE (3,4) 9-18 12 830 988 84
690
RP10-1215SE (3,4) 9-18 15 670 997 84
470
RP10-243.3SE (3,4)
18-36
3.3
2000
344
80
6800
RP10-2405SE (3,4) 18-36 5 2000 508 82
4700
RP10-2412SE (3,4)
18-36
12
830
494
84
690
RP10-2415SE (3,4) 18-36 15 670 499 84
470
RP10-483.3SE (3,4) 36-75 3.3 2000 172 80
6800
RP10-4805SE (3,4)
36-75
5
2000
248
84
4700
RP10-4812SE (3,4) 36-75 12 830 241 86
690
RP10-4815SE (3,4) 36-75 15 670 241 87
470
RP10-1205DE (3,4)
9-18
±5
±1000
992
84
±680
RP10-1212DE (3,4) 9-18 ±12 ±416 1002 83
±330
RP10-1215DE (3,4) 9-18 ±15 ±333 991 84
±110
RP10-2405DE (3,4) 18-36 ±5 ±1000 502 83
±680
RP10-2412DE (3,4)
18-36
±12
±416
489
85
±330
RP10-2415DE (3,4)
18-36
±15
±333
496
84
±110
RP10-4805DE (3,4) 36-75 ±5 ±1000 248 84
±680
RP10-4812DE (3,4)
36-75
±12
±416
242
86
±330
RP10-4815DE (3,4) 36-75 ±15 ±333 245 85
±110
RE
Selection Guide
arrant
w
The RP10-E series DC/DC converters are certified to UL 60950-1 and cUL 60950-1. This makes them
ideal for all telecom and industrial applications where approved safety standards are required. The
industry standard 2” x 1” package meets military standards for thermal shock and vibration tolerance
and is available with an optional remote on/off control pin. This series is also available with the /M1 and
/M2 option which is particularly suitable for extended temperature range applications.
PL
U
D
IA N
T PRO
E196683
UL60950-1 certified
EN55032 compliant
Notes:
Note1: Maximum values at nominal input voltage and full load
Note2: Max. Cap load is tested at minimum input and constant resistive load
Model Numbering
RP10-__ __ _E/_/M1nom. Input Voltage
nom. Output Voltage
Single or Dual
Notes:
Note3:
Note4:
Note5:
“Package (5)”
“Extended Version (4)”
“CTRL Logic (3)”
no suffix for standard part without CTRL pin
add suffix “P” for CTRL function with positive logic (1=ON, 0=OFF)
add suffix “N” for CTRL function with negative logic (0=ON, 1=OFF)
add suffix “/M1” for higher efficiencies and extended temperature range
add suffix “-HC” for premounted Heat-sink with clips
Ordering Examples
RP10-1205SE/P = 12V input, 5V output, single, positive logic CTRL pin
RP10-4805DE/M1-HC = 48V input, ±5V output‚ dual, extended temp. range, Heat-sink premounted
www.recom-power.com
REV.: 4/2020
PD-1
RP10-E
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
nom. Vin = 12VDC
nom. Vin = 24VDC
nom. Vin = 48VDC
9VDC
18VDC
36VDC
12VDC
24VDC
48VDC
Max.
Internal Input Filter
Input Voltage Range
Input Surge Voltage
Pi-Type
18VDC
36VDC
75VDC
36VDC
50VDC
100VDC
nom. Vin = 12VDC
nom. Vin = 24VDC
nom. Vin = 48VDC
100ms max.
Minimum Load (6)
10%
Start-up Time
Power up
20ms
Positive Logic
DC-DC ON
DC-DC OFF
Negative Logic
DC-DC ON
DC-DC OFF
Input Current of CTRL pin
drive current
ICTRL
Standby Current
DC-DC OFF
IIn
20MHz BW
Single
Dual
ON/OFF CTRL
refer to “ON/OFF CTRL”
(7)
Open or 3.5VDC < VCTRL< 12VDC
Short or 0VDC < VCTRL< 1.2VDC
Short or 0VDC < VCTRL< 1.2VDC
Open or 3.5VDC < VCTRL< 12VDC
-0.5mA
+1.0mA
20mA
Internal Operating Frequency
270kHz
Output Ripple and Noise
300kHz
Input Reflected Ripple Current (8)
Notes:
Note6:
Note7:
Note8:
330kHz
50mVp-p
75mVp-p
30mAp-p
The RP10-E series requires a minimum of 10% loading on the output to maintain specified regulation. Operation
under no-load condition will not damage these devices, however they may not meet all listed specification
If no suffix is specified, the control pin will be absent. If fitted, the ON/OFF control function can be positive or negative logic.
The pin voltage is referenced to -Vin
Simulated source impedance of 12μH. 12μH inductor in series with +Vin
RP10-1205SE
Efficiency vs. Input Voltage full load
Efficiency vs. Output Current
95
85
90
80
80
Efficiency [%]
Efficiency [%]
85
75
70
65
60
55
9Vin
12Vin
18Vin
50
45
40
75
70
65
60
55
10
20
30
40
50
60
70
80
90
100
9
10
11
12
13
14
15
16
17
18
Input Voltage [VDC]
Output Current [%]
continued on next page
www.recom-power.com
REV.: 4/2020
PD-2
RP10-E
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
RP10-2405SE
Efficiency vs. Output Current
95
Efficiency vs. Input Voltage full load
90
90
85
80
80
Efficiency [%]
Efficiency [%]
85
75
70
65
60
55
75
70
18Vin
24Vin
36Vin
50
45
65
40
10
20
30
40
50
60
70
80
90
60
100
18
20
22
Output Current [%]
24
26
28
30
32
34
36
Input Voltage [VDC]
RP10-4805SE
Efficiency vs. Output Current
Efficiency vs. Input Voltage full load
86
95
90
84
80
75
70
65
60
55
80
78
36Vin
48Vin
75Vin
50
45
40
10
82
Efficiency [%]
Efficiency [%]
85
76
74
20
30
40
50
60
70
80
90
100
36
40
44
48
52
56
60
66
72
75
Input Voltage [VDC]
Output Current [%]
ON/OFF CTRL
+Vin
VCTRL
IIN
ICTRL
-Vin
+Vin
+Vout
+Vout
Positve Logic
DC-DC ON
DC-DC OFF
Open or 3.5VDC < VCTRL < 15VDC
Short or 0VDC < VCTRL < 1.2VDC
Negativ Logic
DC-DC ON
DC-DC OFF
Short or 0VDC < VCTRL < 1.2VDC
Open or 3.5VDC < VCTRL < 15VDC
CTRL
-Vin
-Vout
-Vout
REGULATIONS
Parameter
Condition
Value
Output Accuracy
Line Regulation
Load Regulation
Cross Regulation
Transient Response Recovery Time
www.recom-power.com
±1.0%
low line to high line, full load
±0.2%
Single
Dual
±0.5%
±1.0%
asymmetrical 25%100% load
±5.0%
0% to 100% load
25% load step change
REV.: 4/2020
250μs typ.
PD-3
RP10-E
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
PROTECTIONS
Parameter
Condition
Value
Short Circuit Protection (SCP)
continuous, automatic recovery
Over Voltage Protection (OVP)
zener diode clamp
Over Load Protection (OLP)
3.9VDC typ.
6.2VDC typ.
15VDC typ.
18VDC typ.
3.3Vout
5Vout
12Vout
15Vout
% of Iout rated
150% typ.
continued on next page
PROTECTIONS
Parameter
Condition
Value
Isolation Voltage (9)
I/P to O/P
I/P to O/P to case
Isolation Resistance
Viso= 500VDC
1.6kVDC/ 1 minute
1.6kVDC/ 1 minute
1GΩ min.
Isolation Capacitance
300pF max.
Notes:
Note9: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note10: This power module is not internally fused. An input line fuse must always be used
ENVIRONMENTAL
Parameter
Condition
Operating Temperature Range
with derating
Value
Standard
with suffix “M1”
-25°C to +100°C
-40°C to +100°C
Maximum Case Temperature
+105°C
Temperature Coefficient
±0.02%/K max.
@ natural convection 0.1m/s,
vertical direction
Thermal Impedance
Operating Humidity
without heat-sink
with heat-sink
12K/W
10K/W
non-condensing
5% - 95% RH
Thermal Shock
according to MIL-STD-810F
Vibration
according to MIL-STD-810F
MTBF
MIL-HDBK-217F, G.B.
Derating Graph (11)
3342 x 103 hours
RP10-4805SE-HC
100
80
80
Output Power [%]
Output Power [%]
RP10-4805SE
100
60
40
20
0
-25
-20
0
20
40
60
80
77
60
40
20
0
100
-25
Ambient Temperature [°C]
-20
0
20
40
60
80
81
100
Ambient Temperature [°C]
continued on next page
www.recom-power.com
REV.: 4/2020
PD-4
RP10-E
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
RP10-4805SE/M1-HC (12)
100
100
80
80
Output Power [%]
Output Power [%]
RP10-4805SE/M1 (12)
60
40
20
0
-40
-20
0
20
40
60
60
40
20
0
-40
80 100
85
Ambient Temperature [°C]
-20
0
20
40
60
80 100
88
Ambient Temperature [°C]
Notes:
Note11: Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-number
not shown here please contact RECOM Techsupport for detailed information
Note12: “/M1” version is more efficient and can therefore operate in a more extensive temperature range than standard version
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Condition
Information Technology Equipment, General Requirements for Safety
E196683
EAC
Standard
UL60950-1, 2nd Edition, 2011
CAN/CSA-C22.2 No. 60950-1-07, 2nd Edition, 2011
RU-AT.49.09571
RoHS2+
TP TC 004/2011
RoHS-2011/65/EU + AM-2015/863
EMC Compliance
Condition
Standard / Criterion
Electromagnetic compatibility of multimedia equipment - Emission
requirements
with external filter
(see filter suggestion below)
EN55032, Class A and B
ESD Electrostatic discharge immunity test
Air ±8kV and Contact ±6kV
EN61000-4-2, Criteria B
10 V/m
EN61000-4-3, Criteria A
±2kV
EN61000-4-4, Criteria B
±2kV
EN61000-4-5, Criteria B
10 Vr.m.s
EN61000-4-6, Criteria A
100A/m continuous; 1000A/m 1s
EN61000-4-8, Criteria A
Radiated, radio-frequency, electromagnetic field immunity test
Fast Transient and Burst Immunity
(13)
Surge Immunity (13)
Immunity to conducted disturbances, induced by radio-frequency fields
Power Magnetic Field Immunity
Notes:
Note13: An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5
Recom suggests Nippon chemi-con KY series 220μF/100V
continued on next page
www.recom-power.com
REV.: 4/2020
PD-5
RP10-E
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
EMC Filtering Suggestions according to EN55032
Single
C2
F1
+Vin
+Vin
C2
+Vout
+Vout
F1
+Vin
+Vin
C1
F1
+Vin
C2
-Vout
C
+Vin3
-Vout
F1
+Vin
-Vin
-Vout
C2
-Vout
C3
-Vin
-Vin
-Vout
1000pF/2kV, 1808 MLCC
1000pF/2kV,
1808 MLCC
C3
3
RP10-24xxSE, RP10-24xxDE
N/A
1000pF/2kV, 1808 MLCC
3
1000pF/2kV,
1808 MLCC
L1
C2
L1
F1
+Vout
N/A
+Vout
+Vin
1000pF/2kV, 1808 MLCC+V
in
C1
C3
C
+Vin4
C1
-Vout
-Vout
+Vout
+Vout
1000pF/2kV, 1808
MLCC
+V
C3
-Vin
L1
F1
+Vin
C
+Vin4
C2
C1
Com
Dual
Com
-Vout
-Vout
+Vout
C2
Com
-Vin
-Vin
-Vout
-Vout
-Vin
-Vin
C4
Component List Class B
MODEL
RP10-12xxSE
RP10-12xxDE
RP10-24xxSE
RP10-24xxDE
RP10-48xxSE
RP10-48xxDE
C1
3.3μF/50V
1812 MLCC
2.2μF/50V
1812 MLCC
2.2μF/100V
1812 MLCC
+Vout
out
C2
-Vin
-Vout
C
L1
F1
Single
-Vin
+Vin
C1
2.2μF/25V, 1206 MLCC
C1
Com
Com
in
RP10-48xxSE,
RP10-48xxDE
+V
+Vout
+Vout
RP10-12xxSE, RP10-12xxDE
C3
in
-Vin
C
-Vout
C1
C
+Vin
-Vout
+Vin3
C1
Com
Com
C2
-Vin
-Vin
+Vout
+Vout
Component List Class A
MODEL
-V
F1
+Vout
+Vout
C1
-Vin
-Vin
Dual
-Vout
+Vout
Com
-Vout
C4
C2
N/A
N/A
2.2μF/100V
1812 MLCC
C3/C4
L1
1000pF/2kV
1808 MLCC
1000pF/2kV
1808 MLCC
CMC: 325μH
ref: WE 744290321 ref.: CMC-06
CMC: 325μH
ref: WE 744290321 ref.: CMC-06
1000pF/2kV
1808 MLCC
CMC: 325μH
ref: WE 744290321 ref.: CMC-06
DIMENSIONS AND PHYSICAL CHARACTERISTICS
Parameter
Material
Dimensions (LxWxH)
Weight
Type
Value
case
base
potting
without Heat-sink
with Heat-sink
nickel coated copper
non-conductive black plastic
epoxy (UL94 V-0)
50.8 x 25.4 x 10.2mm
56.8 x 25.4 x 16.8mm
without Heat-sink
with Heat-sink
27g
37.89g
continued on next page
www.recom-power.com
REV.: 4/2020
PD-6
RP10-E
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Dimension Drawing (mm)
Pinning Information
5.6
25.4
10.2
50.8
Pin #
1
2
3
4
5
6
15.20
8 x 2.54= 20.32
Bottom View
12.70
2
6
7.62
1
2.54
2
4
2.54
5
6
2.54
10.2
5.08
Recommended Footprint Details
1
Dual
+Vin
-Vin
+Vout
Com
-Vout
CTRL (3)
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.25mm
Ø 1.0±0.1
3
Single
+Vin
-Vin
+Vout
no Pin
-Vout
CTRL (3)
Top View
4
3
5
Dimension Drawing with Heat-sink (mm)
50.8
24.2
10.2
16.8
5.85
56.8
5.6
25.4
Top View
Heat-sink
15.20
8 x 2.54= 20.32
Ø 1.0±0.1
2.54
5.08
1
Bottom View
12.70
Packaging Dimension (LxWxH)
2
4
6
5
5
6
Type
tube
tray
tube
tray
2
1
2.54
10.2
3
Parameter
Packaging Quantity
7.62
2.54
PACKAGING INFORMATION
without4
Top View
255.0 x 54.0 x 22.0mm
302.5 x 222.0 x 20.0mm
without3 heat-sink
with heat-sink
9pcs
20pcs
Storage Temperature Range
Storage Humidity
Value
heat-sink
with heat-sink
-55°C to +125°C
non-condensing
5% - 95% RH
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 4/2020
PD-7