Features
•
•
•
•
•
•
Regulated
Converter
4:1 wide input voltage range
1.6kVDC isolation
UL60950-1 certified
Efficiency up to 91%
Six-sided continuous shield
No minimum load required
Description
DC/DC Converter
RP10-AW
10 Watt
3
1“ x 1“
Single and Dual
Output
YEA R
y
arrant
w
The RP10-AW series are wide input voltage range 1”x1” power DC/DC converters. Despite their
small size, the RP10-AW converters are fully specified devices with built-in Class A EMC filters, no
minimum load, 1600VDC isolation, under-voltage lockout and low ripple/noise figures. The outputs are
fully protected against short circuits, overcurrent and overvoltage and can be trimmed over a +/-10%
range. The RP10-AW series will find many uses in applications where board space is at a premium as
no external components are required.
T
CONVER
T
REACH
M
TS
TS
compliant
CO
C
M
S
S
10 from 10
PL
U
D
IA N
T PRO
O
R
R
M
C
C
CONVER
RE
M
E
O
E
C
RoHS 2 +
compliant
CO
Part Number
Input
Output
Output
Input (1) Efficiency (1) Max. Capacitive
Voltage Range Voltage
Current
Current
typ.
Load (2)
[VDC] [VDC] [mA] [mA] [%]
[µF]
RP10-243.3SAW (2,3) 9-36 3.3 3000 485 85
3500
RP10-2405SAW (2,3) 9-36 5 2000 479 87
2500
RP10-2412SAW (2,3)
9-36
12
830
461
90
430
RP10-2415SAW (2,3) 9-36 15 670 460 91
350
RP10-2424SAW (2,3) 9-36 24 416 462 90
125
RP10-483.3SAW (2,3) 18-75 3.3 3000 243 85
3500
RP10-4805SAW (2,3) 18-75 5 2000 239 87
2500
RP10-4812SAW (2,3) 18-75 12 830 231 90
430
RP10-4815SAW (2,3) 18-75 15 670 233 90
350
RP10-4824SAW (2,3) 18-75 24 416 231 90
125
RP10-2405DAW (2,3) 9-36 ±5 ±1000 479 87
±1440
RP10-2412DAW (2,3) 9-36 ±12 ±416 467 89
±250
RP10-2415DAW (2,3) 9-36 ±15 ±333 468 89
±180
RP10-4805DAW (2,3)
18-75
±5
±1000
239
87
±1440
RP10-4812DAW (2,3) 18-75 ±12 ±416 234 89
±250
RP10-4815DAW (2,3) 18-75 ±15 ±333 234 89
±180
RE
Selection Guide
PL
U
D
IA N
T PRO
E196683
UL60950-1 certified
EN55032 compliant
Notes:
Note1: Maximum values at nominal input voltage and full load
Note2: Max. Cap load is tested at nominal input and full resistive load
Model Numbering
RP10-__ __ _AW/_-_
nom. Input Voltage
nom. Output Voltage
“Package (4)”
“CTRL Logic (3)”
Single or Dual
Notes:
Note3:
Note4:
add suffix ”P” for CTRL function with positive logic (1=ON, 0=OFF) and Trim pin
add suffix “N” for CTRL function with negative logic (0=ON, 1=OFF) and Trim pin
or add suffix “XC” for omitted CTRL pin and Trim pin (refer to “Dimension Drawing”)
add suffix “-HC” for premounted Heat-sink with clamps
Ordering Examples
RP10-1205SAW/P = 12V input, 5V output, single, positive Logic CTRL pin
RP10-4805DAW/XC-HC = 48V input, ±5V output, dual, without CTRL pin, Heat-sink premounted
www.recom-power.com
REV.: 7/2020
PD-1
RP10-AW
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Max.
nom. Vin = 24VDC
nom. Vin = 48VDC
9VDC
18VDC
24VDC
48VDC
36VDC
75VDC
Internal Input Filter
Pi-Type
Input Voltage Range
1s max.
nom. Vin = 24VDC
nom. Vin = 48VDC
nom. Vin = 24VDC
DC-DC ON
DC-DC OFF
8VDC
nom. Vin = 48VDC
DC-DC ON
DC-DC OFF
16VDC
refer to
“OUTPUT VOLTAGE TRIMMING”
3.3Vout, 12Vout
Others
Input Surge Voltage
Under Voltage Lockout (UVLO)
Output Voltage Trimming
50VDC
100VDC
9VDC
18VDC
-10%
-10%
Minimum Load
+10%
+20%
0%
Power up
ON/OFF CTRL
Start-up Time
30ms
30ms
Positive Logic
DC-DC ON
DC-DC OFF
Open or 3.0VDC < VCTRL< 15VDC
Short or 0VDC < VCTRL< 1.2VDC
Negative Logic
DC-DC ON
DC-DC OFF
Input Current of CTRL pin
drive current
ICTRL
Short or 0VDC < VCTRL< 1.2VDC
Open or 3.0VDC < VCTRL< 15VDC
+1.0mA
Standby Current
DC-DC OFF
IIn
ON/OFF CTRL (5)
refer to “ON/OFF CTRL”
-0.5mA
2.5mA
Internal Operating Frequency
297kHz
Output Ripple and Noise
330kHz
measured at 20MHz BW,
with a 10µF/25V X7R 1206 MLCC
3.3Vout, 5Vout
12Vout, 15Vout
40mVp-p
60mVp-p
measured at 20MHz BW,
with a 1µF/50V X7R 1206 MLCC
24Vout
60mVp-p
Input Reflected Ripple Current
363kHz
30mAp-p
Notes:
Note5: If suffix “XC” is specified, the control pin will be absent. If fitted, the ON/OFF control function
can be positive or negative logic. The pin voltage is referenced to -Vin
100
95
90
85
80
75
70
65
60
55
50
45
40
10
Efficiency vs. Input Voltage full load
Efficiency vs. Output Current
100
95
90
Efficiency [%]
Efficiency [%]
RP10-2405SAW
30
40
50
60
70
80
90
80
75
70
9Vin
24Vin
36Vin
20
85
65
60
100
9
Output Current [%]
14
19
24
29
34
Input Voltage [VDC]
continued on next page
www.recom-power.com
REV.: 7/2020
PD-2
RP10-AW
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
ON/OFF CTRL
IIN
+Vin
ICTRL
VCTRL
+Vin
+Vout
+Vout
Positve Logic
DC-DC ON
DC-DC OFF
Open or 3.0VDC < VCTRL < 15VDC
Short or 0VDC < VCTRL < 1.2VDC
Negativ Logic
DC-DC ON
DC-DC OFF
Short or 0VDC < VCTRL < 1.2VDC
Open or 3.0VDC < VCTRL < 15VDC
CTRL
-Vin
-Vin
-Vout
-Vout
OUTPUT VOLTAGE TRIMMING
Output Voltage Trimming
Single output Powerline converters offer the feature of trimming the output voltage over a certain range around the nominal value by using external
trim resistors. No general equation can be given for calculating the trim resistors, but the following trimtables give typical values for choosing these
trimming resistors. If voltages between the given trim points are required, extrapolate between the two nearest given values to work out the resistor
required or use a variable resistor to set the output voltage. Output can be externally trimmed by using the method shown below.
-Vout
Trim up
Trim
Trim down
RD
RU
+Vout
Trim
RP10-xx3.3SAW
Trim up
1
2
3
4
5
6
7
8
9
10
[%]
Vout =
3.333
3.366
3.399
3.432
3.465
3.498
3.531
3.564
3.597
3.63
[VDC]
385.071
191.511
126.990
94.730
75.374
62.470
53.253
46.340
40.963
36.662
[kW]
1
2
3
4
5
6
7
8
9
10
[%]
RU =
Trim down
Vout =
RD =
3.267
3.234
3.201
3.168
3.135
3.102
3.069
3.036
3.003
2.97
[VDC]
116.719
54.779
34.133
23.810
17.616
13.486
10.537
8.325
6.604
5.228
[kW]
2
3
4
5
6
7
8
9
10
[%]
RP10-xx05SAW
Trim up
Vout =
RU =
Trim up
Vout =
RU =
Trim down
Vout =
RD =
1
5.05
5.10
5.15
5.20
5.25
5.30
5.35
5.4
5.45
5.50
[VDC]
253.450
125.700
83.117
61.825
49.050
40.533
34.450
29.888
26.339
23.500
[kW]
11
12
13
14
15
16
17
18
19
20
[%]
5.55
5.60
5.65
5.70
5.75
5.80
5.85
5.90
5.95
6.00
[VDC]
21.177
19.242
17.604
16.200
14.983
13.919
12.979
12.144
11.397
10.725
[kW]
1
2
3
4
5
6
7
8
9
10
[%]
4.95
4.90
4.85
4.80
4.75
4.70
4.65
4.60
4.55
4.50
[VDC]
248.340
120.590
78.007
56.715
43.940
35.423
29.340
24.778
21.229
18.390
[kW]
2
3
4
5
6
7
8
9
10
[%]
RP10-xx12SAW
Trim up
Vout =
RU =
Trim down
Vout =
RD =
1
12.12
12.24
12.36
12.48
12.60
12.72
12.84
12.96
13.08
13.20
[VDC]
203.223
99.057
64.334
46.973
36.557
29.612
24.652
20.932
18.038
15.723
[kW]
1
2
3
4
5
6
7
8
9
10
[%]
11.88
11.76
11.64
11.52
11.40
11.28
11.16
11.04
10.92
10.8
[VDC]
776.557
380.723
248.779
182.807
143.223
116.834
97.985
83.848
72.853
64.057
[kW]
continued on next page
www.recom-power.com
REV.: 7/2020
PD-3
RP10-AW
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
RP10-xx15SAW
Trim up
1
3
4
5
6
7
8
9
10
[%]
15.15
15.30
15.45
15.60
15.75
15.90
16.05
16.20
16.35
16.50
[VDC]
161.557
78.223
50.446
36.557
28.223
22.668
18.700
15.723
13.409
11.557
[kW]
Vout =
RU =
2
Trim up
11
12
13
14
15
16
17
18
19
20
[%]
Vout =
16.65
16.80
16.95
17.10
17.25
17.40
17.55
17.70
17.85
18.00
[VDC]
RU =
10.042
8.779
7.711
6.795
6.001
5.307
4.694
4.149
3.662
3.223
[kW]
1
2
3
4
5
6
7
8
9
10
[%]
14.85
14.70
14.55
14.40
14.25
14.10
13.95
13.80
13.65
13.50
[VDC]
818.223
401.557
262.668
193.223
151.557
123.779
103.938
89.057
77.483
68.223
[kW]
Trim down
Vout =
RD =
RP10-xx24SAW
Trim up
1
2
3
4
5
6
7
8
9
10
[%]
Vout =
24.24
24.48
24.72
24.96
25.20
25.44
25.68
25.92
26.16
26.40
[VDC]
570.333
278.667
181.444
132.833
13.667
84.222
70.333
59.917
51.815
45.333
[kW]
11
12
13
14
15
16
17
18
19
20
[%]
RU =
Trim up
Vout =
26.64
26.88
27.12
27.36
27.60
27.84
28.08
28.32
28.56
28.80
[VDC]
RU =
40.030
35.611
31.872
28.667
25.889
23.458
21.314
19.407
17.702
16.167
[kW]
1
2
3
4
5
6
7
8
9
10
[%]
Trim down
23.76
23.52
23.28
23.04
22.80
22.56
22.32
22.08
21.84
21.60
[VDC]
4947.667
2439.333
1603.222
1185.167
934.333
767.111
647.667
558.083
488.407
432.667
[kW]
Vout =
RD =
REGULATIONS
Parameter
Condition
Value
Output Accuracy
Line Regulation
±1.0%
low line to high line,
full load
Single
Dual
±0.2%
±0.5%
0% to 100% load
Single
Dual
±0.2%
±1.0%
10% to 90% load
Single
Dual
±0.1%
±0.8%
asymmetrical 25%100% load
±5.0%
Load Regulation
Cross Regulation
Transient Response Recovery Time
www.recom-power.com
25% load step change
REV.: 7/2020
250μs typ.
PD-4
RP10-AW
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
PROTECTIONS
Parameter
Condition
Value
Short Circuit Protection (SCP)
continuous, automatic recovery
Over Voltage Protection (OVP)
zener diode clamp
Over Load Protection (OLP)
3.7 - 5.4VDC
6.3 - 7.4VDC
13.5 - 19.6VDC
18.3 - 22.0VDC
29.1 - 32.5VDC
3.3Vout
5Vout
12Vout
15Vout
24Vout
% of Iout rated
Isolation Voltage (6)
I/P to O/P
I/P to O/P to case
Isolation Resistance
Viso= 500VDC
150% typ., Hiccup mode
1.6kVDC/ 1 minute
1.0kVDC/ 1 minute
1GΩ min.
1500pF max.
Isolation Capacitance
Notes:
Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note7: This power module is not internally fused. An input line fuse must always be used
Recom suggests: 24Vin= T2A; 48Vin= T1A slow blow types
ENVIRONMENTAL
Parameter
Condition
Value
-40°C to +78°C
-40°C to +100°C
without derating
with derating
Operating Temperature Range
Maximum Case Temperature
+105°C
Temperature Coefficient
±0.02%/K max.
Thermal Impedance
@ natural convection 0.1m/s
Operating Humidity
without heat-sink
with heat-sink
18.2K/W
15.8K/W
non-condensing
5% - 95% RH
Thermal Shock
according to MIL-STD-810F
Vibration
according to MIL-STD-810F
MTBF
according to MIL-HDBK-217F, G.B.
+25°C
3376 x 103 hours
Derating Graph (8)
RP10-2405SAW-HC
100
100
80
80
Output Power [%]
Output Power [%]
RP10-2405SAW
60
40
20
0
-40
-20
0
20
40
60 78 80
60
40
20
0
-40
100
Ambient Temperature [°C]
-20
0
20
40
60
80
81
100
Ambient Temperature [°C]
Notes:
Note8: Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-number
not shown here please contact RECOM Techsupport for detailed information
www.recom-power.com
REV.: 7/2020
PD-5
RP10-AW
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Condition
Information Technology Equipment, General Requirements for Safety
Standard
UL60950-1, 1st Edition
CAN/CSA-C22.2 No. 60950-1, 1st Edition
E196683
EAC
RU-AT.49.09571
TP TC 004/2011
RoHS2+
RoHS-2011/65/EU + AM-2015/863
EMC Compliance
Condition
Electromagnetic compatibility of multimedia equipment - Emission
requirements
Standard / Criterion
without external filter
refer to “EMC Filtering Suggestions”
ESD Electrostatic discharge immunity test
EN55032, Class A
EN55032, Class B
Air ±8kV and Contact ±6kV
EN61000-4-2, Criteria A
Radiated, radio-frequency, electromagnetic field immunity test
10V/m
EN61000-4-3, Criteria A
Fast Transient and Burst Immunity
±2kV
EN61000-4-4, Criteria A
±1kV
EN61000-4-5, Criteria A
3Vr.m.s
EN61000-4-6, Criteria A
100A/m continuous; 1000A/m 1s
EN61000-4-8, Criteria A
(9)
Surge Immunity (9)
Immunity to conducted disturbances, induced by radio-frequency fields
Power Magnetic Field Immunity
Notes:
Note9: An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5
Recom suggests Nippon chemi-con KY series 220μF/100V
EMC Filtering Suggestions according to EN55032
Single
+Vin
F1
+Vin
+Vout
+Vout
+Vin
C1
Dual
F1
+Vin
+Vout
C1
Com
-Vin
-Vin
-Vout
-Vout
-Vin
-Vin
-Vout
+Vout
Com
-Vout
Component List Class B
MODEL
C1
RP10-24xxSAW, RP10-24xxDAW
6.8μF/50V, 1812 MLCC
RP10-48xxSAW, RP10-48xxDAW
4.7μF/100V, 1812 MLCC
DIMENSIONS AND PHYSICAL CHARACTERISTICS
Parameter
Material
Dimensions (LxWxH)
Weight
Type
Value
case
base
potting
without Heat-sink
with Heat-sink
copper alloy C2680
FR4 PCB
epoxy (UL94 V-0)
25.4 x 25.4 x 9.9mm
31.4 x 25.4 x 16.5mm
without Heat-sink
with Heat-sink
16.5g
23g
continued on next page
www.recom-power.com
REV.: 7/2020
PD-6
RP10-AW
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Dimension Drawing (mm)
Pinning Information
25.4
5.6
9.9
25.4
2.54
8 x 2.54= 20.32
Ø 1.0±0.1
Recommended Footprint Details
3
2
Bottom View
3
2
5
1
6
2.54
2.54
1
12.70
7.62
4
10.2
5.08
2.54
Top View
Pin #
1
2
3
4
5
6
Single
+Vin
-Vin
CTRL (3)
+Vout
Trim
-Vout
Dual
+Vin
-Vin
CTRL (3)
+Vout
Com
-Vout
“/XC“
+Vin
-Vin
no Pin (3)
+Vout
Trim
-Vout
Pin Pitch Tolerance ±0.25mm
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.25mm
5
4
6
Dimension Drawing with Heat-sink (mm)
25.4
25.4
Top View
Heat-sink
24.2
Pinning Information
5.6
16.5
9.9
5.85
31.4
2.54
8 x 2.54= 20.32
Ø 1.0±0.1
Recommended Footprint Details
2
Bottom View
3
www.recom-power.com
5
6
6
3
2
1
Single
+Vin
-Vin
CTRL (3)
+Vout
Trim
-Vout
Dual
+Vin
-Vin
CTRL (3)
+Vout
Com
-Vout
“/XC-HC“
+Vin
-Vin
no Pin (3)
+Vout
Trim
-Vout
Pin Pitch Tolerance ±0.25mm
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.25mm
2.54
2.54
1
12.70
7.62
4
10.2
5.08
2.54
Pin #
1
2
3
4
5
6
Top View
5
4
REV.: 7/2020
PD-7
RP10-AW
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
PACKAGING INFORMATION
Parameter
Type
Value
Packaging Dimension (LxWxH)
tube
tray
without heat-sink
with heat-sink
257.0 x 28.5 x 21.0mm
230.0 x 180.0 x 28.0mm
Packaging Quantity
tube
tray
without heat-sink
with heat-sink
8pcs
20pcs
Storage Temperature Range
Storage Humidity
-55°C to +125°C
non-condensing
5% - 95% RH
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 7/2020
PD-8