Features
• 4:1 wide input range
• 3kVAC reinforced insulation for 110Vin
2.25kVDC basic insulation for 24Vin & 48Vin
• Efficiency up to 93%
• No minimum load required
• EN50155, IEC/EN60950-1 & UL60950-1 certified
Regulated
Converter
Description
DC/DC Converter
RP100H-RW
100 Watt
3
Half Brick
Single Output
YEA R
y
arrant
w
The half-brick RP100H series DC/DC converters are designed for railway rolling stock and high voltage battery
applications. Each series has three 4:1 input voltage range options to cover all input voltages from 9VDC up to
160VDC with isolated and regulated 5V to 48VDC outputs. The converters have high efficiencies and metal baseplates to permit a wide operating temperature range from -40°C to +85°C (when mounted on a suitable heatsink).
The case is fitted with threaded inserts to allow secure mounting to the PCB or bulkhead for use in high shock
and vibration environments. The converters are EN50155, UL60950 and IEC/EN60950 certified. The RP100H-RW
series have a three year warranty.
T
CONVER
T
S
S
RE
M
R
R
C
TS
compliant
PL
U
D
IA N
T PRO
CO
10 from 10
O
REACH
compliant
M
C
M
TS
CONVER
C
M
E
O
E
C
RoHS 2 +
CO
Part Number
Input
Output Output Input(1) Output Efficiency(1) Max. Capacitive
Voltage Range Voltage Current Current Power
typ.
Load
[VDC] [VDC] [mA] [mA] [W] [%]
[µF]
RP100H-2405SRW 9-36
5 20000 4480 100 93
40000
7000
RP100H-2412SRW 9-36 12 8400 4666 101 90
RP100H-2415SRW 9-36 15 6700 4601 100 91
4460
RP100H-2424SRW 9-36 24 4200 4666 101 90
1750
430
RP100H-2448SRW 9-36 48 2100 4666 101 90
RP100H-4805SRW 16.5-75 5 20000 2240 100 93
40000
RP100H-4812SRW 16.5-75 12 8400 2333 101 90
7000
RP100H-4815SRW 16.5-75 15 6700 2300 100 91
4460
1750
RP100H-4824SRW 16.5-75 24 4200 2333 101 90
430
RP100H-4848SRW 16.5-75 48 2100 2307 101 90
RP100H-11005SRW 43-160
5 20000 1010 100
93
40000
RP100H-11012SRW 43-160
12 8400 1018 101
90
7000
RP100H-11015SRW 43-160
15 6700 1015 100
91
4460
RP100H-11024SRW 43-160
24 4200 1018 101
90
1750
48 2100 1007 101
90
430
RP100H-11048SRW 43-160
RE
Selection Guide
PL
U
D
IA N
T PRO
E196683
EN50155 certified
IEC/EN60950-1 certified
UL60950-1 certified
Notes:
Note1: Efficiency is tested by nominal Vin, full load and at 25°C
Model Numbering
REF
DESIGN
available
RP100H-__ __ SRW/_ _
Input Voltage
Output Voltage
Package(3)
CTRL Logic(2)
https://recom-power.com/rec-s-RREF04-RIA12.html
Single
Notes:
Note2:
Note3:
standard part is with suffix “P” for positive logic (1=ON, 0=OFF)
or add suffix “N” instead for negative logic (0=ON, 1=OFF)
for more details refer to “ON/OFF CTRL (4)”
add suffix “-HC” for premounted Heat-sink (refer to “Dimension Drawing Heat-sink (mm)”)
(compatible with all other suffixes)
Ordering Examples
RP100H-2405SRW/N = 24V Input, 5V Output, Single, Neg. CTRL function
RP100H-11012SRW/P = 110V Input, 12V Output, Single, Pos. CTRL function
RP100H-2405SRW/N-HC = 24V Input, 5V Output, Single, Neg. CTRL function, premounted Heat-sink
www.recom-power.com
REV.: 4/2020
SURGE
PROTECTOR
available
https://recom-power.com/rec-sRSPxxx-168.html
PA-1
RP100H-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
nom Vin = 24V
nom Vin = 48V
nom Vin = 110V
Vin = 24V, 1s max.
Vin = 48V, 1s max.
Vin = 110V, 1s max.
9VDC
16.5VDC
43VDC
24VDC
48VDC
110VDC
Max.
Internal Input Filter
Vin = 24V
DC-DC ON
DC-DC OFF
7.3VDC
Pi-Type
36VDC
75VDC
160VDC
50VDC
100VDC
185VDC
9VDC
8.1VDC
Vin = 48V
DC-DC ON
DC-DC OFF
15.5VDC
18VDC
16.3VDC
Vin = 110V
DC-DC ON
DC-DC OFF
33.0VDC
25mA
15mA
43VDC
36.0VDC
35mA
25mA
Input Voltage Range
Input Surge Voltage
Under Voltage Lockout (UVLO)
Vin = 24V
Vin = 48V
Vin = 110V
refer to “OUTPUT VOLTAGE TRIMMING”
Quiescent Current
Output Voltage Trimming
10mA
-20%
Minimum Load
+10%
0%
Power up
Remote ON/OFF
Start-up time
75ms
75ms
Positive Logic
DC-DC ON
DC-DC OFF
Open or 3.0VDC < VCTRL < 12VDC
Short or 0VDC < VCTRL < 1.2VDC
Negative Logic
DC-DC ON
DC-DC OFF
Short or 0VDC < VCTRL < 1.2VDC
Open or 3.0VDC < VCTRL < 12VDC
Input Current of CTRL pin
drive current
ICTRL
Standby Current
DC-DC OFF
IIn
ON/OFF CTRL (4)
refer to “ON/OFF CTRL”
-0.5mA
3mA
Vin = 24V, Vin =48V
Vin = 110V
Internal Operating Frequency
1mA
225kHz
270kHz
250kHz
300kHz
75mVp-p
100mVp-p
200mVp-p
300mVp-p
with a 1µF/25V X7R MLCC & a 22µF/25V POS Cap
5 Vout
Measured by
with a 1µF/25V X7R MLCC & a 22µF/25V POS Cap 12, 15Vout
20MHz BW
with a 4.7µF/50V X7R MLCC
24Vout
with a 2.2µF/100V X7R MLCC
48Vout
Output Ripple and Noise
275kHz
330kHz
% of nom Vout (refer to “REMOTE SENSE”)
Remote Sense
10%
Notes:
Note4: The ON/OFF control function can be positive or negative logic. The pin voltage is referenced to -Vin
RP100H-2405SRW
Efficiency vs. Output Current
90
90
80
80
70
60
50
40
30
10
70
60
50
40
100% Load
50% Load
25% Load
30
9Vin
24Vin
36Vin
20
0
Efficiency vs. Input Voltage
100
Efficiency [%]
Efficiency [%]
100
20
10
10
20
30
40
50
60
70
Output Current [%]
www.recom-power.com
80
90
100
continued on next page
REV.: 4/2020
9
12
15
18
21
24
27
30
33
36
Input Voltage [V]
PA-2
RP100H-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
RP100H-2405SRW
Power Dissipation [W]
Typical Output Ripple and Noise/full load
Power Dissipation vs. Output Current
18
15
12
9
6
9Vin
24Vin
36Vin
3
0
10
20
30
40
50
60
70
80
90
100
Output Current [%]
ON/OFF Control Start-up Rise Characteristic
Power up Start-up Characteristic
RP100H-4805SRW
Efficiency vs. Output Current
90
90
80
80
70
60
50
40
30
16.5Vin
48Vin
75Vin
20
10
0
10
20
30
40
50
60
70
Output Current [%]
www.recom-power.com
Efficiency vs. Input Voltage
100
Efficiency [%]
Efficiency [%]
100
80
90
70
60
50
40
100% Load
50% Load
25% Load
30
20
100
10
16.5
continued on next page
REV.: 4/2020
24
30
36
42
48
54
60
66
72
75
Input Voltage [V]
PA-3
RP100H-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
RP100H-4805SRW
Power Dissipation vs. Output Current
18
Typical Output Ripple and Noise/full load
Power Dissipation [W]
15
12
9
6
16.5Vin
48Vin
75Vin
3
0
10
20
30
40
50
60
70
80
90
100
Output Current [%]
ON/OFF Control Start-up Rise Characteristic
Power up Start-up Characteristic
RP100H-11005SRW
Efficiency vs. Output Current
90
90
80
80
70
60
50
40
30
10
70
60
50
40
20
10
10
20
30
40
50
60
70
80
90
100% Load
50% Load
25% Load
30
43Vin
110Vin
160Vin
20
0
Efficiency vs. Input Voltage
100
Efficiency [%]
Efficiency [%]
100
100
43
60
65
80
95
110
125
140
155 160
Input Voltage [V]
Output Current [%]
continued on next page
www.recom-power.com
REV.: 4/2020
PA-4
RP100H-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
RP100H-11005SRW
Power Dissipation vs. Output Current
Typical Output Ripple and Noise
Power Dissipation [W]
18
15
12
9
6
43Vin
110Vin
160Vin
3
0
10
20
30
40
50
60
70
80
90
100
Output Current [%]
ON/OFF Control Start-up Rise Characteristic
Power up Start-up Characteristic
ON/OFF CTRL
+Vin
VCTRL
-Vin
IIN
ICTRL
+Vin
+Vout
+Vout
Positve Logic
DC-DC ON
DC-DC OFF
Open or 3.0VDC < VCTRL < 12VDC
Short or 0VDC < VCTRL < 1.2VDC
Negativ Logic
DC-DC ON
DC-DC OFF
Short or 0VDC < VCTRL < 1.2VDC
Open or 3.0VDC < VCTRL < 12VDC
CTRL
-Vin
-Vout
-Vout
REMOTE SENSE
+Vin
RW1
+Vout
+Sense
R1
Load
Trim
R2
-Sense
-Vin
www.recom-power.com
-Vout
(GND)
RW2
The output voltage can be adjusted by both trim and remote sense. The
maximum combined adjustment range ±10%. Derate the maximum output power if using the trim or sense function.
RW1 ... wire losses +
RW2 ... wire losses R1 ... trim up resistor
R2 ... trim down resistor
REV.: 4/2020
PA-5
RP100H-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
OUTPUT VOLTAGE TRIMMING
Output Voltage Trimming
RP100H-RW converters offer the feature of trimming the output voltage over a certain range around the nominal value by using external trim
resistors. The values for trim resistors shown in trim tables below are according to standard E96 values; therefore, the specified voltage may
slightly vary; they also can be calculated with below shown equation.
TRIM UP
TRIM DOWN
TRIM
-Sense
R1
R2
+Sense
TRIM
Trim Calculation
R1 =
100*Vout+DVout * Vout)
R2 =
-
1.225*DVout
100
DVout
- 2 kΩ
(100+2DVout)
DVout
kΩ
Vout
=
Output Voltage
DVout
=
Output Voltage Trim in %
R1
=
trim up resistor
R2
=
trim down resistor
Practical Example:
Trim Up:
Vout = 5V, DVout = 10% (5.5V)
R1 =
100*Vout+DVout * Vout)
(100+2DVout)
-
1.225*DVout
DVout
kΩ =
100*5 +10*5
1.225*10
-
100+2*10
10
= 44.89 - 12 = 32.9kΩ
Trim down:
Vout = 5V, DVout = -10% (4.5V)
R2 =
100
DVout
- 2 kΩ =
100
10
- 2 = 8.06kΩ
RP100H-xx05SRW
Trim up
1
2
3
4
5
6
7
8
9
10
%
Vout =
5.05
5.10
5.15
5.20
5.25
5.30
5.35
5.4
5.45
5.50
Volts
R1 =
309
158
105
78.7
63.4
53.6
46.4
40.2
36.5
33.2
kOhms
RP100H-xx12SRW
Trim up
1
2
3
4
5
6
7
8
9
10
Vout =
12.12
12.24
12.36
12.48
12.60
12.72
12.84
12.96
13.08
13.20
Volts
887
453
301
226
182
154
133
118
105
95.3
kOhms
R1 =
%
RP100H-xx15SRW
Trim up
1
2
3
4
5
6
7
8
9
10
Vout =
15.15
15.30
15.45
15.60
15.75
15.90
16.05
16.20
16.35
16.50
R1 =
1130
576
383
294
237
196
169
150
137
124
%
Volts
kOhms
continued on next page
www.recom-power.com
REV.: 4/2020
PA-6
RP100H-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
OUTPUT VOLTAGE TRIMMING
RP100H-xx24SRW
Trim up
1
2
3
4
5
6
7
8
9
10
%
Vout =
24.24
24.48
24.72
24.96
25.20
25.44
25.68
25.92
26.16
26.40
RU =
1870
953
634
487
392
324
280
249
226
205
kOhms
%
Volts
RP100H-xx48SRW
Trim up
1
2
3
4
5
6
7
8
9
10
Vout =
48.48
48.96
49.44
49.92
50.40
50.88
51.36
51.84
52.32
52.80
R1 =
3830
1960
1300
1000
806
681
576
511
464
422
kOhms
1
2
3
4
5
6
7
8
9
10
%
97.6
47.5
31.6
23.2
17.8
14.7
12.1
10.5
9.09
8.06
Volts
Trim Down all Vout‘s
Trim down
R2 =
Trim down
R2 =
11
12
13
14
15
16
17
18
19
20
7.15
6.34
5.76
5.11
4.64
4.22
3.92
3.57
3.24
3.01
kOhms
%
kOhms
REGULATIONS
Parameter
Condition
Value
Output Accuracy
±1.0%
Line Regulation
low line to high line at full load
Load Regulation
0% to 100% load
Transient Response
±0.1%
0.1%
25% load step change
200µs typ.; 250μs max.
Transient Response to Dynamic Load Change from 100% to 75% to 100% of Full Load at nom.Vin
RP100H-2405SRW
RP100H-4805SRW
continued on next page
www.recom-power.com
REV.: 4/2020
PA-7
RP100H-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
RP100H-11005SRW
PROTECTIONS
Parameter
Condition
Value
Short Circuit Protection (SCP)
below 100mΩ
continuous, automatic recovery
Over Voltage Protection (OVP)
% of nom. Vout
115%-130%, Hiccup Mode
Over Load Protection (OLP)
24Vin, 48Vin
110Vin
% Iout rated
Over Temperature Protection (OTP)
+110°C to +120°C
110Vin
I/P to O/P
I/P or O/P to Case
3kVAC/1minute
1.5kVAC/1minute
24Vin, 48Vin
I/P to O/P
I/P or O/P to Case
2.25kVDC/1minute
1.6kVDC/1minute
Isolation Voltage
Isolation Resistance
120%-150%, Hiccup Mode
150% typ., Hiccup Mode
500 VDC
1GΩ min.
Isolation Capacitance
2500pF max.
110 Vin
24Vin, 48Vin
Isolation Grade
reinforced insulation
basic insulation
Notes:
Note5: Refer to local wiring regulations if input over-current protection is also required. Recommended fuse: T35A slow blow.
ENVIRONMENTAL
Parameter
Condition
Operating Case Temperature Range
Maximum Case Temperature
105°C
Temperature Coefficient
Thermal Impedance
±0.02%/°C max.
vertical direction by natural convection (0.1m/s) without Heat-sink
vertical direction by natural convection (0.1m/s) with Heat-sink
Operating Humidity
6.7°C/W
4.7°C/W
5% - 95% RH
Pollution Degree
PD2
Shock
according to EN61373 standard
Thermal Shock
according to MIL-STD-810F standard
Vibration
according to EN61373 standard
Fire protection on railway vehicles
MTBF
Value
refer to derating graph
according to EN45545-2, 2013 standard
according to MIL-HDBK-217F standard, 25°C
408.7 x 103 hours
continued on next page
www.recom-power.com
REV.: 4/2020
PA-8
RP100H-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
Thermal Calculation
Rthcase-ambient = 6.7°C/W (vertical)
Tcase
=
Case Temperature
Rthcase-ambientHC = 4.7°C/W (vertical)
Tambient
=
Environment Temperature
Pdissipation
=
Internal losses
T -T
Rthcase-ambient = case ambient PIN
=
Input Power
Pdissipation
POUT
=
Output Power
h
=
Efficiency under given Operating Conditions
P
Pdissipation = PIN - POUT = OUTapp
P
R
=
Thermal
Impedance
OUTapp
thcase-ambient
h
Practical Example:
Take the RP100H-2405SRW with 9V input Voltage and 50% load. What is the maximum ambient operating temperature? Use converter vertical in application without
airflow.
Effmin = 91% @ Vnom
without Heat-sink
with Heat-sink
POUT = 100W
T
105-Tamb
T
105-Tamb
-T
-T
Rth = casemax amb --> 6.7°C/W =
RthHC = casemax amb --> 4.7°C/W =
POUTapp = 100 x 0.5 = 50W
4.95W
Pdissipation
Pdissipation
4.95W
h = 91% (Efficiency vs. Load Graph)
Tamb = 72°C TambHC = 82°C
50
Pdissipation =
- 50 = 4.95W
0.91
Derating Graph(6)
(@ Chamber - tested with forced convection)
RP100H-2405SRW-HC
100
100
80
80
Output Power [%]
Output Power [%]
RP100H-2405SRW
60
40
0.5m/s
1m/s
1.5m/s
2m/s
2.5m/s
20
0
-40
-20
0
60
40
natural convection
0.5m/s
1m/s
1.5m/s
2m/s
2.5m/s
20
20
40
60
80
0
-40
100 120
Ambient Temperature [°C]
-20
80
80
Output Power [%]
Output Power [%]
100
60
0
-40
0.5m/s
1m/s
1.5m/s
2m/s
2.5m/s
-20
0
40
60
60
67
80
100 120
60
40
natural convection
0.5m/s
1m/s
1.5m/s
2m/s
2.5m/s
20
20
40
RP100H-4805SRW-HC
100
20
20
Ambient Temperature [°C]
RP100H-4805SRW
40
0
65
80
0
-40
100 120
-20
0
20
40
60
71
80
100 120
Ambient Temperature [°C]
Ambient Temperature [°C]
continued on next page
www.recom-power.com
REV.: 4/2020
PA-9
RP100H-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
RP100H-11005SRW
RP100H-11005SRW-HC
80
80
Output Power [%]
100
Output Power [%]
100
60
40
0.5m/s
1m/s
1.5m/s
2m/s
2.5m/s
20
0
-40
-20
0
60
40
natural convection
0.5m/s
1m/s
1.5m/s
2m/s
2.5m/s
20
20
40
60
80
0
-40
100 120
Ambient Temperature [°C]
-20
0
20
40
50
60
80
100 120
Ambient Temperature [°C]
Notes:
Note6: Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-
number not shown here please contact our technical support service at techsupportAT@recom-power.com
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report / File Number
Information Technology Equipment, General Requirements for Safety
E196683
Information Technology Equipment - General Requirments for Safety
TW1608033-001, TW1608036-001,
TW1608037-001, TW1608079-001
Standard
UL60950-1, 2nd Edition, 2014
CSA C22.2 No. 60950-1-07,
2nd Edition, 2014
IEC60950-1, 2nd Edition. 2005
EN60950-1, 2006
Railway Applications - Electrical Equipment used on rolling stock
16A081501E-C
EN50155, 2007
EAC
RU-AT.49.09571
TP TC 004/2011
RoHS2+
RoHS 2011/65/EU
EMI Compliance
Condition
Information technology equipment - Radio disturbance characteristics - Limits and
methods of measurement
Industrial, scientific and medical equipment - Radio frequency disturbance
characteristics - Limits and methods of measurement
www.recom-power.com
EN55032, Class A and Class B
with external components
EN55011, Class A and Class B
ESD Electrostatic discharge immunity test
Radiated, radio-frequency, electromagnetic field immunity test
Fast Transient and Burst Immunity(7)
Surge Immunity(7)
Immunity to conducted disturbances, induced by radio-frequency fields
Power Magnetic Field Immunity
Notes:
Note7:
Standard / Criterion
Air ±8kV and Contact ±6kV
20 V/m
±2kV
±2kV
10 Vr.m.s
100A/m continuous; 1000A/m 1s
EN61000-4-2, Criteria A
EN61000-4-3, Criteria A
EN61000-4-4, Criteria A
EN61000-4-5, Criteria A
EN61000-4-6, Criteria A
EN61000-4-8, Criteria A
An external input filter capacitor is required if the module has to meet EN61000-4-4 and EN61000-4-5.
The 24Vin and 48Vin version recommend 2pcs of aluminium elecrolytic capacitor to connect in parallel.
Recom suggest: Nippon Chemi-con KY series, 220µF/100V.
The 110Vin version recommend 2pcs of aluminium electrolytic capacitor to connect in parallel.
Recom suggest: Nippon Chemi-con KXJ series, 150µF/200V
continued on next page
REV.: 4/2020
PA-10
RP100H-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
RP100-24xxSRW, Class A
RP100-48xxSRW, Class A
EMI Filtering according to EN55032/11 Class A and EN50121-1 (24Vin and 48Vin)
C10
L1
C1
C2
C3
C4
C5
C7
C6
LOAD
Fuse
+VIN
Case
-VIN
C9
C8
C12
C13
C11
Shield Plane
RP100-110xxSRW, Class AMODEL
C1, C2, C4
C8, C9, C10,
C11, C13
C12
L1
C18
RP100H-24xxSRW
470µF, 50V
Al cap.
L1 (lie down) Chemi-con KY
4.7µF, 50V
1812 MLCC
1000pF, 3kV
1808 MLCC
3300pF, 3kV
1808 MLCC
156µH
CMC
RP100H-48xxSRW
220µF, 100V
Al cap. (lie down) Chemi-con KY
2.2µF, 100V
1812 MLCC
1000pF, 3kV
1808 MLCC
1000pF, 3kV
1808 MLCC
224µH
CMC
C1
C2
C3
C8
C9
C10
LOAD
Fuse
+VIN
C3, C6, C7
Case
RP100H-2405SRW
Conducted Emission EN55032 Class A
-VIN
C7
C6
C5
C11
C4
C12
C13
C17
C14
C19
C16
C15
C20
Shield Plane
RP100-110xxSRW, Class B
C15
L1
Fuse
L2
C3
C1
C2
RP100H-4805SRW
C4
C10
C11 C12
LOAD
+VIN
Conducted Emission EN55032 Class A Case
-VIN
C9
C5
C8
C7
C13 C14
C6
C19
C16
C20
C21
C22
C17
C18
Shield Plane
RP100-24xxSRW, Class B
RP100-48xxSRW, Class B
C11
C1
www.recom-power.com
-VIN
L2
L1
Fuse
C2
C3
C4
C5
continued on next page
C6
C7
REV.: 4/2020
C8
Case
LOAD
+VIN
PA-11
C1
C2
C3
C4
C5
C7
C6
LOAD
IN
RP100H-RW
Case
-VIN
DC/DC Converter
C9
C8
C12
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
EMI Filtering according to EN55032/11 Class A and EN50121-1 (110Vin)
C11
Series
C13
Shield Plane
RP100-110xxSRW, Class A
C18
L1
C1
C2
C3
C8
C9
C10
LOAD
Fuse
+VIN
Case
-VIN
C7
C6
C5
C11
C4
C12
C13
C17
C14
C19
C16
C15
C20
Shield Plane
C1, C2, C8
RP100H-110xxSRW
+VIN
L1
Fuse
C1
C10
C6, C11, C12, C13, C14,
C15, C16, C19, C20
C17, C18
L1
1000pF, 5kV
1808 MLCC
2200pFC15
TDK CD series Y1
1219µH
CMC
100µF, 250V
1µF, 250V
Al cap. (lie down) Rubycon BXF 1812 MLCC
L2
C3
C2
C4
C10
C11 C12
LOAD
RP100-110xxSRW,MODEL
Class B
Case
-VIN
C9
C5
C8
C7
C13 C14
C6
C16
C20
C19
C21
C17
C22
RP100H-11005SRW
Conducted Emission EN55032 Class A
Shield Plane
RP100-24xxSRW, Class B
RP100-48xxSRW, Class B
C11
L2
L1
Fuse
C1
C2
C3
C4
C5
C6
C7
C8
LOAD
+VIN
Case
-VIN
C10
C15
continued on next page
www.recom-power.com
REV.: 4/2020
C9
C12
C14
C13
Shield Plane
PA-12
C18
N
C9
C5
C8
C7
C13 C14
C6
C16
C20
C19
C18
C17
C22
C21
RP100H-RW
DC/DC Converter
Series
Shield Plane
-24xxSRW, Class
B
Specifications
(measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
-48xxSRW, Class B
EMI Filtering according to EN55032/11 Class B (24Vin and 48Vin)
L2
L1
Fuse
C1
C3
C2
C4
C5
C6
C7
C8
LOAD
+VIN
C11
Case
-VIN
C10
C15
C9
C12
C14
C13
Shield Plane
MODEL
C1, C3, C6
C2, C4,
C5, C7, C8
C9, C10
C11
470µF, 50V
4.7µF, 50V 10nF, 2kV 1000pF, 3kV
Al cap. (lie down) Chemi-con KY 1812 MLCC 1812 MLCC 1808 MLCC
220µF, 100V
2.2µF, 100V 10nF, 100V 2200pF, 3kV
RP100H-48xxSRW
Al cap. (lie down) Chemi-con KY 1812 MLCC 1812 MLCC 1808 MLCC
RP100H-24xxSRW
RP100H-2405SRW
RP100H-4805SRW
C12
C13, C14
C15
4700pF, 3kV 10nF, 2kV
N/A
1812 MLCC 1812 MLCC
4700pf, 3kV 10nF, 2kV 1000pF, 3kV
1812 MLCC 1812 MLCC 1808 MLCC
L1
156µH
CMC
224µH
CMC
Conducted Emission EN55032 Class B
Conducted Emission EN55032 Class B
continued on next page
www.recom-power.com
REV.: 4/2020
PA-13
C7
C6
C5
C11
C4
C12
C17
C14
C13
C19
C16
C15
C20
RP100H-RW
Shield Plane
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
RP100-110xxSRW, Class B
EMI Filtering according to EN55032/11 Class B (110Vin)
L1
Fuse
C1
L2
C3
C2
C4
C10
C11 C12
LOAD
+VIN
C15
Case
-VIN
C9
C5
C8
C7
C13 C14
C6
C16
C20
C19
C17
C22
C21
C18
Shield Plane
C1, C3, C10
RP100H-110xxSRW
+VIN
150µF, 200V
Fuse
Al
cap. (lie down)
Chemi-con KY
RP100H-11048SRW
C1
-VIN
RP100H-11005SRW
C2
C2 , C5,
C23, C24
C4, C11, C12
C6, C7, C8, C9, C13, C14,
C17, C18, C19, C20, C21, C22
N/A
1µF, 250V
1812 MLCC
1000pF, 5kV
1808 MLCC
C15, C16
C5
N/A
C6
C7
100pF/250VAC
C8
1808 MLCC
L2
1219µH
CMC
521µH
CMC
C11
L2
L1 C4, C11,
C2,
C8, C9, C13, C14, C17, C18 , C19,
2200pF
C5, C6, C7, C19
C12
C20, C21, C22, C23, C24
TDK CD series Y1
1µF/250V
C3
C4
1812 MLCC
L1
LOAD
RP100-24xxSRW, Class B
MODEL
RP100-48xxSRW, Class B
Case
Conducted Emission EN55032 Class B
C10
C15
C9
C12
C14
C13
Shield Plane
DIMENSIONS and PHYSICAL CHARACTERISTICS
Parameter
Material
Type
Value
case
24Vin, 48Vin
110Vin
Metal
Plastic
baseplate
24Vin, 48Vin
110Vin
FR4 PCB
Aluminium
potting
Silicone (UL94 V-0)
Dimensions (LxWxH)
without Heat-sink
with Heat-sink
61.0 x 57.9 x 12.7mm
61.0 x 57.9 x 24.13mm
Weight
without Heat-sink
with Heat-sink
105g
157g
continued on next page
www.recom-power.com
REV.: 4/2020
PA-14
RP100H-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
24Vout, 48Vout:
57.9
61.0
0.6
5.08
12.1
Dimension Drawing (mm)
24Vin, 48Vin
Ø2.0±0.1
Ø1.0±0.1
M3
12.7
4.8
5
3
6
Bottom View
7
2
8
1
9
FC 50.80
10.16
17.78
25.40
35.56
4
Pin Connections
Pin #
5.1
4xM3
FC 48.26
61.0
Ø2.0±0.1
Ø1.0±0.1
+Vin
2
CTRL
3
Case
4
-Vin
5
-Vout
6
-Sense
7
Trim
8
+Sense
9
+Vout
5.08
12.7
57.9
1
FC= Fixing Centers for Heat-sink
Pin Pitch Tolerance ±0.25mm
Pin Dimension Tolerance ±0.1mm
XX.X ± 0.5mm
XX.XX ± 0.25mm
110Vout:
110Vin
Single
M3
4
5
3
6
Bottom View
7
2
8
1
9
FC 50.80
10.16
17.78
25.40
35.56
12.7
4.8
5.1
4xM3
FC 48.26
continued on next page
www.recom-power.com
REV.: 4/2020
PA-15
RP100H-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
Dimension Drawing Heat-sink (mm)
57.9
Notes:
Note8: Max. tightening torque for Heat Sink: 0.34Nm
50.80
61.0
48.26
24.13
11.43
4xM3
Ø2.0±0.1
Ø1.0±0.1
PACKAGING INFORMATION
Parameter
Packaging Dimension
Type
tray
Value
without Heat-sink
with Heat-sink
Packaging Quantity
157.0 x 88.0 x 23.0mm
157.0 x 88.0 x 35.0mm
2pcs.
Storage Temperature Range
-55°C to +125°C
Storage Humidity
5% - 95% RH
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 4/2020
PA-16