RP100H-11048SRW/N

RP100H-11048SRW/N

  • 厂商:

    RECOM

  • 封装:

    -

  • 描述:

    CONVDC/DC101W43-160VIN48VOUT

  • 数据手册
  • 价格&库存
RP100H-11048SRW/N 数据手册
Features • 4:1 wide input range • 3kVAC reinforced insulation for 110Vin 2.25kVDC basic insulation for 24Vin & 48Vin • Efficiency up to 93% • No minimum load required • EN50155, IEC/EN60950-1 & UL60950-1 certified Regulated Converter Description DC/DC Converter RP100H-RW 100 Watt 3 Half Brick Single Output YEA R y arrant w The half-brick RP100H series DC/DC converters are designed for railway rolling stock and high voltage battery applications. Each series has three 4:1 input voltage range options to cover all input voltages from 9VDC up to 160VDC with isolated and regulated 5V to 48VDC outputs. The converters have high efficiencies and metal baseplates to permit a wide operating temperature range from -40°C to +85°C (when mounted on a suitable heatsink). The case is fitted with threaded inserts to allow secure mounting to the PCB or bulkhead for use in high shock and vibration environments. The converters are EN50155, UL60950 and IEC/EN60950 certified. The RP100H-RW series have a three year warranty. T CONVER T S S RE M R R C TS compliant PL U D IA N T PRO CO 10 from 10 O REACH compliant M C M TS CONVER C M E O E C RoHS 2 + CO Part Number Input Output Output Input(1) Output Efficiency(1) Max. Capacitive Voltage Range Voltage Current Current Power typ. Load [VDC] [VDC] [mA] [mA] [W] [%] [µF] RP100H-2405SRW 9-36 5 20000 4480 100 93 40000 7000 RP100H-2412SRW 9-36 12 8400 4666 101 90 RP100H-2415SRW 9-36 15 6700 4601 100 91 4460 RP100H-2424SRW 9-36 24 4200 4666 101 90 1750 430 RP100H-2448SRW 9-36 48 2100 4666 101 90 RP100H-4805SRW 16.5-75 5 20000 2240 100 93 40000 RP100H-4812SRW 16.5-75 12 8400 2333 101 90 7000 RP100H-4815SRW 16.5-75 15 6700 2300 100 91 4460 1750 RP100H-4824SRW 16.5-75 24 4200 2333 101 90 430 RP100H-4848SRW 16.5-75 48 2100 2307 101 90 RP100H-11005SRW 43-160 5 20000 1010 100 93 40000 RP100H-11012SRW 43-160 12 8400 1018 101 90 7000 RP100H-11015SRW 43-160 15 6700 1015 100 91 4460 RP100H-11024SRW 43-160 24 4200 1018 101 90 1750 48 2100 1007 101 90 430 RP100H-11048SRW 43-160 RE Selection Guide PL U D IA N T PRO E196683 EN50155 certified IEC/EN60950-1 certified UL60950-1 certified Notes: Note1: Efficiency is tested by nominal Vin, full load and at 25°C Model Numbering REF DESIGN available RP100H-__ __ SRW/_ _ Input Voltage Output Voltage Package(3) CTRL Logic(2) https://recom-power.com/rec-s-RREF04-RIA12.html Single Notes: Note2: Note3: standard part is with suffix “P” for positive logic (1=ON, 0=OFF) or add suffix “N” instead for negative logic (0=ON, 1=OFF) for more details refer to “ON/OFF CTRL (4)” add suffix “-HC” for premounted Heat-sink (refer to “Dimension Drawing Heat-sink (mm)”) (compatible with all other suffixes) Ordering Examples RP100H-2405SRW/N = 24V Input, 5V Output, Single, Neg. CTRL function RP100H-11012SRW/P = 110V Input, 12V Output, Single, Pos. CTRL function RP100H-2405SRW/N-HC = 24V Input, 5V Output, Single, Neg. CTRL function, premounted Heat-sink www.recom-power.com REV.: 4/2020 SURGE PROTECTOR available https://recom-power.com/rec-sRSPxxx-168.html PA-1 RP100H-RW DC/DC Converter Series Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted) BASIC CHARACTERISTICS Parameter Condition Min. Typ. nom Vin = 24V nom Vin = 48V nom Vin = 110V Vin = 24V, 1s max. Vin = 48V, 1s max. Vin = 110V, 1s max. 9VDC 16.5VDC 43VDC 24VDC 48VDC 110VDC Max. Internal Input Filter Vin = 24V DC-DC ON DC-DC OFF 7.3VDC Pi-Type 36VDC 75VDC 160VDC 50VDC 100VDC 185VDC 9VDC 8.1VDC Vin = 48V DC-DC ON DC-DC OFF 15.5VDC 18VDC 16.3VDC Vin = 110V DC-DC ON DC-DC OFF 33.0VDC 25mA 15mA 43VDC 36.0VDC 35mA 25mA Input Voltage Range Input Surge Voltage Under Voltage Lockout (UVLO) Vin = 24V Vin = 48V Vin = 110V refer to “OUTPUT VOLTAGE TRIMMING” Quiescent Current Output Voltage Trimming 10mA -20% Minimum Load +10% 0% Power up Remote ON/OFF Start-up time 75ms 75ms Positive Logic DC-DC ON DC-DC OFF Open or 3.0VDC < VCTRL < 12VDC Short or 0VDC < VCTRL < 1.2VDC Negative Logic DC-DC ON DC-DC OFF Short or 0VDC < VCTRL < 1.2VDC Open or 3.0VDC < VCTRL < 12VDC Input Current of CTRL pin drive current ICTRL Standby Current DC-DC OFF IIn ON/OFF CTRL (4) refer to “ON/OFF CTRL” -0.5mA 3mA Vin = 24V, Vin =48V Vin = 110V Internal Operating Frequency 1mA 225kHz 270kHz 250kHz 300kHz 75mVp-p 100mVp-p 200mVp-p 300mVp-p with a 1µF/25V X7R MLCC & a 22µF/25V POS Cap 5 Vout Measured by with a 1µF/25V X7R MLCC & a 22µF/25V POS Cap 12, 15Vout 20MHz BW with a 4.7µF/50V X7R MLCC 24Vout with a 2.2µF/100V X7R MLCC 48Vout Output Ripple and Noise 275kHz 330kHz % of nom Vout (refer to “REMOTE SENSE”) Remote Sense 10% Notes: Note4: The ON/OFF control function can be positive or negative logic. The pin voltage is referenced to -Vin RP100H-2405SRW Efficiency vs. Output Current 90 90 80 80 70 60 50 40 30 10 70 60 50 40 100% Load 50% Load 25% Load 30 9Vin 24Vin 36Vin 20 0 Efficiency vs. Input Voltage 100 Efficiency [%] Efficiency [%] 100 20 10 10 20 30 40 50 60 70 Output Current [%] www.recom-power.com 80 90 100 continued on next page REV.: 4/2020 9 12 15 18 21 24 27 30 33 36 Input Voltage [V] PA-2 RP100H-RW DC/DC Converter Series Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted) RP100H-2405SRW Power Dissipation [W] Typical Output Ripple and Noise/full load Power Dissipation vs. Output Current 18 15 12 9 6 9Vin 24Vin 36Vin 3 0 10 20 30 40 50 60 70 80 90 100 Output Current [%] ON/OFF Control Start-up Rise Characteristic Power up Start-up Characteristic RP100H-4805SRW Efficiency vs. Output Current 90 90 80 80 70 60 50 40 30 16.5Vin 48Vin 75Vin 20 10 0 10 20 30 40 50 60 70 Output Current [%] www.recom-power.com Efficiency vs. Input Voltage 100 Efficiency [%] Efficiency [%] 100 80 90 70 60 50 40 100% Load 50% Load 25% Load 30 20 100 10 16.5 continued on next page REV.: 4/2020 24 30 36 42 48 54 60 66 72 75 Input Voltage [V] PA-3 RP100H-RW DC/DC Converter Series Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted) RP100H-4805SRW Power Dissipation vs. Output Current 18 Typical Output Ripple and Noise/full load Power Dissipation [W] 15 12 9 6 16.5Vin 48Vin 75Vin 3 0 10 20 30 40 50 60 70 80 90 100 Output Current [%] ON/OFF Control Start-up Rise Characteristic Power up Start-up Characteristic RP100H-11005SRW Efficiency vs. Output Current 90 90 80 80 70 60 50 40 30 10 70 60 50 40 20 10 10 20 30 40 50 60 70 80 90 100% Load 50% Load 25% Load 30 43Vin 110Vin 160Vin 20 0 Efficiency vs. Input Voltage 100 Efficiency [%] Efficiency [%] 100 100 43 60 65 80 95 110 125 140 155 160 Input Voltage [V] Output Current [%] continued on next page www.recom-power.com REV.: 4/2020 PA-4 RP100H-RW DC/DC Converter Series Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted) RP100H-11005SRW Power Dissipation vs. Output Current Typical Output Ripple and Noise Power Dissipation [W] 18 15 12 9 6 43Vin 110Vin 160Vin 3 0 10 20 30 40 50 60 70 80 90 100 Output Current [%] ON/OFF Control Start-up Rise Characteristic Power up Start-up Characteristic ON/OFF CTRL +Vin VCTRL -Vin IIN ICTRL +Vin +Vout +Vout Positve Logic DC-DC ON DC-DC OFF Open or 3.0VDC < VCTRL < 12VDC Short or 0VDC < VCTRL < 1.2VDC Negativ Logic DC-DC ON DC-DC OFF Short or 0VDC < VCTRL < 1.2VDC Open or 3.0VDC < VCTRL < 12VDC CTRL -Vin -Vout -Vout REMOTE SENSE +Vin RW1 +Vout +Sense R1 Load Trim R2 -Sense -Vin www.recom-power.com -Vout (GND) RW2 The output voltage can be adjusted by both trim and remote sense. The maximum combined adjustment range ±10%. Derate the maximum output power if using the trim or sense function. RW1 ... wire losses + RW2 ... wire losses R1 ... trim up resistor R2 ... trim down resistor REV.: 4/2020 PA-5 RP100H-RW DC/DC Converter Series Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted) OUTPUT VOLTAGE TRIMMING Output Voltage Trimming RP100H-RW converters offer the feature of trimming the output voltage over a certain range around the nominal value by using external trim resistors. The values for trim resistors shown in trim tables below are according to standard E96 values; therefore, the specified voltage may slightly vary; they also can be calculated with below shown equation. TRIM UP TRIM DOWN TRIM -Sense R1 R2 +Sense TRIM Trim Calculation R1 = 100*Vout+DVout * Vout) R2 = - 1.225*DVout 100 DVout - 2 kΩ (100+2DVout) DVout kΩ Vout = Output Voltage DVout = Output Voltage Trim in % R1 = trim up resistor R2 = trim down resistor Practical Example: Trim Up: Vout = 5V, DVout = 10% (5.5V) R1 = 100*Vout+DVout * Vout) (100+2DVout) - 1.225*DVout DVout kΩ = 100*5 +10*5 1.225*10 - 100+2*10 10 = 44.89 - 12 = 32.9kΩ Trim down: Vout = 5V, DVout = -10% (4.5V) R2 = 100 DVout - 2 kΩ = 100 10 - 2 = 8.06kΩ RP100H-xx05SRW Trim up 1 2 3 4 5 6 7 8 9 10 % Vout = 5.05 5.10 5.15 5.20 5.25 5.30 5.35 5.4 5.45 5.50 Volts R1 = 309 158 105 78.7 63.4 53.6 46.4 40.2 36.5 33.2 kOhms RP100H-xx12SRW Trim up 1 2 3 4 5 6 7 8 9 10 Vout = 12.12 12.24 12.36 12.48 12.60 12.72 12.84 12.96 13.08 13.20 Volts 887 453 301 226 182 154 133 118 105 95.3 kOhms R1 = % RP100H-xx15SRW Trim up 1 2 3 4 5 6 7 8 9 10 Vout = 15.15 15.30 15.45 15.60 15.75 15.90 16.05 16.20 16.35 16.50 R1 = 1130 576 383 294 237 196 169 150 137 124 % Volts kOhms continued on next page www.recom-power.com REV.: 4/2020 PA-6 RP100H-RW DC/DC Converter Series Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted) OUTPUT VOLTAGE TRIMMING RP100H-xx24SRW Trim up 1 2 3 4 5 6 7 8 9 10 % Vout = 24.24 24.48 24.72 24.96 25.20 25.44 25.68 25.92 26.16 26.40 RU = 1870 953 634 487 392 324 280 249 226 205 kOhms % Volts RP100H-xx48SRW Trim up 1 2 3 4 5 6 7 8 9 10 Vout = 48.48 48.96 49.44 49.92 50.40 50.88 51.36 51.84 52.32 52.80 R1 = 3830 1960 1300 1000 806 681 576 511 464 422 kOhms 1 2 3 4 5 6 7 8 9 10 % 97.6 47.5 31.6 23.2 17.8 14.7 12.1 10.5 9.09 8.06 Volts Trim Down all Vout‘s Trim down R2 = Trim down R2 = 11 12 13 14 15 16 17 18 19 20 7.15 6.34 5.76 5.11 4.64 4.22 3.92 3.57 3.24 3.01 kOhms % kOhms REGULATIONS Parameter Condition Value Output Accuracy ±1.0% Line Regulation low line to high line at full load Load Regulation 0% to 100% load Transient Response ±0.1% 0.1% 25% load step change 200µs typ.; 250μs max. Transient Response to Dynamic Load Change from 100% to 75% to 100% of Full Load at nom.Vin RP100H-2405SRW RP100H-4805SRW continued on next page www.recom-power.com REV.: 4/2020 PA-7 RP100H-RW DC/DC Converter Series Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted) RP100H-11005SRW PROTECTIONS Parameter Condition Value Short Circuit Protection (SCP) below 100mΩ continuous, automatic recovery Over Voltage Protection (OVP) % of nom. Vout 115%-130%, Hiccup Mode Over Load Protection (OLP) 24Vin, 48Vin 110Vin % Iout rated Over Temperature Protection (OTP) +110°C to +120°C 110Vin I/P to O/P I/P or O/P to Case 3kVAC/1minute 1.5kVAC/1minute 24Vin, 48Vin I/P to O/P I/P or O/P to Case 2.25kVDC/1minute 1.6kVDC/1minute Isolation Voltage Isolation Resistance 120%-150%, Hiccup Mode 150% typ., Hiccup Mode 500 VDC 1GΩ min. Isolation Capacitance 2500pF max. 110 Vin 24Vin, 48Vin Isolation Grade reinforced insulation basic insulation Notes: Note5: Refer to local wiring regulations if input over-current protection is also required. Recommended fuse: T35A slow blow. ENVIRONMENTAL Parameter Condition Operating Case Temperature Range Maximum Case Temperature 105°C Temperature Coefficient Thermal Impedance ±0.02%/°C max. vertical direction by natural convection (0.1m/s) without Heat-sink vertical direction by natural convection (0.1m/s) with Heat-sink Operating Humidity 6.7°C/W 4.7°C/W 5% - 95% RH Pollution Degree PD2 Shock according to EN61373 standard Thermal Shock according to MIL-STD-810F standard Vibration according to EN61373 standard Fire protection on railway vehicles MTBF Value refer to derating graph according to EN45545-2, 2013 standard according to MIL-HDBK-217F standard, 25°C 408.7 x 103 hours continued on next page www.recom-power.com REV.: 4/2020 PA-8 RP100H-RW DC/DC Converter Series Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted) Thermal Calculation Rthcase-ambient = 6.7°C/W (vertical) Tcase = Case Temperature Rthcase-ambientHC = 4.7°C/W (vertical) Tambient = Environment Temperature Pdissipation = Internal losses T -T Rthcase-ambient =  case ambient PIN = Input Power Pdissipation POUT = Output Power h = Efficiency under given Operating Conditions P Pdissipation = PIN - POUT =  OUTapp P R = Thermal Impedance OUTapp thcase-ambient h Practical Example: Take the RP100H-2405SRW with 9V input Voltage and 50% load. What is the maximum ambient operating temperature? Use converter vertical in application without airflow. Effmin = 91% @ Vnom without Heat-sink with Heat-sink POUT = 100W T 105-Tamb T 105-Tamb -T -T Rth = casemax amb --> 6.7°C/W = RthHC = casemax amb --> 4.7°C/W = POUTapp = 100 x 0.5 = 50W 4.95W Pdissipation Pdissipation 4.95W h = 91% (Efficiency vs. Load Graph) Tamb = 72°C TambHC = 82°C 50 Pdissipation = - 50 = 4.95W 0.91 Derating Graph(6) (@ Chamber - tested with forced convection) RP100H-2405SRW-HC 100 100 80 80 Output Power [%] Output Power [%] RP100H-2405SRW 60 40 0.5m/s 1m/s 1.5m/s 2m/s 2.5m/s 20 0 -40 -20 0 60 40 natural convection 0.5m/s 1m/s 1.5m/s 2m/s 2.5m/s 20 20 40 60 80 0 -40 100 120 Ambient Temperature [°C] -20 80 80 Output Power [%] Output Power [%] 100 60 0 -40 0.5m/s 1m/s 1.5m/s 2m/s 2.5m/s -20 0 40 60 60 67 80 100 120 60 40 natural convection 0.5m/s 1m/s 1.5m/s 2m/s 2.5m/s 20 20 40 RP100H-4805SRW-HC 100 20 20 Ambient Temperature [°C] RP100H-4805SRW 40 0 65 80 0 -40 100 120 -20 0 20 40 60 71 80 100 120 Ambient Temperature [°C] Ambient Temperature [°C] continued on next page www.recom-power.com REV.: 4/2020 PA-9 RP100H-RW DC/DC Converter Series Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted) RP100H-11005SRW RP100H-11005SRW-HC 80 80 Output Power [%] 100 Output Power [%] 100 60 40 0.5m/s 1m/s 1.5m/s 2m/s 2.5m/s 20 0 -40 -20 0 60 40 natural convection 0.5m/s 1m/s 1.5m/s 2m/s 2.5m/s 20 20 40 60 80 0 -40 100 120 Ambient Temperature [°C] -20 0 20 40 50 60 80 100 120 Ambient Temperature [°C] Notes: Note6: Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part- number not shown here please contact our technical support service at techsupportAT@recom-power.com SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Information Technology Equipment, General Requirements for Safety E196683 Information Technology Equipment - General Requirments for Safety TW1608033-001, TW1608036-001, TW1608037-001, TW1608079-001 Standard UL60950-1, 2nd Edition, 2014 CSA C22.2 No. 60950-1-07, 2nd Edition, 2014 IEC60950-1, 2nd Edition. 2005 EN60950-1, 2006 Railway Applications - Electrical Equipment used on rolling stock 16A081501E-C EN50155, 2007 EAC RU-AT.49.09571 TP TC 004/2011 RoHS2+ RoHS 2011/65/EU EMI Compliance Condition Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement Industrial, scientific and medical equipment - Radio frequency disturbance characteristics - Limits and methods of measurement www.recom-power.com EN55032, Class A and Class B with external components EN55011, Class A and Class B ESD Electrostatic discharge immunity test Radiated, radio-frequency, electromagnetic field immunity test Fast Transient and Burst Immunity(7) Surge Immunity(7) Immunity to conducted disturbances, induced by radio-frequency fields Power Magnetic Field Immunity Notes: Note7: Standard / Criterion Air ±8kV and Contact ±6kV 20 V/m ±2kV ±2kV 10 Vr.m.s 100A/m continuous; 1000A/m 1s EN61000-4-2, Criteria A EN61000-4-3, Criteria A EN61000-4-4, Criteria A EN61000-4-5, Criteria A EN61000-4-6, Criteria A EN61000-4-8, Criteria A An external input filter capacitor is required if the module has to meet EN61000-4-4 and EN61000-4-5. The 24Vin and 48Vin version recommend 2pcs of aluminium elecrolytic capacitor to connect in parallel. Recom suggest: Nippon Chemi-con KY series, 220µF/100V. The 110Vin version recommend 2pcs of aluminium electrolytic capacitor to connect in parallel. Recom suggest: Nippon Chemi-con KXJ series, 150µF/200V continued on next page REV.: 4/2020 PA-10 RP100H-RW DC/DC Converter Series Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted) RP100-24xxSRW, Class A RP100-48xxSRW, Class A EMI Filtering according to EN55032/11 Class A and EN50121-1 (24Vin and 48Vin) C10 L1 C1 C2 C3 C4 C5 C7 C6 LOAD Fuse +VIN Case -VIN C9 C8 C12 C13 C11 Shield Plane RP100-110xxSRW, Class AMODEL C1, C2, C4 C8, C9, C10, C11, C13 C12 L1 C18 RP100H-24xxSRW 470µF, 50V Al cap. L1 (lie down) Chemi-con KY 4.7µF, 50V 1812 MLCC 1000pF, 3kV 1808 MLCC 3300pF, 3kV 1808 MLCC 156µH CMC RP100H-48xxSRW 220µF, 100V Al cap. (lie down) Chemi-con KY 2.2µF, 100V 1812 MLCC 1000pF, 3kV 1808 MLCC 1000pF, 3kV 1808 MLCC 224µH CMC C1 C2 C3 C8 C9 C10 LOAD Fuse +VIN C3, C6, C7 Case RP100H-2405SRW Conducted Emission EN55032 Class A -VIN C7 C6 C5 C11 C4 C12 C13 C17 C14 C19 C16 C15 C20 Shield Plane RP100-110xxSRW, Class B C15 L1 Fuse L2 C3 C1 C2 RP100H-4805SRW C4 C10 C11 C12 LOAD +VIN Conducted Emission EN55032 Class A Case -VIN C9 C5 C8 C7 C13 C14 C6 C19 C16 C20 C21 C22 C17 C18 Shield Plane RP100-24xxSRW, Class B RP100-48xxSRW, Class B C11 C1 www.recom-power.com -VIN L2 L1 Fuse C2 C3 C4 C5 continued on next page C6 C7 REV.: 4/2020 C8 Case LOAD +VIN PA-11 C1 C2 C3 C4 C5 C7 C6 LOAD IN RP100H-RW Case -VIN DC/DC Converter C9 C8 C12 Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted) EMI Filtering according to EN55032/11 Class A and EN50121-1 (110Vin) C11 Series C13 Shield Plane RP100-110xxSRW, Class A C18 L1 C1 C2 C3 C8 C9 C10 LOAD Fuse +VIN Case -VIN C7 C6 C5 C11 C4 C12 C13 C17 C14 C19 C16 C15 C20 Shield Plane C1, C2, C8 RP100H-110xxSRW +VIN L1 Fuse C1 C10 C6, C11, C12, C13, C14, C15, C16, C19, C20 C17, C18 L1 1000pF, 5kV 1808 MLCC 2200pFC15 TDK CD series Y1 1219µH CMC 100µF, 250V 1µF, 250V Al cap. (lie down) Rubycon BXF 1812 MLCC L2 C3 C2 C4 C10 C11 C12 LOAD RP100-110xxSRW,MODEL Class B Case -VIN C9 C5 C8 C7 C13 C14 C6 C16 C20 C19 C21 C17 C22 RP100H-11005SRW Conducted Emission EN55032 Class A Shield Plane RP100-24xxSRW, Class B RP100-48xxSRW, Class B C11 L2 L1 Fuse C1 C2 C3 C4 C5 C6 C7 C8 LOAD +VIN Case -VIN C10 C15 continued on next page www.recom-power.com REV.: 4/2020 C9 C12 C14 C13 Shield Plane PA-12 C18 N C9 C5 C8 C7 C13 C14 C6 C16 C20 C19 C18 C17 C22 C21 RP100H-RW DC/DC Converter Series Shield Plane -24xxSRW, Class B Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted) -48xxSRW, Class B EMI Filtering according to EN55032/11 Class B (24Vin and 48Vin) L2 L1 Fuse C1 C3 C2 C4 C5 C6 C7 C8 LOAD +VIN C11 Case -VIN C10 C15 C9 C12 C14 C13 Shield Plane MODEL C1, C3, C6 C2, C4, C5, C7, C8 C9, C10 C11 470µF, 50V 4.7µF, 50V 10nF, 2kV 1000pF, 3kV Al cap. (lie down) Chemi-con KY 1812 MLCC 1812 MLCC 1808 MLCC 220µF, 100V 2.2µF, 100V 10nF, 100V 2200pF, 3kV RP100H-48xxSRW Al cap. (lie down) Chemi-con KY 1812 MLCC 1812 MLCC 1808 MLCC RP100H-24xxSRW RP100H-2405SRW RP100H-4805SRW C12 C13, C14 C15 4700pF, 3kV 10nF, 2kV N/A 1812 MLCC 1812 MLCC 4700pf, 3kV 10nF, 2kV 1000pF, 3kV 1812 MLCC 1812 MLCC 1808 MLCC L1 156µH CMC 224µH CMC Conducted Emission EN55032 Class B Conducted Emission EN55032 Class B continued on next page www.recom-power.com REV.: 4/2020 PA-13 C7 C6 C5 C11 C4 C12 C17 C14 C13 C19 C16 C15 C20 RP100H-RW Shield Plane DC/DC Converter Series Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted) RP100-110xxSRW, Class B EMI Filtering according to EN55032/11 Class B (110Vin) L1 Fuse C1 L2 C3 C2 C4 C10 C11 C12 LOAD +VIN C15 Case -VIN C9 C5 C8 C7 C13 C14 C6 C16 C20 C19 C17 C22 C21 C18 Shield Plane C1, C3, C10 RP100H-110xxSRW +VIN 150µF, 200V Fuse Al cap. (lie down) Chemi-con KY RP100H-11048SRW C1 -VIN RP100H-11005SRW C2 C2 , C5, C23, C24 C4, C11, C12 C6, C7, C8, C9, C13, C14, C17, C18, C19, C20, C21, C22 N/A 1µF, 250V 1812 MLCC 1000pF, 5kV 1808 MLCC C15, C16 C5 N/A C6 C7 100pF/250VAC C8 1808 MLCC L2 1219µH CMC 521µH CMC C11 L2 L1 C4, C11, C2, C8, C9, C13, C14, C17, C18 , C19, 2200pF C5, C6, C7, C19 C12 C20, C21, C22, C23, C24 TDK CD series Y1 1µF/250V C3 C4 1812 MLCC L1 LOAD RP100-24xxSRW, Class B MODEL RP100-48xxSRW, Class B Case Conducted Emission EN55032 Class B C10 C15 C9 C12 C14 C13 Shield Plane DIMENSIONS and PHYSICAL CHARACTERISTICS Parameter Material Type Value case 24Vin, 48Vin 110Vin Metal Plastic baseplate 24Vin, 48Vin 110Vin FR4 PCB Aluminium potting Silicone (UL94 V-0) Dimensions (LxWxH) without Heat-sink with Heat-sink 61.0 x 57.9 x 12.7mm 61.0 x 57.9 x 24.13mm Weight without Heat-sink with Heat-sink 105g 157g continued on next page www.recom-power.com REV.: 4/2020 PA-14 RP100H-RW DC/DC Converter Series Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted) 24Vout, 48Vout: 57.9 61.0 0.6 5.08 12.1 Dimension Drawing (mm) 24Vin, 48Vin Ø2.0±0.1 Ø1.0±0.1 M3 12.7 4.8 5 3 6 Bottom View 7 2 8 1 9 FC 50.80 10.16 17.78 25.40 35.56 4 Pin Connections Pin # 5.1 4xM3 FC 48.26 61.0 Ø2.0±0.1 Ø1.0±0.1 +Vin 2 CTRL 3 Case 4 -Vin 5 -Vout 6 -Sense 7 Trim 8 +Sense 9 +Vout 5.08 12.7 57.9 1 FC= Fixing Centers for Heat-sink Pin Pitch Tolerance ±0.25mm Pin Dimension Tolerance ±0.1mm XX.X ± 0.5mm XX.XX ± 0.25mm 110Vout: 110Vin Single M3 4 5 3 6 Bottom View 7 2 8 1 9 FC 50.80 10.16 17.78 25.40 35.56 12.7 4.8 5.1 4xM3 FC 48.26 continued on next page www.recom-power.com REV.: 4/2020 PA-15 RP100H-RW DC/DC Converter Series Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted) Dimension Drawing Heat-sink (mm) 57.9 Notes: Note8: Max. tightening torque for Heat Sink: 0.34Nm 50.80 61.0 48.26 24.13 11.43 4xM3 Ø2.0±0.1 Ø1.0±0.1 PACKAGING INFORMATION Parameter Packaging Dimension Type tray Value without Heat-sink with Heat-sink Packaging Quantity 157.0 x 88.0 x 23.0mm 157.0 x 88.0 x 35.0mm 2pcs. Storage Temperature Range -55°C to +125°C Storage Humidity 5% - 95% RH The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV.: 4/2020 PA-16
RP100H-11048SRW/N 价格&库存

很抱歉,暂时无法提供与“RP100H-11048SRW/N”相匹配的价格&库存,您可以联系我们找货

免费人工找货
RP100H-11048SRW/N
    •  国内价格
    • 1+1547.53364

    库存:4