Features
•
•
•
•
•
•
Regulated
Converter
2:1 input voltage range
1.6kVDC isolation
UL certified
Efficiency up to 88%
Over current protection
No minimum load required
DC/DC Converter
RP12-A
12 Watt
3
DIP24/SMD
Single and Dual
Output
Description
YEA R
The RP12-A series DC/DC converters are certified to UL 60950-1 and cUL 60950-1. This makes
them ideal for all telecom and industrial applications where approved safety standards are required.
The DIP24 package is available in both pinned and SMD case styles and meets military standards for
thermal shock and vibration tolerance.
y
w
arrant
T
M
CONVER
T
E
S
S
R
R
C
TS
compliant
PL
U
D
IA N
T PRO
CO
10 from 10
O
REACH
compliant
M
C
M
TS
CONVER
C
M
RE
O
E
C
RoHS 2 +
CO
Notes:
Note1: Maximum values at nominal input voltage and full load
Note2: Max. Cap load is tested at minimum Input and constant resistive load
RE
Selection Guide
Part Number
Input
Output
Output
Input (1) Efficiency (1) Max. Capacitive
Voltage Range Voltage
Current
Current
typ.
Load (2)
[VDC] [VDC] [mA] [mA] [%]
[µF]
RP12-123.3SA (3)
9-18
3.3
3500
1146
84
2000
RP12-1205SA (3)
9-18 5.1 2400 1163 86
2000
RP12-1212SA (3)
9-18 12 1000 1163 86
430
RP12-1215SA (3) 9-18 15 800 1163 86
300
RP12-243.3SA (3) 18-36 3.3 3500 566 85
2000
RP12-2405SA (3)
18-36
5.1
2400
586
87
2000
RP12-2412SA (3) 18-36 12 1000 575 87
430
RP12-2415SA (3) 18-36 15 800 575 87
300
RP12-483.3SA (3) 36-75 3.3 3500 283 85
2000
RP12-4805SA (3) 36-75 5.1 2400 293 87
2000
RP12-4812SA (3) 36-75 12 1000 287 87
430
RP12-4815SA (3) 36-75 15 800 287 87
300
RP12-1205DA (3)
9-18
±5 ±1200 1220 82
±1250
RP12-1212DA (3)
9-18 ±12 ±500 1149 87
±200
RP12-1215DA (3)
9-18 ±15 ±400 1149 87
±120
RP12-2405DA (3) 18-36 ±5 ±1200 602 83
±1250
RP12-2412DA (3) 18-36 ±12 ±500 568 88
±200
RP12-2415DA (3) 18-36 ±15 ±400 568 88
±120
RP12-4805DA (3)
36-75
±5
±1200
301
83
±1250
RP12-4812DA (3)
36-75
±12
±500
284
88
±200
RP12-4815DA (3)
36-75
±15
±400
284
88
±120
PL
U
D
IA N
T PRO
E196683
UL60950-1 certified
Model Numbering
RP12-__ __ _A/_
nom. Input Voltage
“Package (3)”
Output Voltage
Single or Dual
Notes:
Note3: no suffix for standard package (DIP24)
add suffix “/SMD” for SMD package
Ordering Examples
RP12-4805SA/SMD = 48V input, 5V output, single, SMD package
RP12-1205DA = 12V input, 5V output, dual, DIP24 package
www.recom-power.com
REV.: 3/2020
PD-1
RP12-A
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
nom. Vin = 12VDC
nom. Vin = 24VDC
nom. Vin = 48VDC
9VDVC
18VDC
36VDC
12VDC
24VDC
48VDC
Max.
Input Filter
Input Voltage Range
nom. Vin = 12VDC
nom. Vin = 24VDC
nom. Vin = 48VDC
DC-DC ON
DC-DC OFF
8VDC
nom. Vin = 24VDC
DC-DC ON
DC-DC OFF
16VDC
nom. Vin = 48VDC
DC-DC ON
DC-DC OFF
33VDC
Input Surge Voltage
100ms max.
nom. Vin = 12VDC
Under Voltage Lockout (UVLO)
18VDC
36VDC
Input Reflected Ripple Current (4)
20mAp-p
Power up
ON/OFF CTRL
Start-up time
450ms
5ms
Operating Frequency Range
Minimum Load
Pi-Type
18VDC
36VDC
75VDC
36VDC
50VDC
100VDC
9VDC
360kHz
400kHz
440kHz
10%
(5)
DC-DC ON
DC-DC OFF
Positive Logic
ON/OFF CTRL (6)
Open or 3.0VDC < VCTRL < 12VDC
Short or 0VDC < VCTRL < 1.2VDC
-0.5mA
+0.5mA
DC-DC ON
Input Current of CTRL pin
Standby Current
DC-DC OFF
2.5mA
Ripple and Noise
20MHz BW, with 1μF MLCC on output
85mVp-p
Notes:
Note4: Simulated source impedance of 12μH. 12μH inductor in series with +Vin
Note5: The RP12 series requires a minimum of 10% loading on the output to maintain specified regulation
Operation under no-load condition will not damage these devices, however they may not meet all listed specification
Note6: The pin voltage is referenced to -Vin pin
RP12-1205SA
Efficiency vs. Output Current
95
Efficiency vs. Input Voltage
95
90
90
80
Efficiency [%]
Efficiency [%]
85
75
70
65
60
55
9Vin
12Vin
18Vin
50
45
40
10
20
30
40
50
60
70
80
85
80
75
70
90
100
65
9
10
11
12
13
14
15
16
17
18
Input Voltage [VDC]
Output Current [%]
continued on next page
www.recom-power.com
REV.: 3/2020
PD-2
RP12-A
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
RP12-2405SA
Efficiency vs. Output Current
95
Efficiency vs. Input Voltage
90
90
85
80
80
Efficiency [%]
Efficiency [%]
85
75
70
65
60
55
75
70
18Vin
24Vin
36Vin
50
45
65
40
60
10
20
30
40
50
60
70
80
90
100
9
10
11
12
13
14
15
16
17
18
66
72
75
Input Voltage [VDC]
Output Current [%]
RP12-4805SA
Efficiency vs. Output Current
95
Efficiency vs. Input Voltage
95
90
90
80
75
70
65
60
55
80
75
36Vin
48Vin
75Vin
50
45
40
85
Efficiency [%]
Efficiency [%]
85
70
65
10
20
30
40
50
60
70
80
90
100
36
40
44
48
52
56
60
Input Voltage [VDC]
Output Current [%]
REGULATIONS
Parameter
Condition
Value
Output Accuracy
Line Regulation
Load Regulation
Cross Regulation
Transient Response Recovery Time
www.recom-power.com
±1.2%
low line to high line,
full load
Single
Dual
±0.2%
±0.5%
Single (0% to 100% load)
DIP24
SMD
±0.5%
±1.0%
Dual (0% to 100% load)
DIP24, SMD
±1.0%
asymmetrical 25%100% load
±5.0%
25% load step change
250μs
REV.: 3/2020
PD-3
RP12-A
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
PROTECTIONS
Parameter
Condition
Value
Short Circuit Protection (SCP)
continuous, automatic recovery
Over Voltage Protection (OVP)
zener diode clamp
Over Load Protection (OLP)
3.9VDC
6.2VDC
15VDC
18VDC
3.3Vout
5.1Vout
12Vout
15Vout
% of Iout rated
Isolation Voltage (7)
150% typ.
DIP24
I/P to O/P; I/P (O/P) to case
1.6kVDC/1 minute
SMD
I/P to O/P
I/P (O/P) to case
1.6kVDC/1 minute
1.0kVDC/1 minute
Isolation Resistance
Viso= 500VDC
1GΩ min.
Isolation Capacitance
1200pF max.
Notes:
Note7: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note8: This power module is not internally fused. An input line fuse must always be used
ENVIRONMENTAL
Parameter
Condition
Value
3.3Vout, ±5Vout
without derating
with derating
-40°C to +65°C
-40°C to +100°C
all others
without derating
with derating
-40°C to +72°C
-40°C to +100°C
Operating Temperature Range
Maximum Case Temperature
+100°C
Temperature Coefficient
±0.02%/K max.
Thermal Impedance
@ natural convection 0.1m/s
20K/W typ.
Operating Altitude
4000m
Operating Humidity
non-condensing
5% - 95% RH
Pollution Degree
PD2
Shock
according to MIL-STD-810F
Vibration
according to MIL-STD-810F
2064 x 103 hours
2750 x 10³ hours
MIL-HDBK-217F, G.B.
BELLCORE TR-NWT-000332 (9)
MTBF
Derating Graph (10)
RP12-4815SA
Output Power [%]
100
80
60
40
20
0
-40
-20
0
20
40
60
72
80
100
Ambient Temperature [°C]
Notes:
Note9: BELLCORE TR-NWT-000332. Case l: 50% Stress, Temperature at 40°C (Ground fixed and controlled environment)
Note10: Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-number
not shown here please contact RECOM Techsupport for detailed information
www.recom-power.com
REV.: 3/2020
PD-4
RP12-A
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Condition
Information Technology Equipment, General Requirements for Safety
Standard
UL60950-1, 2nd Edition, 2014
C22.2 No. 60950-1-07, 2nd Edition, 2014
E196683
EAC
AT.AB49.B.09571
TP TC 004/2011
RoHS 2
RoHS-2011/65/EU + AM-2015/863
EMC Compliance
Condition
Standard / Criterion
Electromagnetic compatibility of multimedia equipment - Emission
requirements
with external filter
(see filter suggestion below)
EN55032, Class A and B
ESD Electrostatic discharge immunity test
Air ±8kV and Contact ±6kV
EN61000-4-2, Criteria A
10 V/m
EN61000-4-3, Criteria A
±2kV
EN61000-4-4, Criteria A
±1kV
EN61000-4-5, Criteria A
10 Vr.m.s
EN61000-4-6, Criteria A
100A/m continuous; 1000A/m 1s
EN61000-4-8, Criteria A
Radiated, radio-frequency, electromagnetic field immunity test
Fast Transient and Burst Immunity
(11)
Surge Immunity (11)
Immunity to conducted disturbances, induced by radio-frequency fields
Power Magnetic Field Immunity
Notes:
Note11: An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5
Recom suggests Nippon chemi-con KY series 220μF/100V
EMC Filtering Suggestions according to EN55032
Single
Dual
C2
C2
F1
+Vin
+Vin
+Vout
+Vout
+Vin
F1
+Vin
C1
C1
C2
-Vin
-Vin
+Vin
Component List Class A
C3
+Vout
+Vin
-Vin
+Vout
+Vin
-Vin
+Vin
-Vin
C1
-Vout
RP12-12xxS_DA, RP12-12xxS_DA/SMD
-V6.8μF/50V,
out
1210
L1
RP12-48xxS_DA,
RP12-48xxS_DA/SMD
+Vin
C1
C2
Single
+Vin
-Vin
L1
F1
+Vin
C1
C3
-Vout
+Vout
+Vout
+Vout
-Vin
MLCC
-Vin
1000pF/2kV, 1206 MLCC
4.7μF/50V, 1210 MLCC
C
C33
1000pF/2kV, 1206
MLCC
F1
2.2μF/100V, 1812 MLCC
L1000pF/2kV,
1
1206
MLCC
+Vout
+Vin
+Vin
C1
C2
C4
Dual
C3
-Vout
+Vout
-Vout
-Vin
+Vout
+Vin
C2
-Vin
L1
F1
+Vin
C1
Com
Com
C2/C3
C3
-Vin
-Vout
F1
C1
C3
C3
RP12-24xxS_DA, RP12-24xxS_DA/SMD
F1
-Vout
C1
MODEL
-Vin
-Vout
Com
Com
C2
F1
+Vin
+Vout
+Vout
-Vout
-Vout
+Vout
+Vout
Com
Com
-Vout
C4
-Vout
+Vout
+Vout
C2
Com
Com
-Vin
-Vin
-Vout
-Vout
-Vin
-Vin
C4
-Vout
-Vout
C4
Component List Class B
MODEL
C1
C2
C3/C4
L1
RP12-12xxS_DA
RP12-12xxS_DA/SMD
3.3μF/50V, 1812 MLCC
N/A
1000pF/2kV, 1206 MLCC
CMC :325µH
ref: WE 744290321 or CMC-06
RP12-24xxS_DA
RP12-24xxS_DA/SMD
4.7μF/50V, 1812 MLCC
N/A
1000pF/2kV, 1206 MLCC
CMC: 325µH
ref: WE 744290321 or CMC-06
RP12-48xxS_DA
RP12-48xxS_DA/SMD
2.2μF/100V, 1812 MLCC
2.2µF/100V, 1812 MLCC
1000pF/2kV, 1206 MLCC
CMC: 325µH
ref: WE 744290321 or CMC-06
www.recom-power.com
REV.: 3/2020
PD-5
RP12-A
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
DIMENSIONS and PHYSICAL CHARACTERISTICS
Parameter
Type
Value
Material
case
base
potting
nickel coated copper
non-conductive black plastic
epoxy (UL94-V0)
Dimensions (LxWxH)
DIP24
SMD
31.8 x 20.3 x 10.2mm
32.0 x 20.3 x 11.2mm
Weight
DIP24
SMD
18g
20g
DIP24 Dimension Drawing (mm)
Pin Connections DIP24
20.3
10.2
31.8
Pin #
1
2
3
9
11
14
16
22
23
2.0
Recommended Footprint Details
8 x 2.54= 20.32
2.54
11
Bottom View
23 22
16
23 22
14
2.54
9
2.54
Ø0.8+0.15/-0
5.08
15.24
1 2 3
2.5
Ø0.5±0.1
3.8
10 x 2.54= 25.40
16
14
9
11
Dual
CTRL
-Vin
-Vin
Com
-Vout
+Vout
Com
+Vin
+Vin
NC = No Connection
Pin Pitch Tolerance ±0.25mm
xx.x = ±0.5mm
xx.xx = ±0.25mm
Top View
1 2 3
Single
CTRL
-Vin
-Vin
NC
NC
+Vout
-Vout
+Vin
+Vin
SMD Dimension Drawing (mm)
Pin Connections SMD
20.3
11.2
10.9
32.0
25.4
10.16
2.54
0.50±0.1
9 10 11 12
Bottom View
24 23 22 21 20
16 15 14 13
26.4
1 2 3 4 5
2.54
1.50
24 23 22 21 20
16 15 14 13
Top View
1 2 3 4 5
9 10 11 12
2.00
Recommended Footprint Details
Pin #
1
2
3
9
11
14
16
22
23
Others
Single
CTRL
-Vin
-Vin
NC
NC
+Vout
-Vout
+Vin
+Vin
NC
Dual
CTRL
-Vin
-Vin
Com
-Vout
+Vout
Com
+Vin
+Vin
NC
NC = No Connection
Pin Pitch Tolerance ±0.25mm
xx.x = ±0.5mm
xx.xx = ±0.25mm
11 x 2.54 = 27.94
www.recom-power.com
REV.: 3/2020
PD-6
RP12-A
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
PACKAGING INFORMATION
Parameter
Packaging Dimension (LxWxH)
Packaging Quantity
Type
DIP24
SMD
tube
DIP24, SMD
Storage Temperature Range
Storage Humidity
Value
255.0 x 23.0 x 19.0mm
255.0 x 32.0 x 16.0mm
7pcs
-55°C to +125°C
non-condensing
5% - 95% RH
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 3/2020
PD-7