Features
•
•
•
•
•
•
Regulated
Converter
2:1 input voltage range
1.6kVDC isolation
UL certified
Efficiency up to 89%
Six-sided continuous shield
No minimum load required
Description
The RP15-A series are ultraminiature power DC/DC converters in a case half the size of industry
standard 15W converters. Despite their small size, the RP15-A converters are fully specified devices
with output currents up to 4 Amps, no minimum load, 1600VDC isolation and low ripple/noise figures.
The outputs are also fully protected against short circuits, overcurrent and overvoltage. The RP15-A
series will find many uses in applications where board space and/or board height is at a premium.
DC/DC Converter
RP15-A
15 Watt
1“ x 1“
Single and Dual
Output
Selection Guide
Part Number
Input
Output
Output
Input (1) Efficiency (1) Max. Capacitive
Voltage Range Voltage
Current
Current
typ.
Load (2)
[VDC] [VDC] [mA] [mA] [%]
[µF]
RP15-123.3SA (3,4) 9-18 3.3 4000 1310 84
12000
RP15-1205SA (3,4)
9-18
5
3000
1420
88
6000
RP15-1212SA (3,4) 9-18 12 1300 1512 86
1000
RP15-1215SA (3,4) 9-18 15 1000 1420 88
660
RP15-243.3SA (3,4) 18-36 3.3 4000 640 86
12000
RP15-2405SA (3,4) 18-36 5 3000 710 88
6000
RP15-2412SA (3,4)
18-36
12
1300
747
87
1000
RP15-2415SA (3,4) 18-36 15 1000 710 88
660
RP15-483.3SA (3,4) 36-75 3.3 4000 320 86
12000
RP15-4805SA (3,4) 36-75 5 3000 355 88
6000
RP15-4812SA (3,4) 36-75 12 1300 369 88
1000
RP15-4815SA (3,4) 36-75 15 1000 355 88
660
RP15-1205DA (3,4) 9-18
±5 ±1500 1471 85
±3000
RP15-1212DA (3,4) 9-18 ±12 ±625 1437 87
±520
RP15-1215DA (3,4) 9-18 ±15 ±500 1420 88
±330
RP15-2405DA (3,4) 18-36 ±5 ±1500 735 85
±3000
RP15-2412DA (3,4) 18-36 ±12 ±625 710 88
±520
RP15-2415DA (3,4) 18-36 ±15 ±500 710 88
±330
RP15-4805DA (3,4)
36-75
±5
±1500
368
85
±3000
RP15-4812DA (3,4) 36-75 ±12 ±625 351 89
±520
RP15-4815DA (3,4) 36-75 ±15 ±500 355 88
±330
E196683
UL60950-1 certified
Notes:
Note1: Maximum values at nominal input voltage and full load
Note2: Max. Cap load is tested at minimum Input and constant resistive load
Model Numbering
RP15-__ __ _A/_-_
nom. Input Voltage
Output Voltage
“Package (4)”
“CTRL Logic (3)”
Single or Dual
Notes:
Note3:
Note4:
no suffix for standard part without Trim or CTRL pin
add suffix ”P” for CTRL function with positive logic (1=ON, 0=OFF) and Trim pin
add suffix “N” for CTRL function with negative logic (0=ON, 1=OFF) and Trim pin
add suffix “-HC” for premounted Heat-sink with clamps
Ordering Examples
RP15-2405SA/P = 24V input, 5V output, single, positive Logic CTRL pin
RP15-4805DA-HC = 48V input, ±5V output, dual, without CTRL pin, Heat-sink premounted
www.recom-power.com
REV.: 5/2019
PD-1
RP15-A
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
nom. Vin = 12VDC
nom. Vin = 24VDC
nom. Vin = 48VDC
9VDC
18VDC
36VDC
12VDC
24VDC
48VDC
Max.
Input Filter
Input Voltage Range
nom. Vin = 12VDC
nom. Vin = 24VDC
nom. Vin = 48VDC
DC-DC ON
DC-DC OFF
8VDC
nom. Vin = 24VDC
DC-DC ON
DC-DC OFF
14.5VDC
nom. Vin = 48VDC
DC-DC ON
DC-DC OFF
30.5VDC
Input Surge Voltage
100s max.
nom. Vin = 12VDC
Under Voltage Lockout (UVLO)
Pi-Type
18VDC
36VDC
75VDC
36VDC
50VDC
100VDC
9VDC
18VDC
36VDC
Input Reflected Ripple Current (5)
30mAp-p
refer to “OUTPUT VOLTAGE TRIMMING”
Output Voltage Trimming
-10%
Minimum Load
+10%
0%
Power up
ON/OFF CTRL
Start-up Time
30ms
30ms
Positive Logic
DC-DC ON
DC-DC OFF
Open or 3.0VDC < VCTRL< 15VDC
Short or 0VDC < VCTRL< 1.2VDC
Negative Logic
DC-DC ON
DC-DC OFF
Short or 0VDC < VCTRL< 1.2VDC
Open or 3.0VDC < VCTRL< 15VDC
-0.5mA
+1.0mA
ON/OFF CTRL (6)
Input Current of CTRL pin
DC-DC ON
Standby Current
DC-DC OFF
2.5mA
Internal Operating Frequency
360kHz
measured at 20MHz BW,
with a 1µF M/C X7R and 10µF T/C
Ripple and Noise
400kHz
3.3Vout, 5Vout
12Vout, 15Vout
75mVp-p
100mVp-p
±5Vout, ±12Vout, ±15Vout
100mVp-p
440kHz
Notes:
Note5: Simulated source impedance of 12μH. 12μH inductor in series with +Vin
Note6: If no suffix is specified, the control pin will be omitted. If fitted, the ON/OFF control function can be
positive or negative logic. The pin voltage is referenced to -Vin pin
RP15-1205SA
Efficiency vs. Input Voltage full load
Efficiency vs. Output Current
95
90
90
85
80
Efficiency [%]
Efficiency [%]
85
75
70
65
60
55
9Vin
12Vin
18Vin
50
45
40
10
20
30
40
50
60
70
80
90
80
75
70
65
60
100
9
10
11
12
13
14
15
16
17
18
Input Voltage [VDC]
Output Current [%]
continued on next page
www.recom-power.com
REV.: 5/2019
PD-2
RP15-A
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
RP15-2405SA
Efficiency vs. Output Current
Efficiency vs. Input Voltage
95
95
90
90
80
Efficiency [%]
Efficiency [%]
85
75
70
65
60
55
18Vin
24Vin
36Vin
50
45
40
20
10
30
40
50
60
70
80
90
85
80
75
70
65
60
100
20
18
22
Output Current [%]
RP15-4805SA
24
26
28
30
32
34
36
66
72
75
Input Voltage [VDC]
Efficiency vs. Output Current
Efficiency vs. Input Voltage
95
95
90
90
80
Efficiency [%]
Efficiency [%]
85
75
70
65
60
55
36Vin
48Vin
75Vin
50
45
40
10
20
30
40
50
60
70
80
90
85
80
75
70
65
100
36
40
Output Current [%]
44
48
52
56
60
Input Voltage [VDC]
OUTPUT VOLTAGE TRIMMING
Output Voltage Trimming
Single output Powerline converters offer the feature of trimming the output voltage over a certain range around the nominal value by using external
trim resistors. No general equation can be given for calculating the trim resistors, but the following trimtables give typical values for choosing these
trimming resistors. If voltages between the given trim points are required, extrapolate between the two nearest given values to work out the resistor
required or use a variable resistor to set the output voltage. Output can be externally trimmed by using the method shown below.
-Vout
Trim up
Trim
Trim down
RD
RU
+Vout
Trim
RP15-xx3.3A
Trim up
1
2
3
4
5
6
7
8
9
10
[%]
Vout =
3.333
3.366
3.399
3.432
3.465
3.498
3.531
3.564
3.597
3.63
[VDC]
385.071
191.511
126.990
94.730
75.374
62.470
53.253
46.340
40.963
36.662
[kW]
1
2
3
4
5
6
7
8
9
10
[%]
3.267
3.234
3.201
3.168
3.135
3.102
3.069
3.036
3.003
2.97
[VDC]
116.719
54.779
34.133
23.810
17.616
13.486
10.537
8.325
6.604
5.228
[kW]
RU =
Trim down
Vout =
RD =
continued on next page
www.recom-power.com
REV.: 5/2019
PD-3
RP15-A
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
RP15-xx05A
Trim up
1
2
3
4
5
6
7
8
9
10
[%]
Vout =
5.05
5.10
5.15
5.20
5.25
5.30
5.35
5.4
5.45
5.50
[VDC]
253.450
125.700
83.117
61.825
49.050
40.533
34.450
29.888
26.339
23.500
[kW]
RU =
1
2
3
4
5
6
7
8
9
10
[%]
4.95
4.90
4.85
4.80
4.75
4.70
4.65
4.60
4.55
4.50
[VDC]
248.340
120.590
78.007
56.715
43.940
35.423
29.340
24.778
21.229
18.390
[kW]
Trim down
Vout =
RD =
RP15-xx12A
Trim up
1
2
3
4
5
6
7
8
9
10
[%]
Vout =
12.12
12.24
12.36
12.48
12.60
12.72
12.84
12.96
13.08
13.20
[VDC]
203.223
99.057
64.334
46.973
36.557
29.612
24.652
20.932
18.038
15.723
[kW]
1
2
3
4
5
6
7
8
9
10
[%]
11.88
11.76
11.64
11.52
11.40
11.28
11.16
11.04
10.92
10.8
[VDC]
776.557
380.723
248.779
182.807
143.223
116.834
97.985
83.848
72.853
64.057
[kW]
RU =
Trim down
Vout =
RD =
RP15-xx15A
Trim up
1
2
3
4
5
6
7
8
9
10
[%]
Vout =
15.15
15.3
15.45
15.60
15.75
15.90
16.05
16.20
16.35
16.50
[VDC]
161.557
78.223
50.446
36.557
28.223
22.668
18.700
15.723
13.409
11.557
[kW]
1
2
3
4
5
6
7
8
9
10
[%]
14.85
14.70
14.55
14.40
14.25
14.10
13.95
13.80
13.65
13.50
[VDC]
818.223
401.557
262.668
193.223
151.557
123.779
103.938
89.057
77.483
68.223
[kW]
RU =
Trim down
Vout =
RD =
REGULATIONS
Parameter
Condition
Value
Output Accuracy
±1.0%
Line Regulation
low line to high line,
full load
Single
Dual
±0.2%
±0.5%
Load Regulation
0% to 100% load
Single
Dual
±0.2%
±1.0%
asymmetrical 25%100% load
±5.0%
Cross Regulation
Transient Response Recovery Time
www.recom-power.com
25% load step change
REV.: 5/2019
250μs typ.
PD-4
RP15-A
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
PROTECTIONS
Parameter
Condition
Value
Short Circuit Protection (SCP)
continuous, automatic recovery
Over Voltage Protection (OVP)
zener diode clamp
Over Load Protection (OLP)
3.7 - 5.4VDC
5.6 - 7.0VDC
13.5 - 19.6VDC
16.8 - 20.5VDC
3.3Vout
5Vout
12Vout
15Vout
% of Iout rated
150% typ., Hiccup mode
Isolation Voltage (7)
I/P to O/P
I/P to O/P to case
Isolation Resistance
Viso= 500VDC
1.6kVDC/ 1 minute
1.0kVDC/ 1 minute
1GΩ min.
1000pF max.
Isolation Capacitance
Notes:
Note7: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note8: This power module is not internally fused. An input line fuse must always be used
Recom suggests: 12Vin= T3.15A; 24Vin= T1.6A; 48Vin= T1.25A slow blow types
ENVIRONMENTAL
Parameter
Condition
Value
-40°C to +68°C
-40°C to +105°C
without derating
with derating
Operating Temperature Range
Maximum Case Temperature
+105°C
Temperature Coefficient
±0.02%/K max.
@ natural convection
0.1m/s
Thermal Impedance
Operating Humidity
without heat-sink
with heat-sink
18.2K/W
15.8K/W
non-condensing
5% - 95% RH
Thermal Shock
according to MIL-STD-810F
Vibration
according to MIL-STD-810F
according to MIL-HDBK-217F, G.B.
Bellcore TR-NWT-000332 (9)
MTBF
Derating Graph (10)
1600 x 103 hours
1330 x 103 hours
+25°C
RP15-1215SA-HC
100
100
80
80
Output Power [%]
Output Power [%]
RP15-1215SA
60
40
20
0
-40
-20
0
20
40
60
68
80
Ambient Temperature [°C]
60
40
20
0
-40
100
105
-20
0
20
40
60
80
73
Ambient Temperature [°C]
100
105
Notes:
Note9: BELLCORE TR-NWT-000332. Case l: 50% Stress, Ta= 40°C. MIL-HDBK 217F Notice 2. Ta = 25°C, full load, (controlled environment)
Note10: Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-number
not shown here please contact RECOM Techsupport for detailed information
www.recom-power.com
REV.: 5/2019
PD-5
RP15-A
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Condition
Information Technology Equipment, General Requirements for Safety
Standard
UL60950-1, 1st Edition
CAN/CSA-C22.2 No. 60950-1-07, 1st Edition
E196683
RoHS 2
RoHS-2011/65/EU + AM-2015/863
EMC Compliance
Condition
Standard / Criterion
Electromagnetic compatibility of multimedia equipment - Emission
requirements
with external filter
(see filter suggestion below)
EN55032, Class A and B
ESD Electrostatic discharge immunity test
Air ±8kV and Contact ±6kV
EN61000-4-2, Criteria A
Radiated, radio-frequency, electromagnetic field immunity test
10V/m
EN61000-4-3, Criteria A
Fast Transient and Burst Immunity
(11)
±2kV
EN61000-4-4, Criteria A
±1kV
EN61000-4-5, Criteria A
Immunity to conducted disturbances, induced by radio-frequency fields
3Vr.m.s
EN61000-4-6, Criteria A
Surge Immunity
(11)
Power Magnetic Field Immunity
100A/m continuous; 1000A/m 1s
Notes:
Note11: An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5
Recom suggests Nippon chemi-con KY series 220μF/100V
EMC Filtering Suggestions according to EN55032
Single
Dual
C3
F1
+Vin
+Vin
C1
-Vin
C2
F1
+Vin
+Vin
C1
C3
-Vin
F1
+Vin
C3
+Vout
+Vout
-Vout
+Vin
C1
C2
-Vout
+Vout
C4
EN61000-4-8, Criteria A
-Vin
+Vout
C2
C3
-Vin
F1
+Vin
C2
-Vout
C4
-Vout
-Vin
C3/C4
-Vout
470pF/2kV,
1808 MLCC
C
C
RP15-24xxSA, RP15-24xxDA
6.8μF/50V, 1812 MLCC
6.8μF/50V, 1812 MLCC
470pF/2kV, 1808 MLCC
C2
4
L1
F1
in
F1
1
2.2μF/100V,
1812
MLCC
C1
C4
-Vin
-Vout
C3
-Vout
+Vout
C5
+Vout
-Vin
C2
+Vin
Dual
C3
L1
F1
C4
-Vin
+Vout
C2
C3
-Vout
-Vout
+Vout
C5
Com
-Vin
-Vin
-Vout
-Vout
-Vin
-Vin
C5
Component List Class B
MODEL
RP15-12xxSA,
RP15-12xxDA
RP15-24xxSA,
RP15-24xxDA
RP15-48xxSA,
RP15-48xxDA
www.recom-power.com
C1
10μF/25V
1812 MLCC
6.8μF/50V
1812 MLCC
2.2μF/100V
1812 MLCC
+Vout
Com
Com
+Vin
C1
-Vout
4
470pF/2kV, 1808 MLCC
+Vin
Single
+Vin
C2
out
4
L
2.2μF/100V,+V
1812 MLCC+V
+Vout
C3
C1
-Vin
N/A
+Vin
+Vin
C2
-Vin
10μF/25V, 1812 MLCC
1
RP15-48xxSA,
RP15-48xxDA
C1
-Vout
RP15-12xxSA, RP15-12xxDA
C
C
L
F1
C1
+Vout
Com
Com
-Vin
4
+Vin
-Vout
+Vout
Component List Class A
-VMODEL
in
Com
Com
+Vin
C1
+Vout
+Vout
-Vout
+Vout
Com
-Vout
C5
C2
N/A
N/A
2.2μF/100V
1812 MLCC
C3
C4/C5
L1
10μF/25V
1812 MLCC
6.8μF/50V
1812 MLCC
470pF/2kV
1808 MLCC
470pF/2kV
1808 MLCC
CMC: 145μH
ref: WE 482210002 ref: CMC-07
CMC: 325μH
ref: WE 744290321 ref: CMC-06
2.2μF/100V
1812 MLCC
470pF/2kV
1808 MLCC
CMC: 325μH
ref: WE 744290321 ref: CMC-06
REV.: 5/2019
PD-6
RP15-A
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
DIMENSIONS and PHYSICAL CHARACTERISTICS
Parameter
Type
Material
Dimensions (LxWxH)
Weight
Value
case
base
potting
without Heat-sink
with Heat-sink
nickel coated copper
FR4 PCB
epoxy (UL94V-0)
25.4 x 25.4 x 9.9mm
31.4 x 25.4 x 16.5mm
without Heat-sink
with Heat-sink
15g
21.5g
Dimension Drawing (mm)
Pinning Information
25.4
5.6
9.9
25.4
2.54
8 x 2.54= 20.32
Ø 1.0±0.1
Recommended Footprint Details
3
2
Bottom View
3
2
5
1
6
Single
+Vin
-Vin
CTRL(3)
+Vout
Trim
-Vout
Dual
+Vin
-Vin
CTRL(3)
+Vout
Com
-Vout
Pin Pitch Tolerance ±0.25mm
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.25mm
2.54
2.54
1
12.70
7.62
4
10.2
5.08
2.54
Pin #
1
2
3
4
5
6
Top View
5
4
6
Dimension Drawing with Heat-sink (mm)
25.4
25.4
Top View
Heat-sink
24.2
5.6
16.5
9.9
5.85
31.4
2.54
Ø 1.0±0.1
8 x 2.54= 20.32
2.54
1
3
REV.: 5/2019 6
PD-7
2.54
4
10.2
5.08
www.recom-power.com
7.62
2.54
2
5
RP15-A
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
PACKAGING INFORMATION
Parameter
Type
Value
Packaging Dimension (LxWxH)
tube
tray
without heat-sink
with heat-sink
257.0 x 28.5 x 21.0mm
230.0 x 180.0 x 28.0mm
Packaging Quantity
tube
tray
without heat-sink
with heat-sink
8pcs
20pcs
Storage Temperature Range
Storage Humidity
-55°C to +125°C
non-condensing
5% - 95% RH
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 5/2019
PD-8