Features
Regulated
Converter
•
•
•
•
•
•
2:1 input voltage range
1.6kVDC isolation
UL certified
Efficiency up to 88%
Six-sided continuous shield
Fixed operating frequency
Description
The RP15-F series DC/DC converters are certified to UL 60950-1 and to cUL 60950-1. This makes
them ideal for all telecom and industrial applications where approved safety standards are required. The
industry standard 2” x 1” package meets military standards for thermal shock and vibration tolerance.
Selection Guide
Part Number
Input
Output
Output
Input (1) Efficiency (1) Max. Capacitive
Voltage Range Voltage
Current
Current
typ.
Load (2)
[VDC] [VDC] [mA] [mA] [%]
[µF]
RP15-123.3SF (3,4) 9-18 3.3 4000 1392 79
10200
RP15-1205SF (3,4)
9-18
5
3000
1524
82
7050
RP15-1212SF (3,4) 9-18 12 1250 1453 86
1035
RP15-1215SF (3,4) 9-18 15 1000 1453 86
705
RP15-243.3SF (3,4) 18-36 3.3 4000 688 80
10200
RP15-2405SF (3,4) 18-36 5 3000 744 84
7050
RP15-2412SF (3,4)
18-36
12
1250
735
85
1035
RP15-2415SF (3,4) 18-36 15 1000 735 85
705
RP15-483.3SF (3,4) 36-75 3.3 4000 340 81
10200
RP15-4805SF (3,4) 36-75 5 3000 377 83
7050
RP15-4812SF (3,4) 36-75 12 1250 359 87
1035
RP15-4815SF (3,4) 36-75 15 1000 363 86
705
RP15-1205DF (3,4) 9-18
±5 ±1500 1506 83
±1020
RP15-1212DF (3,4) 9-18 ±12 ±625 1453 86
±495
RP15-1215DF (3,4) 9-18 ±15 ±500 1488 84
±165
RP15-2405DF (3,4) 18-36 ±5 ±1500 744 84
±1020
RP15-2412DF (3,4)
18-36
±12
±625
727
86
±495
RP15-2415DF (3,4) 18-36 ±15 ±500 727 86
±165
RP15-4805DF (3,4) 36-75 ±5 ±1500 368 85
±1020
RP15-4812DF (3,4) 36-75 ±12 ±625 355 88
±495
RP15-4815DF (3,4) 36-75 ±15 ±500 359 87
±165
DC/DC Converter
RP15-F
15 Watt
2“ x 1“
Single and Dual
Output
E196683
UL60950-1 certified
Notes:
Note1: Maximum values at nominal input voltage and full load
Note2: Max. Cap load is tested at minimum input and constant resistive load
Model Numbering
RP15-__ __ _F/_- _
nom. Input Voltage
Output Voltage
“Package (4)”
“CTRL Logic (3)”
Single or Dual
Notes:
Note3:
Note4:
no suffix for standard part without CTRL pin
add suffix “P” for CTRL function with positive logic (1=ON, 0=OFF)
add suffix “N” for CTRL function with negative logic (0=ON, 1=OFF)
add suffix “-HC” for premounted Heat-sink with clips
Ordering Examples
RP15-2405SF/P = 24V input, 5V output, single, positive logic CTRL pin
RP15-4812DF/N-HC = 48V input, ±12V output, dual, negative logic CTRL pin, Heat-sink premounted
www.recom-power.com
REV.: 3/2019
PD-1
RP15-F
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
nom. Vin = 12VDC
nom. Vin = 24VDC
nom. Vin = 48VDC
9VDC
18VDC
36VDC
12VDC
24VDC
48VDC
Max.
Input Filter
Input Voltage Range
Input Surge Voltage
Pi-Type
18VDC
36VDC
75VDC
36VDC
50VDC
100VDC
nom. Vin = 12VDC
nom. Vin = 24VDC
nom. Vin = 48VDC
100ms max.
Input Reflected Ripple Current (5)
20mAp-p
10%
Minimum Load (6)
Start-up Time
Power up
20ms
Positive Logic
DC-DC ON
DC-DC OFF
Negative Logic
DC-DC ON
DC-DC OFF
ON/OFF CTRL (7)
Input Current of CTRL pin
DC-DC ON
Standby Current
DC-DC OFF
Open or 3.5VDC < VCTRL< 12VDC
Short or 0VDC < VCTRL< 1.2VDC
Short or 0VDC < VCTRL< 1.2VDC
Open or 3.5VDC < VCTRL< 12VDC
-0.5mA
20mA
Single
Dual
Internal Operating Frequency
Ripple and Noise
+1.0mA
450kHz
270kHz
Single
Dual
20MHz BW
500kHz
300kHz
550kHz
330kHz
50mVp-p
75mVp-p
Notes:
Note5: Simulated source impedance of 12μH. 12μH inductor in series with +Vin
Note6: The RP15-F series requires a minimum of 10% loading on the output to maintain specified regulation. Operation
under no-load condition will not damage these devices, however they may not meet all listed specification
Note7: If no suffix is specified, the control pin will be omitted. If fitted, the ON/OFF control function can be
positive or negative logic. The pin voltage is referenced to -Vin pin
RP15-1205SF
Efficiency vs. Input Voltage full load
Efficiency vs. Output Current
95
86
90
84
80
Efficiency [%]
Efficiency [%]
85
75
70
65
60
55
9Vin
12Vin
18Vin
50
45
20
30
40
50
60
70
80
90
80
78
76
40
10
82
74
100
9
10
11
12
13
14
15
16
17
18
Input Voltage [VDC]
Output Current [%]
continued on next page
www.recom-power.com
REV.: 3/2019
PD-2
RP15-F
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
RP15-2405SF
Efficiency vs. Output Current
Efficiency vs. Input Voltage full load
86
95
90
84
80
75
70
65
60
55
80
78
18Vin
24Vin
36Vin
50
45
40
82
Efficiency [%]
Efficiency [%]
85
76
74
10
20
30
40
50
60
70
80
90
100
18
20
22
24
26
28
30
32
34
36
Input Voltage [VDC]
Output Current [%]
RP15-4805SF
Efficiency vs. Output Current
Efficiency vs. Input Voltage full load
95
88
90
86
80
84
Efficiency [%]
Efficiency [%]
85
75
70
65
60
82
80
55
36Vin
48Vin
75Vin
50
45
78
76
40
10
20
30
40
50
60
70
80
90
100
36
40
44
48
52
56
60
66
72
75
Input Voltage [VDC]
Output Current [%]
REGULATIONS
Parameter
Condition
Value
Output Accuracy
Line Regulation
Load Regulation
Cross Regulation
Transient Response Recovery Time
www.recom-power.com
±1.0%
low line to high line, full load
±0.5%
Single
Dual
±0.5%
±0.1%
asymmetrical 25%100% load
±5.0%
10% to 100% load
25% load step change
REV.: 3/2019
250μs typ.
PD-3
RP15-F
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
PROTECTIONS
Parameter
Condition
Value
Short Circuit Protection (SCP)
continuous, automatic recovery
Over Voltage Protection (OVP)
zener diode clamp
Over Load Protection (OLP)
3.9VDC
6.2VDC
15VDC
18VDC
3.3Vout
5Vout
12Vout
15Vout
% of Iout rated
Isolation Voltage (8)
I/P to O/P
I/P to O/P to case
Isolation Resistance
Viso= 500VDC
150% typ.
1.6kVDC/ 1 minute
1.6kVDC/ 1 minute
1GΩ min.
Isolation Capacitance
300pF typ.
Notes:
Note8: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note9: This power module is not internally fused. An input line fuse must always be used
ENVIRONMENTAL
Parameter
Condition
Value
without derating
with derating
Operating Temperature Range
-40°C to +75°C
-40°C to +100°C
Maximum Case Temperature
+100°C
Temperature Coefficient
±0.02%/K max.
@ natural convection
0.1m/s
Thermal Impedance
Operating Humidity
without heat-sink
with heat-sink
12K/W
10K/W
non-condensing
5% - 95% RH
Operating Altitude
2000m
Thermal Shock
according to MIL-STD-810F
Vibration
according to MIL-STD-810F
MIL-HDBK-217F, G.B.
Bellcore TR-NWT-000332 (10)
MTBF
2318 x 103 hours
2041 x 10³ hours
Derating Graph (11)
RP15-4812SF-HC
100
100
80
80
Output Power [%]
Output Power [%]
RP15-4812SF
60
40
20
0
-40
-20
0
20
40
60
80
75
100
60
40
20
0
-40
120
-20
0
20
40
60
80
78
100 120
Ambient Temperature [°C]
Ambient Temperature [°C]
Notes:
Note10: BELLCORE TR-NWT-000332. Case l: 50% Stress, Temperature at 40°C (Ground fixed and controlled environment)
Note11: Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-number
not shown here please contact RECOM Techsupport for detailed information
www.recom-power.com
REV.: 3/2019
PD-4
RP15-F
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Condition
Information Technology Equipment, General Requirements for Safety
Standard
UL60950-1, 2nd Edition, 2011
CAN/CSA-C22.2 No. 60950-1-07, 2nd Edition, 2011
E196683
EAC
RU-AT.49.09571
TP TC 004/2011
RoHS2
RoHS-2011/65/EU + AM-2015/863
EMC Compliance
Condition
Standard / Criterion
Electromagnetic compatibility of multimedia equipment - Emission
requirements
with external filter
(see filter suggestion below)
EN55032, Class A and B
ESD Electrostatic discharge immunity test
Air ±8kV and Contact ±6kV
EN61000-4-2, Criteria B
10 V/m
EN61000-4-3, Criteria A
±2kV
EN61000-4-4, Criteria B
±1kV
EN61000-4-5, Criteria B
10 Vr.m.s
EN61000-4-6, Criteria A
100A/m continuous; 1000A/m 1s
EN61000-4-8, Criteria A
Radiated, radio-frequency, electromagnetic field immunity test
Fast Transient and Burst Immunity
(12)
Surge Immunity (12)
Immunity to conducted disturbances, induced by radio-frequency fields
Power Magnetic Field Immunity
Notes:
Note12: An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5
Recom suggests Nippon chemi-con KY series 220μF/100V
EMC Filtering Suggestions according to EN55032
Single
Dual
C2
C2
F1
+Vin
+Vin
C1
-Vin
F1
+Vin
+Vin
-Vin
-Vout
-Vout
+Vin
C1
+Vout
C3
-Vin
+Vout
C2
F1
+Vin
-Vout
RP15-24xxSF, RP15-24xxDF
2.2μF/50V, 1812 MLCC
1000pF/2kV, 1808 MLCC
1000pF/2kV, 1808 MLCC
1.5μF/100V,+V1812
MLCC
+Vin
out
F1
1
1000pF/2kV,
1808
MLCC
1000pF/2kV, 1808 MLCC
3
1
RP15-48xxSF,
RP15-48xxDF
Single
C1
-Vin
-Vout
+Vin
C1
C2
-Vout
+Vout
C4
+Vout
-Vin
+Vin
+Vout
Dual
C2
C3
L1
F1
-Vin
C2
-Vout
+Vout
C4
Com
-Vin
-Vin
-Vout
-Vout
-Vin
-Vin
C4
Component List Class B
MODEL
+Vout
Com
Com
-Vout
+Vin
C1
-Vout
3
+Vin
C3
L1
F1
L
+Vout
C2
C3
+Vout
Com
-Vout
C3
1000pF/2kV,
C 1808 MLCC
+Vin
+Vin
-Vin
C2
-Vin
-Vout
1000pF/2kV, 1808 MLCC
C1
-Vin
C1
6.8μF/50V, 1812 MLCC
L
F1
C3
RP15-12xxSF, RP15-12xxDF
C
C3
+Vin
-Vout
+Vout
Com
-Vin
-VMODEL
in
-Vout
+Vin
C1
Com
Com
-Vin
Component List Class A
+Vout
+Vout
C1
C2
F1
+Vin
+Vout
+Vout
-Vout
+Vout
Com
-Vout
C4
C1
C2
C3/C4
L1
RP15-12xxSF
RP15-12xxDF
4.7μF/50V
1812 MLCC
N/A
1000pF/2kV
1808 MLCC
CMC: 325μH
ref.: WE 744290321 ref.: CMC-06
RP15-24xxSF
RP15-24xxDF
3.3μF/50V
1812 MLCC
N/A
1000pF/2kV
1808 MLCC
CMC: 325μH
ref.: WE 744290321 ref.: CMC-06
RP15-48xxSF
RP15-48xxDF
2.2μF/100V
1812 MLCC
2.2μF/100V
1812 MLCC
1000pF/2kV
1808 MLCC
CMC: 325μH
ref.: WE 744290321 ref.: CMC-06
www.recom-power.com
REV.: 3/2019
PD-5
RP15-F
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
DIMENSIONS and PHYSICAL CHARACTERISTICS
Parameter
Type
Material
Dimensions (LxWxH)
Weight
Value
case
base
potting
without Heat-sink
with Heat-sink
nickel coated copper
non-conductive black plastic
epoxy (UL94V-0)
50.8 x 25.4 x 10.2mm
56.8 x 25.4 x 16.8mm
without Heat-sink
with Heat-sink
27g
37.89g
Dimension Drawing (mm)
Pinning Information
5.6
25.4
10.2
50.8
Pin #
1
2
3
4
5
6
15.20
8 x 2.54= 20.32
Single
+Vin
-Vin
+Vout
no Pin
-Vout
CTRL (3)
Dual
+Vin
-Vin
+Vout
Com
-Vout
CTRL (3)
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.25mm
Ø 1.0±0.1
Recommended Footprint Details
2
Bottom View
6
5
2
4
1
2.54
6
2.54
1
12.70
7.62
3
10.2
5.08
2.54
Top View
4
3
5
Dimension Drawing with Heat-sink (mm)
50.8
10.2
16.8
5.85
56.8
15.20
8 x 2.54= 20.32
24.2
5.6
25.4
Top View
Heat-sink
Ø 1.0±0.1
2.54
2.54
1
REV.: 3/2019
6
2
PD-6
5
2.54
7.62
3
10.2
5.08
www.recom-power.com
RP15-F
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
PACKAGING INFORMATION
Parameter
Type
Value
Packaging Dimension (LxWxH)
tube
tray
without heat-sink
with heat-sink
255.0 x 54.0 x 22.0mm
302.5 x 222.0 x 20.0mm
Packaging Quantity
tube
tray
without heat-sink
with heat-sink
9pcs
20pcs
Storage Temperature Range
Storage Humidity
-55°C to +125°C
non-condensing
5% - 95% RH
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 3/2019
PD-7