RP20-4815DFR/XC-HC

RP20-4815DFR/XC-HC

  • 厂商:

    RECOM

  • 封装:

    插件,50.8x25.4mm

  • 描述:

    RP20-4815DFR/XC-HC

  • 详情介绍
  • 数据手册
  • 价格&库存
RP20-4815DFR/XC-HC 数据手册
Features • Wide 4:1 input voltage range • 2.25kVDC isolation DC/DC Converter • Efficiency up to 89% Regulated Converter • Six-sided continuous shield RP20-FR • EN50155, UL/IEC/EN60950-1 certified Description 20 Watt 3 2“ x 1“ Single and Dual Output YEA R T y T compliant M TS TS CONVER REACH CO C M S S 10 from 10 PL U D IA N T PRO O R R M C C CONVER RE M E O E C RoHS 2 + compliant CO Part Number Input Output Output Input (1) Efficiency (1) Max. Capacitive Voltage Range Voltage Current Current typ. Load [VDC] [VDC] [mA] [mA] [%] [µF] RP20-243.3SFR (2,3) 9-36 3.3 4500 728 85 7000 RP20-2405SFR (2,3) 9-36 5 4000 947 88 5000 RP20-2412SFR (2,3) 9-36 12 1670 938 89 850 RP20-2415SFR (2,3) 9-36 15 1330 945 88 700 RP20-483.3SFR (2,3) 18-75 3.3 4500 364 85 7000 RP20-4805SFR (2,3) 18-75 5 4000 473 88 5000 RP20-4812SFR (2,3) 18-75 12 1670 469 89 850 RP20-4815SFR (2,3) 18-75 15 1330 467 89 700 RP20-1103.3SFR (2,3) 43-160 3.3 4500 159 85 7000 RP20-11005SFR (2,3) 43-160 5 4000 209 87 5000 RP20-11012SFR (2,3) 43-160 12 1670 207 88 850 RP20-11015SFR (2,3) 43-160 15 1330 206 88 700 RP20-2412DFR (2,3) 9-36 ±12 ±833 947 88 ±500 RP20-2415DFR (2,3) 9-36 ±15 ±667 937 89 ±350 RP20-4812DFR (2,3) 18-75 ±12 ±833 473 88 ±500 RP20-4815FDFR (2,3) 18-75 ±15 ±667 468 89 ±350 RP20-11012DFR (2,3) 43-160 ±12 ±833 207 88 ±500 RP20-11015DFR (2,3) 43-160 ±15 ±667 204 89 ±350 RE Selection Guide arrant w The RP20-FR series wide range input DC/DC converters are certified to UL60950-1 and cUL 60950-1. This makes them ideal for all telecom and industrial applications where approved safety standards are required. The 110VDC input versions have been especially designed for railway applications. PL U D IA N T PRO E196683 EN50155 certified UL60950-1 certified IEC/EN60950-1 certified EN55032 compliant EN55024 compliant EN50121-3-2 compliant Notes: Note1: Maximum values at nominal input voltage and full load Model Numbering RP20-__ __ _FR/_- _ nom. Input Voltage nom. Output Voltage “Package (3)” “CTRL Logic (2)” Single or Dual Notes: Note2: Note3: no suffix for CTRL function with positive logic (1=ON, 0=OFF) add suffix “N” for CTRL function with negative logic (0=ON, 1=OFF) or add suffix “XC” for omitted CTRL pin (refer to “Dimension Drawing (mm)”) add suffix “-HC” for premounted Heat-sink with clamps Ordering Examples RP20-2405SFR = 24V input, 5V output, single, positive Logic CTRL pin RP20-4812DFR/N-HC = 48V input, ±12V output, dual, negative Logic CTRL pin, Heat-sink premounted RP20-11005SFR/XC = 110V input, 5V output, single, no CTRL pin www.recom-power.com REV.: 6/2020 PD-1 RP20-FR DC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated) BASIC CHARACTERISTICS Parameter Condition Min. nom. Vin = 24VDC, nom. Vin = 48VDC nom. Vin = 110VDC nom. Vin = 24VDC nom. Vin = 48VDC nom. Vin = 110VDC nom. Vin = 24VDC 100s max. nom. Vin = 48VDC nom. Vin = 110VDC DC-DC ON nom. Vin = 24VDC DC-DC OFF Input Filter Input Voltage Range Input Surge Voltage Under Voltage Lockout (UVLO) Typ. Common Mode Choke Pi-Type 36VDC 24VDC 75VDC 48VDC 160VDC 110VDC 50VDC 100VDC 170VDC 9VDC 8VDC 9VDC 18VDC 43VDC nom. Vin = 48VDC DC-DC ON DC-DC OFF 16VDC nom. Vin = 110VDC DC-DC ON DC-DC OFF 40VDC 18VDC 43VDC refer to “OUTPUT VOLTAGE TRIMMING” Output Voltage Trimming Max. -10% +10% Input Reflected Ripple Current 30mAp-p Power up ON/OFF CTRL Start-up Time 30ms 30ms Positive Logic DC-DC ON DC-DC OFF Negative Logic DC-DC ON DC-DC OFF ON/OFF CTRL (4) Input Current of CTRL pin DC-DC ON Standby Current DC-DC OFF Open or 3.0VDC < VCTRL< 15VDC Short or 0VDC < VCTRL< 1.2VDC Short or 0VDC < VCTRL< 1.2VDC Open or 3.0VDC < VCTRL< 15VDC -0.5mA +1.0mA 2.5mA Internal Operating Frequency 297kHz measured at 20MHz BW with a 1µF/50V X7R MLCC Ripple and Noise 330kHz 3.3Vout, 5Vout 12Vout, 15Vout 363kHz 75mVp-p 100mVp-p Notes: Note4: If suffix “XC” is specified, pin6 will be absent. If fitted, the ON/OFF control function can be positive or negative logic. The pin voltage is referenced to -Vin pin RP20-2405SFR Efficiency vs. Output Current 95 Efficiency vs. Input Voltage full load 95 90 90 80 Efficiency [%] Efficiency [%] 85 75 70 65 80 75 70 60 9Vin 24Vin 36Vin 55 50 85 10 20 30 40 50 60 70 80 90 65 60 100 9 12 15 18 21 24 27 30 33 36 Input Voltage [VDC] Output Current [%] continued on next page www.recom-power.com REV.: 6/2020 PD-2 RP20-FR DC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated) RP20-4805SFR Efficiency vs. Output Current 95 90 90 85 80 Efficiency [%] Efficiency [%] 85 75 70 65 60 18Vin 48Vin 75Vin 55 50 Efficiency vs. Input Voltage full load 95 10 20 30 40 50 60 70 80 90 80 75 70 65 60 100 18 24 30 Output Current [%] 36 42 48 54 60 66 72 75 Input Voltage [VDC] RP20-11005SFR Efficiency vs. Output Current 95 90 90 85 Efficiency [%] Efficiency [%] 85 80 75 70 65 60 43Vin 110Vin 160Vin 55 50 10 Efficiency vs. Input Voltage full load 95 80 75 70 65 60 20 30 40 50 60 70 80 90 100 43 52 62 72 84 96 110 125 136 143 160 Input Voltage [VDC] Output Current [%] OUTPUT VOLTAGE TRIMMING Output Voltage Trimming Single output Powerline converters offer the feature of trimming the output voltage over a certain range around the nominal value by using external trim resistors. No general equation can be given for calculating the trim resistors, but the following trimtables give typical values for choosing these trimming resistors. If voltages between the given trim points are required, extrapolate between the two nearest given values to work out the resistor required or use a variable resistor to set the output voltage. Output can be externally trimmed by using the method shown below. -Vout Trim up Trim Trim down RD RU Trim +Vout continued on next page www.recom-power.com REV.: 6/2020 PD-3 RP20-FR DC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated) RP20-xx3.3SFR Trim up 1 2 3 4 5 6 7 8 9 10 [%] Vout = 3.333 3.366 3.399 3.432 3.465 3.498 3.531 3.564 3.597 3.63 [VDC] RU = 385.07 191.51 126.99 94.73 75.37 62.47 53.25 46.34 40.96 36.66 [kW] 1 2 3 4 5 6 7 8 9 10 [%] Vout = 3.267 3.234 3.201 3.168 3.135 3.102 3.069 3.036 3.003 2.97 [VDC] RD = 116.72 54.78 34.13 23.81 17.62 13.49 10.54 8.33 6.60 5.23 [kW] Trim down RP20-xx05SFR Trim up 1 2 3 4 5 6 7 8 9 10 [%] Vout = 5.05 5.10 5.15 5.20 5.25 5.30 5.35 5.4 5.45 5.50 [VDC] 253.45 125.70 83.18 61.83 49.05 40.53 34.45 29.89 26.34 23.50 [kW] 1 2 3 4 5 6 7 8 9 10 [%] RU = Trim down 4.95 4.90 4.85 4.80 4.75 4.70 4.65 4.60 4.55 4.50 [VDC] 248.34 120.59 78.01 56.72 43.94 35.42 29.34 24.78 21.23 18.39 [kW] 2 3 4 5 6 7 8 9 10 [%] Vout = RD = RP20-xx12SFR Trim up 1 Vout = 12.12 12.24 12.36 12.48 12.60 12.72 12.84 12.96 13.08 13.20 [VDC] RU = 203.22 99.06 64.33 46.97 36.56 29.61 24.65 20.93 18.04 15.72 [kW] 1 2 3 4 5 6 7 8 9 10 [%] Vout = 11.88 11.76 11.64 11.52 11.40 11.28 11.16 11.04 10.92 10.8 [VDC] RD = 776.56 380.72 248.78 182.81 143.22 116.83 97.99 83.84 72.85 64.06 [kW] 2 3 4 5 6 7 8 9 10 [%] Trim down RP20-xx15SFR Trim up 1 Vout = 15.15 15.3 15.45 15.60 15.75 15.90 16.05 16.20 16.35 16.50 [VDC] RU = 161.56 78.22 50.45 36.56 28.22 22.67 18.70 15.72 13.41 11.56 [kW] 1 2 3 4 5 6 7 8 9 10 [%] Trim down Vout = 14.85 14.70 14.55 14.40 14.25 14.10 13.95 13.80 13.65 13.50 [VDC] RD = 818.22 401.56 262.67 193.22 151.56 123.78 103.94 89.06 77.48 68.22 [kW] REGULATIONS Parameter Condition Value Output Accuracy Line Regulation ±1.0% low line to high line, full load Single Dual ±0.2% ±0.5% 0% to 100% load Single Dual ±0.2% ±1.0% 10% to 90% load Single Dual ±0.1% ±0.8% asymmetrical 25%100% load ±5.0% Load Regulation Cross Regulation Transient Response Recovery Time www.recom-power.com 25% load step change REV.: 6/2020 250μs typ. PD-4 RP20-FR DC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated) PROTECTIONS Parameter Condition Value Short Circuit Protection (SCP) Over Voltage Protection (OVP) Over Load Protection (OLP) continuous, automatic recovery 3.3Vout 5Vout 12Vout 15Vout zener diode clamp 3.7VDC - 5.4VDC 5.6VDC - 7.0VDC 13.5VDC - 19.6VDC 16.8VDC - 20.5VDC % Iout rated 150% typ. Isolation Voltage (5) I/P to O/P I/P to O/P to case Isolation Resistance Viso= 500VDC 2.25kVDC/1minute 1.6kVDC/1minute 1GΩ min. Isolation Capacitance 3000pF max. Notes: Note5: For repeat Hi-Pot testing, reduce the time and/or the test voltage Note6: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type ENVIRONMENTAL Parameter Operating Temperature Range Condition Value without derating with derating Maximum Case Temperature +105°C Temperature Coefficient Thermal Impedance Operating Humidity ±0.02%/K max. @ natural convection 0.1m/s without heat-sink with heat-sink non-condensing Environmental testing Part 2-1: Tests Test A: Cold Temperature: -40°C Dwell Time: 2 hours Environmental testing Part 2-2: Tests Test B: Dry heat Temperature: +85°C Dwell Time: 6 hours Temperature: +25 to +55°C Humidity: 90% to 100%RH Test Duration: 24 hours/cycle, 2 cycles, total 48 hours Random vibration test 5Hz to 150Hz, Z-Axis 1.01m/s² (0.103Grms), Y-Axis, X-Axis 0.70m/s² (0.0714Grms), Duration 10min/Axis Environmental testing Part 2-30: Tests Test Db: Damp heat, cyclic (12 h + 12 h cycle) Railway applications – Rolling stock equipment – Shock and vibration tests Fire protection on railway vehicles Fire hazard testing Part 2-11: Glowing/hot-wire based test methods – Glow-wire flammability test method for end-products Fire hazard testing Part 11-10: Test flames – 50 W horizontal and vertical flame test methods -40°C to +79°C -40°C to +101°C 12K/W 10K/W 5% - 95% RH according to EN60068-2-1:2007 according to EN60068-2-2:2007 according to EN60068-2-30:2005 according to EN61373:2010 according to EN45545-2:2013 Oxygen index test Glow-wire test according to EN ISO 4589-2 OI according to EN60695-2-11 Shock according to MIL-STD-810F Thermal Shock according to MIL-STD-810F Vibration according to MIL-STD-810F MTBF according to MIL-HDBK-217F, G.B. 1523 x 103 hours continued on next page www.recom-power.com REV.: 6/2020 PD-5 RP20-FR DC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated) Derating Graph (7) RP20-2415SFR-HC 100 100 80 80 Output Power [%] Output Power [%] RP20-2415SFR 60 40 20 0 -40 -20 0 20 40 60 80 79 Ambient Temperature [°C] 60 40 20 0 -40 100 120 101 -20 0 20 40 60 80 100 120 85 101 Ambient Temperature [°C] Notes: Note7: Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-number not shown here please contact RECOM Techsupport for detailed information SAFETY AND CERTIFICATIONS Certificate Type (Safety) Condition Information Technology Equipment, General Requirements for Safety E196683 Information Technology Equipment, General Requirements for Safety (LVD) TW1708011-001 Railway Applications - Electrical Equipment used on rolling stock 15A100702E-C EAC RU-AT.49.09571 RoHS2 Standard UL60950-1, 2nd Edition, 2014 CAN/CSA-C22.2 No. 60950-1-07, 2nd Edition, 2014 IEC60950-1:2005, 2nd Edition + A2:2013 EN60950-1:2006 + A2:2013 EN50155:2007 TP TC 004/2011 RoHS-2011/65/EU + AM-2015/863 EMC Compliance (Railway) Condition Railway Applications - Electromagnetic Compatibility Standard / Criterion EN50121-3-2:2006 Air ±2, ±4, ±8kV Contact ±2, ±4, ±6kV 20V/m (80-1000MHz) 10V/m (1400-2100MHz) 5V/m (2100-2500MHz) ESD Electrostatic Discharge Immunity Test Radiated, Radio-Frequency, Electromagnetic Field Immunity Test Fast Transient and Burst Immunity (8) Surge Immunity (8) Immunity to Conducted Disturbances, Induced by Radio-Frequency Fields EN61000-4-2, Criteria A EN61000-4-3, Criteria A DC Power Port: ±2kV EN61000-4-4, Criteria A DC Power Port: L-L ±0.5, 1kV DC Power Port: L-E ±0.5, 1, 2kV EN61000-4-5, Criteria A DC Power Port: 10V EN61000-4-6, Criteria A continued on next page www.recom-power.com REV.: 6/2020 PD-6 RP20-FR DC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated) EMC Compliance (Multimedia) Condition Standard / Criterion Industrial, scientific and medical equipment - Radio frequency disturbance characteristics - Limits and methods of measurement without external filter without external filter EN55011, Class A EN55011, Class B Electromagnetic compatibility of multimedia equipment - Emission requirements (24Vin and 48Vin) without external filter without external filter EN55032, Class A EN55032, Class B Electromagnetic compatibility of multimedia equipment - Emission requirements (110Vin) without external filter with external filter EN55032, Class A EN55032, Class B Information Technology Equipment - Immunity Characteristics - Limits and Methods of Measurement EN55024:2010 + A1:2015 ESD Electrostatic Discharge Immunity Test Air ±2, ±4, ±8kV Contact ±2, ±4, ±6kV IEC61000-4-2:2008, Criteria A Radiated, Radio-Frequency, Electromagnetic Field Immunity Test 20V/m (80-1000MHz) IEC61000-4-3:2006 + A2:2010, Criteria A Fast Transient and Burst Immunity DC Power Port: ±2kV IEC61000-4-4:2012, Criteria A Surge Immunity DC Power Port: ±0.5, ±1, ±2kV IEC61000-4-5:2014, Criteria A DC Power Port: 10V IEC61000-4-6:2013, Criteria A 50Hz 1A/m IEC61000-4-8:2009, Criteria A Immunity to Conducted Disturbances, Induced by Radio-Frequency Fields Power Magnetic Field Immunity Notes: Note8: An external input filter capacitor is required if the module has to meet EN61000-4-4, -5 The filter Recom suggests: 24VDC and 48VDC input. Nippon chemi-con KY series, 220μF/100V 110VDC input: Rubycon BXF series, 100µF/250V EMI Filtering according to EN55032 Class B (110Vin Single) +Vin L1 F1 C1 C2 C3 +Vin +Vout -Vin -Vout +Vout C4 -Vin -Vout C5 EMI Filtering according to EN55032 Class B (110Vin Dual) +Vin L1 F1 +Vin C1 C2 C3 +Vout C4 Com -Vin -Vin -Vout +Vout Com -Vout C5 Component List MODEL RP20-110xxSFR RP20-110xxDFR www.recom-power.com C1 C2/C3/C4 C5 L1 39μF/250V Al Cap. (lie down) Rubycon BX 0.47μF/250V 1812 MLCC 1000pF/3kV 1808 MLCC CMC: 470μH ref.: WE-SL5 744272471 REV.: 6/2020 PD-7 RP20-FR DC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated) DIMENSIONS and PHYSICAL CHARACTERISTICS Parameter Type Material Dimensions (LxWxH) Weight Value case base potting without Heat-sink with Heat-sink nickel coated copper FR4 PCB silicone (UL94 V-0) 50.8 x 25.4 x 10.2mm 56.8 x 25.4 x 16.8mm without Heat-sink with Heat-sink 30g 40.89g Dimension Drawing (mm) Pinning Information 5.6 25.4 10.2 50.8 Pin # 1 2 3 4 5 6 15.20 8 x 2.54= 20.32 Single +Vin -Vin +Vout Trim (4) -Vout CTRL(2) Dual +Vin -Vin +Vout Com -Vout CTRL(2) Tolerance:  xx.x= ±0.5mm  xx.xx= ±0.25mm Ø 1.0±0.1 Recommended Footprint Details 2 Bottom View 6 5 2.54 6 2.54 1 12.70 7.62 3 10.2 5.08 2.54 2 4 Top View 1 4 3 5 Dimension Drawing with Heat-sink (mm) 50.8 10.2 16.8 5.85 56.8 15.20 8 x 2.54= 20.32 24.2 5.6 25.4 Top View Heat-sink Ø 1.0±0.1 2.54 2.54 1 REV.: 6/2020 PD-8 6 2 5 2.54 7.62 3 10.2 5.08 www.recom-power.com RP20-FR DC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated) PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) tube tray without heat-sink with heat-sink 255.0 x 55.0 x 22.0mm 302.5 x 222.0 x 20.0mm Packaging Quantity tube tray without heat-sink with heat-sink 9pcs 20pcs Storage Temperature Range Storage Humidity -55°C to +125°C non-condensing 5% - 95% RH The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV.: 6/2020 PD-9
RP20-4815DFR/XC-HC
物料型号:RP20-FR系列

器件简介:这是一系列宽输入电压范围的DC/DC转换器,具有高达89%的效率和2.25kVDC的隔离。它们符合EN50155和UL/IEC/EN60950-1的安全标准,适用于电信和工业应用。

引脚分配:转换器具有6个引脚,包括正负输入电压引脚、正负输出电压引脚、调节引脚和控制逻辑引脚。

参数特性:包括输入电压范围、输出电压和电流、效率、最大电容负载等。

功能详解:转换器提供了单输出和双输出选择,具有正负逻辑控制功能,以及输出电压调节功能。

应用信息:适用于需要安全标准认证的电信和工业应用,特别是110VDC输入版本专为铁路应用设计。

封装信息:转换器尺寸为50.8x25.4x10.2mm(无散热片)或56.8x25.4x16.8mm(有散热片),重量分别为30g和40.89g。
RP20-4815DFR/XC-HC 价格&库存

很抱歉,暂时无法提供与“RP20-4815DFR/XC-HC”相匹配的价格&库存,您可以联系我们找货

免费人工找货
RP20-4815DFR/XC-HC
  •  国内价格 香港价格
  • 20+745.2283420+96.30743

库存:0