Features
•
•
•
•
•
•
Regulated
Converter
4:1 wide input voltage range
1.6kVDC isolation
UL certified
Efficiency up to 88%
Six-sided continuous shield
Available as power module (RPM30-EW)
Description
The RP30-EW series wide input range DC/DC converters are certified to UL 60950-1 and to
cUL 60950-1. This makes them ideal for all telecom and industrial applications where approved safety
standards are required. The industry standard 2” x 1.6” package meets military standards for thermal
shock and vibration tolerance.
DC/DC Converter
RP30-EW
30 Watt
2’’ x 1.6’’
Single and
Dual Output
Selection Guide
Part Number
Input
Output
Output
Input (1) Efficiency (1) Max. Capacitive
Voltage Range Voltage
Current
Current
typ.
Load (2)
[VDC] [VDC] [mA] [mA] [%]
[µF]
RP30-243.3SEW (3,4) 10-40 3.3 6000 948 87
19500
RP30-2405SEW (3,4)
10-40
5
6000
1437
87
10200
RP30-2412SEW (3,4) 10-40 12 2500 1437 87
3300
RP30-2415SEW (3,4) 10-40 15 2000 1420 88
1100
RP30-483.3SEW (3,4) 18-75 3.3 6000 474 87
19500
RP30-4805SEW (3,4) 18-75 5 6000 710 88
10200
RP30-4812SEW (3,4)
18-75
12
2500
718
87
3300
RP30-4815SEW (3,4) 18-75 15 2000 710 88
1100
RP30-2412DEW (3,4) 10-40 ±12 ±1250 1488 84
±1000
RP30-2415DEW (3,4) 10-40 ±15 ±1000 1471 85
±680
RP30-4812DEW (3,4) 18-75 ±12 ±1250 735 85
±1000
RP30-4815DEW (3,4) 18-75 ±15 ±1000 726 86
±680
Notes:
Note1: Maximum values at nominal input voltage and full load
Note2: Max. Cap load is tested at minimum input and constant resistive load
E196683
UL60950-1 certified
EN55032 compliant
Model Numbering
RP30-__ __ _EW/_- _
nom. Input Voltage
Output Voltage
“Package (4)”
“CTRL Logic (3)”
Single or Dual
Notes:
Note3: no suffix for CTRL function with Positive Logic (1=ON, 0=OFF)
add suffix “N” for CTRL function with Negative Logic (0=ON, 1=OFF)
Note4: add suffix “-HC” for premounted Heat-sink with clips
Ordering Examples
RP30-2405SEW = 24V Input, 5V Output, Single, Positive Logic CTRL pin
RP30-4812DEW/N-HC = 48V Input, ±12V Output, Dual, Negative Logic CTRL pin, Heat-sink premounted
www.recom-power.com
REV.: 4/2019
PD-1
RP30-EW
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
BASIC CHARACTERISTICS
Parameter
Input Filter
Condition
Min.
Typ.
Max.
nom. Vin = 24VDC
nom. Vin = 48VDC
10VDC
18VDC
24VDC
48VDC
40VDC
75VDC
LC Type
(5)
Input Voltage Range
100ms max.
nom. Vin = 24VDC
nom. Vin = 48VDC
nom. Vin = 24VDC
DC-DC ON
DC-DC OFF
8VDC
nom. Vin = 48VDC
DC-DC ON
DC-DC OFF
16VDC
Input Surge Voltage
Under Voltage Lockout (UVLO)
50VDC
100VDC
10VDC
18VDC
refer to „OUTPUT VOLTAGE TRIMMING“
Output Voltage Trimming
Input Reflected Ripple Current
-10%
+10%
20mAp-p
(6)
Single
Dual
% of full load
Minimum Load (7)
0%
10%
Power up
ON/OFF CTRL
Start-up Time
10ms
10ms
Positive Logic
DC-DC ON
DC-DC OFF
Open or 3.0VDC < VCTRL< 12VDC
Short or 0VDC < VCTRL< 1.2VDC
Negative Logic
DC-DC ON
DC-DC OFF
Short or 0VDC < VCTRL< 1.2VDC
Open or 3.0VDC < VCTRL< 12VDC
-0.5mA
+0.5mA
ON/OFF CTRL (8)
Input Current of CTRL pin
DC-DC ON
Standby Current
DC-DC OFF
3mA
Internal Operating Frequency
270kHz
measured at 20MHz BW
with a 0.1µF/50V MLCC
Ripple and Noise
Notes:
Note5:
Note6:
Note7:
Note8:
RP30-2405SE
60mVp-p
5Vout
12Vout, 15Vout
75mVp-p
100mVp-p
330kHz
An external filter capacitor is required for normal operation. The capacitor should be capable of handling 1A ripple
current for 48V/24V models . RECOM suggest: Nippon chemi-con KY series, 220μF/100V, ESR 90mΩ
Simulated source impedance of 12μH. 12μH inductor in series with +Vin.
The dual output required a minimum 10% loading on the output to maintain specified regulation.
Operation under no-load condition will not damage these devices, however they may not meet all listed specification
The ON/OFF control function can be positive or negative logic. The pin voltage is referenced to -Vin pin
Efficiency vs. Output Current
95
300kHz
Others
Efficiency vs. Input Voltage
90
90
85
80
Efficiency [%]
Efficiency [%]
85
75
70
65
60
55
10Vin
24Vin
40Vin
50
45
40
10
20
30
40
50
60
70
80
90
80
75
70
65
100
Output Current [%]
60
10
13
16
19
22
25
28
31
34
37
40
Input Voltage [VDC]
continued on next page
www.recom-power.com
REV.: 4/2019
PD-2
RP30-EW
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
RP30-4805SEW
Efficiency vs. Output Current
95
Efficiency vs. Input Voltage
90
90
85
80
Efficiency [%]
Efficiency [%]
85
75
70
65
60
55
18Vin
48Vin
75Vin
50
45
40
10
80
75
70
65
60
20
30
40
50
60
70
80
90
18
100
24
30
36
42
48
54
60
66
72
75
Input Voltage [VDC]
Output Current [%]
OUTPUT VOLTAGE TRIMMING
Output Voltage Trimming
Some single/dual output Powerline converters offer the feature of trimming the output voltage over a certain range around the nominal value by
using external trim resistors. No general equation can be given for calculating the trim resistors, but the following trimtables give typical values for
choosing these trimming resistors. If voltages between the given trim points are required, extrapolate between the two nearest given values to work
out the resistor required or use a variable resistor to set the output voltage. Output can be externally trimmed by using the method shown below.
Trim up
Trim down
Trim
-Vout
RD
RU
+Vout
Trim
RP30-xx3.3SEW
Trim up
1
2
3
4
5
6
7
8
9
10
[%]
Vout =
3.333
3.366
3.399
3.432
3.465
3.498
3.531
3.564
3.597
3.63
[VDC]
RU =
57.93
26.16
15.58
10.28
7.11
4.99
3.48
2.34
1.46
0.75
[kW]
1
2
3
4
5
6
7
8
9
10
[%]
Trim down
Vout =
3.267
3.234
3.201
3.168
3.135
3.102
3.069
3.036
3.003
2.97
[VDC]
RD =
69.47
31.23
18.49
12.12
8.29
5.74
3.92
2.56
1.50
0.65
[kW]
2
3
4
5
6
7
8
9
10
[%]
RP30-xx05SEW
Trim up
1
Vout =
5.05
5.10
5.15
5.20
5.25
5.30
5.35
5.4
5.45
5.50
[VDC]
RU =
36.57
16.58
9.92
6.58
4.59
3.25
2.30
1.59
1.03
0.59
[kW]
1
2
3
4
5
6
7
8
9
10
[%]
Vout =
4.95
4.90
4.85
4.80
4.75
4.70
4.65
4.60
4.55
4.50
[VDC]
RD =
45.53
20.61
12.31
8.15
5.66
4.00
2.81
1.92
1.23
0.68
[kW]
Trim down
continued on next page
www.recom-power.com
REV.: 4/2019
PD-3
RP30-EW
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
RP30-xx12SEW
Trim up
1
2
3
4
5
6
7
8
9
10
[%]
Vout =
12.12
12.24
12.36
12.48
12.60
12.72
12.84
12.96
13.08
13.20
[VDC]
RU =
367.91
165.95
98.64
64.98
44.78
31.32
21.70
14.49
8.88
4.39
[kW]
1
2
3
4
5
6
7
8
9
10
[%]
Vout =
11.88
11.76
11.64
11.52
11.40
11.28
11.16
11.04
10.92
10.8
[VDC]
RD =
460.99
207.95
123.60
81.42
56.12
39.25
27.20
18.16
11.13
5.51
[kW]
Trim down
RP30-xx15SEW
Trim up
1
2
3
4
5
6
7
8
9
10
[%]
Vout =
15.15
15.3
15.45
15.60
15.75
15.90
16.05
16.20
16.35
16.50
[VDC]
RU =
404.18
180.59
106.06
68.80
46.44
31.53
20.88
12.90
6.69
1.72
[kW]
1
2
3
4
5
6
7
8
9
10
[%]
Vout =
14.85
14.70
14.55
14.40
14.25
14.10
13.95
13.80
13.65
13.50
[VDC]
RD =
499.82
223.41
131.27
85.20
57.56
39.14
25.97
16.10
8.42
2.282
[kW]
2
3
4
5
6
7
8
9
10
[%]
Trim down
RP30-xx12DEW
Trim up
1
Vout =
24.24
24.48
24.72
24.96
25.20
25.44
25.68
25.92
26.16
26.40
[VDC]
RU =
218.21
98.10
58.07
38.05
26.04
18.03
12.32
8.03
4.69
2.02
[kW]
1
2
3
4
5
6
7
8
9
10
[%]
Vout =
23.76
23.52
23.28
23.04
22.80
22.56
22.32
22.08
21.84
21.6
[VDC]
RD =
273.44
123.02
72.87
47.80
32.76
22.73
15.57
10.20
6.02
2.67
[kW]
2
3
4
5
6
7
8
9
10
[%]
Trim down
RP30-xx15DEW
Trim up
1
Vout =
30.30
30.60
30.90
31.20
31.50
31.80
32.10
32.40
32.70
33.00
[VDC]
RU =
268.29
120.64
71.43
46.82
32.06
22.21
15.10
9.91
5.81
2.53
[kW]
1
2
3
4
5
6
7
8
9
10
[%]
Trim down
Vout =
29.70
29.40
29.10
28.80
28.50
28.20
27.90
27.60
27.30
27.00
[VDC]
RD =
337.71
152.02
90.13
59.18
40.61
28.23
19.39
12.76
7.60
3.47
[kW]
REGULATIONS
Parameter
Condition
Value
Output Accuracy
Line Regulation
Load Regulation (7)
Cross Regulation
Transient Response Recovery Time
www.recom-power.com
±1.0%
low line to high line, full load
±0.5%
Single
Dual
±0.5%
±1.0%
asymmetrical 25%100% load
±5.0%
0% to 100% load
25% load step change
REV.: 4/2019
250μs typ.
PD-4
RP30-EW
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
PROTECTIONS
Parameter
Condition
Value
Short Circuit Protection (SCP)
continuous, automatic recovery
Over Voltage Protection (OVP)
zener diode clamp
Over Load Protection (OLP)
Over Temperature Protection (OTP)
3.9VDC
6.2VDC
15VDC
18VDC
3.3Vout
5Vout
12Vout
15Vout
% of Iout rated
150% typ.
115°C typ.
I/P to O/P
I/P to O/P to case
Viso= 500VDC
Isolation Voltage (9)
Isolation Resistance
1.6kVDC/ 1 minute
1.6kVDC/ 1 minute
1GΩ min.
Isolation Capacitance
1000pF max.
Notes:
Note9: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note10: This power module is not internally fused. An input line fuse must always be used
ENVIRONMENTAL
Parameter
Condition
Value
without derating
with derating
Operating Temperature Range
-40°C to +70°C
-40°C to +100°C
Maximum Case Temperature
+100°C
Temperature Coefficient
±0.02%/K max.
@ natural convection
0.1m/s
Thermal Impedance
Operating Humidity
without heat-sink
with heat-sink
10K/W
8.24K/W
non-condensing
5% - 95% RH
Thermal Shock
according to MIL-STD-810F
Vibration
according to MIL-STD-810F
MIL-HDBK-217F, G.B.
Bellcore TR-NWT-000332 (11)
MTBF
759.8 x 103 hours
1315 x 103 hours
Derating Graph (12)
RP30-483.3SEW-HC
100
100
80
80
Output Power [%]
Output Power [%]
RP30-483.3SEW
60
40
20
0
-40
-20
0
20
40
60 70 80
60
40
20
0
-40
100 120
-20
0
20
40
60
80
75
100 120
Ambient Temperature [°C]
Ambient Temperature [°C]
Notes:
Note11: BELLCORE TR-NWT-000332. Case l: 50% Stress, Temperature at 40°C (Ground fixed and controlled environment)
Note12: Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-number
not shown here please contact RECOM Techsupport for detailed information
www.recom-power.com
REV.: 4/2019
PD-5
RP30-EW
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Condition
Information Technology Equipment, General Requirements for Safety
Standard
UL60950-1, 2nd Edition 2011
CAN/CSA-C22.2 No. 60950-1, 2nd Edition 2011
E196683
EAC
RU-AT.49.09571
TP TC 004/2011
RoHS2
RoHS-2011/65/EU + AM-2015/863
EMC Compliance
Condition
Standard / Criterion
Electromagnetic compatibility of multimedia equipment - Emission
requirements
with external filter
(see filter suggestion below)
EN55032, Class A and B
ESD Electrostatic discharge immunity test
Air ±8kV and Contact ±6kV
EN61000-4-2, Criteria B
10 V/m
EN61000-4-3, Criteria A
Radiated, radio-frequency, electromagnetic field immunity test
Fast Transient and Burst Immunity
±2kV
EN61000-4-4, Criteria A
±1kV
EN61000-4-5, Criteria B
10 Vr.m.s
EN61000-4-6, Criteria A
100A/m continuous; 1000A/m 1s
EN61000-4-8, Criteria A
(13)
Surge Immunity (13)
Immunity to conducted disturbances, induced by radio-frequency fields
Power Magnetic Field Immunity
Notes:
Note13: An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5. The filter
capacitor Recom suggests: Nippon chemi-con KY series 220μF/100V
EMC Filtering Suggestions according to EN55032
Single
Dual
C3
C3
F1
+Vin
+Vin
C1
+Vout
+Vout
F1
+Vin
+Vin
C2
C1
+Vout
+Vout
C2
Com
Com
-Vin
-Vin
-Vout
+VComponent
in
+Vin
List Class
A
+V
C1
L1
F1
C5
-Vin
RP30-48xxSE
+V
RP30-48xxDE
C
C
C2
3
+Vin
C2
6.8μF/50V, 1812
MLCC
-V
-Vout
out
+V
+Vin
out
C1
-Vin
4
C3/C4
Com
Com
1000pF/2kV,
1808 MLCC-V
-V
in
L1
C2
C3
-Vout
out
+Vout
C1808
4
+V
+V
1000pF/2kV,
MLCC
2.2μF/100V, 1812 MLCC
C1
C2
+Vout
+Vout
C5
N/A
F1
-Vout
C3
F1
+Vin
C1
C4 +V
2.2μF/100V,
1812 outMLCC
in
C1
+Vout
+Vout
C2
RP30-24xxSE
-VRP30-24xxDE
in
-Vout
C4
in
MODEL
-Vin
-Vin
C3
C4
F1
-Vout
in
out
C4
Com
Com
-Vin
-Vin
-V
Single
C6
+Vin
-Vout
out
+Vin
C1
C2
C3
-V
Dual
+Vout
+Vout
L1
F1
+Vin
-Vout
out
C5
C6
L1
F1
-Vin
-Vin
C5
+Vin
C4
C1
C2
C3
+Vout
C4
Com
-Vin
-Vin
-Vout
-Vout
-Vin
-Vin
C6
-Vout
+Vout
Com
-Vout
C6
Component List Class B
MODEL
RP30-24xxSE
RP30-24xxDE
RP30-48xxSE
RP30-48xxDE
C1
6.8μF/50V
1812 MLCC
2.2μF/100V
1812 MLCC
www.recom-power.com
C2
N/A
2.2μF/100V
1812 MLCC
C3
6.8μF/50V
1812 MLCC
2.2μF/100V
1812 MLCC
C4
C5/C6
L1
N/A
1000pF/2kV
1808 MLCC
CMC: 450μH
ref.: WE 7448227005 or ref.: CMC-05
2.2μF/100V
1812 MLCC
1000pF/2kV
1808 MLCC
CMC: 450μH
ref.: WE 7448227005 or ref.: CMC-05
REV.: 4/2019
PD-6
RP30-EW
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
DIMENSIONS and PHYSICAL CHARACTERISTICS
Parameter
Type
Value
Material
case
base
potting
nickel coated copper
FR4 PCB
epoxy (UL94-V0)
Dimensions (LxWxH)
without Heat-sink
with Heat-sink
50.8 x 40.6 x 10.2mm
56.8 x 40.6 x 17.0mm
Weight
without Heat-sink
with Heat-sink
48.0g
69.06g
Dimension Drawing (mm)
Pinning Information
Pin #
1
2
4
5
6
7
8
Single
+Vin
-Vin
CTRL (3)
no Pin
+Vout
-Vout
Trim
Dual
+Vin
-Vin
CTRL (3)
+Vout
Com
-Vout
Trim
Pin Pitch Tolerance ±0.25mm
xx.x = ±0.5mm
xx.xx = ±0.25mm
5.6
40.6
10.2
50.8
2.54
18 x 2.54= 45.72
Ø 1.0±0.1
Recommended Footprint Details
2.54
1
2
2
Bottom View
4
7
2.54
10.16
12.70
6
8
4
1
10.16
17.78
15.24
5.08
17.80
5
Ø1.3 +0.15/-0
7
Top View
6
5
8
continued on next page
www.recom-power.com
REV.: 4/2019
PD-7
RP30-EW
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Dimension Drawing (mm) with Heat-sink
50.8
Pinning Information
40.6
Top View
Heat-sink
Pin #
1
2
4
5
6
7
8
56.8
5.85
5.6
17.0
10.2
Dual
+Vin
-Vin
CTRL (3)
+Vout
Com
-Vout
Trim
Pin Pitch Tolerance ±0.25mm
xx.x = ±0.5mm
xx.xx = ±0.25mm
37.5
2.54
18 x 2.54= 45.72
Ø 1.0±0.1
2.54
5.08
Packaging Dimension
(LxWxH)
1
Packaging Quantity
Storage Temperature
Range
4
Storage Humidity
7
8
10.16
17.78
2
6
Bottom View
2.54
Parameter
10.16
12.70
5
17.80
PACKAGING INFORMATION
15.24
Single
+Vin
-Vin
CTRL (3)
no Pin
+Vout
-Vout
Trim
tube
tray
tube
tray
Ø1.3 +0.15/-0
8
4
Type
2
1
Value
without heat-sink
with heat-sink
Top View
without heat-sink
with heat-sink
non-condensing
7
6
5
255.0 x 54.0 x 22.0mm
302.5 x 222.0 x 20.0mm
5pcs
15pcs
-55°C to +125°C
5% - 95% RH
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 4/2019
PD-8