Features
Regulated
Converter
•
•
•
•
•
•
Wide 4:1 input voltage range
1.6kVDC isolation
UL certified
Efficiency up to 91%
Six-sided continuous shield
No minimum load required
DC/DC Converter
RP30-FW
Description
The RP30-FW series DC/DC converters are designed to meet to UL 60950-1 and to cUL 60950-1.
This makes them ideal for all telecom and industrial applications where approved safety standards
are required. The industry standard 2” x 1” package meets military standards for thermal shock and
vibration tolerance.
Selection Guide
Part Number
Input
Output
Output
Input (1) Efficiency (1) Max. Capacitive
Voltage Range Voltage
Current
Current
typ.
Load (2)
[VDC] [VDC] [mA] [mA] [%]
[µF]
RP30-243.3SFW (3,4) 9-36 3.3 7500 1199 86
20000
RP30-2405SFW (3,4) 9-36
5 6000 1420 88
14400
RP30-2412SFW (3,4) 9-36 12 2500 1404 89
3000
RP30-2415SFW (3,4)
9-36
15
2000
1404
89
2000
RP30-483.3SFW (3,4) 18-75 3.3 7500 600 86
20000
RP30-4805SFW (3,4) 18-75 5 6000 710 88
14400
RP30-4812SFW (3,4) 18-75 12 2500 694 90
3000
RP30-4815SFW (3,4) 18-75 15 2000 687 91
2000
RP30-2405DFW (3,4)
9-36
±5
±3000
1420
88
±3000
RP30-2412DFW (3,4) 9-36 ±12 ±1250 1437 87
±2000
RP30-2415DFW (3,4) 9-36 ±15 ±1000 1437 87
±1300
RP30-4805DFW (3,4) 18-75 ±5 ±3000 710 88
±3000
RP30-4812DFW (3,4) 18-75 ±12 ±1250 710 88
±2000
RP30-4815DFW (3,4) 18-75 ±15 ±1000 710 88
±1300
Notes:
Note1: Maximum values at nominal input voltage and full load
Note2: Max. Cap load is tested at minimum input and constant resistive load
30 Watt
2“ x 1“
Single and Dual
Output
E196683
UL60950-1 certified
EN55032 compliant
Model Numbering
RP30-__ __ _FW/_ _
nom. Input Voltage
Output Voltage
“Package (4)”
“CTRL Logic (3)”
Single or Dual
Notes:
Note3: no suffix for CTRL function with positive logic (1=ON, 0=OFF)
add suffix “N” for CTRL function with negative logic (0=ON, 1=OFF)
Note4: add suffix “-HC” for premounted Heat-sink with clips
Ordering Examples
RP30-2405SFW = 24V input, 5V output, single, positive Logic CTRL pin
RP30-4812DFW/N-HC = 48V input, ±12V output, dual, negative Logic CTRL pin, Heat-sink premounted
www.recom-power.com
REV.: 3/2019
PD-1
RP30-FW
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Max.
nom. Vin = 24VDC
nom. Vin = 48VDC
9VDC
18VDC
24VDC
48VDC
36VDC
75VDC
Input Filter
Pi-Type
Input Voltage Range
100ms max.
nom. Vin = 24VDC
nom. Vin = 48VDC
nom. Vin = 24VDC
DC-DC ON
DC-DC OFF
8VDC
nom. Vin = 48VDC
DC-DC ON
DC-DC OFF
16VDC
Input Surge Voltage
Under Voltage Lockout (UVLO)
50VDC
100VDC
9VDC
18VDC
refer to “OUTPUT VOLTAGE TRIMMING”
Output Voltage Trimming
Input Reflected Ripple Current
-10%
+10%
20mAp-p
(5)
Minimum Load
0%
Power up
ON/OFF CTRL
Start-up Time
30ms
30ms
Positive Logic
DC-DC ON
DC-DC OFF
Negative Logic
DC-DC ON
DC-DC OFF
ON/OFF CTRL (6)
Input Current of CTRL pin
DC-DC ON
Standby Current
DC-DC OFF
Open or 3.0VDC < VCTRL< 12VDC
Short or 0VDC < VCTRL< 1.2VDC
Short or 0VDC < VCTRL< 1.2VDC
Open or 3.0VDC < VCTRL< 12VDC
-0.5mA
+0.5mA
3mA
Internal Operating Frequency
387kHz
measured at 20MHz BW
with a 1µF/50V MLCC
Ripple and Noise
3.3Vout, 5Vout
12Vout, 15Vout
430kHz
473kHz
100mVp-p
150mVp-p
Notes:
Note5: Simulated source impedance of 12μH. 12μH inductor in series with +Vin
Note6: The ON/OFF control function can be positive or negative logic. The pin voltage is referenced to -Vin pin
RP30-2405SFW
Efficiency vs. Input Voltage full load
Efficiency vs. Output Current
95
95
90
90
80
Efficiency [%]
Efficiency [%]
85
75
70
65
60
55
9Vin
24Vin
36Vin
50
45
40
10
20
30
40
50
60
70
80
90
85
80
75
70
65
100
Output Current [%]
18
20
22
24
26
28
30
32
34
36
Input Voltage [VDC]
continued on next page
www.recom-power.com
REV.: 3/2019
PD-2
RP30-FW
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
RP30-4805SFW
Efficiency vs. Output Current
95
Efficiency vs. Input Voltage full load
95
90
90
80
Efficiency [%]
Efficiency [%]
85
75
70
65
60
55
18Vin
48Vin
75Vin
50
45
40
85
80
75
70
65
10
20
30
40
50
60
70
80
90
100
36
40
44
Output Current [%]
48
52
56
60
64
68
72
75
Input Voltage [VDC]
OUTPUT VOLTAGE TRIMMING
Output Voltage Trimming
Single output Powerline converters offer the feature of trimming the output voltage over a certain range around the nominal value by using external
trim resistors. No general equation can be given for calculating the trim resistors, but the following trimtables give typical values for choosing these
trimming resistors. If voltages between the given trim points are required, extrapolate between the two nearest given values to work out the resistor
required or use a variable resistor to set the output voltage. Output can be externally trimmed by using the method shown below.
Trim up
Trim
Trim
Trim down
RD
RU
-Vout
+Vout
RP30-xx3.3SFW
Trim up
1
2
3
4
5
6
7
8
9
10
[%]
Vout =
3.333
3.366
3.399
3.432
3.465
3.498
3.531
3.564
3.597
3.63
[VDC]
RU =
57.93
26.16
15.58
10.28
7.11
4.99
3.48
2.34
1.46
0.75
[kW]
1
2
3
4
5
6
7
8
9
10
[%]
Vout =
3.267
3.234
3.201
3.168
3.135
3.102
3.069
3.036
3.003
2.97
[VDC]
RD =
69.47
31.23
18.49
12.12
8.29
5.74
3.92
2.56
1.50
0.65
[kW]
2
3
4
5
6
7
8
9
10
[%]
Trim down
RP30-xx05SFW
Trim up
1
Vout =
5.05
5.01
5.15
5.20
5.25
5.30
5.35
5.4
5.45
5.50
[VDC]
RU =
36.57
16.58
9.92
6.58
4.59
3.25
2.30
1.59
1.03
0.59
[kW]
1
2
3
4
5
6
7
8
9
10
[%]
Vout =
4.95
4.90
4.85
4.80
4.75
4.70
4.65
4.60
4.55
4.50
[VDC]
RD =
45.53
20.61
12.31
8.15
5.66
4.00
2.81
1.92
1.23
0.68
[kW]
Trim down
continued on next page
www.recom-power.com
REV.: 3/2019
PD-3
RP30-FW
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
RP30-xx12SFW
Trim up
1
2
3
4
5
6
7
8
9
10
[%]
Vout =
12.12
12.24
12.36
12.48
12.60
12.72
12.84
12.96
13.08
13.20
[VDC]
RU =
367.91
165.95
98.64
64.98
44.78
31.32
21.70
14.49
8.88
4.39
[kW]
1
2
3
4
5
6
7
8
9
10
[%]
Vout =
11.88
11.76
11.64
11.52
11.40
11.28
11.16
11.04
10.92
10.8
[VDC]
RD =
460.99
207.95
123.60
81.42
56.12
39.25
27.20
18.16
11.13
5.51
[kW]
Trim down
RP30-xx15SFW
Trim up
1
2
3
4
5
6
7
8
9
10
[%]
Vout =
15.15
15.3
15.45
15.60
15.75
15.90
16.05
16.20
16.35
16.50
[VDC]
RU =
404.18
180.59
106.06
68.80
46.44
31.53
20.88
12.90
6.69
1.72
[kW]
1
2
3
4
5
6
7
8
9
10
[%]
Vout =
14.85
14.70
14.55
14.40
14.25
14.10
13.95
13.80
13.65
13.50
[VDC]
RD =
499.82
223.41
131.27
85.20
57.56
39.14
25.97
16.10
8.42
2.282
[kW]
Trim down
REGULATIONS
Parameter
Condition
Value
Output Accuracy
±1.0% max.
Line Regulation
low line to high line, full load
Load Regulation
Single
Dual
±0.5%
±1.0%
asymmetrical 25%100% load
±5.0%
0% to 100% load
Cross Regulation
Transient Response Recovery Time
±0.2% max.
25% load step change
250μs typ.
PROTECTIONS
Parameter
Condition
Value
Short Circuit Protection (SCP)
continuous, automatic recovery
Over Voltage Protection (OVP)
zener diode clamp
Over Load Protection (OLP)
Over Temperature Protection (OTP)
3.3Vout
5Vout
12Vout
15Vout
% Iout rated
3.9VDC
6.2VDC
15VDC
18VDC
150% typ.
115°C typ.
Isolation Voltage (7)
I/P to O/P
I/P to O/P to case
Isolation Resistance
Viso= 500VDC
Isolation Capacitance
1.6kVDC/ 1 minute
1.6kVDC/ 1 minute
1GΩ min.
1500pF max.
Notes:
Note7: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note8: This power module is not internally fused. An input line fuse must always be used
www.recom-power.com
REV.: 3/2019
PD-4
RP30-FW
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
ENVIRONMENTAL
Parameter
Condition
Value
without derating
with derating
Operating Temperature Range
-40°C to +62°C
-40°C to +101°C
Maximum Case Temperature
+105°C max.
Temperature Coefficient
±0.02%/K max.
@ natural convection
0.1m/s
Thermal Impedance
Operating Humidity
without heat-sink
with heat-sink
12K/W
10K/W
non-condensing
5% - 95% RH
Thermal Shock
according to MIL-STD-810F
Vibration
according to MIL-STD-810F
MIL-HDBK-217F, G.B.
Bellcore TR-NWT-000332 (9)
MTBF
RP30-2412SFW-HC
RP30-2412SFW
100
100
80
80
Output Power [%]
Output Power [%]
Derating Graph (10)
1288 x 103 hours
3163 x 103 hours
60
40
20
0
-40
-20
0
20
40
60
62
80
Ambient Temperature [°C]
60
40
20
0
-40
100 120
101
-20
0
20
40
60
68
100 120
80
Ambient Temperature [°C]
Notes:
Note9: BELLCORE TR-NWT-000332. Case l: 50% Stress, Temperature at 40°C (Ground fixed and controlled environment)
MIL-HDBK-217F, G.B. Notice2 @ TA= 25°C, Full load (Ground, Benign, controlled environment)
Note10: Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-number
not shown here please contact RECOM Techsupport for detailed information
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Condition
Information Technology Equipment, General Requirements for Safety
E196683
EAC
RU-AT.49.09571
RoHS2
Standard
UL60950-1, 2nd Edition 2011
CAN/CSA-C22.2 No. 60950-1, 2nd Edition 2011
TP TC 004/2011
RoHS-2011/65/EU + AM-2015/863
EMC Compliance
Electromagnetic compatibility of multimedia equipment - Emission
requirements
Condition
Standard / Criterion
with external filter
(see filter suggestion below)
EN55032, Class A and B
Information technology equipment - Immunity characteristics - Limits
and methods of measurement
ESD Electrostatic discharge immunity test
EN55024:2010 + A1:2015
Air ±8kV and Contact ±6kV
Radiated, radio-frequency, electromagnetic field immunity test
10 V/m
IEC61000-4-2:2008, Criteria A
IEC61000-4-3:2006 + A2:2010, Criteria A
Fast Transient and Burst Immunity (11)
±2kV
IEC61000-4-4:2012, Criteria A
Surge Immunity (11)
±1kV
IEC61000-4-5:2005, Criteria A
10 Vr.m.s
IEC61000-4-6:2008, Criteria A
Immunity to conducted disturbances, induced by radio-frequency fields
continued on next page
www.recom-power.com
REV.: 3/2019
PD-5
+Vin
RP30-FW
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Notes:
Note11: An external input filter capacitor is required if the module has to meet EN61000-4-4, EN61000-4-5
Recom suggests Nippon chemi-con KY series 24Vin=330μF/50V or 48Vin=220μF/100V
EMC Filtering Suggestions according to EN55032
Single
Dual
C2
C2
F1
+Vin
+Vin
+Vout
+Vout
F1
+Vin
+Vin
C1
C1
Trim
Com
-Vout
-Vin
-Vin
-Vout
-Vin
-Vin
-Vout
C3
F1
in
C2
C3
RP30-48xxSFW
RP30-48xxDFW
C3
Trim
C
-Vin
-Vin
L1
F1
4.7μF/50V
-V+V
out
1812 MLCC
out
L2
C2
-Vout
1000pF/2kV
L1
1808 MLCC
F1
C1
L2
-Vin
C2
1000pF/2kV
1808 MLCC
+Vin
in
+Vout
+Vin
L1
F1
-Vout
C1
L2
C2
-Vin
-Vout
-Vout
-Vout
C4
+Vout
+Vout
C3
Trim
-Vin
+Vout
C6
+Vin
C3
-Vout
Dual
C5
+Vout
+Vout
C4
-Vin
C4
C6
Com
1000pF/2kV
1808 -VMLCC
1000pF/2kV C3
1808 MLCC Com
C3
-Vin
+Vout
+Vout
C4
C1 C3/C4
Single
+Vin
C1
+Vin -Vout
2.2μF/100V
1812 MLCC
-V4out
C5
+Vin
+Vout
+Vin
C2
Trim
-Vin
F1
+Vin
C1
14
C1
+Vout
+Vout
in
F1
C2
C4
+Vin
Component
List Class
+V A
C
C
MODEL
RP30-24xxSFW
L2
RP30-24xxDFW
-Vin +V
-Vout
C3
C2
C4
L1
+Vout
+Vout
Com
-Vout
-Vin
-Vin
-Vout
C5
C5
C6
C6
-Vout
Component List Class B
MODEL
C1/C2/C3
C4/C5/C6
L1
L2
RP30-24xxSFW
RP30-24xxDFW
4.7μF/50V
1812 MLCC
1000pF/2kV
1808 MLCC
CMC: 33.3μH
ref.: WE 744842932 ref.: CMC-09
CMC: 55μH
ref.: WE 744290560 ref.: CMC-10
RP30-48xxSFW
RP30-48xxDFW
2.2μF/100V
1812 MLCC
1000pF/2kV
1808 MLCC
CMC: 33.3μH
ref.: WE 744842932 ref.: CMC-09
CMC: 55μH
ref.: WE 744290560 ref.: CMC-10
DIMENSIONS and PHYSICAL CHARACTERISTICS
Parameter
Material
Dimensions (LxWxH)
Weight
Type
Value
case
base
potting
without Heat-sink
with Heat-sink
nickel coated copper
FR4 PCB
epoxy (UL94V-0)
50.8 x 25.4 x 10.2mm
56.8 x 25.4 x 16.8mm
without Heat-sink
with Heat-sink
30.5g
41.39g
continued on next page
www.recom-power.com
REV.: 3/2019
PD-6
RP30-FW
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Dimension Drawing (mm)
Pinning Information
18 x 2.54= 45.72
5.6
25.4
10.2
50.8
Pin #
1
2
3
4
5
6
Single
+Vin
-Vin
CTRL (3)
+Vout
-Vout
Trim
Dual
+Vin
-Vin
CTRL (3)
+Vout
Com
-Vout
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.25mm
2.54
Ø 1.0±0.1
Recommended Footprint Details
7.62
4
2
15.24
6
3
2.54
1
Bottom View
2.54
5.08
5.08
2.54
Top View
5
2
5
1
3
6
4
Dimension Drawing with Heat-sink (mm)
50.8
24.2
10.2
16.8
5.85
56.8
18 x 2.54= 45.72
5.6
25.4
Top View
Heat-sink
2.54
Ø 1.0±0.1
2.54
2
Bottom View
6
3
5
2
Top View
5
1
3
6
www.recom-power.com
2.54
2.54
4
1
15.24
7.62
5.08
5.08
Recommended Footprint Details
4
REV.: 3/2019
PD-7
RP30-FW
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
PACKAGING INFORMATION
Parameter
Type
Value
Packaging Dimension (LxWxH)
tube
tray
without heat-sink
with heat-sink
255.0 x 54.0 x 22.0mm
302.5 x 222.0 x 20.0mm
Packaging Quantity
tube
tray
without heat-sink
with heat-sink
9pcs
20pcs
Storage Temperature Range
Storage Humidity
-55°C to +125°C
non-condensing
5% - 95% RH
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 3/2019
PD-8