Features Regulated Converter • Wide 4:1 input voltage range • 1.6kVDC isolation for 24Vin and 48Vin, 3kVDC isolation for 110Vin • Efficiency up to 92% • Six-sided continuous shield • EN50155, UL/IEC/EN60950-1 certified Description DC/DC Converter RP40-FR 40 Watt 3 2“ x 1“ Single and Dual Output YEA R Selection Guide y arrant w The RP40-FR series wide range input DC/DC converters have been especially designed for railway applications and are EN50155 certified. They are also certified to UL60950-1 and cUL 60950-1, this makes them ideal for all high input voltage telecom and industrial applications where approved safety standards are required. T T TS RE TS CONVER S C M R M O E 10 from 10 PL U D IA N T PRO C C CONVER CO Notes: Note1: Maximum values at nominal input voltage and full load at +25°C ambient Note2: Max. Cap load is tested at minimum input and constant resistive load M S CO M O R C E RE Part Number Input Output Output Input (1) Efficiency (1) Max. Capacitive Voltage Range Voltage Current Current typ. Load (2) [VDC] [VDC] [mA] [mA] [%] [µF] RP40-243.3SFR (3,4) 9-36 3.3 10000 1528 90 26600 RP40-2405SFR (3,4) 9-36 5 8000 1832 91 20000 RP40-2412SFR (3,4) 9-36 12 3333 1811 92 3900 RP40-2415SFR (3,4) 9-36 15 2666 1811 92 2600 RP40-2424SFR (3,4) 9-36 24 1666 1831 91 1300 RP40-483.3SFR (3,4) 18-75 3.3 10000 764 90 26600 RP40-4805SFR (3,4) 18-75 5 8000 916 91 20000 RoHS 2 + REACH compliant RP40-4812SFR (3,4) 18-75 12 3333 906 92 3900 compliant E196683 (3,4) RP40-4815SFR 18-75 15 2666 906 92 2600 (3,4)  RP40-4824SFR 18-75 24 1666 915 91 1300 RP40-1103.3SFR (3,4) 43-160 3.3 10000 341 88 26600 RP40-11005SFR (3,4) 43-160 5 8000 409 89 20000 RP40-11012SFR (3,4) 43-160 12 3333 402 90.5 3900 RP40-11015SFR (3,4) 43-160 15 2666 400 91 2600 EN50155 certified RP40-11024SFR (3,4) 43-160 24 1666 404 90 1300 UL60950-1 certified RP40-2412DFR (3,4) 9-36 ±12 ±1666 1851 90 ±2600 IEC/EN60950-1 certified RP40-2415DFR (3,4) 9-36 ±15 ±1333 1851 90 ±1600 EN55032 compliant RP40-2424DFR (3,4) 9-36 ±24 ±833 1830 91 ±650 EN55024 compliant RP40-4812DFR (3,4) 18-75 ±12 ±1666 925 90 ±2600 EN50121-3-2 compliant RP40-4815DFR (3,4) 18-75 ±15 ±1333 741 90 ±1600 RP40-4824DFR (3,4) 18-75 ±24 ±833 572 91 ±650 RP40-11012DFR (3,4) 43-160 ±12 ±1666 408 89 ±2600 RP40-11015DFR (3,4) 43-160 ±15 ±1333 408 89 ±1600 RP40-11024DFR (3,4) 43-160 ±24 ±833 400 91 ±650 PL U D IA N T PRO REF DESIGN available Model Numbering RP40-__ __ _FR/_- _ nom. Input Voltage nom. Output Voltage “Package ” (4) “CTRL Logic (3)” Single or Dual Notes: Note3: standard part is with suffix “P” for positive logic (1=ON, 0=OFF) or add suffix “N” instead for negative logic (0=ON, 1=OFF) Note4: add suffix “-HC” for premounted Heat-sink with clips Ordering Examples RP40-2405SFR/P = 24V input, 5V output, single, positive Logic CTRL pin RP40-4812DFR/N-HC = 48V input, ±12V output, dual, negative Logic CTRL pin, Heat-sink premounted www.recom-power.com REV.: 8/2020 https://recom-power.com/ rec-s-R-REF04-RIA12.html SURGE PROTECTOR available https://recom-power.com/rec-sRSPxxx-168.html PD-1 RP40-FR DC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated) BASIC CHARACTERISTICS Parameter Condition Min. Typ. nom. Vin = 24VDC nom. Vin = 48VDC nom. Vin = 110VDC 9VDC 18VDC 43VDC 24VDC 48VDC 110VDC Max. Internal Input Filter Input Voltage Range nom. Vin = 24VDC nom. Vin = 48VDC nom. Vin = 110VDC DC-DC ON DC-DC OFF 8VDC nom. Vin = 48VDC DC-DC ON DC-DC OFF 16VDC nom. Vin = 110VDC DC-DC ON DC-DC OFF 40VDC Input Surge Voltage 1s max. nom. Vin = 24VDC Under Voltage Lockout (UVLO) 18VDC 43VDC 3.3Vout, 5Vout, 12Vout 15Vout, 24Vout refer to Output Voltage Trimming „OUTPUT VOLTAGE TRIMMING“ -10% -10% +10% +20% Power up ON/OFF CTRL Start-up Time 60ms 60ms Open or 3.0VDC < VCTRL< 12VDC Short or 0VDC < VCTRL< 1.2VDC Short or 0VDC < VCTRL< 1.2VDC Open or 3.0VDC < VCTRL< 12VDC Positive Logic DC-DC ON DC-DC OFF Negative Logic DC-DC ON DC-DC OFF Input Current of CTRL pin drive current ICTRL Standby Current DC-DC OFF IIn measured by 20MHz bandwidth with a 1µF/50V X7R MLCC 3.3Vout, 5Vout 12Vout, 15Vout 24Vout ON/OFF CTRL refer to “ON/OFF CTRL” (5) -0.5mA +0.5mA 3mA Internal Operating Frequency 225kHz Output Ripple and Noise Pi-Type 36VDC 75VDC 160VDC 50VDC 100VDC 170VDC 9VDC 250kHz 75mVp-p 100mVp-p 150mVp-p 30mAp-p Input Reflected Ripple Current 275kHz 100mVp-p 125mVp-p 200mVp-p Notes: Note5: The ON/OFF control function can be positive or negative logic. The pin voltage is referenced to -Vin pin RP40-2405SFR Efficiency vs. Output Current 90 90 80 80 70 70 60 50 40 30 9Vin 24Vin 36Vin 20 10 0 10 20 30 40 50 60 70 80 Efficiency vs. Input Voltage 100 Efficiency [%] Efficiency [%] 100 90 60 50 40 30 20 10 0 100 Output Current [%] 9 12 15 18 21 24 27 30 33 36 Input Voltage [VDC] continued on next page www.recom-power.com REV.: 8/2020 PD-2 RP40-FR DC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated) RP40-4805SFR Efficiency vs. Output Current 90 90 80 80 70 70 60 50 40 30 18Vin 48Vin 75Vin 20 10 0 10 20 30 40 50 60 70 80 Efficiency vs. Input Voltage 100 Efficiency [%] Efficiency [%] 100 90 60 50 40 30 20 10 0 100 18 24 30 36 Output Current [%] 42 48 54 60 66 72 75 143 160 Input Voltage [VDC] RP40-11005SFR 100 90 90 80 80 70 70 Efficiency [%] Efficiency [%] Efficiency vs. Output Current 100 60 50 40 30 43Vin 110Vin 160Vin 20 10 0 10 20 30 40 50 60 70 80 90 Efficiency vs. Input Voltage 60 50 40 30 20 10 0 100 43 52 62 Output Current [%] 72 84 96 110 125 136 Input Voltage [VDC] OUTPUT VOLTAGE TRIMMING Output Voltage Trimming Single output Powerline converters offer the feature of trimming the output voltage over a certain range around the nominal value by using external trim resistors. No general equation can be given for calculating the trim resistors, but the following trimtables give typical values for chosing these trimming resistors. If voltages between the given trim points are required, extrapolate between the two nearest given values to work out the resistor required or use a variable resistor to set the output voltage. Output can be externally trimmed by using the method shown below. Trim up Trim down Trim Trim RD RU -Vout +Vout continued on next page www.recom-power.com REV.: 8/2020 PD-3 RP40-FR DC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated) RP40-xx3.3SFR Trim up 1 2 3 4 5 6 7 8 9 10 [%] Vout = 3.333 3.366 3.399 3.432 3.465 3.498 3.531 3.564 3.597 3.63 [VDC] RU = 57.93 26.16 15.58 10.28 7.11 4.99 3.48 2.34 1.46 0.75 [kW] 1 2 3 4 5 6 7 8 9 10 [%] Vout = 3.267 3.234 3.201 3.168 3.135 3.102 3.069 3.036 3.003 2.97 [VDC] RD = 69.47 31.23 18.49 12.12 8.29 5.74 3.92 2.56 1.50 0.65 [kW] 2 3 4 5 6 7 8 9 10 [%] Trim down RP40-xx05SFR Trim up 1 Vout = 5.05 5.10 5.15 5.20 5.25 5.30 5.35 5.4 5.45 5.50 [VDC] RU = 36.57 16.58 9.92 6.89 4.59 3.25 2.30 1.59 1.03 0.59 [kW] 1 2 3 4 5 6 7 8 9 10 [%] 4.95 4.90 4.85 4.80 4.75 4.70 4.65 4.60 4.55 4.50 [VDC] 45.533 20.612 12.306 8.152 5.66 3.999 2.812 1.922 1.23 0.676 [kW] 2 3 4 5 6 7 8 9 10 [%] Trim down Vout = RD = RP40-xx12SFR Trim up 1 Vout = 12.12 12.24 12.36 12.48 12.60 12.72 12.84 12.96 13.08 13.20 [VDC] RU = 367.91 165.95 98.636 64.977 44.782 31.318 21.701 14.488 8.879 4.391 [kW] 1 2 3 4 5 6 7 8 9 10 [%] Trim down Vout = 11.88 11.76 11.64 11.52 11.40 11.28 11.16 11.04 10.92 10.8 [VDC] RD = 460.99 207.95 123.6 81.423 56.118 39.249 27.199 18.162 11.132 5.509 [kW] RP40-xx15SFR Trim up 1 2 3 4 5 6 7 8 9 10 [%] Vout = 15.15 15.3 15.45 15.60 15.75 15.90 16.05 16.20 16.35 16.50 [VDC] RU = 419.81 199.91 126.60 89.95 67.96 53.30 42.83 34.98 28.87 23.98 [kW] Trim up 11 12 13 14 15 16 17 18 19 20 [%] Vout = 16.650 16.800 16.950 17.100 17.250 17.400 17.550 17.700 17.850 18.000 [VDC] RU = 19.98 16.65 13.83 11.42 9.32 7.49 5.87 4.43 3.15 1.99 [kW] 1 2 3 4 5 6 7 8 9 10 [%] Vout = 14.85 14.70 14.55 14.40 14.25 14.1 13.95 13.8 13.65 13.5 [VDC] RD = 284.89 128.68 76.61 50.58 34.96 24.55 17.11 11.53 7.19 3.72 [kW] 2 3 4 5 6 7 8 9 10 [%] Trim down RP40-xx24SFR Trim up 1 Vout = 24.240 24.480 24.720 24.960 25.200 25.440 25.680 25.920 26.160 26.400 [VDC] RU = 1275.2 606.60 383.73 272.30 205.44 160.87 129.03 105.15 86.58 71.72 [kW] Trim up 11 12 13 14 15 16 17 18 19 20 [%] Vout = 26.640 26.880 27.120 27.360 27.600 27.840 28.080 28.320 28.560 28.800 [VDC] RU = 59.56 49.43 40.86 33.51 27.15 21.57 16.66 12.29 8.38 4.86 [kW] 1 2 3 4 5 6 7 8 9 10 [%] Trim down Vout = 23.760 23.520 23.280 23.040 22.800 22.560 22.320 22.080 21.840 21.600 [VDC] RD = 838.15 376.78 222.98 146.09 99.95 69.19 47.22 30.74 17.93 7.68 [kW] www.recom-power.com REV.: 8/2020 PD-4 RP40-FR DC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated) ON/OFF CTRL IIN +Vin ICTRL VCTRL +Vin +Vout Positve Logic DC-DC ON DC-DC OFF Open or 3.0VDC < VCTRL < 12VDC Short or 0VDC < VCTRL < 1.2VDC Negative Logic DC-DC ON DC-DC OFF Short or 0VDC < VCTRL < 1.2VDC Open or 3.0VDC < VCTRL < 12VDC CTRL -Vin -Vin +Vout -Vout -Vout REGULATIONS Parameter Condition Value Output Accuracy ±1.0% Line Regulation low line to high line, full load Load Regulation 0% to 100% load Cross Regulation ±0.2% Single Dual ±0.5% ±1.0% asymmetrical 25%100% load Transient Response Recovery Time ±5.0% 25% load step change 250μs typ. PROTECTIONS Parameter Condition Value Short Circuit Protection (SCP) Over Voltage Protection (OVP) Over Load Protection (OLP) continuous, automatic recovery 3.9VDC 6.2VDC 15VDC 20VDC 30VDC 3.3Vout 5Vout 12Vout 15Vout 24Vout zener diode clamp % Iout rated 150% typ., Hiccup mode Over Temperature Protection (OTP) 115°C typ. nom. Vin = 24, 48VDC I/P to O/P I/P to O/P to Case 1.6kVDC/1min. 1.6kVDC/1min. nom. Vin = 110VDC I/P to O/P I/P to O/P to Case 3kVDC/1min. 1.6kVDC/1min. Isolation Voltage (6) Isolation Resistance Viso= 500VDC Isolation Capacitance 1GΩ min. 1500pF max. Notes: Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage Note7: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type www.recom-power.com REV.: 8/2020 PD-5 RP40-FR DC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated) ENVIRONMENTAL Parameter Condition Value without derating with derating Operating Temperature Range -40°C to +60°C -40°C to +105°C Maximum Case Temperature +105°C Temperature Coefficient ±0.02%/K max. Thermal Impedance @ natural convection 0.1m/s Operating Humidity without heat-sink with heat-sink 10.8K/W 10.3K/W non-condensing 5% - 95% RH Environmental testing Part 2-1: Tests Test A: Cold Storage temperature -40°C, 16 hours Operating temperature -40°C, 2 hours according to EN60068-2-1:2007 Environmental testing Part 2-2: Tests Test B: Dry heat Temperature +85°C, 6 hours according to EN60068-2-2:2007 Temperature: +25 to +55°C Humidity: 90%+/-5% RH Test Duration: 48 hours Random vibration test 5Hz to 150Hz, Z-Axis 1.01m/s² (0.103Grms), Y-Axis, X-Axis 0.70m/s² (0.0714Grms), Duration 10min/Axis Environmental testing Part 2-30: Tests Test Db: Damp heat, cyclic (12 h + 12 h cycle) Railway applications – Rolling stock equipment – Shock and vibration tests according to EN60068-2-30:2005 according to EN61373:2010 Fire protection on railway vehicles according to EN45545-2:2013 Fire hazard testing Part 2-11: Glowing/hot-wire based test methods – Glow-wire flammability test method for end-products Fire hazard testing Part 11-10: Test flames – 50 W horizontal and vertical flame test methods Oxygen index test according to EN ISO 4589-2 OI Glow-wire test according to EN60695-2-11 Shock according to MIL-STD-810F Thermal Shock according to MIL-STD-810F Vibration according to MIL-STD-810F MTBF according to MIL-HDBK-217F, G.B 907.3 x 103 hours Derating Graph (8) (@ Chamber and natural convection 0.1m/s) RP40-2415SFR-HC 100 100 80 80 Output Power [%] Output Power [%] RP40-2415SFR 60 40 20 0 -40 -20 0 20 40 60 60 40 20 0 -40 80 100 120 105 -20 0 20 40 60 80 100 120 105 65 Ambient Temperature [°C] Ambient Temperature [°C] Notes: Note8: Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-number not shown here please contact RECOM Techsupport for detailed information www.recom-power.com REV.: 8/2020 PD-6 RP40-FR DC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated) SAFETY AND CERTIFICATIONS Certificate Type (Safety) Condition Information Technology Equipment, General Requirements for Safety E196683 Information Technology Equipment, General Requirements for Safety (LVD) TW1708011-001 Standard UL60950-1, 2nd Edition, 2014 CAN/CSA-C22.2 No. 60950-1-07, 2nd Edition, 2014 IEC60950-1:2005, 2nd Edition + A2:2013 EN60950-1:2006 + A2:2013 Railway Applications - Electrical Equipment used on rolling stock 15A100702E-C EN50155:2007 EAC RU-AT.49.09571 TP TC 004/2011 RoHS2 RoHS-2011/65/EU + AM-2015/863 EMC Compliance (Railway) Condition “refer to EMC filtering” Railway Applications - Electromagnetic Compatibility Industrial, Scientific and Medical Equipment – Radio Frequency Disturbance Characteristics – Limits and Methods of Measurement Standard / Criterion EN50121-3-2:2006 EN55011 ESD Electrostatic Discharge Immunity Test Air ±2, ±4, ±8kV Contact ±2, ±4, ±6kV EN61000-4-2, Criteria A Radiated, Radio-Frequency, Electromagnetic Field Immunity Test 20V/m (80-1000MHz) EN61000-4-3, Criteria A Fast Transient and Burst Immunity (9) Surge Immunity (9) Immunity to Conducted Disturbances, Induced by Radio-Frequency Fields EMC Compliance (Multimedia) Electromagnetic Compatibility of Multimedia Equipment - Emission Requirements DC Power Port: ±2kV EN61000-4-4, Criteria A DC Power Port: L-L ±0.5, 1kV DC Power Port: L-E ±0.5, 1, 2kV EN61000-4-5, Criteria A DC Power Port: 10V EN61000-4-6, Criteria A Condition Standard / Criterion with external filter “refer to EMC filtering” EN55032, Class A and B Information Technology Equipment - Immunity Characteristics - Limits and Methods of Measurement EN55024:2010 + A1:2015 ESD Electrostatic Discharge Immunity Test Air ±2, ±4, ±8kV Contact ±2, ±4, ±6kV IEC61000-4-2:2008, Criteria A Radiated, Radio-Frequency, Electromagnetic Field Immunity Test 20V/m (80-1000MHz) IEC61000-4-3:2006 + A2:2010, Criteria A DC Power Port: ±2kV IEC61000-4-4:2012, Criteria A DC Power Port: ±0.5, ±1, ±2kV IEC61000-4-5:2014, Criteria A Fast Transient and Burst Immunity Surge Immunity Immunity to Conducted Disturbances, Induced by Radio-Frequency Fields Power Magnetic Field Immunity DC Power Port: 10V IEC61000-4-6:2013, Criteria A 50Hz 100A/m, 1000A/m IEC61000-4-8:2009, Criteria A Notes: Note9: An external input filter capacitor is required if the module has to meet EN61000-4-4 and -4-5. The RP40-24xxFR requires an aluminum electrolytic capacitor (Nippon chemi-con KY series, 220μF/100V) and a TVS (SMDJ58A, 58V, 3000Watt peak pulse power) connected in parallel. The RP40-48xxFR requires an aluminum electrolytic capacitor (Nippon chemi-con KY series, 220μF/100V) and a TVS (SMDJ120A,120V, 3000Watt peak pulse power) connected in parallel. The RP40-110xxFR requires 3pcs aluminum electrolytic capacitor in parallel (Ruby-con BXF series, 68μF/200V) and two TVS (SMDJ90A, 90V, 3000Watt peak pulse power) in series, connected in parallel. continued on next page www.recom-power.com REV.: 8/2020 PD-7 RP40-FR DC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated) EMC Filtering according to EN50121-3-2 (Single Outputs) C7 L1 +VIN C1(9) C2 C4 C3 LOAD TVS1(9) TVS2(9) -VIN C6 C5 EMC Filtering according to EN50121-3-2 (Dual Outputs) C7 L1 TVS1(9) C1(9) C2 C3 LOAD +VIN C4 LOAD TVS2(9) -VIN C6 C5 Component List MODEL TVS1 TVS2 RP40-24xxS_DFR SMDJ58A 58V, 3000W peak pulse power RP40-48xxS_DFR SMDJ120A 120V, 3000W peak pulse power RP40-110xxS_DFR SMDJ90A SMDJ90A 90V, 3000W 90V, 3000W peak pulse power peak pulse power C1(9) C2 C3 C4 10µF/50V 1210 MLCC N/A 220µF/100V N/A N/A 4.7µF/100V 1210 MLCC 68µF/200V 3 in parallel 33µF/250V 1µF/250V Al Cap. (lie down) 1812 MLCC Chemi-con KXJ C5, C6, C7 680pF/3kV 1808 MLCC L1 2.2µH 11A SMD-Inductor 12µH 4A SMD-Inductor 1000pF 1µF/250V 22µH 1.5A TDK CD series 1812 MLCC SMD-Inductor Y1 continued on next page www.recom-power.com REV.: 8/2020 PD-8 RP40-FR DC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated) EMC Filtering according to EN55032 Class A (Single Outputs) C8 L1 Fuse C1 C2 C3 C4 C5 LOAD +VIN -VIN C7 C6 EMC Filtering according to EN55032 Class A (Dual Outputs) C8 L1 Fuse C2 C3 C4 C5 LOAD C1 LOAD +VIN -VIN C7 C6 Component List MODEL C1 RP40-24xxS_DFR 10µF/50V 1210 MLCC RP40-48xxS_DFR 4.7µF/100V 1210 MLCC RP40-110xxS_DFR N/A C2 N/A C3 N/A 33µF/250V Al Cap. (lie down) Chemi-con KXJ C4 C5 N/A 10µF/50V 1210 MLCC 4.7µF/100V 1210 MLCC 1µF/250V 1812 MLCC C6 C7 680pF/3kV 1808 MLCC 1000pF TDK CD series Y1 C8 L1 2.2µH 11A SMD Inductor 12µH 4A SMD Inductor 22µH 1.5A SMD Inductor continued on next page www.recom-power.com REV.: 8/2020 PD-9 RP40-FR DC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated) EMC Filtering according to EN55032 Class B (24Vin and 48Vin, Single Outputs) C5 L2 L1 Fuse C1 C3 C2 LOAD +VIN -VIN C7 C6 C4 EMC Filtering according to EN55032 Class B (24Vin and 48Vin, Dual Outputs) C5 L2 L1 Fuse C1 LOAD +VIN C3 LOAD C2 -VIN C7 C6 C4 Component List MODEL C1/C2 RP40-24xxS_DFR 10µF/50V 1210 MLCC RP40-48xxS_DFR 4.7µF/100V 1210 MLCC C3 C4/C6 82µF/100V Al Cap. (lie down) Chemi-con KJ 1000pf/3kV 1808 MLCC C5/C7 2200pf/3kV 1808 MLCC L1/L2 3.3µH 10A SMD Inductor 12µH 4A SMD Inductor continued on next page www.recom-power.com REV.: 8/2020 PD-10 RP40-FR DC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated) EMC Filtering according to EN55032 Class B (110Vin Single Outputs) C7 L2 L1 Fuse C1 C2 C4 C3 C5 C6 LOAD +VIN -VIN C9 C8 EMC Filtering according to EN55032 Class B (110Vin Dual Outputs) C7 L2 L1 Fuse C2 C4 C3 C5 C6 LOAD C1 LOAD +VIN -VIN C9 C8 Component List MODEL RP40-110xxS_DFR C1 C2/C3 C4 C5/C6 C7/C8/C9 L1/L2 33µF/250V Al Cap. (lie down) Chemicon -KXJ 1µF/250V 1812 MLCC 33µF/250V Al Cap. (lie down) Chemicon -KXJ 1µF/250V 1812 MLCC 2200pF TDK CD series Y1 22µH 1.5A SMD Inductor DIMENSIONS AND PHYSICAL CHARACTERISTICS Parameter Material Dimensions (LxWxH) Weight Type Value case base potting without Heat-sink with Heat-sink copper alloy (CuZn33) FR4 PCB silicone (UL94 V-0) 50.8 x 25.4 x 10.2mm 56.8 x 25.4 x 16.8mm without Heat-sink with Heat-sink 32g 43g continued on next page www.recom-power.com REV.: 8/2020 PD-11 RP40-FR DC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated) Dimension Drawing (mm) Pinning Information 18 x 2.54= 45.72 5.6 25.4 10.2 50.8 Pin # 1 2 3 4 5 6 2.5 Ø 1.0 7.62 5.1 15.24 6 3 2.54 2 Bottom View 2.54 2.54 5.08 4 Dual +Vin -Vin CTRL (3) +Vout Com -Vout Tolerance:  xx.x= ±0.5mm  xx.xx= ±0.25mm ±0.1 Recommended Footprint Details 1 Single +Vin -Vin CTRL (3) +Vout -Vout Trim Top View 5 2 5 1 3 4 2.54 6 Dimension Drawing with Heat-sink (mm) 50.8 10.2 16.8 18 x 2.54= 45.72 2.54 PACKAGING INFORMATION 15.24 2.54 Bottom View 5 Packaging Quantity 3 Storage Temperature Range Storage Humidity 6 Type tube tray 3 tube tray 2 1 Value 6 without heat-sink with heat-sink Top View without heat-sink with heat-sink non-condensing 2.54 7.62 4 1 Packaging Dimension 2 (LxWxH) Ø 1.0±0.1 2.54 5.08 5.08 Parameter 24.2 5.85 56.8 5.6 25.4 Top View Heat-sink 5 4 255.0 x 54.0 x 22.0mm 302.5 x 222.0 x 20.0mm 9pcs 20pcs -55°C to +125°C 5% - 95% RH The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV.: 8/2020 PD-12
RP40-1103.3SFR/N-HC
物料型号:RP40-FR系列

器件简介:RP40-FR系列宽输入电压范围DC/DC转换器专为铁路应用设计,并通过EN50155认证。它们也通过了UL60950-1和cUL 60950-1认证,适用于所有需要批准安全标准的高输入电压电信和工业应用。

引脚分配:文档提供了单输出和双输出配置的引脚分配信息,包括输入电压(+Vin, -Vin)、控制引脚(CTRL)、输出电压(+Vout, -Vout)以及用于输出电压调节的Trim引脚。

参数特性:包括输入电压范围、输出电压、输出电流、输入电流、典型效率、最大电容负载等。

功能详解:文档详细描述了内部输入滤波器、输入浪涌电压、欠压锁定(UVLO)、输出电压调节、启动时间、控制引脚功能、待机电流、内部工作频率、输出纹波和噪声、输入反射纹波电流等。

应用信息:适用于铁路应用和电信工业应用,其中提到了EN50155、UL/IEC/EN60950-1认证。

封装信息:提供了转换器的尺寸、重量、材料信息,以及是否带有散热片的尺寸差异。
RP40-1103.3SFR/N-HC 价格&库存

很抱歉,暂时无法提供与“RP40-1103.3SFR/N-HC”相匹配的价格&库存,您可以联系我们找货

免费人工找货
RP40-1103.3SFR/N-HC
  •  国内价格 香港价格
  • 20+1171.3713120+151.53476

库存:0