Features
Regulated
Converter
• Wide 4:1 input voltage range
• 1.6kVDC isolation for 24Vin and 48Vin,
3kVDC isolation for 110Vin
• Efficiency up to 92%
• Six-sided continuous shield
• EN50155, UL/IEC/EN60950-1 certified
Description
DC/DC Converter
RP40-FR
40 Watt
3
2“ x 1“
Single and Dual
Output
YEA R
Selection Guide
y
arrant
w
The RP40-FR series wide range input DC/DC converters have been especially designed for railway
applications and are EN50155 certified. They are also certified to UL60950-1 and cUL 60950-1, this
makes them ideal for all high input voltage telecom and industrial applications where approved safety
standards are required.
T
T
TS
RE
TS
CONVER
S
C
M
R
M
O
E
10 from 10
PL
U
D
IA N
T PRO
C
C
CONVER
CO
Notes:
Note1: Maximum values at nominal input voltage and full load at +25°C ambient
Note2: Max. Cap load is tested at minimum input and constant resistive load
M
S
CO
M
O
R
C
E
RE
Part Number
Input
Output
Output
Input (1) Efficiency (1) Max. Capacitive
Voltage Range Voltage
Current
Current
typ.
Load (2)
[VDC] [VDC] [mA] [mA] [%]
[µF]
RP40-243.3SFR (3,4) 9-36
3.3 10000 1528 90
26600
RP40-2405SFR (3,4)
9-36
5
8000
1832
91
20000
RP40-2412SFR (3,4) 9-36 12 3333 1811 92
3900
RP40-2415SFR (3,4) 9-36 15 2666 1811 92
2600
RP40-2424SFR (3,4)
9-36 24 1666 1831 91
1300
RP40-483.3SFR (3,4) 18-75 3.3 10000 764 90
26600
RP40-4805SFR (3,4) 18-75 5 8000 916 91
20000
RoHS 2 +
REACH
compliant
RP40-4812SFR (3,4)
18-75
12
3333
906
92
3900
compliant
E196683
(3,4)
RP40-4815SFR 18-75 15 2666 906 92
2600
(3,4)
RP40-4824SFR
18-75 24 1666 915 91
1300
RP40-1103.3SFR (3,4)
43-160 3.3 10000 341 88
26600
RP40-11005SFR (3,4) 43-160 5 8000 409 89
20000
RP40-11012SFR (3,4) 43-160 12 3333 402 90.5
3900
RP40-11015SFR (3,4) 43-160 15 2666 400 91
2600
EN50155 certified
RP40-11024SFR (3,4) 43-160 24 1666 404 90
1300
UL60950-1 certified
RP40-2412DFR (3,4) 9-36 ±12 ±1666 1851 90
±2600
IEC/EN60950-1 certified
RP40-2415DFR (3,4) 9-36 ±15 ±1333 1851 90
±1600
EN55032 compliant
RP40-2424DFR (3,4)
9-36 ±24 ±833 1830 91
±650
EN55024 compliant
RP40-4812DFR (3,4) 18-75 ±12 ±1666 925 90
±2600
EN50121-3-2 compliant
RP40-4815DFR (3,4) 18-75 ±15 ±1333 741 90
±1600
RP40-4824DFR (3,4)
18-75 ±24 ±833 572 91
±650
RP40-11012DFR (3,4) 43-160 ±12 ±1666 408 89
±2600
RP40-11015DFR (3,4) 43-160 ±15 ±1333 408 89
±1600
RP40-11024DFR (3,4)
43-160 ±24 ±833 400 91
±650
PL
U
D
IA N
T PRO
REF
DESIGN
available
Model Numbering
RP40-__ __ _FR/_- _
nom. Input Voltage
nom. Output Voltage
“Package ”
(4)
“CTRL Logic (3)”
Single or Dual
Notes:
Note3: standard part is with suffix “P” for positive logic (1=ON, 0=OFF)
or add suffix “N” instead for negative logic (0=ON, 1=OFF)
Note4: add suffix “-HC” for premounted Heat-sink with clips
Ordering Examples
RP40-2405SFR/P = 24V input, 5V output, single, positive Logic CTRL pin
RP40-4812DFR/N-HC = 48V input, ±12V output, dual, negative Logic CTRL pin, Heat-sink premounted
www.recom-power.com
REV.: 8/2020
https://recom-power.com/
rec-s-R-REF04-RIA12.html
SURGE
PROTECTOR
available
https://recom-power.com/rec-sRSPxxx-168.html
PD-1
RP40-FR
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
nom. Vin = 24VDC
nom. Vin = 48VDC
nom. Vin = 110VDC
9VDC
18VDC
43VDC
24VDC
48VDC
110VDC
Max.
Internal Input Filter
Input Voltage Range
nom. Vin = 24VDC
nom. Vin = 48VDC
nom. Vin = 110VDC
DC-DC ON
DC-DC OFF
8VDC
nom. Vin = 48VDC
DC-DC ON
DC-DC OFF
16VDC
nom. Vin = 110VDC
DC-DC ON
DC-DC OFF
40VDC
Input Surge Voltage
1s max.
nom. Vin = 24VDC
Under Voltage Lockout (UVLO)
18VDC
43VDC
3.3Vout, 5Vout, 12Vout
15Vout, 24Vout
refer to
Output Voltage Trimming
„OUTPUT VOLTAGE TRIMMING“
-10%
-10%
+10%
+20%
Power up
ON/OFF CTRL
Start-up Time
60ms
60ms
Open or 3.0VDC < VCTRL< 12VDC
Short or 0VDC < VCTRL< 1.2VDC
Short or 0VDC < VCTRL< 1.2VDC
Open or 3.0VDC < VCTRL< 12VDC
Positive Logic
DC-DC ON
DC-DC OFF
Negative Logic
DC-DC ON
DC-DC OFF
Input Current of CTRL pin
drive current
ICTRL
Standby Current
DC-DC OFF
IIn
measured by 20MHz bandwidth
with a 1µF/50V X7R MLCC
3.3Vout, 5Vout
12Vout, 15Vout
24Vout
ON/OFF CTRL
refer to “ON/OFF CTRL”
(5)
-0.5mA
+0.5mA
3mA
Internal Operating Frequency
225kHz
Output Ripple and Noise
Pi-Type
36VDC
75VDC
160VDC
50VDC
100VDC
170VDC
9VDC
250kHz
75mVp-p
100mVp-p
150mVp-p
30mAp-p
Input Reflected Ripple Current
275kHz
100mVp-p
125mVp-p
200mVp-p
Notes:
Note5:
The ON/OFF control function can be positive or negative logic. The pin voltage is referenced to -Vin pin
RP40-2405SFR
Efficiency vs. Output Current
90
90
80
80
70
70
60
50
40
30
9Vin
24Vin
36Vin
20
10
0
10
20
30
40
50
60
70
80
Efficiency vs. Input Voltage
100
Efficiency [%]
Efficiency [%]
100
90
60
50
40
30
20
10
0
100
Output Current [%]
9
12
15
18
21
24
27
30
33
36
Input Voltage [VDC]
continued on next page
www.recom-power.com
REV.: 8/2020
PD-2
RP40-FR
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
RP40-4805SFR
Efficiency vs. Output Current
90
90
80
80
70
70
60
50
40
30
18Vin
48Vin
75Vin
20
10
0
10
20
30
40
50
60
70
80
Efficiency vs. Input Voltage
100
Efficiency [%]
Efficiency [%]
100
90
60
50
40
30
20
10
0
100
18
24
30
36
Output Current [%]
42
48
54
60
66
72
75
143
160
Input Voltage [VDC]
RP40-11005SFR
100
90
90
80
80
70
70
Efficiency [%]
Efficiency [%]
Efficiency vs. Output Current
100
60
50
40
30
43Vin
110Vin
160Vin
20
10
0
10
20
30
40
50
60
70
80
90
Efficiency vs. Input Voltage
60
50
40
30
20
10
0
100
43
52
62
Output Current [%]
72
84
96
110
125 136
Input Voltage [VDC]
OUTPUT VOLTAGE TRIMMING
Output Voltage Trimming
Single output Powerline converters offer the feature of trimming the output voltage over a certain range around the nominal value by using external
trim resistors. No general equation can be given for calculating the trim resistors, but the following trimtables give typical values for chosing these
trimming resistors. If voltages between the given trim points are required, extrapolate between the two nearest given values to work out the resistor
required or use a variable resistor to set the output voltage. Output can be externally trimmed by using the method shown below.
Trim up
Trim down
Trim
Trim
RD
RU
-Vout
+Vout
continued on next page
www.recom-power.com
REV.: 8/2020
PD-3
RP40-FR
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
RP40-xx3.3SFR
Trim up
1
2
3
4
5
6
7
8
9
10
[%]
Vout =
3.333
3.366
3.399
3.432
3.465
3.498
3.531
3.564
3.597
3.63
[VDC]
RU =
57.93
26.16
15.58
10.28
7.11
4.99
3.48
2.34
1.46
0.75
[kW]
1
2
3
4
5
6
7
8
9
10
[%]
Vout =
3.267
3.234
3.201
3.168
3.135
3.102
3.069
3.036
3.003
2.97
[VDC]
RD =
69.47
31.23
18.49
12.12
8.29
5.74
3.92
2.56
1.50
0.65
[kW]
2
3
4
5
6
7
8
9
10
[%]
Trim down
RP40-xx05SFR
Trim up
1
Vout =
5.05
5.10
5.15
5.20
5.25
5.30
5.35
5.4
5.45
5.50
[VDC]
RU =
36.57
16.58
9.92
6.89
4.59
3.25
2.30
1.59
1.03
0.59
[kW]
1
2
3
4
5
6
7
8
9
10
[%]
4.95
4.90
4.85
4.80
4.75
4.70
4.65
4.60
4.55
4.50
[VDC]
45.533
20.612
12.306
8.152
5.66
3.999
2.812
1.922
1.23
0.676
[kW]
2
3
4
5
6
7
8
9
10
[%]
Trim down
Vout =
RD =
RP40-xx12SFR
Trim up
1
Vout =
12.12
12.24
12.36
12.48
12.60
12.72
12.84
12.96
13.08
13.20
[VDC]
RU =
367.91
165.95
98.636
64.977
44.782
31.318
21.701
14.488
8.879
4.391
[kW]
1
2
3
4
5
6
7
8
9
10
[%]
Trim down
Vout =
11.88
11.76
11.64
11.52
11.40
11.28
11.16
11.04
10.92
10.8
[VDC]
RD =
460.99
207.95
123.6
81.423
56.118
39.249
27.199
18.162
11.132
5.509
[kW]
RP40-xx15SFR
Trim up
1
2
3
4
5
6
7
8
9
10
[%]
Vout =
15.15
15.3
15.45
15.60
15.75
15.90
16.05
16.20
16.35
16.50
[VDC]
RU =
419.81
199.91
126.60
89.95
67.96
53.30
42.83
34.98
28.87
23.98
[kW]
Trim up
11
12
13
14
15
16
17
18
19
20
[%]
Vout =
16.650
16.800
16.950
17.100
17.250
17.400
17.550
17.700
17.850
18.000
[VDC]
RU =
19.98
16.65
13.83
11.42
9.32
7.49
5.87
4.43
3.15
1.99
[kW]
1
2
3
4
5
6
7
8
9
10
[%]
Vout =
14.85
14.70
14.55
14.40
14.25
14.1
13.95
13.8
13.65
13.5
[VDC]
RD =
284.89
128.68
76.61
50.58
34.96
24.55
17.11
11.53
7.19
3.72
[kW]
2
3
4
5
6
7
8
9
10
[%]
Trim down
RP40-xx24SFR
Trim up
1
Vout =
24.240
24.480
24.720
24.960
25.200
25.440
25.680
25.920
26.160
26.400
[VDC]
RU =
1275.2
606.60
383.73
272.30
205.44
160.87
129.03
105.15
86.58
71.72
[kW]
Trim up
11
12
13
14
15
16
17
18
19
20
[%]
Vout =
26.640
26.880
27.120
27.360
27.600
27.840
28.080
28.320
28.560
28.800
[VDC]
RU =
59.56
49.43
40.86
33.51
27.15
21.57
16.66
12.29
8.38
4.86
[kW]
1
2
3
4
5
6
7
8
9
10
[%]
Trim down
Vout =
23.760
23.520
23.280
23.040
22.800
22.560
22.320
22.080
21.840
21.600
[VDC]
RD =
838.15
376.78
222.98
146.09
99.95
69.19
47.22
30.74
17.93
7.68
[kW]
www.recom-power.com
REV.: 8/2020
PD-4
RP40-FR
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
ON/OFF CTRL
IIN
+Vin
ICTRL
VCTRL
+Vin
+Vout
Positve Logic
DC-DC ON
DC-DC OFF
Open or 3.0VDC < VCTRL < 12VDC
Short or 0VDC < VCTRL < 1.2VDC
Negative Logic
DC-DC ON
DC-DC OFF
Short or 0VDC < VCTRL < 1.2VDC
Open or 3.0VDC < VCTRL < 12VDC
CTRL
-Vin
-Vin
+Vout
-Vout
-Vout
REGULATIONS
Parameter
Condition
Value
Output Accuracy
±1.0%
Line Regulation
low line to high line, full load
Load Regulation
0% to 100% load
Cross Regulation
±0.2%
Single
Dual
±0.5%
±1.0%
asymmetrical 25%100% load
Transient Response Recovery Time
±5.0%
25% load step change
250μs typ.
PROTECTIONS
Parameter
Condition
Value
Short Circuit Protection (SCP)
Over Voltage Protection (OVP)
Over Load Protection (OLP)
continuous, automatic recovery
3.9VDC
6.2VDC
15VDC
20VDC
30VDC
3.3Vout
5Vout
12Vout
15Vout
24Vout
zener diode clamp
% Iout rated
150% typ., Hiccup mode
Over Temperature Protection (OTP)
115°C typ.
nom. Vin = 24, 48VDC
I/P to O/P
I/P to O/P to Case
1.6kVDC/1min.
1.6kVDC/1min.
nom. Vin = 110VDC
I/P to O/P
I/P to O/P to Case
3kVDC/1min.
1.6kVDC/1min.
Isolation Voltage (6)
Isolation Resistance
Viso= 500VDC
Isolation Capacitance
1GΩ min.
1500pF max.
Notes:
Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note7: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type
www.recom-power.com
REV.: 8/2020
PD-5
RP40-FR
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
ENVIRONMENTAL
Parameter
Condition
Value
without derating
with derating
Operating Temperature Range
-40°C to +60°C
-40°C to +105°C
Maximum Case Temperature
+105°C
Temperature Coefficient
±0.02%/K max.
Thermal Impedance
@ natural convection 0.1m/s
Operating Humidity
without heat-sink
with heat-sink
10.8K/W
10.3K/W
non-condensing
5% - 95% RH
Environmental testing Part 2-1: Tests
Test A: Cold
Storage temperature -40°C, 16 hours
Operating temperature -40°C, 2 hours
according to EN60068-2-1:2007
Environmental testing Part 2-2: Tests
Test B: Dry heat
Temperature +85°C, 6 hours
according to EN60068-2-2:2007
Temperature: +25 to +55°C
Humidity: 90%+/-5% RH
Test Duration: 48 hours
Random vibration test 5Hz to 150Hz, Z-Axis
1.01m/s² (0.103Grms), Y-Axis, X-Axis 0.70m/s²
(0.0714Grms), Duration 10min/Axis
Environmental testing Part 2-30: Tests
Test Db: Damp heat, cyclic (12 h + 12 h cycle)
Railway applications – Rolling stock equipment –
Shock and vibration tests
according to EN60068-2-30:2005
according to EN61373:2010
Fire protection on railway vehicles
according to EN45545-2:2013
Fire hazard testing Part 2-11: Glowing/hot-wire
based test methods – Glow-wire flammability test
method for end-products
Fire hazard testing Part 11-10: Test flames – 50 W
horizontal and vertical flame test methods
Oxygen index test
according to EN ISO 4589-2 OI
Glow-wire test
according to EN60695-2-11
Shock
according to MIL-STD-810F
Thermal Shock
according to MIL-STD-810F
Vibration
according to MIL-STD-810F
MTBF
according to MIL-HDBK-217F, G.B
907.3 x 103 hours
Derating Graph (8)
(@ Chamber and natural convection 0.1m/s)
RP40-2415SFR-HC
100
100
80
80
Output Power [%]
Output Power [%]
RP40-2415SFR
60
40
20
0
-40
-20
0
20
40
60
60
40
20
0
-40
80 100 120
105
-20
0
20
40
60 80 100 120
105
65
Ambient Temperature [°C]
Ambient Temperature [°C]
Notes:
Note8: Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-number
not shown here please contact RECOM Techsupport for detailed information
www.recom-power.com
REV.: 8/2020
PD-6
RP40-FR
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Condition
Information Technology Equipment, General Requirements for Safety
E196683
Information Technology Equipment, General Requirements for Safety
(LVD)
TW1708011-001
Standard
UL60950-1, 2nd Edition, 2014
CAN/CSA-C22.2 No. 60950-1-07, 2nd Edition, 2014
IEC60950-1:2005, 2nd Edition + A2:2013
EN60950-1:2006 + A2:2013
Railway Applications - Electrical Equipment used on rolling stock
15A100702E-C
EN50155:2007
EAC
RU-AT.49.09571
TP TC 004/2011
RoHS2
RoHS-2011/65/EU + AM-2015/863
EMC Compliance (Railway)
Condition
“refer to EMC filtering”
Railway Applications - Electromagnetic Compatibility
Industrial, Scientific and Medical Equipment – Radio Frequency
Disturbance Characteristics – Limits and Methods of Measurement
Standard / Criterion
EN50121-3-2:2006
EN55011
ESD Electrostatic Discharge Immunity Test
Air ±2, ±4, ±8kV
Contact ±2, ±4, ±6kV
EN61000-4-2, Criteria A
Radiated, Radio-Frequency, Electromagnetic Field Immunity Test
20V/m (80-1000MHz)
EN61000-4-3, Criteria A
Fast Transient and Burst Immunity
(9)
Surge Immunity (9)
Immunity to Conducted Disturbances, Induced by Radio-Frequency Fields
EMC Compliance (Multimedia)
Electromagnetic Compatibility of Multimedia Equipment - Emission
Requirements
DC Power Port: ±2kV
EN61000-4-4, Criteria A
DC Power Port: L-L ±0.5, 1kV
DC Power Port: L-E ±0.5, 1, 2kV
EN61000-4-5, Criteria A
DC Power Port: 10V
EN61000-4-6, Criteria A
Condition
Standard / Criterion
with external filter
“refer to EMC filtering”
EN55032, Class A and B
Information Technology Equipment - Immunity Characteristics - Limits
and Methods of Measurement
EN55024:2010 + A1:2015
ESD Electrostatic Discharge Immunity Test
Air ±2, ±4, ±8kV
Contact ±2, ±4, ±6kV
IEC61000-4-2:2008, Criteria A
Radiated, Radio-Frequency, Electromagnetic Field Immunity Test
20V/m (80-1000MHz)
IEC61000-4-3:2006 + A2:2010, Criteria A
DC Power Port: ±2kV
IEC61000-4-4:2012, Criteria A
DC Power Port: ±0.5, ±1, ±2kV
IEC61000-4-5:2014, Criteria A
Fast Transient and Burst Immunity
Surge Immunity
Immunity to Conducted Disturbances, Induced by Radio-Frequency Fields
Power Magnetic Field Immunity
DC Power Port: 10V
IEC61000-4-6:2013, Criteria A
50Hz 100A/m, 1000A/m
IEC61000-4-8:2009, Criteria A
Notes:
Note9: An external input filter capacitor is required if the module has to meet EN61000-4-4 and -4-5.
The RP40-24xxFR requires an aluminum electrolytic capacitor (Nippon chemi-con KY series, 220μF/100V) and a TVS (SMDJ58A,
58V, 3000Watt peak pulse power) connected in parallel.
The RP40-48xxFR requires an aluminum electrolytic capacitor (Nippon chemi-con KY series, 220μF/100V) and a TVS
(SMDJ120A,120V, 3000Watt peak pulse power) connected in parallel.
The RP40-110xxFR requires 3pcs aluminum electrolytic capacitor in parallel (Ruby-con BXF series, 68μF/200V) and two TVS
(SMDJ90A, 90V, 3000Watt peak pulse power) in series, connected in parallel.
continued on next page
www.recom-power.com
REV.: 8/2020
PD-7
RP40-FR
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
EMC Filtering according to EN50121-3-2 (Single Outputs)
C7
L1
+VIN
C1(9)
C2
C4
C3
LOAD
TVS1(9)
TVS2(9)
-VIN
C6
C5
EMC Filtering according to EN50121-3-2 (Dual Outputs)
C7
L1
TVS1(9)
C1(9)
C2
C3
LOAD
+VIN
C4
LOAD
TVS2(9)
-VIN
C6
C5
Component List
MODEL
TVS1
TVS2
RP40-24xxS_DFR
SMDJ58A
58V, 3000W
peak pulse power
RP40-48xxS_DFR
SMDJ120A
120V, 3000W
peak pulse power
RP40-110xxS_DFR
SMDJ90A
SMDJ90A
90V, 3000W
90V, 3000W
peak pulse power peak pulse power
C1(9)
C2
C3
C4
10µF/50V
1210 MLCC
N/A
220µF/100V
N/A
N/A
4.7µF/100V
1210 MLCC
68µF/200V
3 in parallel
33µF/250V
1µF/250V
Al Cap. (lie down)
1812 MLCC
Chemi-con KXJ
C5, C6, C7
680pF/3kV
1808 MLCC
L1
2.2µH 11A
SMD-Inductor
12µH 4A
SMD-Inductor
1000pF
1µF/250V
22µH 1.5A
TDK CD series
1812 MLCC
SMD-Inductor
Y1
continued on next page
www.recom-power.com
REV.: 8/2020
PD-8
RP40-FR
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
EMC Filtering according to EN55032 Class A (Single Outputs)
C8
L1
Fuse
C1
C2
C3
C4
C5
LOAD
+VIN
-VIN
C7
C6
EMC Filtering according to EN55032 Class A (Dual Outputs)
C8
L1
Fuse
C2
C3
C4
C5
LOAD
C1
LOAD
+VIN
-VIN
C7
C6
Component List
MODEL
C1
RP40-24xxS_DFR
10µF/50V
1210 MLCC
RP40-48xxS_DFR
4.7µF/100V
1210 MLCC
RP40-110xxS_DFR
N/A
C2
N/A
C3
N/A
33µF/250V
Al Cap. (lie down)
Chemi-con KXJ
C4
C5
N/A
10µF/50V
1210 MLCC
4.7µF/100V
1210 MLCC
1µF/250V
1812 MLCC
C6
C7
680pF/3kV
1808 MLCC
1000pF
TDK CD series
Y1
C8
L1
2.2µH 11A
SMD Inductor
12µH 4A
SMD Inductor
22µH 1.5A
SMD Inductor
continued on next page
www.recom-power.com
REV.: 8/2020
PD-9
RP40-FR
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
EMC Filtering according to EN55032 Class B (24Vin and 48Vin, Single Outputs)
C5
L2
L1
Fuse
C1
C3
C2
LOAD
+VIN
-VIN
C7
C6
C4
EMC Filtering according to EN55032 Class B (24Vin and 48Vin, Dual Outputs)
C5
L2
L1
Fuse
C1
LOAD
+VIN
C3
LOAD
C2
-VIN
C7
C6
C4
Component List
MODEL
C1/C2
RP40-24xxS_DFR
10µF/50V
1210 MLCC
RP40-48xxS_DFR
4.7µF/100V
1210 MLCC
C3
C4/C6
82µF/100V
Al Cap. (lie down)
Chemi-con KJ
1000pf/3kV
1808 MLCC
C5/C7
2200pf/3kV
1808 MLCC
L1/L2
3.3µH 10A
SMD Inductor
12µH 4A
SMD Inductor
continued on next page
www.recom-power.com
REV.: 8/2020
PD-10
RP40-FR
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
EMC Filtering according to EN55032 Class B (110Vin Single Outputs)
C7
L2
L1
Fuse
C1
C2
C4
C3
C5
C6
LOAD
+VIN
-VIN
C9
C8
EMC Filtering according to EN55032 Class B (110Vin Dual Outputs)
C7
L2
L1
Fuse
C2
C4
C3
C5
C6
LOAD
C1
LOAD
+VIN
-VIN
C9
C8
Component List
MODEL
RP40-110xxS_DFR
C1
C2/C3
C4
C5/C6
C7/C8/C9
L1/L2
33µF/250V
Al Cap. (lie down)
Chemicon -KXJ
1µF/250V
1812 MLCC
33µF/250V
Al Cap. (lie down)
Chemicon -KXJ
1µF/250V
1812 MLCC
2200pF
TDK CD series Y1
22µH 1.5A
SMD Inductor
DIMENSIONS AND PHYSICAL CHARACTERISTICS
Parameter
Material
Dimensions (LxWxH)
Weight
Type
Value
case
base
potting
without Heat-sink
with Heat-sink
copper alloy (CuZn33)
FR4 PCB
silicone (UL94 V-0)
50.8 x 25.4 x 10.2mm
56.8 x 25.4 x 16.8mm
without Heat-sink
with Heat-sink
32g
43g
continued on next page
www.recom-power.com
REV.: 8/2020
PD-11
RP40-FR
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load unless otherwise stated)
Dimension Drawing (mm)
Pinning Information
18 x 2.54= 45.72
5.6
25.4
10.2
50.8
Pin #
1
2
3
4
5
6
2.5
Ø 1.0
7.62
5.1
15.24
6
3
2.54
2
Bottom View
2.54
2.54
5.08
4
Dual
+Vin
-Vin
CTRL (3)
+Vout
Com
-Vout
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.25mm
±0.1
Recommended Footprint Details
1
Single
+Vin
-Vin
CTRL (3)
+Vout
-Vout
Trim
Top View
5
2
5
1
3
4
2.54
6
Dimension Drawing with Heat-sink (mm)
50.8
10.2
16.8
18 x 2.54= 45.72
2.54
PACKAGING INFORMATION
15.24
2.54
Bottom View
5
Packaging Quantity
3
Storage Temperature Range
Storage Humidity
6
Type
tube
tray
3
tube
tray
2
1
Value
6
without heat-sink
with heat-sink
Top View
without heat-sink
with heat-sink
non-condensing
2.54
7.62
4
1
Packaging Dimension
2 (LxWxH)
Ø 1.0±0.1
2.54
5.08
5.08
Parameter
24.2
5.85
56.8
5.6
25.4
Top View
Heat-sink
5
4
255.0 x 54.0 x 22.0mm
302.5 x 222.0 x 20.0mm
9pcs
20pcs
-55°C to +125°C
5% - 95% RH
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 8/2020
PD-12