• 4:1 wide input range
• 3kVAC reinforced insulation for 110Vin
2.25kVDC basic insulation for 24Vin & 48Vin
• Efficiency up to 90%
• No minimum load required
• EN50155 certified
• IEC/EN60950-1 certified
Features
Regulated
Converter
Description
DC/DC Converter
RP90Q-RW
90 Watt
3
Quarter
Brick
Single Output
YEA R
y
arrant
w
The quarter brick RP90Q series DC/DC converters are designed for railway rolling stock and high voltage battery
applications. Each series has three 4:1 input voltage range options to cover all input voltages from 9VDC up to
160VDC with isolated and regulated 5V to 48VDC outputs. The converters have high efficiencies and metal baseplates to permit a wide operating temperature range from -40°C to +85°C (when mounted on a suitable heatsink).
The case is fitted with threaded inserts to allow secure mounting to the PCB or bulkhead for use in high shock and
vibration environments. The converters are EN50155 and IEC/EN60950 certified. The RP90Q-RW series have a
three year warranty.
T
CONVER
T
R
S
S
RE
M
E
R
C
TS
compliant
PL
U
D
IA N
T PRO
CO
10 from 10
O
REACH
compliant
M
C
M
TS
CONVER
C
M
PL
U
D
IA N
T PRO
EN50155 certified
IEC/EN60950-1 certified
Efficiency is tested by nominal Vin, full load and at 25°C
Model Numbering
REF
DESIGN
available
RP90Q-__ __ SRW/_ _
Input Voltage
Output Voltage
Package(3)
CTRL Logic(2)
https://recom-power.com/rec-s-RREF04-RIA12.html
Single
Notes:
Note2: standard part is with suffix “P” for positive logic (1=ON, 0=OFF)
or add suffix “N” instead for negative logic (0=ON, 1=OFF)
for more details refer to “ON/OFF CTRL (4)”
Note3: add suffix “-HC” for premounted Heat-sink (refer to “Dimension Drawing Heat-sink (mm)”)
(compatible with all other suffixes)
Ordering Examples
RP90Q-2405SRW/N = 24V Input, 5V Output, Single, Neg. CTRL function
RP90Q-11012SRW/P = 110V Input, 12V Output, Single, Pos. CTRL function
RP90Q-2405SRW/N-HC = 24V Input, 5V Output, Single, Neg. CTRL function, with premounted Heat-sink
www.recom-power.com
O
E
Notes:
Note1:
C
RoHS 2 +
CO
Part Number
Input
Output Output Input(1) Output Efficiency(1) Max. Capacitive
Voltage Range Voltage Current Current Power
typ.
Load
[VDC] [VDC] [mA] [mA] [W]
[%]
[µF]
RP90Q-2405SRW(2,3) 9-36
5 18000 4213 90
89
36000
RP90Q-2412SRW(2,3) 9-36
12 7500 4213 90
89
6250
RP90Q-2415SRW(2,3) 9-36
15 6000 4213 90
89
4000
RP90Q-2424SRW(2,3) 9-36
24 3700 4157 89
89
1540
RP90Q-2448SRW(2,3) 9-36
48 1800 4090 86.5
88
380
RP90Q-4805SRW(2,3) 16.5-75
5 18000 2107
90
89
36000
RP90Q-4812SRW(2,3) 16.5-75
12 7500 2107
90
89
6250
RP90Q-4815SRW(2,3) 16.5-75
15 6000 2083
90
90
4000
RP90Q-4824SRW(2,3) 16.5-75
24 3700 2055
89
90
1540
RP90Q-4848SRW(2,3) 16.5-75
48 1800 2000
86.5
90
380
RP90Q-11005SRW(2,3) 40-160
5
17000 868
85
89
34000
RP90Q-11012SRW(2,3) 40-160
12
7000
858
84
89
5830
RP90Q-11015SRW(2,3) 40-160
15
5500
843
82.5
89
3670
RP90Q-11024SRW(2,3) 40-160
24
3500
858
84
89
1460
RP90Q-11048SRW(2,3) 40-160
48
1800
882
86.5
89
380
RE
Selection Guide
REV.: 6/2020
SURGE
PROTECTOR
available
https://recom-power.com/rec-sRSPxxx-168.html
PB-1
RP90Q-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
nom Vin = 24V
nom Vin = 48V
nom Vin = 110V
Vin = 24V, 1s max.
Vin = 48V, 1s max.
Vin = 110V, 1s max.
9VDC
16.5VDC
40VDC
24VDC
48VDC
110VDC
Max.
Internal Input Filter
Vin = 24V
DC-DC ON
DC-DC OFF
7.3VDC
Pi-Type
36VDC
75VDC
160VDC
50VDC
100VDC
185VDC
9VDC
8.1VDC
Vin = 48V
DC-DC ON
DC-DC OFF
15.5VDC
18VDC
16.3VDC
Vin = 110V
DC-DC ON
DC-DC OFF
33VDC
43VDC
36VDC
Input Voltage Range
Input Surge Voltage
Under Voltage Lockout (UVLO)
25mA
15mA
8mA
Vin = 24V
Vin = 48V
Vin = 110V
refer to “Output Voltage Trimming”
Quiescent Current
Output Voltage Trimming
-20%
Minimum Load
+10%
0%
Start-up time
Power up, ON/OFF Control
Positive Logic
ON/OFF CTRL (4)
refer to “ON/OFF CTRL”
75ms
DC-DC ON
DC-DC OFF
Open or 3.0VDC < VCTRL < 12VDC
Short or 0VDC < VCTRL < 1.2VDC
Short or 0VDC < VCTRL < 1.2VDC
Open or 3.0VDC < VCTRL < 12VDC
Input Current of CTRL pin
drive current
DC-DC ON
DC-DC OFF
ICTRL
Standby Current
DC-DC-OFF
IIn
Negative Logic
-0.5mA
1mA
3mA
Internal Operating Frequency
270kHz
Measured by 20MHz BW
with a 22µF/25V X7R MLCC
with a 22µF/25V X7R MLCC
with a 4.7µF/50V X7R MLCC
with a 2.2µF/100V X7R MLCC
Output Ripple and Noise
100ms
300kHz
330kHz
75mVp-p
100mVp-p
200mVp-p
300mVp-p
5 Vout
12, 15Vout
24Vout
48Vout
% of set Vout (refer to “REMOTE SENSE”)
Remote Sense
10%
Notes:
Note4: If fitted, the ON/OFF control function can be positive or negative logic. The pin voltage is referenced to -Vin
RP90Q-2405SRW
Efficiency vs. Input Voltage
Efficiency vs. Output Current
100
90
90
80
80
70
Efficiency [%]
Efficiency [%]
100
60
50
40
30
10
0
10
20
30
40
50
60
70
Output Current [%]
www.recom-power.com
80
90
60
50
40
100% Load
50% Load
25% Load
30
9Vin
24Vin
36Vin
20
70
20
10
100
9
continued on next page
REV.: 6/2020
12
15
18
21
24
27
30
33
36
Input Voltage [V]
PB-2
RP90Q-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
RP90Q-2405SRW
Power Dissipation vs. Output Current
Typical Output Ripple and Noise/full load
Power Dissipation [W]
18
15
12
9
6
9Vin
24Vin
36Vin
3
0
10
20
30
40
50
60
70
80
90
100
Output Current [%]
ON/OFF Control Start up Rise Characteristic
Power up Start-up Rise Characteristic
RP90Q-4805SRW
Efficiency vs. Input Voltage
100
90
90
80
80
70
Efficiency [%]
Efficiency [%]
Efficiency vs. Output Current
100
60
50
40
16.5Vin
24Vin
48Vin
75Vin
30
20
10
0
10
20
30
40
50
60
70
80
90
70
60
50
40
100% Load
50% Load
25% Load
30
20
100
10
16.5
Output Current [%]
24
30
36
42
48
54
60
66
72
75
Input Voltage [V]
continued on next page
www.recom-power.com
REV.: 6/2020
PB-3
RP90Q-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
RP90Q-4805SRW
Power Dissipation vs. Output Current
Typical Output Ripple and Noise/full load
18
Power Dissipation [W]
15
12
9
6
16.5Vin
24Vin
48Vin
75Vin
3
0
10
20
30
40
50
60
70
80
90
100
Output Current [%]
ON/OFF Control Start up Rise Characteristic
Power up Start-up Rise Characteristic
RP90Q-11005SRW
Efficiency vs. Output Current
Efficiency vs. Input Voltage
95
90
85
80
75
70
65
60
55
50
45
40
Efficiency [%]
Efficiency [%]
100
40Vin
75Vin
110Vin
160Vin
10
20
30
40
50
60
70
80
90
100
100
95
90
85
80
75
70
65
60
55
50
45
40
100% Load
50% Load
25% Load
40
50
60
70
80
90 100 110 120 130 140 150 160
Input Voltage [V]
Output Current [%]
continued on next page
www.recom-power.com
REV.: 6/2020
PB-4
RP90Q-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
Power Dissipation [W]
RP90Q-11005SRW
Power Dissipation vs. Output Current
Typical Output Ripple and Noise/full load
12
11
10
9
8
7
6
5
4
3
2
43Vin
110Vin
160Vin
1
0
10
20
30
40
50
60
70
80
90
100
Output Current [%]
ON/OFF Control Start up Rise Characteristic
Power up Start-up Rise Characteristic
ON/OFF CTRL
+Vin
VCTRL
-Vin
IIN
ICTRL
+Vin
+Vout
+Vout
Positve Logic
DC-DC ON
DC-DC OFF
Open or 3.0VDC < VCTRL < 12VDC
Short or 0VDC < VCTRL < 1.2VDC
Negativ Logic
DC-DC ON
DC-DC OFF
Short or 0VDC < VCTRL < 1.2VDC
Open or 3.0VDC < VCTRL < 12VDC
CTRL
-Vin
-Vout
-Vout
REMOTE SENSE
+Vin
RW1
+Vout
The output voltage can be adjusted by both trim and remote sense. The
maximum combined adjustment range ±10%. Derate the maximum output power if using the trim or sense function.
+Sense
R1
Load
Trim
R2
-Sense
-Vin
www.recom-power.com
-Vout
(GND)
RW2
RW1 ... wire losses +
RW2 ... wire losses R1 ... trim up resistor
R2 ... trim down resistor
REV.: 6/2020
PB-5
RP90Q-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
OUTPUT VOLTAGE TRIMMING
Output Voltage Trimming
It allows the user to increase or decrease the output voltage of the module. This is accomplished by connecting an external resistor between the Trim pin and
either the +Sense or -Sense pins. With an external resistor between the Trim and +Sense pin, the output voltage increases. With an external resistor between
the Trim and -Sense pin, the output voltage decreases. The external Trim resistor needs to be at least 1/8W of rated. The values for trim resistors shown in trim
tables below are according to standard E96 values; therefore, the specified voltage may slightly vary.
Trim up
Trim down
Trim
-Sense
Rup
Rdown
+Sense
Trim
Voutnom = nominal output voltage [VDC]
Voutnom
DVout = output voltage change [%]
R2
R3
Vref
10k2Ω
511kΩ
5k11
1.225VDC
5VDC
Vref
= reference voltage
[VDC]
12VDC
Rup
= trim up resistor
[W]
15VDC
Rdown
= trim down resistor
[W]
24VDC
[W]
48VDC
R1 & R2 = internal resistors
R1
Calculation:
Rup =
R3 x Voutnom x (100 + DVout )
-
Vref x DVout
(R1 x DVout) + R2
R2
Rdown =
DVout
DVout
- R1
Practical Example RP90Q-xx05SRW +10% / -10%
Rup =
5k11 x 5 x (100 + 10)
1.225 x 10
-
(10k2 x 10) + 511k
10
Rdown =
= 168kW
Rup according to E96 ≈ 169kW
511k
10
- 10k2 = 40k9W
Rdown according to E96 ≈ 41k2W
RP90Q-xx05SRW
Trim up
1
2
3
4
5
6
7
8
9
10
[%]
Voutset =
5.05
5.10
5.15
5.20
5.25
5.30
5.35
5.4
5.45
5.50
[VDC]
Rup (E96) ≈
1M58
806k
536k
402k
324k
247k
237k
205k
187k
169k
[W]
[%]
RP90Q-xx12SRW
Trim up
1
2
3
4
5
6
7
8
9
10
Voutset =
12.12
12.24
12.36
12.48
12.60
12.72
12.84
12.96
13.08
13.20
[VDC]
Rup (E96) ≈
4M53
2M26
1M54
1M15
931k
787k
681k
604k
536k
487k
[W]
[%]
RP90Q-xx15SRW
Trim up
1
2
3
4
5
6
7
8
9
10
Voutset =
15.15
15.30
15.45
15.60
15.75
15.90
16.05
16.20
16.35
16.50
[VDC]
Rup (E96) ≈
5M76
2M94
1M96
1M50
1M21
1M02
866k
768k
698k
619k
[W]
RP90Q-xx24SRW
Trim up
1
2
3
4
5
6
7
8
9
10
Voutset =
24.24
24.48
24.72
24.96
25.20
25.44
25.68
25.92
26.16
26.40
[VDC]
[%]
Rup (E96) ≈
9M53
4M87
3M24
2M94
2M00
1M69
1M47
1M27
1M15
1M05
[W]
continued on next page
www.recom-power.com
REV.: 6/2020
PB-6
RP90Q-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
RP90Q-xx48SRW
Trim up
1
2
3
4
5
6
7
8
9
10
Voutset =
Rup (E96) ≈
[%]
48.48
48.96
49.44
49.92
50.40
50.88
51.36
51.84
52.32
52.80
[VDC]
19M6
9M945
6M65
5M11
4M12
3M48
3M01
2M61
2M37
2M15
[W]
Trim Down all Vout‘s
Trim down
Rdown (E96) ≈
Trim down
Rdown (E96) ≈
1
2
3
4
5
6
7
8
9
10
[%]
499k
243k
162k
118k
90k9
75k
63k4
53k6
46k4
41k2
[W]
11
12
13
14
15
16
17
18
19
20
[%]
36k5
32k4
28k7
26k1
23k7
21k5
19k6
18k2
16k5
15k4
[W]
REGULATIONS
Parameter
Condition
Value
Output Accuracy
±1.0%
Line Regulation
low line to high line at full load
±0.1%
5Vout
0% to 100% load
others
Load Regulation
Transient Response
0.2%
0.1%
25% load step change
250μs typ.
Transient Response to Dynamic Load Change from 100% to 75% to 100% of Full Load at nom.Vin
RP90Q-2405SRW
RP90Q-4805SRW
RP90Q-11005SRW
www.recom-power.com
REV.: 6/2020
PB-7
RP90Q-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
PROTECTIONS
Parameter
Condition
Value
Short Circuit Protection (SCP)
below 100mΩ
continuous, automatic recovery
Over Voltage Protection (OVP)
% of nom. Vout
115%-130%, Hiccup Mode
% Iout rated
110%-140%, Hiccup Mode
Over Load Protection (OLP)
Over Temperature Protection (OTP)
+110°C
110Vin
I/P to O/P
I/P or O/P to Baseplate
3kVAC/1minute
1.5kVAC/1minute
24Vin, 48Vin
I/P to O/P
I/P or O/P to Baseplate
2.25kVDC/1minute
2.25kVDC/1minute
Isolation Voltage
Isolation Resistance
500 VDC
1GΩ min.
Isolation Capacitance
1500pF max.
110Vin
24Vin, 48Vin
Isolation Grade
reinforced insulation
basic insulation
Notes:
Note5: Refer to local wiring regulations if input over-current protection is also required. Recommended fuse: T35A slow blow
ENVIRONMENTAL
Parameter
Condition
Operating Baseplate Temperature Range
Maximum Case Temperature
100°C
Temperature Coefficient
Thermal Impedance
Value
refer to derating graph
±0.02%/°C max.
vertical direction by natural convection (0.1m/s) without Heat-sink
vertical direction by natural convection (0.1m/s) with Heat-sink
Operating Humidity
9°C/W
7.5°C/W
5% - 95% RH
Pollution Degree
PD2
Shock
according to EN61373 standard
Thermal Shock
according to MIL-STD-810F standard
Vibration
according to EN61373 standard
Fire protection on railway vehicles
MTBF
according to EN45545-2, 2013 standard
according to MIL-HDBK-217F standard, 25°C
507.0 x 103 hours
Thermal Calculation
Rthcase-ambient = 9°C/W (vertical)
Tcase
=
Case Temperature
Rthcase-ambientHC = 7.5°C/W (vertical)
Tambient
=
Environment Temperature
Pdissipation
=
Internal losses
T -T
Rthcase-ambient = case ambient PIN
=
Input Power
Pdissipation
POUT
=
Output Power
h
=
Efficiency under given Operating Conditions
P
Pdissipation = PIN - POUT = OUTapp
P
R
=
Thermal
Impedance
OUTapp
thcase-ambient
h
Practical Example:
Take the RP90Q-2405SRW with 9V input Voltage and 50% load. What is the maximum ambient operating temperature? Use converter vertical in application without airflow.
Effmin = 89% @ Vnom
POUT = 90W
POUTapp = 90 x 0.5 = 45W
h = 91% (Efficiency vs. Load Graph)
45
Pdissipation =
- 45 = 4.45W
0.91
without Heat-sink
with Heat-sink
Tcasemax - Tamb
100-Tamb
T
100-Tamb
-T
Rth =
--> 9°C/W =
RthHC = casemax amb --> 7.5°C/W =
4.45W
Pdissipation
Pdissipation
4.45W
Tamb = 60°C TambHC = 66°C
continued on next page
www.recom-power.com
REV.: 6/2020
PB-8
RP90Q-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
Derating Graph(6)
(@ Chamber - tested with forced convection)
RP90Q-2405SRW-HC
100
100
80
80
Output Power [%]
Output Power [%]
RP90Q-2405SRW
60
40
0.5m/s
1m/s
1.5m/s
2m/s
2.5m/s
20
0
-40
-20
0
20
39
40
60
80
60
40
natural convection
0.5m/s
1m/s
1.5m/s
2m/s
2.5m/s
20
0
-40
100 120
Ambient Temperature [°C]
-20
80
80
Output Power [%]
Output Power [%]
100
60
40
0.5m/s
1m/s
1.5m/s
2m/s
2.5m/s
-20
0
37
40
60
80
0
-40
100 120
-20
80
Output Power [%]
Output Power [%]
80
60
0.5m/s
1m/s
1.5m/s
2m/s
2.5m/s
0
36
40
60
20
28
40
60
80
100 120
60
40
natural convection
0.5m/s
1m/s
1.5m/s
2m/s
2.5m/s
20
20
0
RP90Q-11005SRW-HC
100
-20
100 120
Ambient Temperature [°C]
100
0
-40
80
natural convection
0.5m/s
1m/s
1.5m/s
2m/s
2.5m/s
RP90Q-11005SRW
20
60
40
Ambient Temperature [°C]
40
40
60
20
20
30
RP90Q-4805SRW-HC
100
0
-40
20
Ambient Temperature [°C]
RP90Q-4805SRW
20
0
80
100 120
0
-40
-20
0
20
25
40
60
80
100 120
Ambient Temperature [°C]
Ambient Temperature [°C]
Notes:
Note6: Derating graphs are valid only for the shown part numbers. If you need detailed derating-information about a part-
number not shown here please contact our technical support service at techsupportAT@recom-power.com
www.recom-power.com
REV.: 6/2020
PB-9
RP90Q-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report / File Number
Information Technology Equipment - General Requirements for Safety
Standard
IEC60950-1, 2nd Edition, 2005
EN60950-1, 2006
IEC62368-1:2014, 2nd Edition
EN62368-1:2014 + A11:2017
TW1608086-001
Audio/Video, information and communication technology equipment - Part1: Safety
requirements
LVD1904047
Railway Applications - Electrical Equipment used on rolling stock
TW1608078-001
EN50155, 2007
EAC
RU-AT.49.09571
TP TC 004/2011
RoHS2+
RoHS 2011/65/EU
EMI Compliance
Condition
Information technology equipment - Radio disturbance characteristics - Limits and
methods of measurement
Standard / Criterion
EN55032, Class A and Class B
with external filter
Industrial, scientific and medical equipment - Radio frequency disturbance
characteristics - Limits and methods of measurement
EN55011, Class A and Class B
ESD Electrostatic discharge immunity test
Radiated, radio-frequency, electromagnetic field immunity test
Fast Transient and Burst Immunity(7)
Surge Immunity(7)
Immunity to conducted disturbances, induced by radio-frequency fields
Power Magnetic Field Immunity
EN61000-4-2, Criteria A
EN61000-4-3, Criteria A
EN61000-4-4, Criteria A
EN61000-4-5, Criteria A
EN61000-4-6, Criteria A
EN61000-4-8, Criteria A
Air ±8kV and Contact ±6kV
20 V/m
±2kV
±2kV
10 Vr.m.s
100A/m continuous; 1000A/m 1s
Notes:
Note7: An external input filter capacitor is required if the module has to meet EN61000-4-4 and EN61000-4-5.
The 24Vin and 48Vin version recommend 2pcs of aluminium elecrolytic capacitor to connect in parallel.
Recom suggest: Nippon Chemi-con KY series, 220µF/100V.
RP90Q-24xxSRW, Class A
RP90Q-48xxSRW, Class A
The 110Vin version recommend 2pcs of aluminium electrolytic capacitor to connect in parallel.
Recom suggest: Nippon Chemi-con KXJ series, 150µF/200V
EMI Filtering according to EN55032/11 Class A and EN50121-1 (24Vin and 48Vin)
C9
L1
Fuse
C1
C2
C3
C4
C5
C6
C7
C8
LOAD
+VIN
Case
-VIN
C11
C10
C12
C13
C14
Shield Plane
C1
C2, C3, C4
C5
C6, C7, C8
C9 to C14
L1
RP90Q-24xxSRW
N/A
6.8µF, 50V
1812 MLCC
N/A
6.8µF, 50V
1812 MLCC
1000pF, 3kV
1808 MLCC
0.68µH, 17A
SMD Inductor
RP90Q-48xxSRW
4.7µF, 100V
1812 MLCC
4.7µF, 100V
1812 MLCC
4.7µF, 100V
1812 MLCC
4.7µF, 100V
1812 MLCC
1000pF, 3kV
1808
MLCC
C3
3.3µH, 10A
SMD Inductor
www.recom-power.com
+VIN
continued
on next page
L1
Fuse
REV.: 6/2020
C1
PB-10
C2
Case
LOAD
RP90Q-110xxSRW, Class A
MODEL
RP90Q-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
RP90Q-2405SRW
Conducted Emission EN55032 Class A
SRW, Class A
SRW, Class A
C9
L1
Fuse
RP90Q-4805SRW
C1
C2
C3
Conducted Emission EN55032 Class A
C4
C5
C6
C7
C8
LOAD
+VIN
Case
-VIN
C11
C10
C12
C13
C14
Shield Plane
xSRW, Class A
EMI Filtering according to EN55032/11 Class A and EN50121-1 (110Vin)
C3
L1
C1
C2
LOAD
Fuse
+VIN
Case
-VIN
C5
C6
C7
C4
C8
Shield Plane
MODEL
xxSRW, Class B
RP90Q-110xxSRW
C1, C2
C3 to C8
L1
39µF, 250V
Al cap. (lie down) Rubycon BXF
1000pF, 3kV
1808 MLCC
30.1µH, 5A
SMD Inductor
continued on next page
www.recom-power.com
+VIN
Fuse
L1
L2
REV.: 6/2020
C8
PB-11
8xxSRW, Class B
RP90Q-RW
DC/DC Converter
L1
L2
(measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
RP90Q-11005SRW
C2
C3
C4
C5
Conducted Emission
EN55032 Class A
C7
C6
LOAD
Specifications
Fuse
+VIN
C1
Series
C8
Case
-VIN
C10
C9
C11
C12
C13
C13
C14
C8
C9
Shield Plane
4xxSRW, Class B
EMI Filtering according to EN55032/11 Class B (24Vin)
L1
Fuse
C1
C2
C3
C4
C5
C6
C7
C8
LOAD
+VIN
C9
Case
-VIN
C11
C10
C12
Shield Plane
MODEL
RP90Q-24xxSRW
110xxSRW, Class B
C9, C10, C13, C14
C11, C12
L1
10µF, 50V
1812 MLCC
1000pF, 3kV
1808 MLCC
2200pF, 3kV
1812 MLCC
285µH
CMC
C4
L1
Fuse
C1
ConductedL2
Emission EN55032 Class B
C2
C3
LOAD
RP90Q-2405SRW
+VIN
C1 to C8
Case
-VIN
C6
C7
C5
Shield Plane
continued on next page
www.recom-power.com
REV.: 6/2020
PB-12
RW, Class B
RP90Q-RW
Shield Plane
C8
L1
DC/DC Converter
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
C2
C3
C4
C5
C7
C6
-VIN
L1
Fuse
+VIN
C1
C2
C8
Case
EMI Filtering according to EN55032/11 Class B (48Vin)
L2
C3
C4
C10
C5
C6
C11
C9
C7
C12
C13
LOAD
C1
LOAD
+VIN
Series
L2
Q-48xxSRW, Class
Fuse B
Case
-VIN
Shield Plane
C10
C9
C11
C12
C13
RW, Class B
Shield Plane
RP90Q-48xxSRW
L1
Q-24xxSRW, Class B Fuse
+VIN
RP90Q-4805SRW
C1
C2
C3
C1 to C7
C8 to C13
L1
4.7µF, 100V
1812 MLCC
1000pF, 3kV
1808 MLCC
620µH
CMC
C5Conducted
C6
C7Emission
C8
C4
L2
C9
285µH
CMC
EN55032 Class B
C9
Case
+VIN
L1
Fuse
C1
C2
C3
C4
C5
C6
C11
C7
C12
C10
C8
C13
C14
LOAD
-VIN
LOAD
MODEL
Case
-VIN
Shield Plane
C11
C10
C12
SRW, Class B
C13
C14
Shield Plane
EMI Filtering according to EN55032/11 Class B (110Vin)
+VIN
L1
Fuse
C4
L2
0Q-110xxSRW, Class B
C2
C3
C4
Case
L1
Fuse
+VIN
C1
L2
C6
C2
C7
C5
C3
C8
C9
LOAD
-VIN
LOAD
C1
Case
-VIN
Shield Plane
MODEL
C1, C2, C3
C6
C4
RP90Q-110xxSRW
39µF, 250V
Al cap. (lie down) Rubycon BXF
to C7
C9
1000pF, 3kV
1808 MLCC
continued on next page
www.recom-power.com
REV.: 6/2020
L1
735µH
CMC
C5
L2
C8
C9
30.1µH, 5A
SMD Inductor
Shield Plane
PB-13
RP90Q-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
RP90Q-110xxSRW
Conducted Emission EN55032 Class B
DIMENSIONS and PHYSICAL CHARACTERISTICS
Parameter
Material
Type
Value
Case
Plastic
Baseplate
Aluminium
Potting
Silicone (UL94 V-0)
Dimension (LxWxH)
without Heat-sink
with Heat-sink
57.9 x 36.6 x 12.7mm
57.9 x 36.6 x 18.8mm
Weight
without Heat-sink
with Heat-sink
64g
88g
Dimension Drawing Heat-sink (mm)
36.8
FC 26.5
57.9
FC 47.24
5.10
18.8
6.1
4xM3
Notes:
Note8: Max. tightening torque for Heat-sink: 0.34Nm
Ø1.0±0.25
Ø2.0±0.25
M3
continued on next page
www.recom-power.com
REV.: 6/2020
PB-14
RP90Q-RW
DC/DC Converter
Series
Specifications (measured @Ta = 25°C, resistive load, nominal Vin and rated Iout unless otherwise noted)
Dimension Drawing (mm)
57.9
18.4
Pin Connections
Pin #
+Vin
2
CTRL
3
-Vin
4
-Vout
5
-Sense
6
Trim
7
+Sense
8
+Vout
2xM3
FC 47.24
3.81
2
Top View
3
2.54
1
8
7
6
5
4
1
FC 26.5
Bottom View
2
4
5
6
7
8
11.43
10.8
FC 50.80
3
15.24
Single
1
FC= Fixing Centers for Heat-sink
Pin Pitch Tolerance ±0.25mm
Pin Dimension Tolerance ±0.1mm
XX.X ± 0.5mm
XX.XX ± 0.25mm
M3
Ø2.0±0.10
Ø1.0±0.10
7.62
5.10
12.7
36.8
tc
28.9
3.5
2.54
PACKAGING INFORMATION
Parameter
Packaging Dimension
Type
tray
Value
without Heat-sink
with Heat-sink
Packaging Quantity
157.0 x 88.0 x 23.0mm
157.0 x 88.0 x 35.0mm
2pcs
Storage Temperature Range
-55°C to +125°C
Storage Humidity
5% - 95% RH
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 6/2020
PB-15