Features Regulated Converters ● ● ● ● ● ● ● 2:1 and 3:1 Wide Input Voltage Ranges 1kVDC, 2kVDC and3kVDC Isolation UL94V-0 Package Material Continuous Short Circuit Protection Low Ripple and Noise Remote On/Off Control Efficiency to 83 % ECONOLINE DC/DC-Converter Description Very high power density, 2:1 or 3:1 input voltage range and a wide operating temperature range -40°C~+71°C and extra features such as On/Off control are just some of the characteristics of this converter which is ideal for highly sophisticated industrial designs.The RS3 is available with 2kV or 3kV isolation options (1kVDC is standard) Selection Guide Part Number SIP8 RS3-xx3.3S (H2/H3) RS3-xx05S RS3-xx09S RS3-xx12S RS3-xx15S (H2/H3) (H2/H3) (H2/H3) (H2/H3) Input Rated Output Output Current Voltage Range Voltage Full Load (VDC) (VDC) (mA) 4.5-9, 9-18 3.3 600 18-36, 36-72 4.5-9, 9-18 5 600 18-36, 36-72 4.5-9, 9-18 9 333 18-36, 36-72 4.5-9, 9-18 12 250 18-36, 36-72 4.5-9, 9-18 15 200 18-36, 36-72 4.5-9, 9-18 ±3.3 ±300 18-36, 36-72 4.5-9, 9-18 ±5 ±300 18-36, 36-72 4.5-9, 9-18 ±9 ±167 18-36, 36-72 4.5-9, 9-18 ±12 ±125 18-36, 36-72 4.5-9, 9-18 ±15 ±100 18-36, 36-72 9-27 3.3 600 20-60 9-27 5 600 20-60 9-27 9 333 20-60 9-27 12 250 20-60 9-27 15 200 20-60 9-27 ±3.3 ±300 20-60 9-27 ±5 ±300 20-60 9-27 ±9 ±167 20-60 9-27 ±12 ±125 20-60 9-27 ±15 ±100 20-60 Efficiency typ. (%) 73-75 77-78 76-79 80-81 77-80 81-82 80-81 83 80-81 83 73-75 75 76-80 80-81 77-81 81 78-83 83 79-83 83 73 74 76-79 78 77 79 80 80 80 80 73 74 77 78 79 79 80 80 80 80 Capacitive Load max. 1000µF 1000µF 470µF 220µF 100µF ±470µF ±470µF ±220µF ±100µF ±47µF 1000µF 1000µF 470µF 220µF 100µF ±470µF ±470µF ±220µF ±100µF ±47µF 3 Watt SIP8 Isolated Single & Dual Output 2002/95/EC 6/6 RoHS RS3-xx3.3D (H2/H3) RS3-xx05D RS3-xx09D RS3-xx12D RS3-xx15D (H2/H3) (H2/H3) (H2/H3) (H2/H3) EN-60950-1 Certified EN-60601-1 Certified ( Suffix /H2 or /H3) RS3 RS3-xx3.3SZ (H2/H3) RS3-xx05SZ (H2/H3) RS3-xx09SZ (H2/H3) RS3-xx12SZ (H2/H3) RS3-xx15SZ (H2/H3) RS3-xx3.3DZ (H2/H3) RS3-xx05DZ (H2/H3) RS3-xx09DZ (H2/H3) RS3-xx12DZ (H2/H3) RS3-xx15DZ (H2/H3) 2:1 Input (RS3-S/D) xx = 4.5-9Vin = 05 xx = 9-18Vin = 12 xx = 18-36Vin = 24 xx = 36-72Vin = 48 3:1 Input (RS3-SZ/DZ) xx = 9-27Vin = 24 xx = 20-60Vin = 48 Refer to Application Notes E-89 www.recom-international.com REV:0/2010 ECONOLINE DC/DC-Converter RS3-S_D/(Z) Series 2:1 and 3:1 Nominal Vin and full load LL to HL, full load 20% to 100% full load 20MHz limited 20% to 100% full load RS-05xxS_D RS-12xxS_D RS-24xxS_D, SZ_DZ RS-48xxS_D, SZ_DZ (tested for 1 second) H2 H3 (long term isolation) H1 H2/H3 ±2% typ. ±0.5% max. ±0.5% typ. 50mVp-p max. 200kHz typ. see Selection Guide 35mA typ. 25mA typ. 20mA typ. 10mA typ. 1000VDC min. 2000VDC min. 3000VDC min. see Application Notes 200pF max. 30pF max. 1GΩ min. Continuous –40°C to +71°C –55°C to +125°C 95% RH 4.7g 22 pcs per Tube using MIL-HDBK 217F using MIL-HDBK 217F 3303 x10³ hours 745 x10³ hours 100 80 Electrical Specifications (measured at TA = 25°C, at nominal input voltage and rated output current unless otherwise specified) Input Voltage Range Output Accuracy Line Voltage Regulation Load Voltage Regulation Output Ripple and Noise Switching Frequency Efficiency at Full Load Quiescent Current Nominal input Voltage (Standard, /H2 and /H3) Isolation Voltage (2:1 and 3:1) Derating-Graph (Ambient Temperature) RS3-(Z)S_D Output Power (%) 60 40 30 20 0 Safe Operating Area Rated Working Voltage Isolation Capacitance (2:1 and 3:1) (tested at 100kHz) Isolation Resistance Short Circuit Protection Operating Temperature Range Storage Temperature Range Relative Humidity Package Weight Packing Quantity MTBF (+25°C) (+71°C) 71 Operating Temperature °C -40 0 50 85 150 RS3 } Detailed Information see Application Notes chapter "MTBF" Typical Characteristics RS3-xxxxS 80 4805S 2405S 1205S 0505S 80 4805D 2405D 1205D 0505D RS3-xxxxD 75 75 Efficiency (%) Efficiency (%) 400 70 100 200 300 500 600 70 ±50 ±100 ±150 ±200 ±250 ±300 Output Current ( mA ) Efficiency Vs Load ( Nominal Vin ) Output Current ( mA ) Efficiency Vs Load ( Nominal Vin ) E-90 REV: 0/2010 www.recom-electronic.com ECONOLINE DC/DC-Converter Package Style and Pinning (mm) RS3-S_D(Z) Series 3rd angle projection 9.20 Single Output Dual Output 11.10 4.1 typ. RECOM RS3-xxxx **** 0.50±0.05 RECOM RS3-xxxxS(Z) **** 123 5678 RECOM RS3-xxxxD(Z) **** 123 5678 0.50±0.05 Recommended Footprint Details 1.0ø+0.15/–0 Pin Connections Pin # 1 2 3 5 6 Single –Vin +Vin CTRL NC +Vout –Vout NC Dual –Vin +Vin CTRL NC +Vout Com –Vout 21.80 0.32 Bottom View 2.54 3.20 2.0 2.54 Top View 7 8 Notes Pin 8 (NC*) This pin is used internally and must have no external connection. Pin 5 (NC) Not connected internally.. NC = No Connection XX.X ± 0.5 mm XX.XX ± 0.25 mm Pin 3 (CTRL) This pin provides an Off function which puts the converter into a low power mode. When the pin is ‘high’ the converter is OFF and when the pin is high ‘Z’ the converter is ON. There is no allowed low state for this pin. RS3 Application Examples TTL Remote CTRL Circuit Control Pin Input Current: 10mA +Vin 10 KW (see text) Ctrl (TTL) -Vin 4.7 KW 20 KW -Vout RSO/RS/RS3 +Vout Voltage Set Point Accuracy with external input/output capacitors refer to typ. ± 1% recommended test circuit: max. ±2% Control Pin (CTRL) Input Current, control voltage applied via 1K resistor, output voltage must reduce to 0V: typ. 3mA max. 6mA Voltage to be applied via a limiting resistor with a recommended value of 1K for RS3-05xx; 3.3K for RS3-12xx; RS3-24xx and 10K for RS3-48xx. Isolated Remote CTRL Circuit +Vin Remote Optocoupler -Vin (see text) -Vout +Vout RSO/RS/RS3 www.recom-international.com REV:0/2010 E-91
RS3-xx05S
### 物料型号 - RS3-xx3.3S(H2/H3) - RS3-xx05S(H2/H3) - RS3-xx09S(H2/H3) - RS3-xx12S(H2/H3) - RS3-xx3.3D(H2/H3) - RS3-xx05D(H2/H3) - RS3-xx09D(H2/H3) - RS3-xx12D(H2/H3) - RS3-xx15D(H2/H3) - RS3-xx3.3SZ(H2/H3) - RS3-xx05SZ(H2/H3) - RS3-xx09SZ(H2/H3) - RS3-xx12SZ(H2/H3) - RS3-xx15SZ(H2/H3) - RS3-xx3.3DZ(H2/H3) - RS3-xx05DZ(H2/H3) - RS3-xx09DZ(H2/H3) - RS3-xx12DZ(H2/H3) - RS3-xx15DZ(H2/H3)

### 器件简介 RECOM品牌的3瓦SIP8隔离单双输出DC/DC转换器,具有高功率密度、2:1或3:1的输入电压范围和宽工作温度范围(-40°C~+71°C)。这些转换器适用于高度复杂的工业设计,具有开/关控制等功能。

### 引脚分配 - 1号引脚:-Vin(负电压输入) - 2号引脚:+Vin(正电压输入) - 3号引脚:CTRL(控制引脚,用于开启和关闭转换器) - 5号引脚:NC(无连接) - 6号引脚:+Vout(正输出电压) - 7号引脚:-Vout(负输出电压,双输出时为公共地) - 8号引脚:NC(无连接)

### 参数特性 - 输入电压范围:4.5-9VDC、9-18VDC、18-36VDC、36-72VDC和9-27VDC、20-60VDC - 输出电压:3.3V、5V、9V、12V、15V和±3.3V、±5V、±9V、±12V、±15V - 额定输出电流:从250mA到600mA不等 - 效率:典型值从73%到83% - 电容负载:最大1000μF

### 功能详解 - 具有远程开/关控制功能,控制引脚高电平时关闭,低电平时开启。 - 具有连续短路保护功能。 - 工作效率可达83%,低纹波和噪声。

### 应用信息 适用于需要隔离和高功率密度转换的应用,如工业设计、医疗设备等。