Features
Regulated
Converters
•
•
•
•
•
•
•
2:1 wide input range
3kVDC/1 minute isolation
-40°C to +70°C (full load) operating range
IEC/EN62368-1 2nd & 3rd Ed. certified
UL/CSA/CAN 62368-1 certified
Industry standard pinout (SIP8)
Low cost
DC/DC Converter
RS3E
Description
The RS3E series offers very high power density, wide input voltage range, high 3kVDC isolation, and
an industrial operating temperature range of -40°C to +70°C without derating. High efficiency, tight
regulation, and remote on/off control are just some of the characteristics of this advanced, low cost,
SIP8, 3W converter which is ideal for highly sophisticated high density power supply designs in
demanding industrial applications.
3 Watt
3
SIP8
Single Output
max. Capacitive
Load (2)
[µF]
2200
50
5
600
75
2200
RS3E-0509S/H3
4.5-9
50
9
333
77
1000
RS3E-0512S/H3
4.5-9
70
12
250
78
1000
1000
1000
RS3E-123.3S/H3
20
3.3
5
600
600
74
77
RS3E-1209S/H3
9-18
20
9
333
79
1000
RS3E-1212S/H3
9-18
30
12
250
80
1000
RS3E-1215S/H3
9-18
30
15
200
80
1000
RS3E-1224S/H3
9-18
30
24
125
80
1000
RS3E-243.3S/H3
18-36
12
3.3
600
75
2200
RS3E-2405S/H3
18-36
12
5
600
79
2200
RS3E-2409S/H3
18-36
12
9
333
80
1000
RS3E-2412S/H3
18-36
12
12
250
81
1000
RS3E-2415S/H3
18-36
12
15
200
81
1000
RS3E-2424S/H3
18-36
12
24
125
81
1000
RS3E-483.3S/H3
36-72
10
3.3
600
75
2200
RS3E-4805S/H3
36-72
10
5
600
80
2200
RS3E-4809S/H3
36-72
10
9
333
80
1000
RS3E-4812S/H3
36-72
10
12
250
81
1000
RS3E-4815S/H3
36-72
10
15
200
81
1000
RS3E-4824S/H3
36-72
10
24
125
81
1000
C O N V ER
T
RoHS 2 +
compliant
2200
2200
M
M
10 from 10
PL
D
IA N
T PRO
U
C
O
M
CO NVE R
T
REACH
compliant
CO
9-18
20
O
CO
RS3E-1205S/H3
9-18
C
S
78
80
R
200
125
E
15
24
S
70
70
R
4.5-9
4.5-9
E
RS3E-0515S/H3
RS3E-0524S/H3
M
TS
Efficiency
typ. (1)
[%]
74
P
C
Output
Current
[mA]
600
RE
4.5-9
Output
Voltage
[VDC]
3.3
TS
RS3E-0505S/H3
Input Current
@ no load
[mA]
50
C
Input
Voltage Range
[VDC]
RS3E-053.3S/H3
4.5-9
RE
Selection Guide
Part
Number
U
LIA
D
N T PRO
E224736
UL62368-1 certified
CSA/CAN-C22.2 No. 62368-1 certified
IEC/EN62368-1 3rd Ed. certified
IEC/EN62368-1 2nd Ed. certified
EN55032 compliant
EN55035 compliant
CB Report
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Max Cap Load is tested at minimum input and constant resistive load
Model Numbering
RS3Enom. Output Power
Input Voltage
S/H3
Isolation
Single
Output Voltage
www.recom-power.com
REV.: 0/2021
ECO-1
RS3E
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Max.
Internal Input Filter
capacitor
Input Voltage Range
5VDC
12VDC
nom. Vin=
24VDC
48VDC
Input Surge Voltage
5VDC
12VDC
nom. Vin=
24VDC
48VDC
100ms
15VDC
25VDC
50VDC
100VDC
Minimum Load
0%
ON/OFF CTRL
DC-DC ON
DC-DC OFF
Start-up Time
power up & CTRL ON
open or high impedance
short to -VIN or 5VDC < VCTRL < 6VDC
10ms
130kHz
Internal Operating Frequency
Output Ripple and Noise (3)
20MHz BW
(@ nominal VIN)
RS3E-0505S
RS3E-123.3S
100
100
90
90
80
80
70
70
Efficiency [%]
Efficiency [%]
75mVp-p
Notes:
Note3: Measurements are made with a 0.1µF MLCC across output (low ESR)
Efficiency vs. Load
60
50
40
60
50
40
30
30
20
20
10
10
0
0
10
20
30
40
50
60
70
80
90
0
100
0
10
20
30
Output Load [%]
90
90
80
80
70
70
60
50
40
20
10
10
40
50
60
70
80
90
0
100
Output Load [%]
www.recom-power.com
80
90
100
70
80
90
100
40
20
30
70
50
30
20
60
60
30
10
50
RS3E-483.3S
100
Efficiency [%]
Efficiency [%]
RS3E-2405S
0
40
Output Load [%]
100
0
9VDC
18VDC
36VDC
72VDC
5VDC
12VDC
24VDC
48VDC
4.5VDC
9VDC
18VDC
36VDC
0
10
20
30
40
50
60
Output Load [%]
REV.: 0/2021
ECO-2
RS3E
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
ON/OFF CTRL
+Vin
+Vin
68 Ω
VCTRL
1N4148
+Vout
DC-DC ON
DC-DC OFF
CTRL
-Vin
-Vin
+Vout
-Vout
Open
Short to -VIN or 5VDC < VCTRL < 6VDC
-Vout
REGULATIONS
Parameter
Condition
Value
3.3Vout
others
Output Accuracy
±3.0% max.
±2.0% max.
Line Regulation
low line to high line, full load
24Vout
others
±1.0% max.
±0.4% max.
Load Regulation
0% to 100% load
24Vout
others
0.8% typ.
0.6% typ.
Deviation vs Load
(@ nominal VIN)
RS3E-0505S
RS3E-123.3S
2
1.5
Deviation [%]
Deviation [%]
1
0.5
0
-0.5
-1
-1.5
-2
0
10
20
30
40
50
60
70
80
90
100
3
2.5
2
1.5
1
0.5
0
-0.5
-1
-1.5
-2
-2.5
-3
0
10
20
30
Output Load [%]
RS3E-2405S
Deviation [%]
Deviation [%]
1
0.5
0
-0.5
-1
-1.5
10
20
30
40
50
60
70
80
90
100
Output Load [%]
www.recom-power.com
60
70
80
90
100
70
80
90
100
RS3E-483.3S
1.5
0
50
Output Load [%]
2
-2
40
3
2.5
2
1.5
1
0.5
0
-0.5
-1
-1.5
-2
-2.5
-3
0
10
20
30
40
50
60
Output Load [%]
REV.: 0/2021
ECO-3
RS3E
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
PROTECTIONS
Parameter
Type
Value
Short Circuit Protection (SCP)
continuous, auto recovery
I/P to O/P
Isolation Voltage (4)
Isolation Resistance
tested for 1 minute
3kVDC
1GΩ min.
Isolation Capacitance
250pF max.
Insulation Grade
functional
Notes:
Note4: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note5: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type
ENVIRONMENTAL
Parameter
Condition
Operating Temperature Range
@ natural convection 0.1m/s
Value
full load refer to “Derating Graph”
Temperature Coefficient
-40°C to +70°C
±0.05%/K
Operating Altitude
according to 62368-1
Operating Humidity
non-condensing
5000m
5% - 95% RH max.
Pollution Degree
PD3
Vibration
according to MIL-STD-202G
MTBF
according to MIL-HDBK-217F, G.B.
+25°C
1800 x 103 hours
Derating Graph
(@ Chamber and natural convection 0.1m/s)
100
90
Output Load [%]
80
70
60
50
40
30
20
10
0
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110
Ambient Temperature [°C]
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report Number
Audio/Video, information and communication technology equipment - Part 1: Safety requirements
Audio/Video, information and communication technology equipment - Part 1: Safety requirements
(CB Scheme)
E224736-A6018-UL
Standard
UL62368-1:2014
CAN/CSA-C22.2 No. 62368-1:2014
IEC62368-1:2018 3rd Edition
2003048-4-CB
Audio/Video, information and communication technology equipment - Part 1: Safety requirements
EN IEC62368-1:2020 + A11:2020
Audio/Video, information and communication technology equipment - Part 1: Safety requirements
(CB Scheme)
IEC62368-1:2014 2nd Edition
Audio/Video, information and communication technology equipment - Part 1: Safety requirements
RoHS2
2003048-3-CB
EN62368-1:2014 + A11:2017
RoHS 2011/65/EU + AM2015/863
continued on next page
www.recom-power.com
REV.: 0/2021
ECO-4
RS3E
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
EMC Compliance
Condition
Standard
Electromagnetic compatibility of multimedia equipment – Emission Requirements
EN55032:2015, Class B
Electromagnetic compatibility of multimedia equipment – Immunity requirements
EN55035:2017
Air: ±2, 4, 8kV
Contact: ±2, 4kV
3V/m, 10V/m (80-1000MHz, 800MHz,
900MHz, 1800MHz, 2600MHz,
3500MHz, 5000MHz)
ESD Electrostatic discharge immunity test
Radiated, radio-frequency, electromagnetic field immunity test
Fast Transient and Burst Immunity
IEC61000-4-2:2008, Criteria A
EN61000-4-2:2009, Criteria A
IEC/EN61000-4-3:2006+A2:2010,
Criteria A
DC Power Port: ±0.5, 2kV
IEC/EN61000-4-4:2012, Criteria A
Surge Immunity
DC Power Port: ±0.5
IEC/EN61000-4-5:2014, Criteria A
Immunity to conducted disturbances, induced by radio-frequency fields
3Vrms (0.15-10MHz)
3-1Vrms (10-30MHz)
1Vrms (30-80MHz)
10Vrms (0.15-80MHz)
IEC/EN61000-4-6:2013, Criteria A
Power Magnetic Field Immunity
1A/m, 10A/m
Limitations on the amount of electromagnetic interference allowed from digital
and electronic devices
IEC61000-4-8:2009
EN61000-4-8:2010
FCC 47 CFR Part 15 Subpart B,
Class B
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter
Type
Value
Material
case
potting
non-conductive black plastic, UL94 V-0
epoxy, UL94 V-0
Dimension (LxWxH)
21.8 x 9.2 x 11.1mm
Weight
4.7g typ.
Dimension Drawing (mm)
embossed logo
21.8
11.1
9.2
0.50
Marking
0.25±0.05
4.10
0.51+0.10/-0.05
1 2 3
2.00
5 6 7 8
2.54
Bottom View
3.20
Recommended Footprint Details
1.00 Ø +0.15/-0
1 2 3
Pinning Information
Pin #
Single
1
-Vin
2
+Vin
3
CTRL
5
NC
6
+Vout
7
-Vout
8
NC
NC= no connection
Tolerance: ±0.25mm
5 6 7 8
Top View
7x2.54= 17.78
2.54
www.recom-power.com
REV.: 0/2021
ECO-5
RS3E
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
PACKAGING INFORMATION
Parameter
Type
Value
Packaging Dimension (LxWxH)
tube
520.0 x 11.2 x 18.2mm
Packaging Quantity
22pcs
Storage Temperature Range
Storage Humidity
-55°C to +125°C
non-condensing
95% RH max.
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 0/2021
ECO-6