RV-1212S/P/R6.4

RV-1212S/P/R6.4

  • 厂商:

    RECOM

  • 封装:

    DIP24

  • 描述:

    CONV DC/DC 2W 12VIN 12VOUT

  • 数据手册
  • 价格&库存
RV-1212S/P/R6.4 数据手册
Features Unregulated Converters • IEC60601-1 for medical applications • UL/CSA/IEC/EN safety certified and CB report • 6.4kVDC/1s or 8kVDC/1s reinforced isolation • Optional continuous short circuit protection • Efficiency up to 88% • Space saving package • Very low isolation capacitance Description 3300 76-80 1200 RV-xx09S (3,4) 3.3, 5, 12, 15, 24 9 222 78-85 1200 RV-xx12S (3,4) 3.3, 5, 12, 15, 24 12 167 78-85 680 ±5 ±200 75-82 ±470 3.3, 5, 12, 15, 24 ±9 ±111 76-84 ±470 RV-xx12D 3.3, 5, 12, 15, 24 ±12 ±85 78-86 ±220 3.3, 5, 12, 15, 24 ±15 ±66 78-86 ±220 (3,4) RV-xx15D (3,4) Notes: Note1: Efficiency is tested at nominal input and full load at +25°C ambient Note2: Max Cap Load is tested at nominal input and full resistive load Model Numbering Input Voltage Output Voltage RV-__ __S R Reinforced Isolation (3) Protection (4) Single or Dual C O M CONVER T RoHS 2 + compliant M 10 from 10 PL U D IA N T PRO C O M CONVER y T S 3.3, 5, 12, 15, 24 RV-xx09D (3,4) R RV-xx05D (3,4) E ±1500 REACH compliant CO 680 70-78 S 78-88 ±300 R 132 ±3.3 E 15 3.3, 5, 12, 15, 24 CO 3.3, 5, 12, 15, 24 RV-xx3.3D (3,4) M TS 70-78 400 C 600 5 RE 3.3 3.3, 5, 12, 15, 24 TS 3.3, 5, 12, 15, 24 RV-xx05S (3,4) C Output Output Efficiency max. Capacitive Voltage Current typ. (1) Load(2) [VDC] [mA] [%] [µF] arrant RE nom. Input Voltage [VDC] RV-xx3.3S (3,4) RV-xx15S 2 Watt 3 DIP24 miniature Single and Dual Output w Selection Guide (3,4) RV/R YEA R Very high isolation in a small size are the main features of this miniature DIP24 converter, ideal for highly sophisticated industrial, test and measurement and medical designs where board space is at a premium. Part Number DC/DC Converter PL U D IA N T PRO E314885 UL60950-1 certified CAN/CSA-C22.2 No. 60950-1 certified IEC/EN60950-1 certified ANSI/AAMI ES60601-1 certified CAN/CSA-C22.2 No. 60601-1 certified IEC/EN60601-1 certified IEC/EN61010 certified CB report Notes: Note3: add suffix „/R6.4“ for 6.4kVDC/1second isolation or „/R8“ for 8kVDC/1second isolation Note4: standard part is without continuous short circuit protection add suffix „/P“ for continuous short circuit protection Ordering Examples RV-1212D/R6.4 = 12V Input, 12V Output, Dual, 6.4kVDC/1s isolation RV-053.3S/P/R8 = 5V Input, 3.3V Output, Single, short circuit protection,8kVDC/1s isolation www.recom-power.com REV.: 6/2020 ECO-1 RV/R DC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) BASIC CHARACTERISTICS Parameter Condition Min. Typ. Input Voltage Range Max. ±10% Minimum Load 0% Internal Operating Frequency 20kHz Output Ripple and Noise 50kHz 85kHz 20MHz BW 200mVp-p Efficiency vs. Load RV-xx05D/R6.4 and RV-xx05D/R8 100 100 90 90 80 80 70 70 Efficiency [%] Efficiency [%] RV-xx05S/R6.4 and RV-xx05S/R8 60 50 40 60 50 40 30 30 0505 1205 2405 20 10 0 0 10 20 30 40 50 60 70 80 90 0505 1205 2405 20 10 0 100 0 10 20 30 Output Load [%] 40 50 60 70 80 90 100 Output Load [%] REGULATIONS Parameter Condition Value Output Accuracy ±5.0% max. Line Regulation low line to high line 20.0% max. 15.0% max. 10.0% max. 3.3Vout 5Vout 9, 12, 15Vout 10% to 100% load Load Regulation (5) ±1.2% of 1.0% Vin typ. Notes: Note5: Operation below 10% load will not harm the converter, but specifications may not be met Tolerance Envelope 9, 12, 15, 24Vout Output Voltage [%] +10% +6% Typica l +5% Load L ine Vnom -2.5% -5% 10 50 100 Output Load [%] continued on next page www.recom-power.com REV.: 6/2020 ECO-2 RV/R DC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) Deviation vs. Load RV-xx05S/R6.4 and RV-xx05S/R8 RV-xx05D/R6.4 and RV-xx05D/R8 25 25 0505 1205 2405 20 15 Deviation [%] Deviation [%] 15 10 5 10 5 0 0 -5 -5 -10 0505 1205 2405 20 0 10 20 30 40 50 60 70 80 90 -10 100 0 10 20 Output Load [%] 30 40 50 60 70 80 90 100 Output Load [%] PROTECTIONS Parameter Type Short Circuit Protection (SCP) Isolation Voltage 1 second continuous “/R6.4” tested for 1 second rated for 1 minute 6.4kVDC 3.2kVAC/60Hz “/R8” tested for 1 second rated for 1 minute 8kVDC 4kVAC/60Hz 15GΩ min. I/P to O/P (6) Value without suffix with suffix “/P” Isolation Resistance Isolation Capacitance 2pF min. / 12pF max. Insulation Grade reinforced 34Vr.m.s. 2MOPP Internal clearance/creepage >4.8mm External clearance/creepage >4.8mm Means of Protection Notes: Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage Note7: Refer to local safety regulations if input over-current protection is required. Recommended fuse: slow blow type www.recom-power.com REV.: 6/2020 ECO-3 RV/R DC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) ENVIRONMENTAL Parameter Condition Operating Temperature Range Value full load @ free air convection (see graph) Operating Altitude -40°C to +85°C 3000m Operating Humidity non-condensing 95% RH max. Pollution Degree PD2 MTBF according to MIL-HDBK-217F, G.B. +25°C +85°C 1154 x 103 hours 168 x 103 hours Derating Graph (@ free air convection) 100 90 Output Load [%] 80 70 60 50 40 30 20 10 0 -40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110 85 Ambient Temperature [°C] SAFETY AND CERTIFICATIONS Certificate Type (Safety) Report / File Number Information Technology Equipment, General Requirements for Safety 2236395 Information Technology Equipment, General Requirements for Safety LVD1605077-14 Medical Electrical Equipment Part 1: General Requirements for Basic Safety and Essential Performance E314885-A5-UL Medical Electrical Equipment Part 1: General Requirements for Basic Safety and Essential Performance (CB Scheme) E314885-A5-CB-1 Medical Electrical Equipment Part 1: General Requirements for Basic Safety and Essential Performance WD-SE-R-180539-A0 Standard ANSI/UL60950-1, 1st Edition CAN/CSA C22.2 No. 60950-1-03 IEC60950-1-2005 , 2nd Edition + A2:2013 EN60950-1: 2006 + A2:2013 ANSI/AAMI ES60601-1:2005 + A2:10 CAN/CSA-C22.2 No. 60601-1:2008 IEC60601-1:2005 + C2:2007 IEC60601-1:2005 + A1:2012, 3rd Edition EN60601-1:2006 + A12:2014 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 1: General requirements T1301251-313 EN61010:2010 IEC61010:2010 EAC RU-AT.49.09571 TP TC 004/2011 RoHS 2+ EMC Compliance Electromagnetic compatibility of multimedia equipment Emission requirements RoHS-2011/65/EU + AM-2015/863 Condition with external filter (refer to “EMC Filter Suggestion” below) Standard / Criterion EN55032, Class A EN55032, Class B continued on next page www.recom-power.com REV.: 6/2020 ECO-4 RV/R DC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) EMC Filter Suggestion according to EN55032 L1 +Vin C1 +Vin +Vout -Vin -Vout +Vout C2 -Vin -Vout C3 Component List Class A Model RV/R6.4 RV/R8 C1 C2 N/A 10µF C3 2n2F 8kV 2n5F 10kV L1 N/A Component List Class B Model RV/R6.4 RV/R8 C1 C2 10µF 10µF C3 L1 2n2F 8kV 470µH WE7447471471 2n5F 10kV DIMENSION AND PHYSICAL CHARACTERISTICS Parameter Type Value Material case potting PCB non-conductive black plastic, (UL94 V-0) silicone, (UL94 V-0) FR4, (UL94 V-0) Dimension (LxWxH) 32.35 x 14.7 x 11.1mm Weight 9.0g typ. Dimension Drawing (mm) embossed logo 14.7 32.35 Pinning Information 0.5±0.05 15.24 4.10 0.60 0.40 11.1 14.4 0.25±0.1 16.95 max. Recommended Footprint Details 1.00Ø +0.15/-0 8 9 10 11 12 Bottom View 24 23 2.2 www.recom-power.com 24 23 1 2 17 16 15 14 13 11x2.54= 27.94 17 16 15 14 13 Top View 2.54 1 2 Pin # 1 2 8, 17 9, 11, 14 10, 15 12, 13 16, 23, 24 Single +Vin -Vin NC NC -Vout +Vout NC Dual +Vin -Vin -Vout NC Com +Vout NC NC= No Connection Tolerance: xx.x= ±0.5mm xx.xx= ±0.25mm 8 9 10 11 12 2.54 REV.: 6/2020 ECO-5 RV/R DC/DC Converter Series Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) PACKAGING INFORMATION Parameter Type Value Packaging Dimension (LxWxH) tube 530.0 x 21.0 x 18.0mm Packaging Quantity tube 15pcs Storage Temperature Range Storage Humidity -55°C to +125°C non-condensing 95% RH max. The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized use of RECOM products in such safety-critical applications. www.recom-power.com REV.: 6/2020 ECO-6
RV-1212S/P/R6.4 价格&库存

很抱歉,暂时无法提供与“RV-1212S/P/R6.4”相匹配的价格&库存,您可以联系我们找货

免费人工找货