Features
Unregulated
Converters
• IEC60601-1 for medical applications
• UL/CSA/IEC/EN safety certified and CB report
• 6.4kVDC/1s or 8kVDC/1s reinforced isolation
• Optional continuous short circuit protection
• Efficiency up to 88%
• Space saving package
• Very low isolation capacitance
Description
3300
76-80
1200
RV-xx09S
(3,4)
3.3, 5, 12, 15, 24
9
222
78-85
1200
RV-xx12S (3,4)
3.3, 5, 12, 15, 24
12
167
78-85
680
±5
±200
75-82
±470
3.3, 5, 12, 15, 24
±9
±111
76-84
±470
RV-xx12D
3.3, 5, 12, 15, 24
±12
±85
78-86
±220
3.3, 5, 12, 15, 24
±15
±66
78-86
±220
(3,4)
RV-xx15D (3,4)
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Max Cap Load is tested at nominal input and full resistive load
Model Numbering
Input Voltage
Output Voltage
RV-__ __S R
Reinforced Isolation (3)
Protection (4)
Single or Dual
C
O
M
CONVER
T
RoHS 2 +
compliant
M
10 from 10
PL
U
D
IA N
T PRO
C
O
M
CONVER
y
T
S
3.3, 5, 12, 15, 24
RV-xx09D (3,4)
R
RV-xx05D (3,4)
E
±1500
REACH
compliant
CO
680
70-78
S
78-88
±300
R
132
±3.3
E
15
3.3, 5, 12, 15, 24
CO
3.3, 5, 12, 15, 24
RV-xx3.3D (3,4)
M
TS
70-78
400
C
600
5
RE
3.3
3.3, 5, 12, 15, 24
TS
3.3, 5, 12, 15, 24
RV-xx05S (3,4)
C
Output
Output
Efficiency max. Capacitive
Voltage Current typ. (1) Load(2)
[VDC] [mA] [%] [µF]
arrant
RE
nom. Input
Voltage
[VDC]
RV-xx3.3S (3,4)
RV-xx15S
2 Watt
3
DIP24
miniature
Single and Dual
Output
w
Selection Guide
(3,4)
RV/R
YEA R
Very high isolation in a small size are the main features of this miniature DIP24 converter, ideal
for highly sophisticated industrial, test and measurement and medical designs where board space is
at a premium.
Part
Number
DC/DC Converter
PL
U
D
IA N
T PRO
E314885
UL60950-1 certified
CAN/CSA-C22.2 No. 60950-1 certified
IEC/EN60950-1 certified
ANSI/AAMI ES60601-1 certified
CAN/CSA-C22.2 No. 60601-1 certified
IEC/EN60601-1 certified
IEC/EN61010 certified
CB report
Notes:
Note3: add suffix „/R6.4“ for 6.4kVDC/1second isolation
or „/R8“ for 8kVDC/1second isolation
Note4: standard part is without continuous short circuit protection
add suffix „/P“ for continuous short circuit protection
Ordering Examples
RV-1212D/R6.4 = 12V Input, 12V Output, Dual, 6.4kVDC/1s isolation
RV-053.3S/P/R8 = 5V Input, 3.3V Output, Single, short circuit protection,8kVDC/1s isolation
www.recom-power.com
REV.: 6/2020
ECO-1
RV/R
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
BASIC CHARACTERISTICS
Parameter
Condition
Min.
Typ.
Input Voltage Range
Max.
±10%
Minimum Load
0%
Internal Operating Frequency
20kHz
Output Ripple and Noise
50kHz
85kHz
20MHz BW
200mVp-p
Efficiency vs. Load
RV-xx05D/R6.4 and RV-xx05D/R8
100
100
90
90
80
80
70
70
Efficiency [%]
Efficiency [%]
RV-xx05S/R6.4 and RV-xx05S/R8
60
50
40
60
50
40
30
30
0505
1205
2405
20
10
0
0
10
20
30
40
50
60
70
80
90
0505
1205
2405
20
10
0
100
0
10
20
30
Output Load [%]
40
50
60
70
80
90
100
Output Load [%]
REGULATIONS
Parameter
Condition
Value
Output Accuracy
±5.0% max.
Line Regulation
low line to high line
20.0% max.
15.0% max.
10.0% max.
3.3Vout
5Vout
9, 12, 15Vout
10% to 100% load
Load Regulation (5)
±1.2% of 1.0% Vin typ.
Notes:
Note5: Operation below 10% load will not harm the converter, but specifications may not be met
Tolerance Envelope
9, 12, 15, 24Vout
Output Voltage [%]
+10%
+6%
Typica
l
+5%
Load L
ine
Vnom
-2.5%
-5%
10
50
100
Output Load [%]
continued on next page
www.recom-power.com
REV.: 6/2020
ECO-2
RV/R
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Deviation vs. Load
RV-xx05S/R6.4 and RV-xx05S/R8
RV-xx05D/R6.4 and RV-xx05D/R8
25
25
0505
1205
2405
20
15
Deviation [%]
Deviation [%]
15
10
5
10
5
0
0
-5
-5
-10
0505
1205
2405
20
0
10
20
30
40
50
60
70
80
90
-10
100
0
10
20
Output Load [%]
30
40
50
60
70
80
90
100
Output Load [%]
PROTECTIONS
Parameter
Type
Short Circuit Protection (SCP)
Isolation Voltage
1 second
continuous
“/R6.4”
tested for 1 second
rated for 1 minute
6.4kVDC
3.2kVAC/60Hz
“/R8”
tested for 1 second
rated for 1 minute
8kVDC
4kVAC/60Hz
15GΩ min.
I/P to O/P
(6)
Value
without suffix
with suffix “/P”
Isolation Resistance
Isolation Capacitance
2pF min. / 12pF max.
Insulation Grade
reinforced
34Vr.m.s.
2MOPP
Internal
clearance/creepage
>4.8mm
External
clearance/creepage
>4.8mm
Means of Protection
Notes:
Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note7: Refer to local safety regulations if input over-current protection is required. Recommended fuse: slow blow type
www.recom-power.com
REV.: 6/2020
ECO-3
RV/R
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
ENVIRONMENTAL
Parameter
Condition
Operating Temperature Range
Value
full load @ free air convection (see graph)
Operating Altitude
-40°C to +85°C
3000m
Operating Humidity
non-condensing
95% RH max.
Pollution Degree
PD2
MTBF
according to MIL-HDBK-217F, G.B.
+25°C
+85°C
1154 x 103 hours
168 x 103 hours
Derating Graph
(@ free air convection)
100
90
Output Load [%]
80
70
60
50
40
30
20
10
0
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110
85
Ambient Temperature [°C]
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report / File Number
Information Technology Equipment, General Requirements for Safety
2236395
Information Technology Equipment, General Requirements for Safety
LVD1605077-14
Medical Electrical Equipment Part 1: General Requirements for Basic
Safety and Essential Performance
E314885-A5-UL
Medical Electrical Equipment Part 1: General Requirements for Basic
Safety and Essential Performance (CB Scheme)
E314885-A5-CB-1
Medical Electrical Equipment Part 1: General Requirements for Basic
Safety and Essential Performance
WD-SE-R-180539-A0
Standard
ANSI/UL60950-1, 1st Edition
CAN/CSA C22.2 No. 60950-1-03
IEC60950-1-2005 , 2nd Edition + A2:2013
EN60950-1: 2006 + A2:2013
ANSI/AAMI ES60601-1:2005 + A2:10
CAN/CSA-C22.2 No. 60601-1:2008
IEC60601-1:2005 + C2:2007
IEC60601-1:2005 + A1:2012, 3rd Edition
EN60601-1:2006 + A12:2014
Safety requirements for electrical equipment for measurement, control
and laboratory use - Part 1: General requirements
T1301251-313
EN61010:2010
IEC61010:2010
EAC
RU-AT.49.09571
TP TC 004/2011
RoHS 2+
EMC Compliance
Electromagnetic compatibility of multimedia equipment Emission requirements
RoHS-2011/65/EU + AM-2015/863
Condition
with external filter
(refer to “EMC Filter Suggestion” below)
Standard / Criterion
EN55032, Class A
EN55032, Class B
continued on next page
www.recom-power.com
REV.: 6/2020
ECO-4
RV/R
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
EMC Filter Suggestion according to EN55032
L1
+Vin
C1
+Vin
+Vout
-Vin
-Vout
+Vout
C2
-Vin
-Vout
C3
Component List Class A
Model
RV/R6.4
RV/R8
C1
C2
N/A
10µF
C3
2n2F 8kV
2n5F 10kV
L1
N/A
Component List Class B
Model
RV/R6.4
RV/R8
C1
C2
10µF
10µF
C3
L1
2n2F 8kV
470µH
WE7447471471
2n5F 10kV
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter
Type
Value
Material
case
potting
PCB
non-conductive black plastic, (UL94 V-0)
silicone, (UL94 V-0)
FR4, (UL94 V-0)
Dimension (LxWxH)
32.35 x 14.7 x 11.1mm
Weight
9.0g typ.
Dimension Drawing (mm)
embossed logo
14.7
32.35
Pinning Information
0.5±0.05
15.24
4.10
0.60
0.40
11.1
14.4
0.25±0.1
16.95 max.
Recommended Footprint Details
1.00Ø +0.15/-0
8 9 10 11 12
Bottom View
24 23
2.2
www.recom-power.com
24 23
1 2
17 16 15 14 13
11x2.54= 27.94
17 16 15 14 13
Top View
2.54
1 2
Pin #
1
2
8, 17
9, 11, 14
10, 15
12, 13
16, 23, 24
Single
+Vin
-Vin
NC
NC
-Vout
+Vout
NC
Dual
+Vin
-Vin
-Vout
NC
Com
+Vout
NC
NC= No Connection
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.25mm
8 9 10 11 12
2.54
REV.: 6/2020
ECO-5
RV/R
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
PACKAGING INFORMATION
Parameter
Type
Value
Packaging Dimension (LxWxH)
tube
530.0 x 21.0 x 18.0mm
Packaging Quantity
tube
15pcs
Storage Temperature Range
Storage Humidity
-55°C to +125°C
non-condensing
95% RH max.
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 6/2020
ECO-6