Features
Unregulated Converters
●
● ● ● ● ● ●
Safety standards and approvals: EN 60950 certified, rated for 250VAC (LVD test report) UL-60950-1 / CSA C22.2 certified 6kVDC Isolation UL94V-0 Package Material Optional Continuous Short Circuit Protected Fully Encapsulated Efficiency to 82%
ECONOLINE
DC/DC-Converter
RV Series
2 Watt DIP24 Miniature Single & Dual Output
Selection Guide
Part Number DIP24 (SMD) Miniature RV-xx3.3S RV-xx05S RV-xx09S RV-xx12S RV-xx15S RV-xx24S RV-xx3.3D RV-xx05D RV-xx09D RV-xx12D RV-xx15D Input Voltage (VDC) 3.3, 5, 9, 12, 15, 24 3.3, 5, 9, 12, 15, 24 3.3, 5, 9, 12, 15, 24 3.3, 5, 9, 12, 15, 24 3.3, 5, 9, 12, 15, 24 3.3, 5, 9, 12, 15, 24 3.3, 5, 12, 15, 24 3.3, 5, 12, 15, 24 3.3, 5, 12, 15, 24 3.3, 5, 12, 15, 24 3.3, 5, 12, 15, 24 Rated Output Voltage (VDC) 3.3 5 9 12 15 24 ±3.3 ±5 ±9 ±12 ±15 Output Current Full Load (mA) 600 400 222 167 133 83 ±300 ±200 ±111 ±83 ±67 ±42
RV-xx24D 3.3, 5, 12, 15, 24 ±24 xx = Input Voltage * add Suffix “P” for Continuous Short Circuit Protection, e.g. RV-0505S/P, RV-0505D/P
EN-60950-1 Certified UL-60950-1 Certified EN-60601-1 Certified
Specifications (Core Operating Area)
Input Voltage Range Output Voltage Accuracy Line Voltage Regulation Load Voltage Regulation (10% to 100% full load) Output Ripple and Noise (20MHz limited) Operating Frequency Efficiency at Full Load No Load Power Consumption Isolation Voltage Rated Working Voltage Isolation Capacitance Isolation Resistance Short Circuit Protection P-Suffix Operating Temperature Range (free air convection) Storage Temperature Range Relative Humidity Package Weight MTBF (+25°C) (+85°C) (tested for 1 second) (long term isolation) 3.3V output types 5V output type 9V, 12V, 15V, 24V output types ±10% ±5% 1.2%/1% of Vin typ. 20% max. 15% max. 10% max. 200mVp-p max. 20kHz min. / 50kHz typ. / 85kHz max. 70% min. / 75% typ. 282mW min. / 338mW typ. / 430mW max. 6000VDC min. see Application Notes
Output Power (%)
100 80 60 40 20 0 -40 0 50 100 150
Derating-Graph
(Ambient Temperature)
2pF min. / 12pF max. 15 GΩ min. 1 Second Continuous -40°C to +85°C (see Graph) -55°C to +125°C 95% RH 9g
Safe Operating Area
85 Operating Temperature °C
}
Detailed Information see Application Notes chapter "MTBF"
using MIL-HDBK 217F using MIL-HDBK 217F July-2006
1154 x 103 hours 168 x 103 hours 91
www.recom-international.com
ECONOLINE
DC/DC-Converter
Typical Characteristics
RV Series
RV-xx09S
Efficiency / Load
100
RV-xx05S
Efficiency / Load
100 80 60 40
RV-xx12S
Efficiency / Load
100 80
1205
1209
80 60
1212
0505 Efficiency %
0509 Efficiency %
60 40 20 0
40 20 0
0512
Efficiency %
20 0
0%
20%
40%
60%
80%
100%
0%
20%
40%
60%
80%
100%
0%
20%
40%
60%
80%
100%
Total Output current (%)
Total Output current (%)
Total Output current (%)
Deviation / Load
25.000 20.000 25.000 20.000
Deviation / Load
25.000 20.000
Deviation / Load
Deviation from Nominal (%)
Deviation from Nominal (%)
15.000 10.000 5.000 0.000 -5.000 -10.000
15.000 10.000 5.000 0.000 -5.000 -10.000
Deviation from Nominal (%)
0505
0509
15.000 10.000 5.000 0.000 -5.000 -10.000
0512
1205
1209
1212
0% 20% 40% 60% Total Output current (%)
80%
100%
0% 20% 40% 60% Total Output current (%)
80%
100%
0% 20% 40% 60% Total Output current (%)
80%
100%
RV-xx15S
Efficiency / Load
100 80 60 40 100
RV-xx05D
Efficiency / Load
80 60
RV-xx09D
Efficiency / Load
100 80 60 40
1215
0505
1205
1209
0515 Efficiency %
0509
40 20 0
Efficiency %
Efficiency %
0% 40% 100%
20 0
20 0
0%
20%
40%
60%
80%
100%
20%
60%
80%
0%
20%
40%
60%
80%
100%
Total Output current (%)
Total Output current (%)
Total Output current (%)
Deviation / Load
25.000 20.000 25.000 20.000
Deviation / Load
25.000 20.000
Deviation / Load
Deviation from Nominal (%)
Deviation from Nominal (%)
Deviation from Nominal (%)
15.000 10.000 5.000 0.000 -5.000 -10.000
0515
15.000 10.000 5.000 0.000 -5.000 -10.000
0505
15.000 10.000 5.000 0.000 -5.000 -10.000
0509
1215
1205
1209
0% 20% 40% 60% Total Output current (%)
80%
100%
0% 20% 40% 60% Total Output current (%)
80%
100%
0% 20% 40% 60% Total Output current (%)
80%
100%
92
July-2006
www.recom-international.com
ECONOLINE
DC/DC-Converter
Typical Characteristics
RV Series
RV-xx15D
Efficiency / Load
100 80 60
RV-xx12D
Efficiency / Load
100 80 60 40
1212
1215
0512 Efficiency %
40 20 0
0515
Efficiency %
20 0
0%
20%
40%
60%
80%
100%
0%
20%
40%
60%
80%
100%
Total Output current (%)
Total Output current (%)
Deviation / Load
25.000 20.000 25.000 20.000
Deviation / Load
Deviation from Nominal (%)
Deviation from Nominal (%)
15.000 10.000 5.000 0.000 -5.000 -10.000
0512
15.000 10.000 5.000 0.000 -5.000 -10.000
0515
1212
1215
0% 20% 40% 60% Total Output current (%)
80%
100%
0% 20% 40% 60% Total Output current (%)
80%
100%
Package Style and Pinning (mm)
3rd angle projection
24 PIN DIP Miniature Package Style
2.54 x 11
14.70
Single & Dual Output
24 23
17 16 15 14 13
11.40 4.10 0.25 15.24 0.50±0.05 16.95 max. 12
RECOM RV-0505S
****
8 9 10 11 12
0.60
Recommended Footprint Details
32.35 max. 12 16.10 24 23 8 9 10 11 12 Bottom View 17 16 15 14 13
Top View
Pin Connections Pin # 1 2 8, 9, 11, 14 10, 15 12 & 13
Pin Connections
2.54
1.0ø+0.15/0
Single
+Vin -Vin NC -Vout +Vout NC
Pin # 1 2 8, 17 9, 11, 14,16, 23, 24 10 & 15 12, 13 NC = No Connection
Dual
+Vin -Vin -Vout NC Com +Vout
2.54 16, 17, 23, 24
NC = No Connection
XX.X ± 0.5 mm XX.XX ± 0.25 mm
www.recom-international.com
July-2006
93