DC/DC Converter
RW2
Description
YEA R
RW2-1205S
9-18 5 400 75 1000
RW2-1212S
9-18 12 166 80 1000
RW2-1215S
9-18 15 134 80 1000
RW2-243.3S
C
RW2-2415S
18-36 15 134 83 1000
RW2-483.3S
36-72 3.3 500 73 4700
RW2-4805S
36-72 5 400 76 1000
RW2-4812S
36-72 12 166 81 1000
RW2-4815S
36-72 15 134 81 1000
RW2-0505D
4.5-9 ±5 ±200 73
±680
RW2-0509D
4.5-9 ±9 ±111 74
±680
RW2-0512D
4.5-9 ±12 ±83 75
±680
RW2-0515D
4.5-9 ±15 ±67 75
±680
RW2-1205D
9-18 ±5 ±200 75
±680
RW2-1209D
9-18 ±9 ±111 78
±680
RW2-1212D
9-18 ±12 ±83 80
±680
RW2-1215D
9-18 ±15 ±67 80
±680
RW2-2405D
18-36 ±5 ±200 78
±680
RW2-2409D
18-36 ±9 ±111 81
±680
RW2-2412D
18-36 ±12 ±83 83
±680
RW2-2415D
18-36 ±15 ±67 83
±680
RW2-4805D
36-72 ±5 ±200 78
±680
RW2-4809D
36-72 ±9 ±111 81
±680
RW2-4812D
36-72 ±12 ±83 83
±680
RW2-4815D
36-72 ±15 ±67 83
±680
CONVER
T
M
10 from 10
PL
U
D
IA N
T PRO
C
O
M
CONVER
y
T
REACH
compliant
CO
18-36 12 166 83 1000
CO
18-36 5 400 78 1000
RW2-2412S
M
RoHS 2 +
compliant
18-36 3.3 500 70 4700
RW2-2405S
O
M
TS
9-18 3.3 500 69 4700
C
4.5-9 15 134 75 1000
RW2-123.3S
S
RW2-0515S
R
4.5-9 12 166 75 1000
E
4.5-9 5 400 73 1000
RW2-0512S
S
RW2-0505S
R
4.5-9 3.3 500 68 4700
E
RW2-053.3S
RE
Input
Output
Output
Efficiency max. Capacitive
Voltage Range
Voltage
Current
typ.(1) Load (2)
[VDC] [VDC] [mA] [%]
[µF]
TS
Selection Guide
arrant
w
High power-density, 2:1 input voltage range and a wide temperature range of -40°C to +85°C are just
some of the characteristics of this versatile DIP16 converter, ideal for highly sophisticated industrial
designs where a regulated converter is required but space is at a premium. Three different case styles
and isolation options are available.
Part
Number
2 Watt
3
MINI DIP16,
DIP16 or SMD
Single & Dual
Output
C
Regulated
Converters
• DIP16, Mini DIP16 or SMD package style
• 1kVDC, 2kVDC or 3kVDC isolation
• Continuous short circuit protected
• Low ripple and noise
• IEC/EN60950-1 certified
• Efficiency up to 83%
RE
Features
PL
U
D
IA N
T PRO
IEC/EN60950-1 certified
Notes:
Note1: Efficiency is tested at nominal input and full load at +25°C ambient
Note2: Maximum capacitive load is defined as the capacitive load that will allow
start up in under 1 second without damage on the converter
www.recom-power.com
REV.: 2/2020
ECO-1
RW2
DC/DC Converter
Series
Model Numbering
RW2- __ __ _ /__ _
nom. Input Voltage
Case Style (4)
Output Voltage
Isolation (3)
Single or Dual
Notes:
Note3:
„/H2“ = 2kVDC isolation; „/H3“ = 3kVDC isolation; without suffix standard 1kVDC isolation
Note4: add suffix „/SMD“ for SMD package or „/B“ for Mini DIP16 THT package;
without suffix = standard DIP16 package (refer to “DIP16”)
Ordering Examples:
RW2-2405S/B:
RW2-1212D/H2:
RW2-0515D/H3/SMD:
RW2-4812S/H2/B
18-36Vin
9-18Vin
4.5-9Vin
36-72Vin
5Vout
±12Vout
±15Vout
12Vout
Single
Dual
Dual
Single
1kVDC Isolation
2kVDC Isolation
3kVDC Isolation
2kVDC Isolation
Mini DIP16 Package
DIP16 Package
SMD Package
Mini DIP16 Package
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
BASIC CHARACTERISTICS
Parameter
Condition
Input Voltage Range
Min.
4.5VDC
9VDC
18VDC
36VDC
5VDC
12VDC
nom. Vin=
24VDC
48VDC
Minimum Load (5)
Max.
9VDC
18VDC
36VDC
72VDC
10%
100KHz
Internal Operating Frequency
Output Ripple and Noise
Typ.
20MHz BW
700kHz
50mVp-p
Notes:
Note5: Operation below 10% load won‘t harm the converter, but specifications may not be met.
REGULATIONS
Parameter
Condition
Value
Output Accuracy
±2.0% typ.
Line Regulation
±0.5% max.
Load Regulation
20% to 100% load
0.5% typ.
PROTECTION
Parameter
Type
Value
Short Circuit Protection (SCP)
Isolation Voltage (6)
continous
standard without suffix
tested for 1 second
rated for 1 minute
1kVDC
500VAC/60Hz
/H2 version
tested for 1 second
rated for 1 minute
2kVDC
1kVAC/60Hz
/H3 version
tested for 1 second
rated for 1 minute
3kVDC
1.5kVAC/60Hz
1GΩ min.
Isolation Resistance
Isolation Capacitance
30pF max.
Insulation Grade
functional
Notes:
Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage
Note7: Refer to local safety regulations if input over-current protection is also required. Recommended fuse: slow blow type
www.recom-power.com
REV.: 2/2020
ECO-2
RW2
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
ENVIRONMENTAL
Parameter
Condition
Operating Temperature Range
Value
full load @ free air convection (see graph)
-40°C to +85°C
Maximum Case Temperature
+100°C
Operating Altitude
2000m
Operating Humidity
non-condensing
95% RH max.
Pollution Degree
PD2
MTBF
4366 x 10 hours
658 x 103 hours
+25°C
+85°C
according to MIL-HDBK-217F, G.B.
3
Derating Graph
(@ Chamber and free air convection)
100
90
Output Load [%]
80
70
60
50
40
30
20
10
0
-40 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 110
85 95
Ambient Temperature [°C]
SAFETY AND CERTIFICATIONS
Certificate Type (Safety)
Report / File Number
Standard
Information Technology Equipment, General Requirements for Safety
SPCLVD1605077-10
IEC60950-1:2005, 2nd Edition + A2:2013
EN60950-1:2006 + A2:2013
Medical Electric Equipment, General Requirements for Safety and
Essential Performance
WD-SE-R-180675-A0
IEC60601-1:2005, 3rd Edition + A1:2012
EN60601-1:2006 + A12:2014
EAC
RU-AT.AB49.B.09571
TP TC 004/2011
RoHS2+
RoHS-2011/65/EU
TWNC00635328
EMC Compliance
Condition
Electromagnetic compatibility of multimedia equipment Emission requirements (8)
Standard / Criterion
with external filter
(see filter suggestion below)
EN55032, Class A
EN55032, Class B
EMC Filtering Suggestions according to EN55032
L1
+Vin
+Vin
+Vout
Component List Class A
+Vout
Models
C1
-Vin
-Vin
-Vout
RW2-1212S/H2/SMD 10µF/100V
MLCC
RW2-2405S/H2
-Vout
C2
L1
330pF
5.6µH choke RLS-567
C2
L1
330pF
22µH choke RLS-226
Component List Class B
C2
Models
Notes:
Note8: Filter suggestions are valid for indicated part numbers only.
For other part numbers, please contact RECOM tech support for advice.
www.recom-power.com
C1
REV.: 2/2020
C1
RW2-1212S/H2/SMD 10µF/100V
MLCC
RW2-2405S/H2
ECO-3
RW2
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
DIMENSION AND PHYSICAL CHARACTERISTICS
Parameter
Type
Value
non-conductive black plastic, (UL94 V-0)
epoxy, (UL94 V-0)
FR4, (UL94 V-0)
22.1 x 12.55 x 8.50mm
24.2 x 14.50 x 9.70mm
24.2 x 14.50 x 10.20mm
case
potting
PCB
Mini DIP16
DIP16
SMD
Material
Dimension (LxWxH)
Weight
6.4g typ.
Dimension Drawing (mm)
DIP16
embossed logo
14.50
9.70
24.2
11.10
Pinning information
0.25
4.60
0.50
Recommended Footprint Details
Ø1.0 +0.15/-0
7 8
16
Bottom View
16
10 9
1
6x2.54=15.24
3.2
10 9
Dual
-Vin
NC
Com
+Vout
-Vout
+Vin
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.35mm
Top View
2.54
16.90
1
Pin # Single
1
-Vin
7
NC
8
NC
9
+Vout
10
-Vout
16
+Vin
7 8
2.54
Mini DIP16 (/B)
embossed logo
12.55
8.50
22.1
Pinning information
4.00
Ø0.51
Recommended Footprint Details
1
7 8
2.54
7.62
Ø1.0 +0.15/-0
16
Bottom View
16
2.16
1
10 9
6x2.54=15.24
10 9
Top View
7 8
Pin # Single
1
-Vin
7
NC
8
NC
9
+Vout
10
-Vout
16
+Vin
Dual
-Vin
NC
Com
+Vout
-Vout
+Vin
Tolerance: xx.x= ±0.5mm
xx.xx= ±0.35mm
2.54
continued on next page
www.recom-power.com
REV.: 2/2020
ECO-4
RW2
DC/DC Converter
Series
Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated)
Dimension Drawing SMD (mm)
SMD (/SMD)
embossed logo
Pinning information
Pin # Single
1
-Vin
7
NC
8
NC
9
+Vout
10
-Vout
16
+Vin
14.50
0.25
10.20
9.7
24.2
2.54
18.55
2.54
16.0
16
1.54
Tolerance: xx.x=±0.5mm
xx.xx=±0.35mm
7 8
19.27
17.24
1
Bottom View
0.50
2.03
Recommended Footprint Details
Pin area
0.1 x 0.50
Dual
-Vin
NC
Com
+Vout
-Vout
+Vin
Top View
10 9
6 x 2.54= 15.24
7 x 2.54= 17.78
PACKAGING INFORMATION
Parameter
Type
Value
Packaging Dimension (LxWxH)
tube
530.0 x 21.0 x 18.0mm
Packaging Quantity
DIP16 and SMD
Mini DIP16
Storage Temperature Range
Storage Humidity
20pcs
22pcs
-55°C to +125°C
non-condensing
95% RH max.
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The
products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause
loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.
www.recom-power.com
REV.: 2/2020
ECO-5