BR305
THRU
BR310
SINGLE-PHASE SILICON BRIDGE RECTIFIER
VOLTAGE RANGE 50 to 1000 Volts CURRENT 3.0 Amperes
FEATURES
*Surge overload rating: 50 amperes peak
* Low forward voltage drop
BR-3
MECHANICAL DATA
*
*
*
*
UL listed the recognized component directory, file #E94233
Epoxy: Device has UL flammability classification 94V-O
Lead: Mil-STD-202E method 208C guaranteed
Mounting position: Any
.270(6.86)
.230(5.84)
.925
MIN.
(23.5)
.032 (0.81)
.028 (0.71)
.750
(19.1)
MIN.
.158 (4.0)
(+ )
.154 (3.9)
AC
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
.620(15.71)
.580(14.96)
o
Ratings at 25 C ambient temperature unless otherwise specified.
AC
Single phase, half wave, 60 Hz, resistive or inductive load.
For capacitive load, derate current by 20%.
.445(11.31)
.405(10.29)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (At T A = 25 C unless otherwise noted)
o
SYMBOL
BR305
BR31
BR32
Maximum Recurrent Peak Reverse Voltage
VRRM
50
100
Maximum RMS Voltage
VRMS
35
50
70
RATINGS
VDC
Maximum DC Blocking Voltage
Maximum Average Forward Tc = 50o C
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
$VSSFOU4RVBSBE5JNF
Operating Temperature Range
Storage Temperature Range
100
BR34
BR36
BR38
BR310
UNITS
200
400
140
200
280
400
600
800
1000
Volts
420
600
560
700
1000
Volts
800
Volts
IO
3.0
Amps
I FSM
50
Amps
*U
10.3
" 4FD
TJ
-55 to + 150
0
C
T STG
-55 to + 150
0
C
ELECTRICAL CHARACTERISTICS (At TA = 25 C unless otherwise noted)
o
SYMBOL
CHARACTERISTICS
VF
Maximum Forward Voltage Drop per element at 1.5A DC
Maximum Reverse Current at Rated
@T A = 25 C
@T C = 100 C
o
BR31
BR32
BR34
1.0
5.0
o
DC Blocking Voltage per element
BR305
IR
NOTES : 1. Thermal Resistance : Mounted on PCB.
2. “ RoHS compliant”
3. Available in Halogen-free epoxy by adding suffix -HF after the part nbr.
BR36
BR38
BR310
UNITS
Volts
uAmps
200
2021-11
REV: D
RATING AND CHARACTERISTIC CURVES ( BR305 THRU BR310 )
FIG. 2 - TYPICAL FORWARD CURRENT
DERATING CURVE
FIG. 1 - MAXIMUM NON-REPETITIVE FORWARD
AVERAGE FORWARD CURRENT, (A)
PEAK FORWARD SURGE CURRENT, (A)
SURGE CURRENT
100
8.3ms Single Half Sine-Wave
(JEDEC Method)
80
60
40
20
5
4
CAS
E
3
2
60 Hz RESISTIVE OR
INDUCTIVE LOAD
1
0
0
1
2
0
4 6 8 10
20
40 6080100
NUMBER OF CYCLES AT 60Hz
50
100
CASE TEMPERATURE, (
150
)
FIG. 4- TYPICAL REVERSE CHARACTERISTICS
FIG. 3- TYPICAL INSTANTANEOUS FORWARD
100
TJ = 25
Pulse Width = 300us
1% Duty Cycle
INSTANTANEOUS REVERSE CURRENT, (uA)
INSTANTANEOUS FORWARD CURRENT, (A)
CHARACTERISTICS
10
1.0
.1
.01
0
.5
1.0
1.5
2.0
2.5
3.0
3.5
1000
100
O
TA = 100 C
10
1
O
TA = 25 C
0.1
0
20
40
60
80
100
120
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
INSTANTANEOUS FORWARD VOLTAGE, (V)
RECTRON
140
RECTRON
Attachment information about BR3X
1.
Internal Circuit
2. Marking on the body
Rectron Logo
BR3
Part No.
Plant - code
UL Logo
Year – code
(Y: Last digit of year &
A:2010, B:2011……)
VXXX
Week – code
(WW:01~52)
3. Items marked on the inner box and carton
3.1 On the box (for –B)
CUSTOMER
TYPE
LOT NO.
QUANTITY
Q.A.
DATE
3.2 On the carton
CUSTOMER
TYPE
QUANTITY
LOT NO.
REMARK
PACKAGING OF DIODE AND BRIDGE RECTIFIERS
BULK PACK
PACKAGE
PACKING CODE
BR-3/-6
-B
EA PER BOX
200
INNER BOX SIZE
CARTON SIZE
(mm)
(mm)
206*208*55
450*220*255
EA PER CARTON
2,000
GROSS
WEIGHT(Kg)
7.50/8.50
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.
很抱歉,暂时无法提供与“BR36”相匹配的价格&库存,您可以联系我们找货
免费人工找货