KBL401
THRU
KBL410
SINGLE-PHASE GLASS PASSIVATED
SILICON BRIDGE RECTIFIER
VOLTAGE RANGE 50 to 1000 Volts CURRENT 4.0 Amperes
FEATURES
*
*
*
*
*
Silver-plated copper leads
Surge overload rating: 125 amperes peak
Low leakage
Mounting position: Any
Low forward voltage
KBL
.770(19.55)
.730(18.54)
.157(4.0)*45(
MECHANICAL DATA
* Epoxy: Device has UL flammability classification 94V-O
.587(14.9)
.547(13.9)
.825(16.3)
.605(15.3)
+ A C -
.750
MIN.
(19.0)
.052(1.3)DIA.
.048(1.2)TYP.
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
.210(5.33)
.190(4.83)
Ratings at 25 o C ambient temperature unless otherwise specified.
resistive or inductive load.
.237(6.0)
.217(5.5)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted)
SYMBOL
KBL401
KBL403
KBL404
KBL406
KBL408
KBL410
UNITS
Maximum Recurrent Peak Reverse Voltage
VRRM
50
100
200
400
600
800
1000
Volts
Maximum RMS Voltage
VRMS
35
70
140
280
420
560
700
Volts
VDC
50
100
200
400
600
800
1000
Volts
RATINGS
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
o
at T A = 50 C
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
KBL402
IO
4.0
Amps
I FSM
125
Amps
I T
65
A S
2
Current Squared Time
Typical Thermal Resistance (Note 1)
Operating and Storage Temperature Range
Rθ JC
22
Rθ JA
28
TJ, T STG
-55 to + 150
2
0
C/ W
0
C
ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted)
CHARACTERISTICS
Maximum Instantaneous Forward Voltage at 4.0A DC
Maximum DC Reverse Current
at Rated DC Blocking Voltage
@T A = 25o C
@T A = 150o C
SYMBOL
VF
IR
NOTES : 1. Thermal Resistance : Heat-sink case mounted or if PCB mounted.
2. " ROHS compliant"
3. Measureed at 1MHz and applied reverse voltage of 4.0 volts.
KBL401
KBL402
KBL403
KBL404
1.1
KBL406
KBL408
KBL410
UNITS
Volts
10
1000
uAmps
2020-04/10
REV:A
RATING AND CHARACTERISTICS CURVES (KBL401 THRU KBL410)
FIG.1-DERATING CURVE
OUTPUT RECTIFIED CURRENT
FLG.1-MAXIMUM FORWARD SUNRGE CURRENT
AVERAGE FORWARD OUTPUT CURRENT
AMPERES
PEAK FORWARD SURGE CURRENT
AMPERES
6.0
150
125
T J=25°C
1
10
5.0
4.0
3.0
2.0
1.0
50
0
100
NUMBER OF CYCLETS AT 60Hz
100
150
AMBIENT TEMPERATURE °C
FIG.4– TYPICAL REVERSE
CHARACTERISTICS
FIG.4-TYPICAL FORWARD CHARACTERISTICS
10
INSTANTANEOUS REVERSE CURRENT
MICROAMPERES
INSTANTANEOUS FORWARD CURRENT,(A)
10
1.0
0.1
T J=25°C
PULSE WIDTH:300us
0.01
0
0.2
0.4
0.6
0.8
1.0
1.2
1.4
1.6
1.8
INSTANTANEOUS FORWARD VOLTAGE,VOLTS
1.0
T J = 25°C
0.1
0.01
0
20
40
60
80
100
120
140
PERCENT OF RATED PEAK REVERSE VOLTAGE
" " " "" " "
Marking Description
Rectron Logo
KBL40X
VYWW
Year – code
(Y:Last digit of year)
+
AC
-
Week – code
WW:01~52
Part No.
Voltage-code
1-------50V
6-------600V
2-------100V
3-------200V
4-------400V
8-------800V
10-------1000V
PACKAGING OF DIODE AND BRIDGE RECTIFIERS
TUBE PACK
PACKAGE
KBL
PACKING CODE
-C
EA PER BOX
1,150
INNER BOX SIZE
CARTON SIZE
(mm)
(mm)
49*14.5*13.2
49.5*32.5*15.5
EA PER CARTON
2,300
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.
很抱歉,暂时无法提供与“KBL402”相匹配的价格&库存,您可以联系我们找货
免费人工找货