MSB301S
THRU
MSB307S
SINGLE-PHASE GLASS PASSIVATED
SILICON BRIDGE RECTIFIER
VOLTAGE RANGE 50 to 1000 Volts CURRENT 3.0 Ampere
FEATURES
* Good for automation insertion
*
*
*
*
Ideal for printed circuit board
Reliable low cost construction utilizing molded
Glass passivated device
Mounting position: Any
MSBS
MECHANICAL DATA
* UL listed the recognized component directory, file #E94233
* Epoxy: Device has UL flammability classification 94V-O
* Halogen-free
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
o
Ratings at 25 C ambient temperature unless otherwise specified.
-
+
~
~
resistive or inductive load.
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (At T A = 25oC unless otherwise noted)
RATINGS
SYMBOL
MSB301S MSB302S MSB303S MSB304S MSB305S MSB306S MSB307S UNITS
Maximum Recurrent Peak Reverse Voltage
VRRM
50
Maximum RMS Bridge Input Voltage
VRMS
Maximum DC Blocking Voltage
VDC
Maximum Average Forward Output Current at T C = 110 oC
100
200
400
600
35
70
140
280
420
50
100
200
400
600
800
1000
Volts
560
700
Volts
800
1000
Volts
IO
3.0
Amps
I FSM
100
Amps
I2t
41.5
A2/Sec
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Typical Current Squarad Time
R JA
25
R JL
15
T J, T STG
-55 to + 150
Typical Thermal Resistance (Note 2)
Operating and Storage Temperature Range
0
C/W
0
C
ELECTRICAL CHARACTERISTICS (At TA = 25 C unless otherwise noted)
o
SYMBOL
CHARACTERISTICS
Maximum Forward Voltage Drop per Bridge
VF
Element at 3.0A DC
o
Maximum Reverse Current at Rated
@T A = 25 C
DC Blocking Voltage per element
@T A = 125 o C
Note: 1.”Fully ROHS compliant”,”100% Sn plating(Pb-free).
2. Thermal Resistance: Mounted on PCB.
IR
MSB301S MSB302S MSB303S MSB304S MSB305S MSB306S MSB307S UNITS
1.1
Volts
1.0
μAmps
500
μ Amps
2016-08
REV:A
120
8.3mS Single Half Sine-Wave
JEDEC Method
100
80
60
40
20
0
0
10
20
40
60
100
INSTANTANEOUS FORWARD CURRENT, (A)
PEAK FORWARD SURGE CURRENT, (A)
RATING AND CHARACTERISTICS CURVES ( MSB301S THRU MSB307S )
10
1
0.1
0.01
T J = 25 OC
Pulse Width = 300mS
1% Duty Cycle
0
FIG. 1 - MAXIMUM NON-REPETITIVE
FORWARD SURGE CURRENT
100
10
4.0
TA = 125OC
1
O
TA = 25 C
0
20
40
60
80
0.5
1.0
1.5
2.0
2.5
INSTANTANEOUS FORWARD VOLTAGE, (V)
AVERAGE FORWARD CURRENT, (A)
INSTANTANEOUS REVERSE CURRENT, (uA)
NUMBER OF CYCLES AT 60Hz
100
120
140
FIG.2 TYPICAL INSTANTANEOUS
FORWARD CHARACTERISTICS
3.0
2.0
1.0
60 Hz RESISTIVE OR
INDUCTIVE LOAD
0
20
40
60
80
100
120
140 150
PERCENT RATED PEAK REVERSE VOLTAGE, (%)
CASE TEMPERATURE, ( OC)
FIG.3 TYPICAL REVERSE CHARACTERISTICS
FIG.4 TYPICAL FORWARD CURRENT
DERATING CURVE
REEL TAPING SPECIFICATIONS FOR
SURFACE MOUNT DEVICES - MSBS
1
Fig.: Configuration of MSBS REEL TAPING
ITEM
Carrier width
SYMBOL
A
SPECIFICATIONS (mm)
0.69 0.1
SPECIFICATIONS (inch)
0.272 0.004
Carrier length
B
7.60
0.1
0.299
0.004
Carrier depth
C
1.70
0.1
0.067
0.004
0.004
Sprocket hole
d
1.50
0.1
0.059
Reel outside diameter
D
330.0
2.0
12.992
0.079
Reel inner diameter
D1
16.4
2.0
0.646
0.079
Feed hole diameter
D2
13.0
0.2
0.512
0.008
Sprocket hole position
E
1.75
0.1
0.069
0.004
Punch hole position
F
7.5
0.1
0.295
0.004
Punch hole pitch
P
12.0
0.1
0.472
0.004
Sprocket hole pitch
P0
4.0
0.1
0.157
0.004
Embossment center
P1
2.0
0.1
0.079
0.004
Tape width
W
16.0
0.3
0.63
0.012
Reel width
W1
22.4
1.0
0.882
0.039
PACKAGING OF DIODE AND BRIDGE RECTIFIERS
REEL PACK
PACKAGE
MSBS
PACKING EA PER EA PER COMPONENT TAPE SPACE REEL DIA CARTON SIZE EA PER
GROSS
SPACE
INNER
REEL
CARTON
WEIGHT(Kg)
CODE
(mm)
(mm)
(mm)
(mm)
BOX
-T
3,000
3,000
9.5
52
330
360*355*360
24,000
9.0
Marking Description
-
+
Rectron Logo
3 A 7
Part No.
7 for all Voltage range
~ V Y WW H ~
Year – code:
(Y:Last digit of year&
A:2010, B:2011……)
Week – code:
(WW:01~52)
Halogen-free
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.
很抱歉,暂时无法提供与“MSB307S”相匹配的价格&库存,您可以联系我们找货
免费人工找货