MSB405S
FAST RECOVERY BRIDGE RECTIFIER
VOLTAGE RANGE 600 Volts CURRENT 4.0 Ampere
FEATURES
* Good for automation insertion
*
*
*
*
Ideal for printed circuit board
Reliable low cost construction utilizing molded
Glass passivated device
Mounting position: Any
MSBS
MECHANICAL DATA
* UL listed the recognized component directory, file #E94233
* Epoxy: Device has UL flammability classification 94V-O
* Halogen-free
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 o C ambient temperature unless otherwise specified.
-
+
~
~
resistive or inductive load.
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (At T A = 25oC unless otherwise noted)
SYMBOL
MSB405S
UNITS
VRRM
600
Volts
Maximum RMS Bridge Input Voltage
VRMS
420
Volts
Maximum DC Blocking Voltage
VDC
600
Volts
IO
4.0
Amps
I FSM
120
Amps
I2t
59.76
A 2S
RATINGS
Maximum Recurrent Peak Reverse Voltage
Maximum Average Forward Output Current at T C = 110 oC
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Typical Current Squared Time
R JA
55
R JL
15
T J, T STG
-55 to + 150
Typical Thermal Resistance (Note 2)
Operating and Storage Temperature Range
0
C/W
0
C
ELECTRICAL CHARACTERISTICS (At TA = 25 C unless otherwise noted)
o
SYMBOL
CHARACTERISTICS
Maximum Forward Voltage Drop per Bridge
VF
Element at 2.0A DC
o
Maximum Reverse Current at Rated
@T A = 25 C
DC Blocking Voltage per element
@T A = 150 o C
Maximum Reverse Recovery Time (Note 3)
Note: 1.”ROHS compliant”.
2. Thermal Resistance: Mounted on PCB.
3. Test Conditions: IF = 0.5A, IR = -1.0A, IRR = -0.25A.
IR
trr
MSB405S
UNITS
.90
Volts
2.0
μAmps
2.0
mAmps
500
nSec
2018-12
REV:O
120
8.3mS Single Half Sine-Wave
JEDEC Method
100
80
60
40
20
0
0
10
20
40
60
100
INSTANTANEOUS FORWARD CURRENT, (A)
PEAK FORWARD SURGE CURRENT, (A)
RATING AND CHARACTERISTICS CURVES ( MSB405S )
10
1
0.1
T J = 25 OC
Pulse Width = 300mS
1% Duty Cycle
0.01
0
NUMBER OF CYCLES AT 60Hz
1.5
2.0
2.5
4.0
10 6
AVERAGE FORWARD CURRENT, (A)
INSTANTANEOUS REVERSE CURRENT, (uA)
1.0
FIG.2 MAXIMUM INSTANTANEOUS
FORWARD CHARACTERIST
TICS
FIG. 1 - MAXIMUM NON-REPETITIVE
FORWARD SURGE CURRENT
10
0.5
INSTANTANEOUS FORWARD VOLTAGE, (V)
3
TA = 150OC
1
O
TA = 25 C
0
20
40
60
80
100
120
140
PERCENT RATED PEAK REVERSE VOLTAGE, (%)
FIG.3 MAXIMUM REVERSE CHARACTERISTIICS
3.0
2.0
1.0
60 Hz RESISTIVE OR
INDUCTIVE LOAD
0
20
40
60
80
100
120
140 150
CASE TEMPERATURE, ( OC)
FIIG.4 TYPICAL FORWARD CURRENT
DER
RATING CURVE
REEL TAPING SPECIFICATIONS FOR
SURFACE MOUNT DEVICES - MSBS
1
Fig.: Configuration of MSBS REEL TAPING
ITEM
Carrier width
SYMBOL
A
SPECIFICATIONS (mm)
0.69 0.1
SPECIFICATIONS (inch)
0.272 0.004
Carrier length
B
7.60
0.1
0.299
0.004
Carrier depth
C
1.70
0.1
0.067
0.004
Sprocket hole
d
1.50
0.1
0.059
0.004
Reel outside diameter
D
330.0
2.0
12.992
0.079
Reel inner diameter
D1
16.4
2.0
0.646
0.079
Feed hole diameter
D2
13.0
0.2
0.512
0.008
Sprocket hole position
E
1.75
0.1
0.069
0.004
Punch hole position
F
7.5
0.1
0.295
0.004
Punch hole pitch
P
12.0
0.1
0.472
0.004
Sprocket hole pitch
P0
4.0
0.1
0.157
0.004
Embossment center
P1
2.0
0.1
0.079
0.004
Tape width
W
16.0
0.3
0.63
0.012
Reel width
W1
22.4
1.0
0.882
0.039
PACKAGING OF DIODE AND BRIDGE RECTIFIERS
REEL PACK
PACKAGE
MSBS
PACKING EA PER EA PER COMPONENT TAPE SPACE REEL DIA CARTON SIZE EA PER
GROSS
SPACE
INNER
REEL
CARTON
WEIGHT(Kg)
CODE
(mm)
(mm)
(mm)
(mm)
BOX
-T
3,000
3,000
9.5
52
330
360*355*360
24,000
9.0
Marking Description
-
+
Rectron Logo
4 A 5
Part No.
5------600V
~ V Y WW H ~
Year – code:
(Y:Last digit of year&
A:2010, B:2011……)
Week – code:
(WW:01~52)
Halogen-free
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.
很抱歉,暂时无法提供与“MSB405S”相匹配的价格&库存,您可以联系我们找货
免费人工找货