RB151
THRU
RB157
SINGLE-PHASE GLASS PASSIVATED
SILICON BRIDGE RECTIFIER
VOLTAGE RANGE 50 to 1000 Volts CURRENT 1.5 Amperes
FEATURES
* High reverse voltage to 1000V
* Surge overload rating to 40 amperes peak
* Good for printed circuit board assembly
RB-15
MECHANICAL DATA
.360 (9.1)
* Epoxy: Device has UL flammability classification 94V-O
* UL listed the recognized component directory,file #E94233
* Lead: Silver-plated copper leads
.340 (8.6)
.217 (5.5)
.130 (3.3)
1.2
(30.5)
MIN.
~~-
+
.032 (0.8)
POS.
LEAD
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
+
~
~
Ratings at 25 o C ambient temperature unless otherwise specified.
1.0
(25.4)
MIN.
.028 (0.7)
+
~
~
.220 (5.6)
-
resistive or inductive load.
.180 (4.6)
.220 (5.6)
-
.180 (4.6)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted)
SYMBOL
RB151
RB152
Maximum Recurrent Peak Reverse Voltage
VRRM
50
100
200
400
600
800
1000
Volts
Maximum RMS Voltage
VRMS
35
70
140
280
420
560
700
Volts
VDC
50
100
200
400
600
800
1000
RATINGS
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
at T A=25 OC
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Typical Current Squarad Time
Typical Thermal Resistance (Note 1)
Operating Temperature Range
Storage Temperature Range
RB153
RB154
RB155
RB156
RB157
UNITS
Volts
IO
1.5
Amps
I FSM
40
Amps
I2t
6.64
A 2 /Sec
R JA
36
R JC
TJ
12
-55 to + 150
T STG
-55 to + 150
0
C/W
0
C
0
C
ELECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted)
CHARACTERISTICS
SYMBOL
Maximum Instantaneous Forward Voltage at 1.0A DC
Maximum Average Reverse Current
@T A = 25 o C
at Rated DC Blocking Voltage
@T A = 150 o C
NOTES : 1. Thermal Resistance : Heat-sink case mounted.
2. "ROHS compliant".
VF
IR
RB151
RB152
RB153
RB154
RB155
RB156
RB157
UNITS
1.0
Volts
1.0
uA
1.0
mA
2020-08
REV:E
INSTANTANEOUS REVERSE CURRENT, (uA)
RATING AND CHARACTERISTICS CURVES ( RB151 THRU RB157 )
AVERAGE FORWARD CURRENT, (A)
1.8
1.5
1.2
0.9
0.6
Single Phase Half Wave
60Hz Inductive or
Resistive Load
0.375" (9.5mm) Lead Length
0.3
0
0
50
100
150
10000
1000
TA = 150 OC
10
1.0
T A = 25 OC
0.1
0
20
40
60
80
100
120
140
O
AMBIENT TEMPERATURE, ( C)
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
FIG.2 MAXIMUM REVERSE
CHARACTERISTICS
50
PEAK FORWARD SURGE CURRENT, (A)
INSTANTANEOUS REVERSE CURRENT, (A)
FIG.1 TYPICAL FORWARD CURRENT
DERATING CURVE
10
1.0
0.1
TJ = 25 OC
Pulse width=300 S
1% Duty Cycle
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
4.5
INSTANTANEOUS FORWARD VOLTAGE, (V)
FIG.3 MAXIMUM INSTANTANEOUS FORWARD
CHARACTERISTICS
60
8.3mS Single Half Sine-Wave
JEDEC Method
50
40
30
20
10
0
1
2
5
10
20
50
100
NUMBER OF CYCLES AT 60Hz
FIG.4 MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
Marking Description
+
Rectron Logo
Part No.
UL Logo
RB15X
V Y WW
Year – code:
(Y:Last digit of year &
A:2010,B:2011......)
Week – code:
(WW:01~52)
Voltage-code
1-------50V
2-------100V
3-------200V
4-------400V
5-------600V
6-------800V
7-----1000V
PACKAGING OF DIODE AND BRIDGE RECTIFIERS
BULK PACK
PACKAGE
PACKING CODE
RB-15
-B
EA PER BOX
1,000
INNER BOX SIZE
CARTON SIZE
(mm)
(mm)
165*252*59
347*320*271
EA PER CARTON
10,000
GROSS
WEIGHT(Kg)
11.6
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.
很抱歉,暂时无法提供与“RB155”相匹配的价格&库存,您可以联系我们找货