RBU2501M
THRU
RBU2507M
SINGLE-PHASE GLASS PASSIVATED
SILICON BRIDGE RECTIFIER
VOLTAGE RANGE 50 to 1000 Volts CURRENT 25 Amper es
FEATURES
Low leakage
Low forward voltage
Surge overload rating : 350 amperes peak
Mounting position: Any
Ideal for printed circuit boards
High forward surge current capability
RBU
MECHANICAL DATA
.880 (22.3)
.140 (3.56)
.130 (3.30)
.860 (21.8)
* Epoxy: Device has UL flammability classification 94V-O
Top Side
.088 (2.2 3)
.068 (1.7 2)
.160 (4.1)
.140 (3.5)
.740 (18.8)
.720 (18.3)
*
*
*
*
*
*
.085 (2.16)
.075 (1.90)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 o C ambient temperature unless otherwise specified.
resistive or inductive load.
.210 (5.33)
.190 (4.83)
.080 (2.03)
.065 (1.65)
.050 (1.27)
.040 (1.02)
.724 (18.4)
.705 (17.9)
.100 (2.54)
.085 (2.16)
.026 (0.67)
.020 (0.52)
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted)
RATINGS
SYMBOL
RBU2501M RBU2502M RBU2503M RBU2504M RBU2505M RBU2506M RBU2507M
UNITS
Maximum Recurrent Peak Reverse Voltage
VRRM
50
100
200
400
600
800
1000
Maximum RMS Voltage
VRMS
35
70
140
280
420
560
700
Volts
VDC
50
100
200
400
600
800
1000
Volts
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
o
at T C = 100 C (Note 4)
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
Typical Current Squared Time
Isolation Voltage of case
Typical Thermal Resistance (Note 1)
Operating and Storage Temperature Range
Volts
IO
25.0
Amps
I FSM
350
Amps
I 2t
508
2
A /S
V AC
VISO
2500
R θJC
2.2
R θ JA
22
T J, T STG
-55 to + 150
0
C/ W
0
C
ELECTRICAL CHARACTERISTICS(@TA=25 C unless otherwise noted)
O
CHARACTERISTICS
Maximum Instantaneous Forward Voltage at 12.5A DC
Maximum DC Reverse Current
at Rated DC Blocking Voltage
@T A = 25 o C
@T A =150 o C
SYMBOL
RBU2501M RBU2502M RBU2503M RBU2504M RBU2505M RBU2506M RBU2507M
VF
IR
NOTES : 1. Thermal Resistance : Heat-sink case mounted or if PCB mounted.
2. "Fully ROHS compliant", "100% Sn plating (Pb-free)".
3.Available in Halogen-free epoxy by adding suffix -HF after the part nbr.
4. Heat Sink Temperature.
UNITS
1.1
Volts
5.0
uAmps
2.0
mAmps
2018-10/14
REV: B
200
100
PEAK FORWARD SURGE CURRENT, (A)
INSTANTANEOUS FORWARD CURRENT, (A)
RATING AND CHARACTERISTICS CURVES ( RBU2501M THRU RBU2507M)
TJ = 25 OC
30
10
3
1
0.3
0.1
Pulse Width=300uS
1% Duty Cycle
0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
500
400
200
100
50
10
1
5
INSTANTANEOUS FORWARD VOLTAGE, (V)
FIG.1 MAXIMUM INSTANTANEOUS FORWARD
CHARACTERISTICS
1000
600
400
200
100
10
4
2
1
1
2
4
10
20
40
With Heatsink
25.0
20.0
15.0
Single Phase
Half Wave 60Hz
Resistive or
Inductive Load
10.0
100
0
50
25
75
100
10
TA = 25 OC
20
40
150
CASE TEMPERATURE, ( C)
1000
0
125
FIG.4 TYPICAL FORWARD CURRENT
DERATING CURVE
FIG.3 TYPICAL JUNCTION CAPACITANCE
0.1
100
O
REVERSE VOLTAGE, (V)
1.0
100
30.0
5.0
0.4
50
FIG.2 MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
AVERAGE FORWARD CURRENT, (A)
TJ = 25 OC
INSTANTANEOUS REVERSE CURRENT, ( A)
JUNCTION CAPACITANCE, (pF)
2000
10
NUMBER OF CYCLES AT 60Hz
60
80
100
120
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
FIG.5 MAXIMUM REVERSE
CHARACTERISTICS
140
175
Marking Description
Rectron Logo
RBU250XM
Part No.
Voltage-code
UL Logo
V Y WW
Year – code:
(Y:Last digit of year
A:2010, B: 2011...)
Week – code:
(WW:01~52)
1-------50V
5-------600V
2-------100V
3-------200V
4-------400V
6-------800V
7-------1000V
PACKAGING OF DIODE AND BRIDGE RECTIFIERS
TUBE PACK
PACKAGE
PACKING CODE
EA PER BOX
INNER BOX SIZE
CARTON SIZE
(mm)
(mm)
RBU
-C
1,000
490*135*110
510*293*131
EA PER CARTON
WEIGHT(Kg)
2,000
13.62
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.
很抱歉,暂时无法提供与“RBU2504M”相匹配的价格&库存,您可以联系我们找货
免费人工找货