RS401L
THRU
RS407L
SINGLE-PHASE GLASS PASSIVATED
SILICON BRIDGE RECTIFIER
VOLTAGE RANGE 50 to 1000 Volts CURRENT 4.0 Amperes
FEATURES
*
*
*
*
*
Tin-plated copper leads
Surge overload rating: 150 amperes peak
Low leakage
Mounting position: Any
Low forward voltage
RS-4L
.768 (19.5)
.728 (18.5)
MECHANICAL DATA
.580(14.7)
* Epoxy: Device has UL flammability classification 94V-O
* Epoxy: UL listed the recognized component,file #94233
.640 (16.3)
.600 (15.2)
.540 (13.7)
DIA.
.052 (1.3)
.048 (1.2)
.669
(17.0)
MIN.
.220 (5.6)
.083 (2.1)
.180 (4.6)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
.237 (6.0)
o
Ratings at 25 C ambient temperature unless otherwise specified.
.217(5.5)
resistive or inductive load.
Dimensions in inches and (millimeters)
MAXIMUM RATINGS (@ TA=25 OC unless otherwise noted)
SYMBOL
RS401L
RS402L
RS403L
RS404L
RS405L
RS406L
RS407L
UNITS
Maximum Recurrent Peak Reverse Voltage
VRRM
50
100
200
400
600
800
1000
Volts
Maximum RMS Voltage
VRMS
35
70
140
280
420
560
700
Volts
VDC
50
100
200
400
600
800
1000
Volts
RATINGS
Maximum DC Blocking Voltage
Maximum Average Forward Rectified Current
o
at T A = 50 C
IO
4.0
Amps
150
Amps
Peak Forward Surge Current 8.3 ms single half sine-wave
superimposed on rated load (JEDEC method)
I FSM
Typical Current Squarad Time
I t
2
93.37
A2Sec
Volts
Insulation voltage
Typical Thermal Resistance (Note 1)
Typical Junction Capacitance (Note 3)
Operating and Storage Temperature Range
Viso
3000
R θ JC
10
R θ JA
28
CJ
40
T J, T STG
0
C/ W
pF
0
-55 to + 150
C
ELECTRICAL CHARACTERISTICS (@TA=25 C unless otherwise noted)
O
CHARACTERISTICS
Maximum Instantaneous Forward Voltage at 4.0A DC
Maximum DC Reverse Current
at Rated DC Blocking Voltage
@T A = 25o C
@T A = 150o C
SYMBOL
VF
IR
NOTES : 1. Thermal Resistance : Heat-sink case mounted or if PCB mounted.
2. " ROHS compliant".
3. Measureed at 1MHz and applied reverse voltage of 4.0 volts.
RS401L
RS402L
RS403L
RS404L
1.05
RS405L
RS406L
RS407L
UNITS
Volts
2.0
500
uAmps
2021-07
REV: H
AVERAGE FORWARD CURRENT, (A)
4.0
3.2
2.4
1.6
Single Phase Half Wave
60 Hz Inductive or
Resistive Load
0.8
0
0
50
100
150
INSTANTANEOUS FORWARD CURRENT, (A)
RATING AND CHARACTERISTICS CURVES (RS401L THRU RS407L)
40
10
4
1
0.4
0.1
T A = 25 OC
Pulse Width = 300mS
1% Duty Cycle
0
O
AMBIENT TEMPERATURE, ( C)
PEAK FORWARD SURGE CURRENT, (A)
INSTANTANEOUS REVERSE CURRENT, (μA)
1000
100
TA = 150 OC
10
1.0
TA = 25 OC
0
20
40
60
80
100
1.0
1.5
2.0
2.5
3.0
3.5
FIG.2 MAXIMUM INSTANTANEOUS
FORWARD CHARACTERISTICS
FIG.1 TYPICAL FORWARD CURRENT
DERATING CURVE
0.1
0.5
INSTANTANEOUS FORWARD VOLTAGE, (V)
120
140
PERCENT RATED PEAK REVERSE VOLTAGE, (%)
FIG.3 MAXIMUM REVERSE CHARACTERISTICS
180
8.3mS Single Half Sine-Wave
JEDEC Method
150
120
90
60
30
0
1
2
5
10
20
50
100
NUMBER OF CYCLES AT 60Hz
FIG.4 MAXIMUM NON-REPETITIVE FORWARD
SURGE CURRENT
" " " "" " "
Marking Description
Rectron Logo
RS407L
Part No.
Voltage-code
UL Logo
Year – code:
(Y: Last digit of year &
A:2010,B:2011......) +
V Y WW
AC
-
Week – code:
(WW:01~52)
7---for all Voltage range
PACKAGING OF DIODE AND BRIDGE RECTIFIERS
TUBE PACK
PACKAGE
PACKING CODE
RS-4L
-C
EA PER BOX
1,012
INNER BOX SIZE
CARTON SIZE
(mm)
(mm)
491*145*133
495*323*157
EA PER CARTON
WEIGHT(Kg)
2,024
14.5
BULK PACK
PACKAGE
PACKING CODE
RS-4L
-B
EA PER BOX
500
INNER BOX SIZE
CARTON SIZE
(mm)
(mm)
225*227*45
475*245*168
EA PER CARTON
3,000
GROSS
WEIGHT(Kg)
15.0
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product
specification herein, to make corrections, modifications, enhancements or other
changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information
contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or
use of any product or circuit.
Rectron products are not designed, intended or authorized for use in medical,
life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in
such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.
很抱歉,暂时无法提供与“RS401L”相匹配的价格&库存,您可以联系我们找货