SURFACE MOUNT HIGH EFFICIENCY RECTIFIER
VOLTAGE RANGE 50 to 600 Volts CURRENT 1.0 Ampere
SH1L THRU SH6L
FEATURES
* * * * * * *
Low power loss, high efficiency Low leakage Low forward voltage High current capability High speed switching High surge capability High reliability
.114 (2.9) .106 (2.7) .035 (0.90) .028 (0.70)
SOD-123FL
MECHANICAL DATA
* Epoxy: Device has UL flammability classification 94V-O * Mounting position: Any * Weight: 0.016 g ram
.077 (1.95) .069 (1.75)
.008 (0.20)
.039 (1.00) .035 (0.90)
.150 (3.8) .142 (3.6) .052 (1.32) .050 (1.28)
MAXIMUM RATINGS AND ELECTRICAL CHARACTERISTICS
Ratings at 25 o C ambient temperature unless otherwise specified. Single phase, half wave, 60 Hz, resistive or inductive load. For capacitive load, derate current by 20%.
.033 (0.85) .030 (0.75) .044 (1.12) .043 (1.08)
.033 (0.85) .030 (0.75)
Dimensions in inches and (millimeters) MAXIMUM RAT INGS (@ TA=25 OC unless otherwise noted) R ATINGS Maximum Recurrent Peak Reverse Voltage Maximum RMS Voltage Maximum DC Blocking Voltage Maximum Average Forward Rectified Current at T A = 5 5 OC Peak Forward Surge Current 8.3 ms single half sine-wave superimposed on rated load (JEDEC method) Typical Thermal Resistance (Note 1) Typical Thermal Resistance (Note 1) Typical Junction Capacitance (Note 2) Operating Te mperature Ran g e Storage Temperature R an g e SYMBOL VRRM VRMS VDC IO I FSM RqJA RqJL CJ TJ T STG 15 150 -55 to + 150
SH1L SH2L SH3L SH4L SH5L SH6L
UNITS Volts Volts Volts Amps Amps
0 0
50 35 50
100 70 100
200 140 200 1.0 20 130 30
300 210 300
400 280 400
600 420 600
C/W C/W pF
0 0
12
C C
E LECTRICAL CHARACTERISTICS (@TA=25 OC unless otherwise noted) CHARACTERISTICS Maximum Instantaneous Forward Voltage at 1.0A DC Maximum Average Reverse Current at Rated DC Blocking Voltage @T A = 2 5 o C @T A = 1 00 o C SYMBOL VF IR trr 50
SH1L SH2L SH3L SH4L SH5L SH6L
UNITS Volts mA mA
1.0 5 100
1.3
1.7
Maximum Reverse Recovery Time (Note 4) NOTES : 1 . 2. 3. 4.
75
nSec 2006-12
Thermal Resistance :Mounted on PCB. Measured at 1 MHz and applied reverse voltage of 4.0 volts. "Fully ROHS compliant","100% Sn plating (Pb-free)". Test Conditions: I F= 0.5A, I R= -1.0A, I RR= -0.25A.
RATING AND CHARACTERISTICS CURVES ( SH1L THRU SH6L )
50 W NONINDUCTIVE 10 W NONINDUCTIVE +0.5A
trr
(+) 25 Vdc (approx) (-)
D.U.T
(-)
PULSE GENERATOR (NOTE 2)
0 -0.25A
1 NONINDUCTIVE
OSCILLOSCOPE (NOTE 1)
(+)
NOTES: 1 Rise Time = 7ns max. Input Impedance = 1 megohm. 22pF. 2. Rise Time = 10ns max. Source Impedance = 50 ohms.
-1.0A
1cm
SET TIME BASE FOR 20/1 ns/cm
FIG.1 TEST CIRCUIT DIAGRAM AND REVERSE RECOVERY TIME CHARACTERISTIC
INSTANTANEOUS REVERSE CURRENT, (uA) 1.0
AVERAGE FORWARD CURRENT, (A)
1000
0.8 0.6 0.4 0.2 0
Single Phase Half Wave 60Hz Resistive or Inductive Load
100
TA = 100 OC T A = 7 5 OC
10
T A = 2 5 OC
1.0
0
25
50
75
100
125
150
175
0.1
0
20
40
60
80
100
120
140
AMBIENT TEMPERATURE, (OC)
PERCENT OF RATED PEAK REVERSE VOLTAGE, (%)
FIG.2 TYPICAL FORWARD CURRENT DERATING CURVE
FIG.3 TYPICAL REVERSE CHARACTERISTICS
RATING AND CHARACTERISTICS CURVES ( SH1L THRU SH6L )
INSTANTANEOUS FORWARD CURRENT, (A)
PEAK FORWARD SURGE CURRENT, (A)
20 10 3.0 1.0 0.3 0.1 0.03 0.01 0
20 10
T J = 2 5 OC SH1L~SH3L SH4L~SH5L SH6L
8.3ms Single Half Sine-Wave (JEDED Method)
5 3 2 1
Pulse Width=300uS 1% Duty Cycle
0.5
1.0
1.5
2.0
2.5
3.0
3.5
1
5
10
50
100
INSTANTANEOUS FORWARD VOLTAGE, (V)
NUMBER OF CYCLES AT 60Hz
FIG.4 TYPICAL INSTANTANEOUS FORWARD CHARACTERISTICS
200
JUNCTION CAPACITANCE, (pF)
FIG.5 MAXIMUM NON-REPETITIVE FORWARD SURGE CURRENT
100 60 40 20 10 6 4 2 1 0.1 0.2 0.4 1.0 2 4 10
SH6L
T J = 2 5 OC
SH1L~SH5L
20
40
100
REVERSE VOLTAGE, (V)
FIG.6 TYPICAL JUNCTION CAPACITANCE
Mounting Pad Layout
.052 MIN. (1.32 MIN.)
.033 MIN. (0.85 MIN.)
.044 MIN. (1.12 MIN.) 0.165
.033 MIN. (0.85 MIN.)
(4.19) REF
Dimensions in inches and (millimeters)
DISCLAIMER NOTICE
Rectron Inc reserves the right to make changes without notice to any product specification herein, to make corrections, modifications, enhancements or other changes. Rectron Inc or anyone on its behalf assumes no responsibility or liability for any errors or inaccuracies. Data sheet specifications and its information contained are intended to provide a product description only. "Typical" parameters which may be included on RECTRON data sheets and/ or specifications can and do vary in different applications and actual performance may vary over time. Rectron Inc does not assume any liability arising out of the application or use of any product or circuit. Rectron products are not designed, intended or authorized for use in medical, life-saving implant or other applications intended for life-sustaining or other related applications where a failure or malfunction of component or circuitry may directly or indirectly cause injury or threaten a life without expressed written approval of Rectron Inc. Customers using or selling Rectron components for use in such applications do so at their own risk and shall agree to fully indemnify Rectron Inc and its subsidiaries harmless against all claims, damages and expenditures.