DATASHEET
X9118
FN8161
Rev 5.00
April 9, 2014
Dual Supply/Low Power/1024-Tap/2-Wire Bus Single Digitally-Controlled
(XDCP™) Potentiometer
The X9118 is a single digitally controlled potentiometer
(XDCP) on a monolithic CMOS integrated circuit.
The digital controlled potentiometer is implemented using
1023 resistive elements in a series array. Between each
element are tap points connected to the wiper terminal
through switches. The position of the wiper on the array is
controlled by the user through the 2-wire bus interface. The
potentiometer has associated with it a volatile Wiper Counter
Register (WCR) and a four non-volatile Data Registers that
can be directly written to and read by the user. The contents
of the WCR controls the position of the wiper on the resistor
array though the switches. Power-up recalls the contents of
the default data register (DR0) to the WCR.
The XDCP can be used as a three-terminal potentiometer or
as a two terminal variable resistors in a wide variety of
applications including control, parameter adjustments, and
signal processing.
Features
• 1024 resistor taps – 10-bit resolution
• 2-wire serial interface for write, read and transfer
operations of the potentiometer
• Wiper resistance, 40 typical @ 5V
• Four non-volatile data registers for each potentiometer
• Non-volatile storage of multiple wiper positions
• Power on recall: Loads saved wiper position on power-up
• Standby current < 15µA Max
• System VCC: 2.7V to 5.5V operation
• Analog V+/V-: -5V to +5V
• 100k end-to-end resistance
• Endurance: 100,000 data changes per bit per register
• 100 years data retention
• 14 Ld TSSOP
• Low power CMOS
• Pb-free (RoHS compliant)
Ordering Information
PART NUMBER
(Notes 1, 2)
PART
MARKING
VCC LIMITS
(V)
POTENTIOMETER
ORGANIZATION
(kΩ)
TEMP
RANGE
(°C)
PACKAGE
(Pb-free)
PKG.
DWG. #
X9118TV14IZ
X9118 TVZI
5 ±10%
100
-40 to +85
14 Ld TSSOP
M14.173
X9118TV14IZ-2.7
X9118 TVZG
2.7 to 5.5
100
-40 to +85
14 Ld TSSOP
M14.173
X9118TV14Z
X9118 TVZ
5 ±10%
100
0 to +70
14 Ld TSSOP
M14.173
X9118TV14Z-2.7
X9118 TVZF
2.7 to 5.5
100
0 to +70
14 Ld TSSOP
M14.173
NOTES:
1. These Intersil Pb-free plastic packaged products employ special Pb-free material sets, molding compounds/die attach materials, and 100% matte
tin plate plus anneal (e3 termination finish, which is RoHS compliant and compatible with both SnPb and Pb-free soldering operations). Intersil
Pb-free products are MSL classified at Pb-free peak reflow temperatures that meet or exceed the Pb-free requirements of IPC/JEDEC J STD020.
2. For Moisture Sensitivity Level (MSL), please see product information page for X9118. For more information on MSL, please see tech brief TB363.
FN8161 Rev 5.00
April 9, 2014
Page 1 of 17
X9118
Functional Diagram
VCC
2-WIRE
BUS
INTERFACE
ADDRESS
DATA
STATUS
BUS
INTERFACE
AND
CONTROL
RH
WRITE
READ
TRANSFER
POWER ON RECALL
CONTROL
VSS
100k
1024-TAPS
POT
WIPER COUNTER
REGISTER (WCR)
DATA REGISTERS
(DR0-DR3)
NC
NC
V+
WIPER
RL
RW
V-
Detailed Functional Diagram
VCC
V+
POWER ON
RECALL
DR0
SCL
SDA
A1
A0
INTERFACE
AND
CONTROL
CIRCUITRY
DR1
DATA
DR2
DR3
RH
WIPER
COUNTER
REGISTER
(WCR)
100K
1024-TAPS
RL
CONTROL
RW
WP
VSS
V-
Circuit Level Applications
System Level Applications
• Vary the gain of a voltage amplifier
• Adjust the contrast in LCD displays
• Provide programmable DC reference voltages for comparators
and detectors
• Control the power level of LED transmitters in
communication systems
• Control the volume in audio circuits
• Set and regulate the DC biasing point in an RF power
amplifier in wireless systems
• Trim out the offset voltage error in a voltage amplifier circuit
• Set the output voltage of a voltage regulator
• Control the gain in audio and home entertainment systems
• Trim the resistance in Wheatstone bridge circuits
• Provide the variable DC bias for tuners in RF wireless
systems
• Control the gain, characteristic frequency and Q-factor in filter
circuits
• Set the operating points in temperature control systems
• Set the scale factor and zero point in sensor signal conditioning
circuits
• Control the operating point for sensors in industrial systems
• Trim offset and gain errors in artificial intelligent systems
• Vary the frequency and duty cycle of timer ICs
• Vary the DC biasing of a pin diode attenuator in RF circuits
• Provide a control variable (I, V, or R) in feedback circuits
FN8161 Rev 5.00
April 9, 2014
Page 2 of 17
X9118
DEVICE ADDRESS (A1–A0)
Pinout
X9118
(14 LD TSSOP)
TOP VIEW
V+
NC
1
14
VCC
2
13
RL
A0
3
12
RH
SCL
4
11
RW
NC
A1
WP
5
10
SDA
6
VSS
7
9
8
V-
The address inputs are used to set the least significant 2 bits of
the 8-bit slave address. A match in the slave address serial
data stream must be made with the Address input, in order to
initiate communication with the X9118. A maximum of 4 XDCP
devices may occupy the 2-wire serial bus.
HARDWARE WRITE PROTECT INPUT (WP)
The WP pin when LOW prevents nonvolatile writes to the Data
Registers.
Potentiometer Pins
RH, RL
Pin Assignments
FUNCTION
The RH and RL pins are equivalent to the terminal connections
on a mechanical potentiometer.
PIN #
PIN NAME
1
V+
Analog Supply Voltage
RW
2, 10
NC
No Connect
3
A0
Device Address for 2-wire bus
The wiper pin is equivalent to the wiper terminal of a
mechanical potentiometer.
4
SCL
Serial Clock for 2-wire bus
Bias Supply Pins
5
WP
Hardware Write Protect
6
SDA
Serial Data Input/Output for 2-wire bus
SYSTEM SUPPLY VOLTAGE (VCC) AND SUPPLY GROUND
(VSS)
7
VSS
System Ground
8
V-
Analog Supply Voltage
9
A1
Device Address for 2-wire bus
11
RW
Wiper terminal of the Potentiometer
12
RH
High terminal of the Potentiometer
13
RL
Low terminal of the Potentiometer
14
VCC
System Supply Voltage
Pin Descriptions
Bus Interface Pins
SERIAL DATA INPUT/OUTPUT (SDA)
The SDA is a bi-directional serial data input/output pin for a
2-wire slave device and is used to transfer data into and out of
the device. It receives device address, opcode, wiper register
address and data sent from a 2-wire master at the rising edge
of the serial clock SCL, and it shifts out data after each falling
edge of the serial clock SCL.
It is an open drain output and may be wire-ORed with any
number of open drain or open collector outputs. An open drain
output requires the use of a pull-up resistor. The user must
account for the capacitance on the bus line and the desired
rise and fall times when selecting a pull-up resistor. 2kΩ to
2.5kΩ are typical values when using the maximum clock
frequency.
The VCC pin is the system or digital supply voltage. The VSS
pin is the system ground.
ANALOG SUPPLY VOLTAGES (V+ AND V-)
These supplies are the analog voltage supplies for the
potentiometer. The V+ supply is tied to the wiper switches
while the V- supply is used to bias switches and the internal P+
substrate of the integrated circuit. Both of these supplies set
the voltage limits of the potentiometer.
Other Pins
NO CONNECT
No connect pins should be left open. These pins are used for
Intersil manufacturing and testing purposes.
Principles of Operation
The X9118 is an integrated microcircuit incorporating a resistor
array and its registers and counters and the serial interface
logic providing direct communication between the host and the
digitally controlled potentiometer. This section provides a
detailed description of the following:
• Resistor Array Description
• Serial Interface Description
• Instruction and Register Description
SERIAL CLOCK (SCL)
This input is used by 2-wire master to supply 2-wire serial clock
to the X9118.
FN8161 Rev 5.00
April 9, 2014
Page 3 of 17
X9118
SERIAL DATA PATH
RH
SERIAL
BUS
INPUT
FROM INTERFACE
CIRCUITRY
REGISTER 0
(DR0)
REGISTER 1
(DR1)
10
REGISTER 2
(DR2)
10
REGISTER 3
(DR3)
PARALLEL
BUS
INPUT
WIPER
COUNTER
REGISTER
(WCR)
C
O
U
N
T
E
R
D
E
C
O
D
E
If WCR = 000[HEX] then RW = RL
If WCR = 3FF[HEX] then RW = RH
RL
RW
FIGURE 1. DETAILED POTENTIOMETER BLOCK DIAGRAM
Resistor Array Description
CLOCK AND DATA CONVENTIONS
The X9118 is comprised of a resistor array. The array contains
1023, in effect, discrete resistive segments that are connected
in series (see Figure 1). The physical ends of each array are
equivalent to the fixed terminals of a mechanical potentiometer
(RH and RL inputs).
Data states on the SDA line can change only during SCL LOW
periods. The SDA state changes during SCL HIGH are reserved
for indicating start and stop conditions,
see Figure 3.
At both ends of each array and between each resistor segment
is a CMOS switch (transmission gate) connected to the wiper
(RW) output. Within each individual array only one switch may
be turned on at a time. These switches are controlled by the
wiper counter register (WCR). The 10 bits of the WCR
(WCR[9:0]) are decoded to select, and enable, one of 1024
switches.
All commands to the X9118 are preceded by the start
condition, which is a HIGH-to-LOW transition of SDA while
SCL is HIGH. The X9118 continuously monitors the SDA and
SCL lines for the start condition and will not respond to any
command until this condition is met, see Figure 3.
The WCR may be written directly. The Data Registers and the
WCR can be read and written by the host system.
START CONDITION
STOP CONDITION
All communications must be terminated by a stop condition,
which is a LOW-to-HIGH transition of SDA while SCL is HIGH,
see Figure 3.
Serial Interface Description
ACKNOWLEDGE
SERIAL INTERFACE – 2-WIRE
Acknowledge is a software convention used to provide a
positive handshake between the master and slave devices on
the bus to indicate the successful receipt of data. The
transmitting device, either the master or the slave, will release
the SDA bus after transmitting 8 bits. The master generates a
ninth clock cycle and during this period the receiver pulls the
SDA line LOW to acknowledge that it successfully received the
eight bits of data.
The X9118 supports a bi-directional bus oriented protocol. The
protocol defines any device that sends data onto the bus as a
transmitter and the receiving device as the receiver. The
device controlling the transfer is a master and the device being
controlled is the slave. The master will always initiate data
transfers and provide the clock for both transmit and receive
operations. Therefore, the X9118 will be considered a slave
device in all applications.
FN8161 Rev 5.00
April 9, 2014
The X9118 will respond with an acknowledge after recognition
of a start condition and its slave address and once again after
successful receipt of the command byte. If the command is
followed by a data byte, the X9118 will respond with a final
acknowledge, see Figure 2.
Page 4 of 17
X9118
SCL FROM
MASTER
1
8
9
DATA OUTPUT
FROM TRANSMITTER
DATA OUTPUT
FROM RECEIVER
ACKNOWLEDGE
START
FIGURE 2. ACKNOWLEDGE RESPONSE FROM RECEIVER
ACKNOWLEDGE POLLING
INSTRUCTION AND REGISTER DESCRIPTION
The disabling of the inputs during the internal nonvolatile write
operation, can be used to take advantage of the typical 5ms
EEPROM write cycle time. Once the stop condition is issued to
indicate the end of the nonvolatile write command the X9118
initiates the internal write cycle. The ACK polling, Flow 1, can be
initiated immediately. This involves issuing the start condition
followed by the device slave address. If the X9118 is still busy with
the write operation no ACK will be returned. If the X9118 has
completed the write operation an ACK will be returned and the
master can then proceed with the next operation.
Device Addressing: Identification Byte (ID and A)
Flow 1. ACK Polling Sequence
NONVOLATILE WRITE
COMMAND COMPLETED
ENTERACK POLLING
ISSUE
START
ISSUE STOP
NO
The next byte sent to the X9118 contains the instruction and
register pointer information. The three most significant bits are
used to provide the instruction opcode (I[2:0]). The RB and RA
bits point to one of the four registers. The format is shown in
Table 2.
Table 3 provides a complete summary of the instruction set
opcodes.
YES
FURTHER
OPERATION?
The A[1:0] bits in the ID byte are the internal slave address.
The physical device address is defined by the state of the A1A0 input pins. The slave address is externally specified by the
user. The X9118 compares the serial data stream with the
address input state; a successful compare of both address bits
is required for the X9118 to successfully continue the
command sequence. Only the device which slave address
matches the incoming device address sent by the master
executes the instruction. The A1 to A0 inputs can be actively
driven by CMOS input signals or tied to VCC or VSS. The R/W
bit is the LSB and used to set the device for read or write
operations.
INSTRUCTION BYTE AND REGISTER SELECTION
ISSUE SLAVE
ADDRESS
ACK
RETURNED?
Following a start condition, the master must output the address
of the slave it is accessing. The most significant
4 bits of the slave address are the device type identifier. The
ID[3:0] bits is the device ID for the X9118; this is fixed as
0101[B] (refer to Table 1 on page 6).
NO
YES
ISSUE
INSTRUCTION
PROCEED
FN8161 Rev 5.00
April 9, 2014
ISSUE STOP
PROCEED
Page 5 of 17
X9118
TABLE 1. IDENTIFICATION BYTE FORMAT
DEVICE TYPE
IDENTIFIES
INTERNAL SLAVE
ADDRESS
SET TO 0
FOR PROPER
OPERATION
READ OR
WRITE BIT
ID3
ID2
ID1
ID0
0
A1
A0
R/W
0
1
0
1
0
A1
A0
R/W
(MSB)
(LSB)
TABLE 2. INSTRUCTION BYTE FORMAT
INSTRUCTION
OPCODE
I2
REGISTER
SELECTION
SET TO 0
FOR PROPER
OPERATION
I1
I0
0
RB
SET TO 0 FOR
PROPER OPERATION
RA
0
0
(MSB)
(LSB)
REGISTER SELECTED
RB
RA
DR0
0
0
DR1
0
1
DR2
1
0
DR3
1
1
TABLE 3. INSTRUCTION SET
INSTRUCTION SET
INSTRUCTION
R/W
I2
I1
I0
0
RB
RA
0
0
Read Wiper Counter Register
1
1
0
0
0
0
0
0
0
Read the contents of the Wiper Counter Register
Write Wiper Counter Register
0
1
0
1
0
0
0
0
0
Write new value to the Wiper Counter Register
Read Data Register
1
1
0
1
0
1/0
1/0
0
0
Read the contents of the Data Register pointed to
RB-RA.
Write Data Register
0
1
1
0
0
1/0
1/0
0
0
Write new value to the Data Register pointed to
RB-RA.
XFR Data Register to Wiper
Counter Register
1
1
1
0
0
1/0
1/0
0
0
Transfer the contents of the Data Register pointed to
by RB-RA to the Wiper Counter Register
XFR Wiper Counter Register
to Data Register
0
1
1
1
0
1/0
1/0
0
0
Transfer the contents of the Wiper Counter Register
to the Data Register pointed to by RB-RA.
OPERATION
NOTE:
3. 1/ = data is one or zero.
FN8161 Rev 5.00
April 9, 2014
Page 6 of 17
X9118
Four of the six instructions are four bytes in length. These
instructions are:
Instruction and Register Description
Device Addressing
• Read Wiper Counter Register – Read the current wiper
position of the potentiometer.
WIPER COUNTER REGISTER (WCR)
The X9118 contains a Wiper Counter Register (see Table 4) for
the XDCP potentiometer. The WCR is equivalent to a serial-in,
parallel-out register/counter with its outputs decoded to select
one of 1024 switches along its resistor array. The contents of
the WCR can be altered in one of three ways:
1. It may be written directly by the host via the write Wiper
Counter Register instruction (serial load).
2. It may be written indirectly by transferring the contents of
one of four associated Data Registers via the XFR Data
register.
3. It is loaded with the contents of its Data Register zero (R0)
upon power-up.
The Wiper Counter Register is a volatile register; that is,
contents are lost when the X9118 is powered down. Although
the register is automatically loaded with the value in DR0 upon
power-up, this may be different from the value present at powerdown. Power-up guidelines are recommended to ensure proper
loadings of the DR0 value into the WCR.
DATA REGISTERS (DR)
The potentiometer has four 10-bit non-volatile Data Registers.
These can be read or written directly by the host. Data can be
transferred between any of the four data registers and the
Wiper Counter Register. All operations changing data in one of
the Data Registers is a nonvolatile operation and will take a
maximum of 10ms.
• Write Wiper Counter Register – Change current wiper
position of the potentiometer.
• Read Data Register – Read the contents of the selected
Data Register.
• Write Data Register – Write a new value to the selected
Data Register.
The basic sequence of the four byte instructions is illustrated in
Figure 3. These four-byte instructions exchange data between
the WCR and one of the Data Registers. A transfer from a data
register to a WCR is essentially a write to a static RAM, with the
static RAM controlling the wiper position. The response of the
wiper to this action will be delayed by tWRL. A transfer from the
WCR (current wiper position), to a data register is a write to
nonvolatile memory and takes a minimum of tWR to complete.
The transfer can occur between the potentiometer and one of its
associated registers.
Two instructions (see Figure 4) require a two-byte sequence to
complete. These instructions transfer data between the host
and the X9118; either between the host and one of the Data
Registers or directly between the host and the Wiper Counter
Register. These instructions are:
• XFR Data Register to Wiper Counter Register – This
transfers the contents of one specified Data Register to the
Wiper Counter Register.
If the application does not require storage of multiple settings
for the potentiometer, the Data Registers can be used as
regular memory locations for system parameters or user
preference data.
• XFR Wiper Counter Register to Data Register –This
transfers the contents of the specified Wiper Counter
Register to the specified Data Register.
Bit 9 to Bit 0 are used to store one of the 1024 wiper position (0
~1023).
Other
Refer to “Instruction Format” on page 8 for more details.
POWER-UP AND POWER-DOWN REQUIREMENTS
At all times, the V+ voltage must be greater than or equal to the
voltage at RH or RL, and the voltage at RH or RL must be
greater than or equal to the voltage at V-. During power-up
and power-down, VCC, V+, and V- must reach their final
values within 1ms of each other.
TABLE 4. WIPER CONTROL REGISTER, WCR (10-BIT), WCR9 TO WCR0: USED TO STORE THE CURRENT WIPER POSITION (VOLATILE, V)
WCR9
WCR8
WCR7
WCR6
WCR5
WCR4
WCR3
WCR2
WCR1
WCR0
V
V
V
V
V
V
V
V
V
V
(MSB)
(LSB)
TABLE 5. DATA REGISTER, DR (10-BIT), BIT 9 TO BIT 0: USED TO STORE WIPER POSITIONS OR DATA (NON-VOLATILE, NV)
BIT 9
BIT 8
BIT 7
BIT 6
BIT 5
BIT 4
BIT 3
BIT 2
BIT 1
BIT 0
NV
NV
NV
NV
NV
NV
NV
NV
NV
NV
MSB
FN8161 Rev 5.00
April 9, 2014
LSB
Page 7 of 17
X9118
SCL
SDA
0
1
0
1
S ID3 ID2 ID1 ID0
T
A
DEVICE ID
R
T
0
A1
A0 R/W
INTERNAL
ADDRESS
0
0
A I2
I1 I0 0
C
K INSTRUCTION
OPCODE
RB RA 0
0
A
C
K
REGISTER
ADDRESS
S
T
O
P
FIGURE 3. TWO-BYTE INSTRUCTION SEQUENCE
SCL
SDA
0
1
0
1
0
0
0 X
X
0
0
X
S ID3 ID2 ID1 ID0 0 A1 A0 R/W A I2 I1 I0 0 RB RA 0
T
C
A DEVICE ID
INTERNAL K INSTRUCTION REGISTER
R
OPCODE
ADDRESS
ADDRESS
T
X X
X
X X
A
C
K
W
C
R
9
W A W W
C C C C
R K R R
8
7 6
W
C
R
5
W
C
R
4
W
C
R
3
W
C
R
2
W
C
R
1
W A
C C
R K
0
S
T
O
P
WIPER OR DATA
POSITION
FIGURE 4. FOUR-BYTE INSTRUCTION SEQUENCE (WRITE OR READ FOR WCR OR DATA REGISTERS)
Instruction Format
Read Wiper Counter Register (WCR)
DEVICE
ADDRESSES
R/W = 1
DEVICE TYPE
S IDENTIFIER
T
A
R 0 1 0 1
T
0 A1 A0
INSTRUCTION
OPCODE
S
A
C
K
1
0
0
REGISTER
ADDRESSES
0
0
0
0
0
WIPER POSITION
(SENT BY SLAVE ON SDA)
S
A
W W
C
C C
X
X
X
X
X
X
K
R R
9
WIPER POSITION
(SENT BY SLAVE ON SDA)
M
A W W W
C C C C
K R R R
7 6 5
8
W
C
R
3
W
C
R
4
W
C
R
2
W
C
R
1
M S
W A T
C C O
R K P
0
Write Wiper Counter Register (WCR)
INSTRUCTION
OPCODE
R/W = 0
DEVICE
S DEVICE TYPE
IDENTIFIER
ADDRESSES
T
A
R
0 1 0 1 0 A1 A0
T
S
A
C
K 1
0
1
REGISTER
ADDRESSES
0
0
0
0
WIPER
POSITION
(SENT BY MASTER ON SDA)
WIPER POSITION
(SENT BY MASTER ON SDA)
0
S
A
C
K X
X
X X
X
S
A
W W
W W
C
C C
C C
K
X
R R
R R
7 6
9 8
S
A
W W W W W W
C
C C C C C C
K
R R R R R R
5 4 3 2 1 0
S
T
O
P
Read Data Register (DR)
DEVICE
ADDRESSES
0 A1 A0
FN8161 Rev 5.00
April 9, 2014
R/W = 1
DEVICE TYPE
S IDENTIFIER
T
A
R 0 1 0 1
T
S
A
C
K
INSTRUCTION
OPCODE
1
0
1
0
REGISTER
ADDRESSES
RB
RA
0
WIPER POSITION
(SENT BY SLAVE ON SDA)
S
A
W
C
C
0 K X X X X X X
R
9
WIPER POSITION OR DATA
(SENT BY SLAVE ON SDA)
M
W A W W W
C C C C C
K
R R R
R
7 6 5
8
W
C
R
4
W
C
R
3
W
C
R
2
W
C
R
1
M S
W A T
C C O
R K P
0
Page 8 of 17
X9118
DEVICE
ADDRESSES
0 A1 A0
INSTRUCTION
OPCODE
R/W = 0
DEVICE TYPE
S IDENTIFIER
T
A
R 0 1 0 1
T
S
A
C
K 1
1 0
0
REGISTER
ADDRESSES
WIPER POSITION OR DATA
(SENT BY MASTER ON SDA)
S
A
W
C
C
RB RA 0 0 K X X X X X X
R
9
WIPER POSITION OR DATA
(SENT BY MASTER ON SDA)
S
W A W W W
C C C C C
R K R R R
7 6 5
8
W
C
R
4
W
C
R
3
W
C
R
2
W
C
R
1
S S
W A T
C C O
R K P
0
HIGH-VOLTAGE
WRITE CYCLE
Write Data Register (DR)
Transfer Wiper Counter Register (WCR) to Data Register (DR)
R/W = 0
DEVICE
S DEVICE TYPE
IDENTIFIER
ADDRESSES
T
A
R 0 1 0 1 0 A1 A0
T
S
A
C
K
INSTRUCTION
OPCODE
1
1
1
0
REGISTER
ADDRESSES
RB RA 0
S
A
C
0 K
S
T
O
P
HIGH-VOLTAGE
WRITE CYCLE
Transfer Data Register (DR) to Wiper Counter Register (WCR)
R/W = 1
DEVICE
S DEVICE TYPE
IDENTIFIER
ADDRESSES
T
A
R 0 1 0 1 0 A1 A0
T
S
A
C
K
INSTRUCTION
OPCODE
1
1
0
0
REGISTER
ADDRESSES
RB RA 0
S
A
C
0 K
S
T
O
P
NOTES:
1. “A1 ~ A0”: stands for the device addresses sent by the master.
2. WCRx refers to wiper position data in the Wiper Counter Register.
FN8161 Rev 5.00
April 9, 2014
Page 9 of 17
X9118
Absolute Maximum Ratings
Thermal Information
Temperature Under Bias . . . . . . . . . . . . . . . . . . . . .-65°C to +135°C
Voltage on SCL, SDA, or Any Address Input
with Respect to VSS. . . . . . . . . . . . . . . . . . . . . . . . . . . -1V to +7V
Voltage on V+ (referenced to VSS) (Note 8) . . . . . . . . . . . . . . . .10V
Voltage on V- (referenced to VSS) (Note 8) . . . . . . . . . . . . . . . . -10V
(V+) – (V-) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12V
Any Voltage on RH/RL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .V+
Any Voltage on RL/RH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . VIW (10s) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±6mA
Supply Voltage (VCC) Limits (Note 8)
X9118 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5V ±10%
X9118-2.7 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2.7V to 5.5V
Thermal Resistance (Typical, Note 3, 4) . JA (°C/W) JC (°C/W)
14 Ld TSSOP . . . . . . . . . . . . . . . . . . . .
92
25
Storage Temperature . . . . . . . . . . . . . . . . . . . . . . . .-65°C to +150°C
Pb-Free Reflow Profile. . . . . . . . . . . . . . . . . . . . . . . . .see link below
http://www.intersil.com/pbfree/Pb-FreeReflow.asp
Recommended Operating Conditions
Commercial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0°C to +70°C
Industrial . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .-40°C to +85°C
Power Rating (each pot) . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50mW
Wiper current (max) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±3mA
CAUTION: Do not operate at or near the maximum ratings listed for extended periods of time. Exposure to such conditions may adversely impact product
reliability and result in failures not covered by warranty.
NOTES:
3. JA is measured with the component mounted on a high effective thermal conductivity test board in free air. See Tech Brief TB379 for details.
4. For JC, the “case temp” location is taken at the package top center.
Analog Specifications
SYMBOL
RTOTAL
TA = +25°C, unless otherwise noted. Boldface limits apply across the operating temperature range , -40°C to +85°C.
PARAMETER
TEST CONDITIONS
MIN
(Note 10)
End to End Resistance
TYP
MAX
(Note 10)
k
End to End Resistance Tolerance
RW
Wiper Resistance
UNITS
100
IW = (VRH - VRL)/RTOTAL, VCC = 3V, VRL = -3V
150
±20
%
500
RW
Wiper Resistance
IW = (VRH - VRL)/RTOTAL, VCC = 5V, VRL = 0V
100
Vv+
Voltage on V+ Pin
X9118 (Note 8)
+4.5
+5.5
V
X9118-2.7 (Note 8)
+2.7
+5.5
V
Vv-
Voltage on V- Pin
X9118
-5.5
-4.5
V
X9118-2.7
-5.5
-2.7
V
Voltage on any RH or RL Pin
VSS = 0V
V-
Noise
Ref: 1kHz
VTERM
Resolution
V+
V
-120
dBV
0.1
%
Absolute Linearity (Note 5)
Rw(n)(actual) – Rw(n)(expected), where n = 1 to
1023
±1.5
MI
(Note 7)
Relative Linearity (Note 6)
Rw(m + 1) – [Rw(m) + MI], where m = 1 to 1023
±1.5
MI
(Note 7)
Temperature Coefficient of RTOTAL
CH/CL/CW
40
Ratiometric Temperature
Coefficient
Wiper at middle point
Potentiometer Capacitances
See Macro model
300
ppm/°C
20
ppm/°C
10/10
/25
pF
NOTES:
5. Absolute linearity is utilized to determine actual wiper voltage versus expected voltage as determined by wiper position when used as a
potentiometer.
6. Relative linearity is utilized to determine the actual change in voltage between two successive tap positions when used as a
potentiometer. It is a measure of the error in step size.
7. MI = RTOT/1023 or (RH – RL)/1023, single pot.
8. VCC, V+, V- must reach their final values within 1ms of each other.
9. n = 0, 1, 2, …,1023; m = 0, 1, 2, …, 1022.
FN8161 Rev 5.00
April 9, 2014
Page 10 of 17
X9118
DC Operating Specifications
-40°C to +85°C.
SYMBOL
TA = +25°C, unless otherwise noted. Boldface limits apply across the operating temperature range ,
PARAMETER
MIN
MAX
(Note 10) TYP (Note 10) UNITS
TEST CONDITIONS
3
mA
VCC Supply Current (Nonvolatile Write) fSCL = 400kHz; VCC = +5.5V; SDA = Open;
(for 2-wire, Active, Non-volatile Write State only)
7
mA
ISB
VCC Current (Standby)
VCC = +5.5V; VIN = VSS or VCC; SDA = VCC;
(for 2-wire, Standby State only)
15
A
ILI
Input Leakage Current
VIN = VSS to VCC
10
A
ILO
Output Leakage Current
VOUT = VSS to VCC
10
A
VIH
Input HIGH Voltage
VCC x 0.7
VCC + 1
V
VIL
Input LOW Voltage
-1
VCC x 0.3
V
VOL
Output LOW Voltage
0.4
V
ICC1
VCC Supply Current (Active)
ICC2
fSCL = 400kHz; VCC = +5.5V; SDA = Open;
(for 2-wire, Active, Read and Volatile Write States only)
IOL = 3mA
NOTE:
10. Parameters with MIN and/or MAX limits are 100% tested at +25°C, unless otherwise specified. Temperature limits established by characterization
and are not production tested.
Endurance and Data Retention
PARAMETER
MIN
UNITS
Minimum Endurance
100,000
Data changes per bit per register
Data Retention
100
years
Capacitance
SYMBOL
CIN/OUT
(Note 11)
CIN (Note 11)
TYP
UNITS
TEST CONDITIONS
Input/Output Capacitance (SI)
TEST
8
pF
VOUT = 0V
Input Capacitance (SCL, WP, A1 and A0)
6
pF
VIN = 0V
Power-Up Timing
SYMBOL
PARAMETER
MIN
MAX
UNITS
0.2
50
V/ms
tr VCC (Note 11)
VCC Power-up Rate
tPUR (Note 12)
Power-up to Initiation of Read Operation
1
ms
tPUW (Note 12)
Power-up to Initiation of Write Operation
50
ms
NOTES:
11. This parameter is not 100% tested.
12. tPUR and tPUW are the delays required from the time the (last) power supply (VCC-) is stable until the specific instruction can be issued. These
parameters are periodically sampled and not 100% tested.
AC Test Conditions
Input Pulse Levels
Input Rise and Fall Times
Input and Output Timing Level
FN8161 Rev 5.00
April 9, 2014
VCC x 0.1 to VCC x 0.9
10ns
VCC x 0.5
Page 11 of 17
X9118
Equivalent A.C. Load Circuit
5V
3V
1533Ω
SPICE MACROMODEL
867Ω
RTOTAL
RL
RH
SDA OUTPUT
SDA OUTPUT
100pF
CW
CL
10pF
CL
10pF
25pF
100pF
RW
AC Timing High-Voltage Write Cycle Timing
SYMBOL
PARAMETER
MIN
MAX
UNITS
400
kHz
fSCL
Clock Frequency
tCYC
Clock Cycle Time
2500
ns
tHIGH
Clock High-Time
600
ns
tLOW
Clock Low-Time
1300
ns
tSU:STA
Start Setup Time
600
ns
tHD:STA
Start Hold Time
600
ns
tSU:STO
Stop Setup Time
600
ns
tSU:DAT
SDA Data Input Setup Time
100
ns
tHD:DAT
SDA Data Input Hold Time
30
ns
tR
SCL and SDA Rise Time
300
ns
tF
SCL and SDA Fall Time
300
ns
tAA
SCL Low to SDA Data Output Valid Time
tDH
250
ns
SDA Data Output Hold Time
0
ns
tI
Noise Suppression Time Constant at SCL and SDA inputs
50
ns
tBUF
Bus Free Time (Prior to Any Transmission)
1300
ns
tSU:WPA
A0, A1 Setup Time
0
ns
tHD:WPA
A0, A1 Hold Time
0
ns
High-Voltage Write Cycle Timing
SYMBOL
tWR
PARAMETER
High-Voltage Write Cycle Time (store instructions)
TYP
MAX
UNITS
5
10
ms
XDCP Timing
SYMBOL
PARAMETER
TYP
UNITS
tWRPO
Wiper Response Time After the Third (last) Power Supply is Stable
8
µs
tWRL
Wiper Response Time After Instruction Issued (all load instructions)
8
µs
FN8161 Rev 5.00
April 9, 2014
Page 12 of 17
X9118
Symbol Table
WAVEFORM
INPUTS
OUTPUTS
Must be
steady
Will be
steady
May change
from Low to
High
Will change
from Low to
High
May change
from High to
Low
Will change
from High to
Low
Don’t Care:
Changes
Allowed
Changing:
State Not
Known
N/A
Center Line
is High
Impedance
Timing Diagrams
Start and Stop Timing
(START)
(STOP)
tR
tF
SCL
tSU:STA
tHD:STA
tSU:STO
tR
tF
SDA
Input Timing
tCYC
tHIGH
SCL
tLOW
SDA
tSU:DAT
tHD:DAT
tBUF
Output Timing
SCL
SDA
tAA
FN8161 Rev 5.00
April 9, 2014
tDH
Page 13 of 17
X9118
XDCP Timing (For All Load Instructions)
(STOP)
SCL
LSB
SDA
tWRL
RW
Write Protect and Device Address Pins Timing
(START)
(STOP)
SCL
...
(ANY INSTRUCTION)
...
SDA
...
tSU:WPA
tHD:WPA
WP
A0, A1
Applications Information
Basic Configurations of Electronic Potentiometers
+VR
VR
RW
I
Three terminal Potentiometer;
Variable voltage divider
FN8161 Rev 5.00
April 9, 2014
Two terminal Variable Resistor;
Variable current
Page 14 of 17
X9118
Application Circuits
NONINVERTING AMPLIFIER
VS
VOLTAGE REGULATOR
+
VO
–
VIN
VO (REG)
317
R1
R2
Iadj
R1
R2
VO = (1+R2/R1)VS
VO (REG) = 1.25V (1+R2/R1)+Iadj R2
COMPARATOR WITH HYSTERISIS
OFFSET VOLTAGE ADJUSTMENT
R1
R2
VS
VS
–
+
VO
100kΩ
–
VO
+
+12V
10kΩ
}
10kΩ
}
TL072
10kΩ
R1
R2
VUL = {R1/(R1+R2)} VO(max)
RLL = {R1/(R1+R2)} VO(min)
-12V
© Copyright Intersil Americas LLC 2005-2014. All Rights Reserved.
All trademarks and registered trademarks are the property of their respective owners.
For additional products, see www.intersil.com/en/products.html
Intersil products are manufactured, assembled and tested utilizing ISO9001 quality systems as noted
in the quality certifications found at www.intersil.com/en/support/qualandreliability.html
Intersil products are sold by description only. Intersil may modify the circuit design and/or specifications of products at any time without notice, provided that such
modification does not, in Intersil's sole judgment, affect the form, fit or function of the product. Accordingly, the reader is cautioned to verify that datasheets are
current before placing orders. Information furnished by Intersil is believed to be accurate and reliable. However, no responsibility is assumed by Intersil or its
subsidiaries for its use; nor for any infringements of patents or other rights of third parties which may result from its use. No license is granted by implication or
otherwise under any patent or patent rights of Intersil or its subsidiaries.
For information regarding Intersil Corporation and its products, see www.intersil.com
FN8161 Rev 5.00
April 9, 2014
Page 15 of 17
X9118
Application Circuits (Continued)
ATTENUATOR
FILTER
C
VS
+
R2
R1
VS
VO
–
–
R
VO
+
R3
R4
R2
R1 = R2 = R3 = R4 = 10kW
R1
GO = 1 + R2/R1
fc = 1/(2RC)
VO = G VS
-1/2 G +1/2
R2
}
VS
R1
}
INVERTING AMPLIFIER
EQUIVALENT L-R CIRCUIT
R2
C1
VS
–
+
–
VO
+
R1
ZIN
R3
VO = G VS
G = - R2/R1
ZIN = R2 + s R2 (R1 + R3) C1 = R2 + s Leq
(R1 + R3) >> R2
FUNCTION GENERATOR
R2
–
C
R1
–
+
} RA
+
} RB
frequency R1, R2, C
amplitude RA, RB
FN8161 Rev 5.00
April 9, 2014
Page 16 of 17
X9118
Package Outline Drawing
M14.173
14 LEAD THIN SHRINK SMALL OUTLINE PACKAGE (TSSOP)
Rev 3, 10/09
A
1
3
5.00 ±0.10
SEE
DETAIL "X"
8
14
6.40
PIN #1
I.D. MARK
4.40 ±0.10
2
3
1
0.20 C B A
7
B
0.65
0.09-0.20
TOP VIEW
END VIEW
1.00 REF
0.05
H
C
0.90 +0.15/-0.10
1.20 MAX
SEATING
PLANE
0.25 +0.05/-0.06
0.10 C
0.10
GAUGE
PLANE
0.25
5
0°-8°
0.05 MIN
0.15 MAX
CBA
SIDE VIEW
0.60 ±0.15
DETAIL "X"
(1.45)
NOTES:
1. Dimension does not include mold flash, protrusions or gate burrs.
(5.65)
Mold flash, protrusions or gate burrs shall not exceed 0.15 per side.
2. Dimension does not include interlead flash or protrusion. Interlead
flash or protrusion shall not exceed 0.25 per side.
3. Dimensions are measured at datum plane H.
4. Dimensioning and tolerancing per ASME Y14.5M-1994.
5. Dimension does not include dambar protrusion. Allowable protrusion
shall be 0.80mm total in excess of dimension at maximum material
condition. Minimum space between protrusion and adjacent lead is 0.07mm.
(0.65 TYP)
(0.35 TYP)
TYPICAL RECOMMENDED LAND PATTERN
FN8161 Rev 5.00
April 9, 2014
6. Dimension in ( ) are for reference only.
7. Conforms to JEDEC MO-153, variation AB-1.