0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
QPA3240

QPA3240

  • 厂商:

    RFMD(威讯)

  • 封装:

    SOT-115J

  • 描述:

    ICPWRDOUBLER1.2GHZSOT-115J

  • 数据手册
  • 价格&库存
QPA3240 数据手册
RFMD + TriQuint = Qorvo QPA3240 QPA3240 GaAs/GaN Power Doubler Hybrid 45MHz to 1218MHz The QPA3240 is a Hybrid Power Doubler amplifier module. The part employs GaAs pHEMT die and GaN HEMT die, has extremely high output capability, and is operated from 45MHz to 1218MHz. It provides excellent linearity and superior return loss performance with low noise and optimal reliability. DC current of the device can be externally adjusted for optimum distortion performance versus power consumption over a wide range of output level. Current setting V+ OUTPUT INPUT Package: SOT-115J Features ■ Excellent Linearity ■ Superior Return Loss Performance ■ Optimal Reliability ■ Low Noise ■ Unconditionally Stable Under All Terminations ■ 24.5dB Min. Gain at 1218MHz ■ 480mA Max. ■ Extra Pin For Current Adjustment Applications Functional Block Diagram ■ 45MHz to 1218MHz CATV Amplifier Systems ■ DOCSIS 3.1 Compliant Ordering Information QPA3240 Box with 50 pieces Revision DS20150922 © 2015 RF Micro Devices, Inc. - 1 of 7 - Disclaimer: Subject to change without notice www.rfmd.com / www.qorvo.com QPA3240 RFMD + TriQuint = Qorvo Absolute Maximum Ratings Parameter Rating Unit RF Input Voltage (single tone) 75 dBmV DC Supply Over-Voltage (5 minutes) 30 V Storage Temperature -40 to +100 °C Operating Mounting Base Temperature -30 to +100 °C Caution! ESD sensitive device. RFMD Green: RoHS status based on EU Directive 2011/65/EU (at time of this document revision), halogen free per EN 14582 : 2007, < 1000ppm each of antimony trioxide in polymeric materials and red phosphorus as a flame retardant, and 370mA Operating Frequency Range Power Gain Slope[1] 45 Output Return Loss Noise Figure Total Current Consumption (DC) Revision DS20150922 © 2015 RF Micro Devices, Inc. MHz 23.3 23.8 24.3 dB f = 45MHz 24.5 24.8 26.0 dB f = 1218MHz 0.5 1.0 2.0 dB f = 45MHz to 1218MHz 0.8 dB f = 45MHz to 1218MHz 20 dB f = 45MHz to 320MHz 19 dB f = 320MHz to 640MHz 18 dB f = 640MHz to 870MHz 18 dB f = 870MHz to 1000MHz 17 dB f = 1000MHz to 1218MHz 20 dB f = 45MHz to 320MHz 19 dB f = 320MHz to 640MHz 18 dB f = 640MHz to 870MHz 18 dB f = 870MHz to 1000MHz 17 dB f = 1000MHz to 1218MHz f = 50MHz to 1218MHz Flatness of Frequency Response Input Return Loss 1218 3.0 4.0 dB 470.0 480.0 mA - 2 of 7 - Disclaimer: Subject to change without notice www.rfmd.com / www.qorvo.com QPA3240 RFMD + TriQuint = Qorvo Specification Parameter Unit Min Typ Condition Max Distortion Data 40MHz to 550MHz. Test conditions: V+ = 24V; TMB = 30°C; ZS = ZL = 75Ω, IDC=IDC typical CTB -73 -68 dBc XMOD -68 -63 dBc CSO -76 -70 dBc CIN 55 57 VO = 62 dBmV at 1000MHz, 18dB extrapolated tilt, 79 analog channels plus 75 digital channels (-6dB offset)[2][5] dB Distortion Data 40MHz to 550MHz. Test conditions: V+ = 24V; TMB = 30°C; ZS = ZL = 75Ω, IDC=IDC typical CTB -80 dBc XMOD -77 dBc CSO -80 dBc CIN 58 dB VO = 62 dBmV at 1218MHz, 22dB extrapolated tilt, 79 analog channels plus 111 digital channels (-6dB offset)[3][5] Distortion Data 40MHz to 550MHz. Test conditions: V+ = 24V; TMB = 30°C; ZS = ZL = 75Ω, IDC=400mA CTB -72 dBc XMOD -67 dBc CSO -70 dBc CIN 50 dB VO = 62 dBmV at 1218MHz, 22dB extrapolated tilt, 79 analog channels plus 111 digital channels (-6dB offset)[3][6] 1. The slope is defined as the difference between the gain at the start frequency and the gain at the stop frequency. 2. 79 analog channels, NTSC frequency raster: 55.25MHz to 547.25MHz, +44dBmV to +53.4dBmV tilted output level, plus 75 digital channels, -6dB offset relative to the equivalent analog carrier. 3. 79 analog channels, NTSC frequency raster: 55.25MHz to 547.25MHz, +40dBmV to +49.4dBmV tilted output level, plus 111 digital channels, -6dB offset relative to the equivalent analog carrier. 4. Composite Triple Beat (CTB) - The CTB parameter is defined by the NCTA. Composite Second Order (CSO) - The CSO parameter (both sum and difference products) is defined by the NCTA. Cross Modulation (XMOD) - Cross modulation (XMOD) is measured at baseband (selective voltmeter method), referenced to 100% modulation of the carrier being tested. Carrier to Intermodulation Noise (CIN) - The CIN parameter is defined by ANSI/SCTE 17 (Test Procedure for carrier to noise). 5. Test condition: Pin 4 not connected 6. Test condition: Pin 4 connected to GND via 3.9k resistor Revision DS20150922 © 2015 RF Micro Devices, Inc. - 3 of 7 - Disclaimer: Subject to change without notice www.rfmd.com / www.qorvo.com QPA3240 RFMD + TriQuint = Qorvo Current Adjustment Using Hybrid Pin 4 The QPA3240 can be operated over a wide range of current to provide maximum required performance with minimum current consumption. A single external resistor connected between pin 4 and GND allows variation of current between 470mA and 150mA (typ.). Within the recommended range of current between 470mA and 370mA gain (S21) change is less than 0.2dB and noise figure change is less than 0.1dB. If pin 4 is not connected the devices operates at maximum current, see table below. Examples of connecting pin 4: V+ V+ 5 5 1 INPUT 9 4 OUTPUT INPUT 1 9 4 2, 3, 7, 8 OUTPUT 2, 3, 7, 8 Resistor, variable, 50k range, or VCR Resistor, fixed QPA3240 Current vs. external resistor Device current [mA], typical 500 External resistor [Ω] 470 >50k (open) 450 16k 430 7k5 400 3k9 250 370 2k4 200 340 1k5 150 150 0 (short) 450 I [mA] 400 350 300 0 10 20 30 40 50 V+ = 24V; TMB = 30°C; ZS = ZL = 75Ω R [kOhm] Revision DS20150922 © 2015 RF Micro Devices, Inc. - 4 of 7 - Disclaimer: Subject to change without notice www.rfmd.com / www.qorvo.com QPA3240 RFMD + TriQuint = Qorvo Change of Distortion Performance Over Current Test Condition: V+=24V, TMB = 30°C; ZS = ZL = 75Ω,VO = 62.0dBmV at 1000MHz, 18dB extrapolated tilt, 79 analog channels plus 75 digital channels (-6dB offset) CTB change over device current, typical values 0 100 200 300 400 500 600 0,0 f [MHz] CTB delta [dB] 2,0 4,0 470mA 450mA 430mA 410mA 390mA 370mA 6,0 8,0 10,0 12,0 CIN change over device current, typical values 0 100 200 300 400 0,0 500 600 f [MHz] CIN delta [dB] -2,0 -4,0 470mA 450mA 430mA 410mA 390mA 370mA -6,0 -8,0 -10,0 -12,0 Revision DS20150922 © 2015 RF Micro Devices, Inc. - 5 of 7 - Disclaimer: Subject to change without notice www.rfmd.com / www.qorvo.com QPA3240 RFMD + TriQuint = Qorvo Package Drawing (Dimensions in millimeters) Revision DS20150922 © 2015 RF Micro Devices, Inc. - 6 of 7 - Disclaimer: Subject to change without notice www.rfmd.com / www.qorvo.com QPA3240 RFMD + TriQuint = Qorvo Contact Information For the latest specifications, additional product information, worldwide sales and distribution locations: Web: www.rfmd.com Email: customer.support@qorvo.com Tel: 1-844-890-8163 For information about the merger of RFMD and TriQuint as Qorvo: Web: www.qorvo.com Important Notice The information contained herein is believed to be reliable. RFMD makes no warranties regarding the information contained herein. RFMD assumes no responsibility or liability whatsoever for any of the information contained herein. RFMD assumes no responsibility or liability whatsoever for the use of the information contained herein. The information contained herein is provided "AS IS, WHERE IS" and with all faults, and the entire risk associated with such information is entirely with the user. All information contained herein is subject to change without notice. Customers should obtain and verify the latest relevant information before placing orders for RFMD products. The information contained herein or any use of such information does not grant, explicitly or implicitly, to any party any patent rights, licenses, or any other intellectual property rights, whether with regard to such information itself or anything described by such information. RFMD products are not warranted or authorized for use as critical components in medical, life-saving, or life-sustaining applications, or other applications where a failure would reasonably be expected to cause severe personal injury or death. Revision DS20150922 © 2015 RF Micro Devices, Inc. - 7 of 7 - Disclaimer: Subject to change without notice www.rfmd.com / www.qorvo.com
QPA3240 价格&库存

很抱歉,暂时无法提供与“QPA3240”相匹配的价格&库存,您可以联系我们找货

免费人工找货