RFPD3540
RFPD3540
GaAs/GaN Power Doubler Hybrid
45MHz to 1218MHz
The RFPD3540 is a Hybrid Power Doubler amplifier module. The
part employs GaAs MesFET, GaAs pHemt die and GaN HEMT die,
has high output capability, and operates from 45MHz to 1218MHz.
It provides excellent linearity and superior return loss performance
with low noise and optimal reliability.
V+
INPUT
OUTPUT
Package: SOT-115J
Features
■
Extremely High Output
Capability
■
Excellent Linearity
■
Superior Return Loss
Performance
■
Optimal Reliability
■
Low Noise
■
Unconditionally Stable Under
All Terminations
■
27.0dB Min. Gain at 1218MHz
■
450mA Max. at 24VDC
Functional Block Diagram
Applications
Ordering Information
RFPD3540
■
45MHz to 1218MHz CATV
Amplifier Systems
■
DOCSIS 3.1 Compliant
Box with 50 pieces
Revision DS20160126
© 2016 RF Micro Devices, Inc.
- 1 of 5 -
Disclaimer: Subject to change without notice
www.rfmd.com / www.qorvo.com
RFPD3540
RFMD + TriQuint = Qorvo
Absolute Maximum Ratings
Parameter
Rating
Unit
RF Input Voltage (single tone)
75
dBmV
DC Supply Over-Voltage (5 minutes)
30
V
Storage Temperature
-40 to +100
°C
Operating Mounting Base Temperature
-30 to +100
°C
Caution! ESD sensitive device.
RoHS status based on EU Directive
2011/65/EU .
Exceeding any one or a combination of the Absolute
Maximum Rating conditions may cause permanent
damage to the device. Extended application of Absolute
Maximum Rating conditions to the device may reduce
device reliability. Specified typical performance or
functional operation of the device under Absolute
Maximum Rating conditions is not implied.
Electrical Specifications
Specification
Parameter
Unit
Min
Typ
Condition
Max
General Performance. Test conditions unless otherwise noted: V+ = 24V; TMB = 35°C; ZS = ZL = 75Ω
Operating Frequency Range
45
Power Gain
Slope[1]
1218
27.0
Output Return Loss
dB
f = 45MHz
27.0
28.0
29.0
dB
f = 1218MHz
0.5
1.0
2.0
dB
f = 45MHz to 1218MHz
0.8
dB
f = 45MHz to 1218MHz
-20
dB
f = 45MHz to 320MHz
-18
dB
f = 320MHz to 640MHz
-17
dB
f = 640MHz to 870MHz
-16
dB
f = 870MHz to 1000MHz
-15
dB
f = 1000MHz to 1218MHz
-20
dB
f = 45MHz to 320MHz
-19
dB
f = 320MHz to 640MHz
-18
dB
f = 640MHz to 870MHz
-17
dB
f = 870MHz to 1000MHz
Flatness of Frequency Response
Input Return Loss
MHz
dB
f = 1000MHz to 1218MHz
Noise Figure
5.1
5.5
dB
f = 50MHz to 1218MHz
Total Current Consumption (DC)
420
450
mA
-16
Revision DS20160126
© 2016 RF Micro Devices, Inc.
- 2 of 5 -
Disclaimer: Subject to change without notice
www.rfmd.com / www.qorvo.com
RFPD3540
RFMD + TriQuint = Qorvo
Specification
Parameter
Unit
Min
Typ
Condition
Max
Distortion Data 40MHz to 550MHz. Test conditions unless otherwise noted: V+ = 24V; TMB = 35°C; ZS = ZL = 75Ω
CTB
-80
dBc
XMOD
-76
dBc
CSO
-80
dBc
CIN
55
dB
VO = 59dBmV at 1218MHz, 22dB extrapolated tilt, 79 analog channels plus 111
digital channels (-6dB offset)[2][4]
Distortion Data 40MHz to 550MHz. Test conditions unless otherwise noted: V+ = 24V; TMB = 35°C; ZS = ZL = 75Ω
CTB
-76
-72
dBc
XMOD
-70
-65
dBc
CSO
-80
-70
dBc
CIN
1.
2.
3.
4.
55
58
VO = 58dBmV at 1218MHz, 16.5dB extrapolated tilt, 79 analog channels plus
111 digital channels (-6dB offset)[3][4]
dB
The slope is defined as the difference between the gain at the start frequency and the gain at the stop frequency.
79 analog channels, NTSC frequency raster: 55.25MHz to 547.25MHz, +37dBmV to +46.4dBmV tilted output level, plus 111 digital channels, 6dB offset relative to the equivalent analog carrier.
79 analog channels, NTSC frequency raster: 55.25MHz to 547.25MHz, +41.5dBmV to +48.5dBmV tilted output level, plus 111 digital channels, 6dB offset relative to the equivalent analog carrier.
Composite Second Order (CSO) - The CSO parameter (both sum and difference products) is defined by ANSI/SCTE 6. Composite Triple Beat
(CTB) - The CTB parameter is defined by ANSI/SCTE 6. Cross Modulation (XMOD) - Cross modulation (XMOD) is measured at baseband
(selective voltmeter method), referenced to 100% modulation of the carrier being tested. Carrier to Intermodulation Noise (CIN) - The CIN
parameter is defined by ANSI/SCTE 17 (Test procedure for carrier to noise).
Revision DS20160126
© 2016 RF Micro Devices, Inc.
- 3 of 5 -
Disclaimer: Subject to change without notice
www.rfmd.com / www.qorvo.com
RFPD3540
RFMD + TriQuint = Qorvo
Package Drawing (Dimensions in millimeters)
I
U
123 5 7 89
C
E
J
S
P
R
M
K
O
T
Q
øG
N
D
0
B
5 10mm
scale
H
L
F
A
Notes:
European
Projection
Nominal
Min
Max
A
44,6
± 0,2
44,4
44,8
B
13,6 ± 0,2
13,4
13,8
C
20,4 ± 0,5
19,9
20,9
D
8 ± 0,15
7,85
8,15
E
12,6 ± 0,15
12,45
12,75
F
38,1 ± 0,2
37,9
38,3
G
4 +0,2 / -0,05
3,95
4,2
H
Pinning:
Pin
Name
1
Input
2-3
GND
4
5
V+
6
4
± 0,2
3,8
4,2
25,2
25,6
I
25,4 ± 0,2
J
UNC 6-32
-
-
K
4,2 ± 0,2
4,0
4,4
L
27,2 ± 0,2
27,0
27,4
M
11,6 ± 0,5
11,1
12,1
N
5,8 ± 0,4
5,4
6,2
O
0,25 ± 0,02
0,23
0,27
P
0,45 ± 0,03
0,42
0,48
Q
2,54 ± 0,3
2,24
2,84
R
2,54 ± 0,5
2,04
3,04
S
2,54 ± 0,25
2,29
2,79
7-8
GND
T
5,08 ± 0,25
4,83
5,33
9
Output
U
5,08 ± 0,25
4,83
5,33
Revision DS20160126
© 2016 RF Micro Devices, Inc.
- 4 of 5 -
Disclaimer: Subject to change without notice
www.rfmd.com / www.qorvo.com
RFPD3540
RFMD + TriQuint = Qorvo
Contact Information
For the latest specifications, additional product information, worldwide sales and distribution locations:
Web: www.rfmd.com
Email: customer.support@qorvo.com
Tel: 1-844-890-8163
For information about the merger of RFMD and TriQuint as Qorvo:
Web:
www.qorvo.com
Important Notice
The information contained herein is believed to be reliable. RFMD makes no warranties regarding the information contained
herein. RFMD assumes no responsibility or liability whatsoever for any of the information contained herein. RFMD assumes
no responsibility or liability whatsoever for the use of the information contained herein. The information contained herein is
provided "AS IS, WHERE IS" and with all faults, and the entire risk associated with such information is entirely with the user.
All information contained herein is subject to change without notice. Customers should obtain and verify the latest relevant
information before placing orders for RFMD products. The information contained herein or any use of such information does
not grant, explicitly or implicitly, to any party any patent rights, licenses, or any other intellectual property rights, whether with
regard to such information itself or anything described by such information.
RFMD products are not warranted or authorized for use as critical components in medical, life-saving, or life-sustaining
applications, or other applications where a failure would reasonably be expected to cause severe personal injury or death.
Revision DS20160126
© 2016 RF Micro Devices, Inc.
- 5 of 5 -
Disclaimer: Subject to change without notice
www.rfmd.com / www.qorvo.com