0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
GSM100T

GSM100T

  • 厂商:

    RFSOLUTIONS

  • 封装:

  • 描述:

    GSM100T - GSM & GPRS MODEM - rfsolutions.ltd

  • 数据手册
  • 价格&库存
GSM100T 数据手册
GSM & GPRS MODEM • • • • • • • • • • • • • • • • • • • • • • • • • • • • • GSM and GPRS Voice / Fax / SMS and Data Dual Band 900 / 1800MHz GSM Transmission Full voice call, SMS support Accepts Standard SIM Card Data enabled SIM Cards available Miniature size 88 x 60 x 26mm Can Be Used On Standard GSM Network RS232 Interface AT command set (GSM 07.05 and 07.07) One user programmable input/Output Port GPRS Class B Class 10 (36Kb/s download / 24Kb/s upload) GSM100T: TCP/IP stack available for data and internet GSM100LITE GSM100T Data/Fax features: Data circuit asynchronous, transparent and non transparent up to 14,400 bits/s Automatic fax group 3 (Class 1 and Class 2) MNP2, V.42bis Miniature "Plug And Play" dual band GSM modems can be directly connected to the serial port of a desktop or notebook computer through the RS232 interface. A standard SIM card can be inserted in the integral cardholder within the metal enclosure. The Modems’ metal casing makes it an appropriate solution for tough applications such as Telemetry, Wireless Local Loop (payphones) or as part of a fleet management system. The small size makes it simple to integrate in a space constraint environment. The modem is supplied with power cable, other accessories available are an antenna (with 1m coax cable), RS232 connecting cable with Telephone interface, DIN Rail mounting adaptor, power supply unit and Data enabled SIM card. About GPRS: GPRS stands for General Packet Radio Services. The user can remain "ON" all the time and the data Communication speed rivals that of a cable modem. Voice features: Telephony Emergency calls Full Rate, Enhanced and Half Rate DTMF Function Data/Fax features: Data circuit asynchronous, transparent and non transparent up to 14,400 bits/s Automatic fax group 3 (Class 1 and Class 2) MNP2, V.42bis GSM Supplementary Services : Short Messages Services features: Text and PDU Point to point (MT/MO) Cell Broadcast One Programmable I/O Port One user programmable input/Output Port (3V CMOS logic) • • • • • • Call Forwarding -Calling Line Identity Call Barring -Advice of Charge Multiparty -USSD Call Waiting / Hold -Closed User Group Explicit Call Transfer Cell Broadcast DS020-7 Oct ‘06 ©2006 REG No 277 4001, ENGLAND. Page 1 GSM & GPRS MODEM Technical Specifications Max Storage Temperature Max Operating Temperature -10°C to +70°C, -15°C to +50°C GSM100LITE GSM100T Dimensions 88mm x 60mm x 26mm Weight 100grams Electrical Characteristics Supply Voltage Supply Current: In Communication Idle mode Idle mode with RS232 power saving Interfaces: SIM holder (integrated Drawer, accepts standard SIM card) 15 pin Sub-D type connector (for serial and audio connection) 4-pin power supply connector (micro-FITTM) SMA antenna connector (50 ohm) Power Supply Unit: Input: Output: 110-240Vac, 2 pin IEC connector 12Vdc +/-5%, 1A, 4 Pin micro-FITTM connector Min 5 Typical 450 25 13 Max 32 Units V mA mA mA Ordering Information Part No GSM100L GSM100T GSM20-Ant GSM20-CAB232 GSM20-DINRL GSM20-PSU Description GSM GPRS Class 10 Modem, dual Band As GSM100L with Additional TCP/IP Stack Antenna with flying lead and connector RS232 Cable Interface to PC DIN Rail Mount Bracket Power Supply (110-230Vac) For more information or general enquiries: R F Solutions Ltd., Unit 21, Cliffe Industrial Estate, Lewes, E. Sussex. BN8 6JL. England. Email : sales@rfsolutions.co.uk Tel: +44 (0)1273 898 000 http://www.rfsolutions.co.uk Fax: +44 (0)1273 480 661 Information contained in this document is believed to be accurate , however no representation or warranty is given and no liability is assumed by R.F. Solutions Ltd. with respect to the accuracy of such information. Use of R.F.Solutions as critical components in life support systems is not authorised except with express written approval from RFSolutions Ltd. DS020-7 Oct ‘06 ©2006 REG No 277 4001, ENGLAND. Page 2 GSM100 USERS MANUAL USER MANUAL Rev. 04, Nov 2003 CONTENTS SAFETY PRECUTIONS 2 CHAPTER 1 INTRODUCTION 3 CHAPTER 2 INSTALLATION 7 CHAPTER 3 WORKING WITH FARGO MAESTRO 9 CHAPTER 4 SPECIFICATION 12 CHAPTER 5 APPENDIX 13 CHAPTER 6 TROUBLESHOOTING 14 DS020-7 Oct ‘06 ©2006 REG No 277 4001, ENGLAND. Page 3 GSM100 USERS MANUAL SAFETY PRECUTIONS The modem generates radio frequency (RF) power. When using the modem care must be taken on safety issues related to RF interference as well as regulations of RF equipment. Do not use your phone in aircraft, hospitals, petrol stations or in places where using GSM products is prohibited. Be sure that the modem will not be interfering with nearby equipment. For example: pacemakers or medical equipment. The antenna of the modem should be away from computers, office equipment, home appliance, etc. An external antenna must be connected to the modem for proper operation. Only uses approved antenna with the modem. Please contact authorized dealer on finding an approved antenna. Always keep the antenna with minimum safety distance of 26.6 cm or more from human body. Do not put the antenna inside metallic box, containers, etc. Using the modem in vehicle Check for any regulation or law authorizing the use of GSM in vehicle in your country before installing the modem Install the modem by qualified personnel. Consult your vehicle dealer for any possible interference of electronic parts by the modem. The modem should be connected to the vehicle’s supply system by using a fuse-protected terminal in theehicle’s fuse box Be careful when the modem is powered by the vehicle’s main battery. The battery may be drained after extended period. Protecting your modem To ensure error-free usage, please install and operate your modem with care. Do remember the following: Do not expose the modem to extreme conditions such as high humidity/rain, high temperatures, direct sunlight, caustic/harsh chemicals, dust, or water. Do not try to disassemble or modify the modem. There is no user serviceable part inside and the warranty would be void. Do not drop, hit or shake the modem. Do not use the modem under extreme vibrating condition. Do not pull the antenna or power supply cable. Attach/ detach by holding the connector. Connect the modem only according to the instruction manual. Failure to do it will void the warranty. In case of problem, please contact authorized dealer. GENERAL DS020-7 Oct ‘06 ©2006 REG No 277 4001, ENGLAND. Page 4 GSM100 USERS MANUAL CHAPTER 1 INTRODUCTION Fargo Maestro is a ready-to-use GSM modem for voice, data, fax and SMS services. It also supports GPRS Class 10(Fargo Maestro 100) for hi-speed data transfer. The modems can be easily controlled by using AT command for all kinds of operations. With standard 9-pin RS232 port and telephone-like audio plug (via optional cable). 1.1. Package The Fargo Maestro package should include the following: 1.Fargo Maestro x 1 2. Power cord with fuse x 1 3. Safety note x 1 1.2. Interfaces S M A fe m a l e a n te n n a c o n n e c to r S ta tu s i n d i c a to r 15 pin Sub-D Female Connector (RS232/Audio) S IM h o l d e r e j e c t b u tto n S IM h o l d e r 4-PIN connector (Power, Input / Output) 1.2.1. Status indicator The LED will indicate different status of the modem: off on Modem switched off Modem is connecting to the network flashing slowly Modem is in idle mode flashing rapidly Modem is in transmission/communication (GSM only) 1.2.2. SMA female antenna connector Connect this to an external antenna with SMA male connector. Make sure the antenna is for the GSM900/1800 frequency with impedance of 50ohm, and also connector is secured tightly. DS020-7 Oct ‘06 ©2006 REG No 277 4001, ENGLAND. Page 5 GSM100 USERS MANUAL 1.2.3. 15-PIN D-SUB Female connector (RS232 / Audio) The connector provides serial link and audio link to the modem. Pin number 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Name DCD TX BOOT MICROPHONE (+) MICROPHONE (-) RX DSR DTR GND SPEAKER(+) CTS RTS RI RESET SPEAKER(-) EIA designation Data Carrier Detect Transmit Data Receive Data Data Set Ready Data Terminal Ready Ground Clear to Send Request to Send Ring Indicator Type Output Input Input Input Input Output Output Input Ground Output Output Input Output Input Output Note Not used Pull low to reset Specification of microphone and speaker to be connected : Parameters Microphone current @2V / 2K Ohm Microphone input level Min Typical 0.5 mA Max 100 mVpp Remark Speaker output current 150 Ohm/ 16mA 1nF Speaker impedance 32ohm Please refer to the document “Application notes - Power supply & Audio” for more information of audio connection. 1.2.4. 4-PIN modem socket (Power, Input / Output) Pin assignment of 4-pin connector Pin number 1 2 Name I/O ~INTR Functions Input / Output port Interrupt function triggered by pulling this pin to ground or LOW level; reserved for additional functions with new firmware DC power negative input DC power positive input 3 4 POWER POWER + DS020-7 Oct ‘06 ©2006 REG No 277 4001, ENGLAND. Page 6 GSM100 USERS MANUAL A cable, included in the package shall be used for power supply connection: 5- 32V D C Supply Connector Micro-Fit 3.0 (to Fargo Maestro) Fuse holder Fuse rating : 2 5 0 V 2 .5 A Stripped wire I/O Parameters LOW voltage HIGH voltage I/O out max. sink current Min 3V Typical Max 0.5V 5V 10mA Remark INTR Parameters LOW voltage • Remark Triggered by pulling this pin to LOW level; otherwise leave it open Please refers to Chapter 6 Appendix for using I/O and INTR signals. Contact your dealer if you need wire for the I/O and INTR connection Min 0 Typical Max 0.5V External antenna - Magnetic mount type - Frequency GSM 900/1800 band - Gain 3db - VSWR < 1.5:1 - Height ~ 236 mm (including magnetic base) - Cable : Type RG-174U length 2.5m - SMA male connector on cable end - color : back (SMA connector silver) 1.2.5 Optional accessories You may contact your sales agent for the following optional accessories: DS020-7 Oct ‘06 ©2006 REG No 277 4001, ENGLAND. Page 7 GSM100 USERS MANUAL ‘Y’ cable Pin Assignment Sub-D 15 (male) 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Sub-D 9 (female) 1 3 Plug 4P4C Direct connection with standard 9pin RS-232 port (DTE) Direct connection with common handset of telephone for voice call Shielded cable Cable length 1.1m (w/ connector) 1 4 2 6 4 5 2 8 7 9 3 Sub-D 9 pin 4p4c plug DIN rail mount Quick attachment / detachment to standard DIN rail Tin plated Steel DS020-7 Oct ‘06 ©2006 REG No 277 4001, ENGLAND. Page 8 GSM100 USERS MANUAL CHAPTER 2 INSTALLATION 2.1 Mounting the modem Use 2 pcs of M3 screw to mount the modem When using optional DIN rail mount please refer to document “Installation of DIN rail mount” Screw mounting slot Bottom view 2.2 Installing the SIM card Use a ball pen or paper clip to press the SIM holder eject button. The SIM holder will come out a little. Then take out the SIM holder. Note : DO NOT pull out the SIM holder without pushing the eject button. Put the SIM card to the tray, make sure it has completely sit on the tray. Put the tray back into the slot. 2.3 Connecting the external antenna (SMA type) Connect this to an external antenna with SMA male connector. Make sure the antenna is for the GSM900/1800 frequency with impedance of 50ohm, and also connector is secured tightly. Note : Please use antenna designed for GSM 900/1800 Mhz operation. Incorrect antenna will affect communication and even damage the modem. S M A m a l e c o n n e c to r o f a n te n n a c a b l e secure tightly DS020-7 Oct ‘06 ©2006 REG No 277 4001, ENGLAND. Page 9 GSM100 USERS MANUAL 2.4 Connect the modem to external device You can use the optional ‘Y’ cable to connect the modem’s Sub-D connector to external controller/computer. Note : The modem CANNOT be connected to the ‘Line’ jack of a landline telephone directly. Connection example using optional ‘Y’ cable: 4p4c pl ug Handset of phone Maestro 100 / Maestro 20 Sub-D 15 pin c o n n e c to r DB-9 c o n n e c t or RS-232 port of PC 2.5 Connecting the DC power supply Connect the open ending of the included power cord to a DC supply. Refer to the following for power supply requirement. Input voltage range 5V – 32V 650mA Rated current AC-DC Adaptor o r b a tte r y (not included) Solder wire e n d i ng s Connect the connector to the modem. The modem will turn on automatically. The status indicator on the modem will be lit when power on. After a few seconds it will go flashing slowly (registered to the network successfully, refer section 1.2.1). Chapter 3 describes how to communicate with the modem in Microsoft WindowsTM environment. DS020-7 Oct ‘06 ©2006 REG No 277 4001, ENGLAND. Page 10 GSM100 USERS MANUAL CHAPTER 3 WORKING WITH FARGO MAESTRO 3.1. Checking the modem (using Microsoft WindowsTM 98 HyperTerminal as example) 3.1.1. On the first time power-up you can use a terminal software to communicate with the modem through an RS-232 serial port. Following example is using the HyperTerminal in Windows 98. 3.1.2. On Windows 98, start the HyperTerminal program. Assign a name for a new session. DS020-7 Oct ‘06 ©2006 REG No 277 4001, ENGLAND. Page 11 GSM100 USERS MANUAL 3.1.3. Choose the correct Com port and baud rate settings; Fargo Maestro 100 : 115200bps, 8bits, no parity bit, 1 stop bit) . 3.1.4. On the terminal screen, type “AT” to check the “OK” response from the modem DS020-7 Oct ‘06 ©2006 REG No 277 4001, ENGLAND. Page 12 GSM100 USERS MANUAL 3.2. Basic Operation : Followings are examples of some AT commands. Please refer to the AT Command guide for a full description. Note : Issue AT+CMEE=1 to have extended error code (+CME ERROR) Description Network Registration Checking AT commands Modem response AT+CREG? CREG=,1 CREG=,2 CREG=,0 Comments Modem registered to the network Registration lost, re-registration attempt Modem not registration on the network, no registration attempt The first parameter has to be at least 15 for normal communication An incoming call is waiting Answer the call Receiving signal strength Receiving an incoming call AT+CSQ +CSQ: 20,0 RING ATA OK ATD1234567; OK Don’t forget the « ; » at the end for « voice » call Communication established PIN code not entered (with + CMEE = 1 mode) AOC credit exceeded or a communication is already established Cannot read the SIM card Don’t forget the « ; » at the end for « voice » call OK NO CARRIER Make a call CME ERROR : 11 CME ERROR : 3 CME ERROR : 10 Make an emergency call Communication loss ATD 112; ATH Hang up OK AT+CPIN=1234 OK Enter PIN code +CME ERROR : 16 +CME ERROR : 3 Saves parameters in non-volatile memory AT&W OK The configuration settings are stored Incorrect PIN Code (with +CMEE = 1 mode) PIN already entered (with +CMEE = 1 mode) PIN Code accepted DS020-7 Oct ‘06 ©2006 REG No 277 4001, ENGLAND. Page 13 GSM100 USERS MANUAL CHAPTER 4 SPECIFICATION Dualband GSM 900 / 1800 Mhz Support Data, SMS, Voice and Fax Max Power Output: 2W(900Mhz), 1W(1800Mhz) Group 3 FAX support (Class 1 and 2) Fargo Maestro 100 : GPRS Class B Class 10 (4Rx+1Tx or 3Rx+2Tx) at maximum speed.* SimToolKit Class 2 AT command set (GSM 07.05, GSM 07.07 and WAVECOM proprietary) * Note : Available slot for GPRS connection is network dependent. Power requirement : Input voltage range Rated current Typical current consumption GSM900 communication mode PCL=5 DCS1800 communication mode PCL=5 GPRS900 Class 10 PCL=5 GPRS1800 Class 10 PCL=0 Idle mode Idle mode with power saving on RS232 Interfaces : SIM holder 5V – 32V 650 mA (Fargo Maestro 100) @5V 310mA 240mA 520mA 390mA 35mA 12mA @12V 130mA 100mA 220mA 160mA 16mA 11mA @32V 50mA 40mA 80mA 70mA 8mA 5mA 15 pin Sub-D connector (serial and audio connection) 4-pin power supply connector SMA antenna connector (50 ohm) Dimensions: Overall size: Weight: Temperature range: 88mm x 60mm x 26mm 100g -15oC to +50oC operating -20oC to +65oC storage DS020-7 Oct ‘06 ©2006 REG No 277 4001, ENGLAND. Page 14 GSM100 USERS MANUAL CHAPTER 5 APPENDIX 5.1 Factory settings The modem has the following factory settings. Please refer to the AT command document for the meaning of each setting. Related AT commands AT+IPR AT+IFC AT+ICF ATE AT&C AT&D ATQ ATV AT&S ATS0 AT+CLIP AT+CRLP AT+CSCS AT+CMGF AT+CSMP AT+CNMI Factory Settings 9600 2,2 3,4 1 1 1 0 1 1 0 0 “PCCP437” 1 1,67,0,0 0,0,0,0 Description DTE-DCE data rate DTE-DCE flow control DTE-DCE character framing ECHO DCD signal DTR signal Result code suppression Response format DSR signal Auto answer Calling line ID presentation Calling line ID restriction Message format Text mode parameters New message indication 5.2 Input / Output port This port can be configured as either an input one or an output one. To configure it as an input port, first issue AT+WIOW=2, 0 to disable the output port. Use AT+WIOR=3(Fargo Maestro 100) or AT+WIOR=1(Fargo Maestro 20) to read the status of this input port. Response +WIOR: 0 represent Logic HIGH (>3V); Response +WIOR: 1 represent Logic LOW (
GSM100T 价格&库存

很抱歉,暂时无法提供与“GSM100T”相匹配的价格&库存,您可以联系我们找货

免费人工找货