Features
•
RF gateway via SPI interface
•
No configuration necessary
•
Simple SPI bus comms over RF
•
Miniature 3mm2 package
•
Range up to 2km
•
RF data rates to 500Kbps
•
No external components
•
Low voltage 2.2- 3.6V
•
Low BOM cost
•
Fast and effective RF development
Applications
•
Remote networking
•
USB/RS232 cable replacement
•
Remote data log
•
Meter reading
Description
The ZETA Codec chipset is an ultra simple way to communicate wirelessly without the
hassle research required to configure hundreds of registers and layout an RF matching
network.
Combine the ZETA Codec with RF Solutions’ low cost ZETA module using your chosen
frequency and start sending and receiving data without any the RF knowledge using an
SPI or UART interface for simple and robust communication.
Ordering Information
Part No
Description
ZETA-COD-QFN
Codec IC for ZETA module SMT QFN package
ZETA-COD-QSOP
Codec IC for ZETA module QSOP package
DS-ZETA-CODEC-1
ZETA Codec
U_CLK
2
GND
3
20
U_LVTTL RS232 RX
1
U_TVTTL_RS232 TX
U_MISO
U_SEL
U_MOSI
Connections - QFN package
19
18
17
16
U_IRQ
15
SDN
14
M_IRQ
GND
M_CTRL
NC
5
12
GND
FREQ SEL 1
6
11
M_CLK
FREQ SEL 2
7
8
9
10
M_MOSI
13
M_MISO
4
M_SEL
VDD
Mechanical dimensions
Pin 1 identifier
D
D2
A
Pin1 ID
D2/2
E2
GND
f
E
f/2
E2/2
A1
16X L
16X L1
4xcxc
16X b
e
L1 > 0
e/2
L1 = 0
Dimension
Min.
Typ.
Max.
A
0.50
0.55
0.60
A1
0.00
0.02
0.05
b
0.20
0.25
0.30
c
0.27
0.32
0.37
D
D2
3.00 BSC
1.60
e
0.50 BSC
E
3.00 BSC
E2
1.60
f
Page 2
1.70
1..70
1.80
1.80
2.53 BSC
L
0.30
0.40
0.50
L1
0.00
-
0.10
DS-ZETA-CODEC-1
ZETA Codec
Connections - QSOP package
U_SEL
U_MOSI
1
24
U_MISO
2
23
U_LVTTL_RS232 TX
U_CLK
3
22
U_LVTTL_RS232 RX
NC
4
21
U_IRQ
GND
5
20
SDN
VDD
6
19
M_IRQ
24pin QSOP
NC
7
18
M_CTRL
NC
8
17
M_CLK
NC
9
16
M_MOSI
NC
10
15
M_ISO
FREQ SEL 1
11
14
M_SEL
FREQ SEL 2
12
13
NC
Mechanical dimensions
A
E
E1
e
b
C
A
D
A1
L
Dimension
Min.
Typ.
Max.
A
-
-
1.75
A1
0.10
-
0.25
b
0.20
0.25
0.30
c
0.10
-
0.25
D
8.25 BSC
E
6.00 BSC
E1
3.90 BSC
e
0.635 BSC
L
Page 3
0.40
DS-ZETA-CODEC-1
-
1.27
ZETA Codec
Pin Description
Pin No
Name
Direction
Description
QFN
QSO
P
1
2
U_MISO
Output
SPI bus - Master Input Slave Output.
Output to controlling master IC
2
3
U_CLK
Input
SPI bus - Clock signal from master
controlling micro
3,12
5
GND
-
Ground connection(s)
4
6
VDD
Input
Power input 2.2 - 3.6V
5
4, 710,
13
NC
6,7
11,1
2
FREQ SEL
1/2
Input
Frequency Select to allow operation with
ZETA 433, 868 and 915MHz variants.
8
14
M_SEL
-
Connect to ZETA module: pin 12
(Codec to ZETA module SPI bus)
9
15
M_MISO
-
Connect to ZETA module: pin 11
(Codec to ZETA module SPI bus)
10
16
M_MOSI
-
Connect to ZETA module: pin 10
(Codec to ZETA module SPI bus)
11
17
M_CLK
-
Connect to ZETA module: pin 9
(Codec to ZETA module SPI bus)
13
18
M_CTRL
-
Connect to ZETA module: pin 7
(Codec to ZETA module SPI bus)
14
19
M_IRQ
-
Connect to ZETA module: pin 5
(Codec to ZETA module SPI bus)
Do not connect
Shutdown pin for sleep on both ZETA
module and ZETA CODEC (High=Shutdown)
When waking device wait for U_IRQ to go
high indicating device is ready for coms.
SPI bus - data ready interrupt
Active Low
Low Voltage TTL level (3.3V) UART data /
Are capable of 5V TTL
Low Voltage TTL level (3.3V) UART data /
Are capable of 5V TTL
15
20
SDN
-
16
21
U_IRQ
Output
17
22
U_LVTTL RX
Input
18
23
U_LVTTL TX
Output
19
24
U_SEL
Input
SPI bus chip select
Active Low
20
1
U_MOSI
Input
SPI bus, Master Output, Slave Input
Page 4
DS-ZETA-CODEC-1
ZETA Codec
Connections operational description
The ZETA Codec operates using a Serial Peripheral Interface (SPI) for synchronous, simple
industry standard communication between two remote points. ZETA Codec makes designing
RF into a circuit simpler and faster than ever before.
Simply pass data to the ZETA Codec using the SPI interface and it seamlessly transmits it to
a remote counterpart where the data is made ready and extraction notification is given via an
interrupt. No external peripheral components are required, simply connect the ZETA Codec to
a ZETA RF module as shown the application circuit, add an antenna and start communicating
wirelessly at ranges over 2km.
Additionally the ZETA Codec also contains a standard low level UART interface, via its LVTTL TX
and RX pins, these allow point to point RS232 communication. This may be used instead of the
SPI comms, but not as well as.
SPI interface pins
U_MISO
U_CLK
U_IRQ
U_SEL
U_MOSI
SPI interface to ZETA module
M_SEL
M_SEL
M_ISO
M_MOSI
M_CTRL
M_IRQ
M_SDN
The ZETA Codec communicates with the ZETA module via SPI, passing data to the ZETA
module in a ready to send via RF format. Only connection to the relevant pin on the ZETA
module is required for these lines. The interface between the two is completely handled by the
ZETA Codec and the ZETA module.
Shutdown / Sleep Mode for module and codec
U_SDN
M_SDN
The U_SDN pin is used to send the ZETA Module and the ZETA Codec into low power sleep
mode. The shutdown state is the lowest current consumption state of the device and is
entered by driving SDN high. In this state, all register contents are lost and there is no SPI
access. Drive low to exit.
The M_SDN pin passes the state of the U_SDN pin to the module.
RS232 Connection and serial data
U_LVTTL RX U_LVTTL RX
The RS232 connections operate in the same way as the SPI comms and use the same
command set . The RS232 pins can be used as an alternative form of communication but not
as well as the SPI comms.
FREQUENCY Select pins
FREQ SEL 1 FREQ SEL 2
The two frequency selection pins are set such that they tell the CODEC chip which ZETA
module it is to work with. Once configured the CODEC will change it’s Transmit and Receive
mode’s altering the available channels to the start points given on pages 6 and 7. The below
table defines the settings for each frequency:
Page 5
FREQ SEL1
FREQ SEL2
868MHz
NC
NC
915MHz
GND
NC
433MHz
NC
GND
DS-ZETA-CODEC-1
ZETA Codec
SPI command set and interface
Please Note: some terminal programs may require commands in different formats to the
examples shown in this document.
SPI bus flow diagram: receiving a data packet:
ZETA module
receives valid FM
data
Codec
validates via sync
bytes
Valid
Data fills FIFO
IRQ line taken
low
Your micro
clocks in data
Codec passes on
data
Invalid
Data rejected
Packet structure:
#R
Packet
length
RSSI*
Your data
* RSSI (Received Signal Strength Indicator) value is a single 8 bit byte with value 0 -255.
Mode selection:
Command for MODE select: ATM 1-3
Command
Name
Description
1
RX
The command enters RX mode using whichever settings
were last configured using the #R command below.
2
Ready
Ready is a low power wake state which can be used for
fast entry to RX or switching between TX and RX. Time
to RX or TX from READY 2.2
Vcc < 2.2
Max Input power (thro Antenna)
Max
Units
5.0
V
Vcc +
V
+10
dBm
Parameter
Min
Typical
Max
Units
Supply voltage
2.4
3
3.6
V
Operating temperature
-10
+55
C
o
ZETA Codec TX supply current:
When transmitting (At max power)
26
mA
ZETA Codec RX supply current:
Receiving
Ready
Standby (SDN High)
Page
DS-ZETA-CODEC-1
14.6
15
15.3
mA
5.0
5.2
5.5
mA
9
10
11
µA
ZETA Codec
Example schematic for connection to ZETA Module (QFN Version)
LL RS232 to host
SPI to host
Page
DS-ZETA-CODEC-1
ZETA Codec
Example schematic for connection to ZETA Module (SSOP Version)
LL RS232 to host
SPI to host
Page
DS-ZETA-CODEC-1
ZETA Codec
ZETA module and CODEC re-flow guide
ZETA MODULE is a 2 layer PCB, re-flow is based on IPC/JEDEC JSTD020C July 2004
Profile feature
Value (lead free)
Ramp up rate
3oC /s
Pre-heat temperature
- Temperature Min (TSmin)
- Temperature Max (Tsmax)
- Pre-heat time
1500C
2000C
60-100s
Peak temperature (TP)
2400C
Time at TP
10-20sec
Ramp down rate
60C/s
Time from 250C to peak
8 mins max.
Page
DS-ZETA-CODEC-1
ZETA Codec
Range Testing
RF Solutions range tested the ZETA module using the CODEC chipset 2 range
tests were carried out in different locations to prove the range consistently
Range test 1
Location: Ditchling Beacon, Sussex UK
Conditions: Light wind, overcast, dry.
Result: 2.2km (this is more than, would be expect in an urban environment).
Range test 2
Location: Hove, Sussex, UK
Conditions: Light wind, overcast, dry.
Page
DS-ZETA-CODEC-1
ZETA Codec
Simplified Declaration of Conformity (RED)
BG - С настоящото RF Solutions Limited декларира, че този тип радиосъоръжение Carlton-8T16 е в съответствие с Директива 2014/53/ЕС. Цялостният текст на ЕС
декларацията за съответствие може да се намери на следния интернет адрес: www.rfsolutions.co.uk
CS -Tímto RF Solutions Limited prohlašuje, že typ rádiového zařízení Carlton-8T16 je v souladu se směrnicí 2014/53/EU. Úplné znění EU prohlášení o
shodě je k dispozici na této internetové adrese: www.rfsolutions.co.uk
DA - Hermed erklærer RF Solutions Limited , at radioudstyrstypen Carlton-8T16 er i overensstemmelse med direktiv 2014/53/EU. EUoverensstemmelseserklæringens fulde tekst kan findes på følgende internetadresse: www.rfsolutions.co.uk
DE - Hiermit erklärt RF Solutions Limited , dass der Funkanlagentyp Carlton-8T16 der Richtlinie 2014/53/EU entspricht. Der vollständige Text der EUKonformitätserklärung ist unter der folgenden Internetadresse verfügbar: www.rfsolutions.co.uk
EL - Με την παρούσα ο/η RF Solutions Limited , δηλώνει ότι ο ραδιοεξοπλισμός Carlton-8T16 πληροί την οδηγία 2014/53/ΕΕ. Το πλήρες κείμενο της δήλωσης
συμμόρφωσης ΕΕ διατίθεται στην ακόλουθη ιστοσελίδα στο διαδίκτυο: www.rfsolutions.co.uk
EN - Hereby, RF Solutions Limited declares that the radio equipment type Carlton-8T16 is in compliance with Directive 2014/53/EU. The full text of the
EU declaration of conformity is available at the following internet address: www.rfsolutions.co.uk
ES - Por la presente, RF Solutions Limited declara que el tipo de equipo radioeléctrico Carlton-8T16 es conforme con la Directiva 2014/53/UE. El texto
completo de la declaración UE de conformidad está disponible en la dirección Internet siguiente: www.rfsolutions.co.uk
ET -Käesolevaga deklareerib RF Solutions Limited , et käesolev raadioseadme tüüp Carlton-8T16 vastab direktiivi 2014/53/EL nõuetele. ELi vastavusdeklaratsiooni täielik tekst on kättesaadav järgmisel internetiaadressil: www.rfsolutions.co.uk
FI -RF Solutions Limited vakuuttaa, että radiolaitetyyppi Carlton-8T16 on direktiivin 2014/53/EU mukainen. EU-vaatimustenmukaisuusvakuutuksen täysimittainen teksti on saatavilla seuraavassa internetosoitteessa: www.rfsolutions.co.uk
FR - Le soussigné, RF Solutions Limited , déclare que l'équipement radioélectrique du type Carlton-8T16 est conforme à la directive 2014/53/UE. Le
texte complet de la déclaration UE de conformité est disponible à l'adresse internet suivante: www.rfsolutions.co.uk
HR - RF Solutions Limited ovime izjavljuje da je radijska oprema tipa Carlton-8T16 u skladu s Direktivom 2014/53/EU. Cjeloviti tekst EU izjave o sukladnosti dostupan je na sljedećoj internetskoj adresi: www.rfsolutions.co.uk
HU - RF Solutions Limited igazolja, hogy a Carlton-8T16 típusú rádióberendezés megfelel a 2014/53/EU irányelvnek. Az EU-megfelelőségi nyilatkozat
teljes szövege elérhető a következő internetes címen: www.rfsolutions.co.uk
IT - Il fabbricante, RF Solutions Limited , dichiara che il tipo di apparecchiatura radio Carlton-8T16 è conforme alla direttiva 2014/53/UE. Il testo completo della dichiarazione di conformità UE è disponibile al seguente indirizzo Internet: www.rfsolutions.co.uk
LT - Aš, RF Solutions Limited , patvirtinu, kad radijo įrenginių tipas Carlton-8T16 atitinka Direktyvą 2014/53/ES. Visas ES atitikties deklaracijos tekstas
prieinamas šiuo interneto adresu: www.rfsolutions.co.uk
LV - Ar šo RF Solutions Limited deklarē, ka radioiekārta Carlton-8T16 atbilst Direktīvai 2014/53/ES. Pilns ES atbilstības deklarācijas teksts ir pieejams
šādā interneta vietnē: www.rfsolutions.co.uk
MT - B'dan, RF Solutions Limited , niddikjara li dan it-tip ta' tagħmir tar-radju Carlton-8T16 huwa konformi mad-Direttiva 2014/53/UE. It-test kollu taddikjarazzjoni ta' konformità tal-UE huwa disponibbli f'dan l-indirizz tal-Internet li ġej: www.rfsolutions.co.uk
NL - Hierbij verklaar ik, RF Solutions Limited , dat het type radioapparatuur Carlton-8T16 conform is met Richtlijn 2014/53/EU. De volledige tekst van de
EU-conformiteitsverklaring kan worden geraadpleegd op het volgende internetadres: www.rfsolutions.co.uk
PL - RF Solutions Limited niniejszym oświadcza, że typ urządzenia radiowego Carlton-8T16 jest zgodny z dyrektywą 2014/53/UE. Pełny tekst deklaracji
zgodności UE jest dostępny pod następującym adresem internetowym: www.rfsolutions.co.uk
PT - O(a) abaixo assinado(a) RF Solutions Limited declara que o presente tipo de equipamento de rádio Carlton-8T16 está em conformidade com a Diretiva 2014/53/UE. O texto integral da declaração de conformidade está disponível no seguinte endereço de Internet: www.rfsolutions.co.uk
RO - Prin prezenta, RF Solutions Limited declară că tipul de echipamente radio Carlton-8T16 este în conformitate cu Directiva 2014/53/UE. Textul integral al declarației UE de conformitate este disponibil la următoarea adresă internet: www.rfsolutions.co.uk
SK - RF Solutions Limited týmto vyhlasuje, že rádiové zariadenie typu Carlton-8T16 je v súlade so smernicou 2014/53/EÚ. Úplné EÚ
vyhlásenie o zhode je k dispozícii na tejto internetovej adrese: www.rfsolutions.co.uk
SL - RF Solutions Limited potrjuje, da je tip radijske opreme Carlton-8T16 skladen z Direktivo 2014/53/EU. Celotno besedilo izjave EU
o skladnosti je na voljo na naslednjem spletnem naslovu: www.rfsolutions.co.uk
SV - Härmed försäkrar RF Solutions Limited att denna typ av radioutrustning Carlton-8T16 överensstämmer med direktiv 2014/53/
EU. Den fullständiga texten till EU-försäkran om överensstämmelse finns på följande webbadress: www.rfsolutions.co.uk
RF Solutions Ltd. Recycling Notice
Meets the following EC Directives:
DO NOT
Discard with normal waste, please recycle.
ROHS Directive 2011/65/EU and amendment 2015/863/EU
Specifies certain limits for hazardous substances.
Waste Batteries and Accumulators
Directive 2006/66/EC
Where batteries are fitted, before recycling the
product, the batteries must be removed and
disposed of at a licensed collection point.
RF Solutions battery producer number:
BPRN00060.
WEEE Directive 2012/19/EU
Waste electrical & electronic equipment. This product must be disposed of through a licensed WEEE collection point. RF Soluti ons Ltd., fulfills its WEEE
obligations by membership of an approved compliance scheme. Environment Agency producer registration number: WEE/JB0104WV.
Disclaimer:
Whilst the information in this document is believed to be correct at the time of issue, RF Solutions Ltd does not accept any liability whatsoever for its accuracy, adequacy or
completeness. No express or implied warranty or representation is given relating to the information contained in this document. RF Solutions Ltd reserves the right to make
changes and improvements to the product(s) described herein without notice. Buyers and other users should determine for themselves the suitability of any such information or
products for their own particular requirements or specification(s). RF Solutions Ltd shall not be liable for any loss or damage caused as a result of user’s own determination of
how to deploy or use RF Solutions Ltd’s products. Use of RF Solutions Ltd products or components in life support and/or safety applications is not authorised except with
express written approval. No licences are created, implicitly or otherwise, under any of RF Solutions Ltd’s intellectual property rights. Liability for loss or damage resulting or
caused by reliance on the information contained herein or from the use of the product (including liability resulting from negligence or where RF Solutions Ltd was aware of
the possibility of such loss or damage arising) is excluded. This will not operate to limit or restrict RF Solutions Ltd’s liability for death or personal injury resulting from
its negligence.