PARAMETER
UNITS
TURNS S1,S2 = 10 turns, AWG 22 (Bifilar) S3 = 4 turns, AWG 28 S4 = 3 turns, AWG 28 S5 = 35 turns, AWG 28 S6 = 35 turns AWG 28 Isolation (min) S1 to S2 Isolation (min) S1 & S2 to S3 600 VRMS
100 WATT
FORWARD CONVERTER TRANSFORMER
Schematic Diagram PRI 1
600 VRMS VRMS VRMS VRMS
SEC 12 S6
Isolation (min) S4 to S5 & S6 600 Isolation (min) S5 to S6 1500 Isolation (min) S1 & S2 &S3 to S4 & S5 & S6 1500 Manufactured with UL rated materials. Wire rated at 155o minimum
2 3 4 5
S1
11 10
S2
S5 9 8 S4 7
S3 6
Physical Dimensions inches (mm)
Rhombus P/N: Cust. P/N: Date: 1/14/96
T-1038 Name: Sheet: 1 of 1
Rhombus Industries Inc.
Transformers & Magnetic Products
15801 Chemical Lane, Huntington Beach, CA 92649-1595 Phone: (714) 898-0960 z FAX: (714) 896-0971 www.rhombus-ind.com